Search NASA⌕ Search

SEARCH · Search NASA

Results for “PORTABLE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spacecraft signal sources portable test system

There is a frequent need to measure the frequency stability and phase noise levels of very high performance signal sources that are required for certain spacecraft missions. These measurements need to be done at different locations as the spacecraft subsystems progress through the various stages of development, assembly, test, and integration. Allan Deviation and Phase Noise of high performance sources are generally measured by comparing the unit under test to a reference standard. Five basic requirements are associated with making these kind of measurements: (1) the reference standard performance needs to be equal or better than the unit under test; (2) the measurement system needs to accommodate odd, nonstandard measurement frequencies that can range from 4 MHz to 35 GHz; (3) warm-up frequency drift and aging can corrupt a measurement and must be dealt with; (4) test equipment generated noise must be understood and prevented from limiting the measurements; (5) test equipment noise performance must be verifiable in the field as needed. A portable measurement system that was built by JPL and used in the field is described. The methods of addressing the above requirements are outlined and some measurement noise floor values are given. This test set was recently used to measure state of the art crystal oscillator frequency standards on the TOPEX and MARS OBSERVER spacecraft during several stages of acceptance tests.

Kirk, Albert↗

Radiometric calibrations of portable sources in the vacuum ultraviolet

The primary UV radiometric calibration standards of the Atomic and Plasma Radiation Division of the NBS are the hydrogen arc and the blackbody line arc. The secondary standards are the argon mini- and maxiarcs, and the deuterium arc lamp. Calibration methods involving both spectral radiance and irradiance, as well as the evaluation of their uncertainties, are discussed. Attention is given to the establishment of an irradiance scale, and the absolute spectral irradiance, measured as a function of wavelength, at a 50-cm distance from the field aperture for five different continuum sources.

Klose, Jules Z.↗

Portable light source unit for simulating fires having an adjustable aperture

A portable, hand held light source unit is employed to check operation of fire detectors, such as hydrogen fire detectors. The unit emits radiation in a narrow band of wavelengths which are generated by the type of fire to be tested, but not by other light sources such as the sun or incandescent lamps. The unit can test fire detectors at different distances, and of different sensitivities. The intensity of the radiation emitted by the unit is adjustable for this purpose by means of a rotatable disk having a plurality of different sized apertures for selective placement between the light source and an output lens. The disk can also be rotated to a calibration position which causes a microprocessor circuit in the unit to initiate a calibration procedure. During this procedure, the lamp intensity is measured by a photodetector contained within the unit, and the microprocessor adjusts the lamp current to insure that its intensity remains within a preset range of values. A green and a red LED are mounted on the unit which indicate to an operator whether the calibration is successful, as well as the condition of the unit's battery power supply.

Youngquist, Robert C.↗

The SeaWiFS Quality Monitor: A Portable Field Calibration Light Source

A portable and stable source, the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Quality Monitor, has been developed for use as a field instrument. The source can be used with either radiance- or irradiance-measuring sensors to transfer the laboratory calibration to the field so that the stability of the sensors can be monitored during the experiment. Temperature-controlled silicon photodiodes with colored glass filters are used to monitor the stability of the SeaWiFS Quality Monitor.

Shaw, Ping-Shine↗

Improved chlorate candle provides concentrated oxygen source

Improved chlorate candle is used as a solid, portable source of oxygen in emergency situations. It contains sodium chlorate, iron, barium peroxide, and glass mixed in powdered form. The oxygen evolves from the decomposition of the sodium chlorate when an ignition pellet is electrically initiated.

Haug, R. D.↗

ECLSS evolution: Advanced instrumentation interface requirements. Volume 3: Appendix C

An Advanced ECLSS (Environmental Control and Life Support System) Technology Interfaces Database was developed primarily to provide ECLSS analysts with a centralized and portable source of ECLSS technologies interface requirements data. The database contains 20 technologies which were previously identified in the MDSSC ECLSS Technologies database. The primary interfaces of interest in this database are fluid, electrical, data/control interfaces, and resupply requirements. Each record contains fields describing the function and operation of the technology. Fields include: an interface diagram, description applicable design points and operating ranges, and an explaination of data, as required. A complete set of data was entered for six of the twenty components including Solid Amine Water Desorbed (SAWD), Thermoelectric Integrated Membrane Evaporation System (TIMES), Electrochemical Carbon Dioxide Concentrator (EDC), Solid Polymer Electrolysis (SPE), Static Feed Electrolysis (SFE), and BOSCH. Additional data was collected for Reverse Osmosis Water Reclaimation-Potable (ROWRP), Reverse Osmosis Water Reclaimation-Hygiene (ROWRH), Static Feed Solid Polymer Electrolyte (SFSPE), Trace Contaminant Control System (TCCS), and Multifiltration Water Reclamation - Hygiene (MFWRH). A summary of the database contents is presented in this report.

Source record↗

SeaWiFS technical report series. Volume 11: Analysis of selected orbit propagation models for the SeaWiFS mission

An analysis of orbit propagation models was performed by the Mission Operations element of the Sea-viewing Wide Field-of-View Sensor (SeaWiFS) Project, which has overall responsibility for the instrument scheduling. The orbit propagators selected for this analysis are widely available general perturbations models. The analysis includes both absolute accuracy determination and comparisons of different versions of the models. The results show that all of the models tested meet accuracy requirements for scheduling and data acquisition purposes. For internal Project use the SGP4 propagator, developed by the North American Air Defense (NORAD) Command, has been selected. This model includes atmospheric drag effects and, therefore, provides better accuracy. For High Resolution Picture Transmission (HRPT) ground stations, which have less stringent accuracy requirements, the publicly available Brouwer-Lyddane models are recommended. The SeaWiFS Project will make available portable source code for a version of this model developed by the Data Capture Facility (DCF).

Patt, Frederick S.↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation

The document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. This document supersedes the earlier version (Mueller and Austin 1995) published as Volume 25 in the SeaWiFS Technical Report Series. This document marks a significant departure from, and improvement on, theformat and content of Mueller and Austin (1995). The authorship of the protocols has been greatly broadened to include experts specializing in some key areas. New chapters have been added to provide detailed and comprehensive protocols for stability monitoring of radiometers using portable sources, abovewater measurements of remote-sensing reflectance, spectral absorption measurements for discrete water samples, HPLC pigment analysis and fluorometric pigment analysis. Protocols were included in Mueller and Austin (1995) for each of these areas, but the new treatment makes significant advances in each topic area. There are also new chapters prescribing protocols for calibration of sun photometers and sky radiance sensors, sun photometer and sky radiance measurements and analysis, and data archival. These topic areas were barely mentioned in Mueller and Austin (1995).

Fargion, Giulietta S.↗

Portable Welder

A low cost, low power, self-contained portable welding gun designed for joining thermoplastics which become soft when heated and harden when cooled was developed originally by NASA's Langley Research Center for repairing helicopter windshields. Welder has a broad range of applications for joining both thermoplastic materials in the aerospace, automotive, appliance, and construction industries. Welders portability and low power requirement allow its use on-site in any type of climate, with power supplied by a variety of portable sources.

Source record↗

Radiant heat source, vacuum bag, provide portable bonding oven

Portable bonding oven is formed to any desired size or configuration to attach doublers and brackets to the surfaces of large structures. A radiant heat source is used in combination with a heat resistant transport vacuum bag and a black heat absorbing cloth.

Nicholls, A. H.↗

Development of a portable, high-energy radiographic source

A two-year program has been undertaken to develop a portable high-energy (3-4 MeV) radiographic system for in-service and repair inspections of components at nuclear power stations. The basic design concept uses a lightweight portable linear accelerator. This paper describes the design objectives, concepts employed, and progress to date. Specific potential applications and accompanying radiographic techniques are discussed, along with novel beam-angulation devices that permit utilization in areas of highly restricted access.

Reinhart, E. R.↗

Small Portable PEM Fuel Cell Systems for NASA Exploration Missions

Oxygen-Hydrogen PEM-based fuel cell systems are being examined as a portable power source alternative in addition to advanced battery technology. Fuel cell power systems have been used by the Gemini, Apollo, and Space Shuttle programs. These systems have not been portable, but have been integral parts of their spacecraft, and have used reactants from a separate cryogenic supply. These systems typically have been higher in power. They also have had significant ancillary equipment sections that perform the pumping of reactants and coolant through the fuel cell stack and the separation of the product water from the unused reactant streams. The design of small portable fuel cell systems will be a significant departure from these previous designs. These smaller designs will have very limited ancillary equipment, relying on passive techniques for reactant and thermal management, and the reactant storage will be an integral part of the fuel cell system. An analysis of the mass and volume for small portable fuel cell systems was done to evaluate and quantify areas of technological improvement. A review of current fuel cell technology as well as reactant storage and management technology was completed to validate the analysis and to identify technology challenges

Burke, Kenneth A.↗

Lithium Iron Phosphate Cell Performance Evaluations for Lunar Extravehicular Activities

Lithium-ion battery cells are being evaluated for their ability to provide primary power and energy storage for NASA s future Exploration missions. These missions include the Orion Crew Exploration Vehicle, the Ares Crew Launch Vehicle Upper Stage, Extravehicular Activities (EVA, the advanced space suit), the Lunar Surface Ascent Module (LSAM), and the Lunar Precursor and Robotic Program (LPRP), among others. Each of these missions will have different battery requirements. Some missions may require high specific energy and high energy density, while others may require high specific power, wide operating temperature ranges, or a combination of several of these attributes. EVA is one type of mission that presents particular challenges for today s existing power sources. The Portable Life Support System (PLSS) for the advanced Lunar surface suit will be carried on an astronaut s back during eight hour long sorties, requiring a lightweight power source. Lunar sorties are also expected to occur during varying environmental conditions, requiring a power source that can operate over a wide range of temperatures. Concepts for Lunar EVAs include a primary power source for the PLSS that can recharge rapidly. A power source that can charge quickly could enable a lighter weight system that can be recharged while an astronaut is taking a short break. Preliminary results of Al23 Ml 26650 lithium iron phosphate cell performance evaluations for an advanced Lunar surface space suit application are discussed in this paper. These cells exhibit excellent recharge rate capability, however, their specific energy and energy density is lower than typical lithium-ion cell chemistries. The cells were evaluated for their ability to provide primary power in a lightweight battery system while operating at multiple temperatures.

Reid, Concha↗

Vacuum-Ultraviolet Intensity-Calibration Standard

Portable light source enables calibration of spectrometers. Vacuum Ultraviolet Light (40 to 200 nm) produced in electron-impact emission chamber by leading beam of gas across electron beam. Photons observed at right angles to electron-beam axis. Previously, there were blackbody standards in visible and near ultraviolet, but no intensity-calibration standards in VUV.

Ajello, J. M.↗