HEAVY ION FUSION SCIENCE VIRTUALNATIONAL LABORATORY 2nd QUARTER 2009 MILESTONE REPORT: Perform beam and target experiments with a new induction bunching module, extended FEPS plasma, and improved target diagnostic and positioning equipment on NDCX

This effort contains two main components: The new induction-bunching module is expected to deliver higher fluence in the bunched beam, and the new target positioner will enable a significantly enhanced target physics repetition rate. The velocity ramp that bunches the K{sup +} beam in the neutralized drift compression section is established with a bipolar voltage ramp applied to an acceleration gap. An induction acceleration module creates this voltage waveform. The new bunching module (IBM) specially built for NDCX has approximately twice the capability (volt-seconds) as our original IBM. We reported on the beam line design for the best use of the bunching module in our FY08 Q2 report. Based on simulations and theoretical work, we chose to extend the drift compression section and use the additional volt-seconds to extend the pulse duration and keep the peak voltage swing (and velocity excursions) similar to the present module. Simulations showed that this approach, which extends the drift section, to be advantageous because it limits the chromatic aberrations in the beam spot on target. To this end, colleagues at PPPL have fabricated the meter-long extension to the ferroelectric plasma source and it was installed on the beam line with the new IBM in January 2009. Simulation results suggest a factor of two increase in energy deposition from the bunched beam. In the first WDM target run (August-November 2008) the target handling setup required opening the vacuum system to manually replace the target after each shot (which destroys the target). Because of the requirement for careful alignment of each individual target, the target shot repetition rate was no greater than 1 shot per day. Initial results of this run are reported in our FY08 4th Quarter Milestone Report. Based on the valuable experience gained in the initial run, we have designed and installed an improved target alignment and positioning system with the capability to reposition targets remotely. This capability allows us to significantly increase our shot repetition rate, and to take greater advantage of the pinhole/cone arrangement we have developed to localize the beam at final focus. In addition we have improved the capability of the optical diagnostic systems, and we have installed a new beam current transformer downstream of the target to monitor beam current transmitted through the target during an experiment. These improvements will allow us to better exploit the inherent capability of the NDCX facility for high repetition rate and thus to provide more detailed experimental data to assess WDM physics models of target behavior. This milestone has been met by demonstrating highly compressed beams with the new bunching module, which are neutralized in the longer drift compression section by the new ferro-electric plasma sources. The peak uncompressed beam intensity ({approx}600 kW/cm{sup 2}) is higher than in previous measurements, and the bunched beam current profiles are {approx}2ns. We have also demonstrated a large increase in the experimental data acquisition rate for target heating experiments. In the first test of the new remote-controlled target positioning system, we completed three successful target physics shots in less than two hours. Further improvements are expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Obese patients and radiography literature: what do we know about a big issue?

Obesity is a global health issue with obese patients requiring specialised diagnosis, treatment and care through the health service. The practical and social difficulties associated with medical imaging of obese patients are an increasingly common problem and it is currently unknown how student and qualified radiographers perceive and respond to these challenges. By better understanding challenges presented in providing quality imaging and care of imaging obese patients, education for both qualified and student radiographers can be enhanced. Radiographers are heavily reliant on visual and tactile senses to locate the position of anatomical structures for diagnostic imaging and determine radiation exposure through a delicate consideration of dose, image quality and anatomical attenuation. However, obese patients require modifications to routine radiographic practice in terms of movement/assisted positioning, equipment capabilities to take increased weight or coverage. These patients may also be subject to compromised radiological diagnosis through poor visualisation of structures. In this paper, the professional and educational literature was narratively reviewed to assess gaps in the evidence base related to the skill and care knowledge for obese patients. Literature was sourced relating to discrete radiographic considerations such as the technical factors of imaging obese patients, exposure and the impact of obesity on imaging departments’ service provisions. The recent literature (post-2000 to coincide with the sharp increase in global obesity) on the perceptions of health professionals and student health practitioners has also been explored because there are no specific radiographer studies to report. By understanding the research in similar fields, we may identify what common attitudes qualified and student radiographer's hold and what challenges, technical and care related, can be prepared for.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safeguard Application Options for the Laser-Based Item Monitoring System (LBIMS)

Researchers at Oak Ridge National Laboratory (ORNL) are developing a Laser-Based Item Monitoring System (LBIMS) for advanced safeguards at nuclear facilities. LBIMS uses a low-power laser transceiver to monitor the presence and position of items with retroreflective tags. The primary advantages of LBIMS are its scalability to continuously monitor a wide range of items, its ability to operate unattended, its low cost of implementation, and its inherent information security due to its line-of-sight and non-broadcasting operation. The primary proposed safeguard application of LBIMS is described in its name: item monitoring. LBIMS could be implemented in a storage area to continuously monitor containers of nuclear material and the area in which they are stored. The system could be configured to provide off-site notification if any of the containers are moved or removed or if the area is accessed. Individual tags would be used to monitor storage containers, and additional tags could be used to record information regarding secondary storage units and room access. The capability to register small changes in tag position opens up the possibility of several other uses. These include continuously monitoring piping arrangements for design information verification or recording equipment positions for other safeguards systems, such as tracking the opening and closing of autoclaves as part of a cylinder tracking system or opening and closing valves on a sample or product take-off line. Combined with attribute tags, which transmit information from any kind of sensor by modulating the laser signal, LBIMS provides the capability to wirelessly and securely collect safeguards data, even in areas where radio-frequency or other wireless communication methods are not practicable. Four application types are described in this report: static item monitoring, in-process item monitoring with trigger tags, multi-layered integration with trigger tags, and line-of-sight data transfer with attribute tags. Field trials for each of these applications are described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NSLS-II Booster Survey and Alignment Systems

This section outlines the survey and alignment requirements and the technology and tools for achieving the NSLS-II equipment positioning goals. The required alignment tolerances are defined primarily by the physics requirements of the accelerator. The tight tolerances dictated by the physics requirements are an order of magnitude tighter than the tolerances of second generation light sources (NSLS) and on level with those at third generation light sources (Soleil, Diamond). These extraordinary position requirements necessitate a concerted R&D engineering effort to identify and develop the survey methodology needed to meet these requirements. As of this date, the methodology is still evolving to balance cost and time constraints while still maintaining the integrity of the survey and alignment systems. State-of-the art equipment including Laser Trackers and Laser Arms have been purchased and used extensively in the pursuit of meeting the NSLS-II survey tolerances. No new technology will need to be developed to meet the alignment requirements but new techniques will be pursued and developed. Survey and alignment provides the foundation for positioning the beam-guiding magnet structures in all 6 degrees of freedom within the required tolerances. Although the tools and instrumentation available for this task have changed over the years and faster and more accurate measurements are possible, only limited control of the environmental conditions is possible. This ultimately sets an upper limit for the achievable measurement and subsequent control network accuracy. At the same time, the control of environmental variables (temperature, humidity) will be fully taken advantage of during the building of NSLS-II , opening up the possibility of ever-increasing accuracy unheard of only five years ago.

42 ENGINEERING↗

NSLS-II Booster Survey and Alignment Systems

This section outlines the survey and alignment requirements and the technology and tools for achieving the NSLS-II equipment positioning goals. The required alignment tolerances are defined primarily by the physics requirements of the accelerator. The tight tolerances dictated by the physics requirements are an order of magnitude tighter than the tolerances of second generation light sources (NSLS) and on level with those at third generation light sources (Soleil, Diamond). These extraordinary position requirements necessitate a concerted R&D engineering effort to identify and develop the survey methodology needed to meet these requirements. As of this date, the methodology is still evolving to balance cost and time constraints while still maintaining the integrity of the survey and alignment systems. State-of-the art equipment including Laser Trackers and Laser Arms have been purchased and used extensively in the pursuit of meeting the NSLS-II survey tolerances. No new technology will need to be developed to meet the alignment requirements but new techniques will be pursued and developed.

36 MATERIALS SCIENCE↗

Rapid Reflective Facet Characterization Using Fringe Reflection Techniques

Reflective mirror facets for concentrating solar power (CSP) systems have stringent requirements on the surface slope accuracy in order to provide adequate system performance. This paper presents a tool that can fully characterize facets quickly enough for 100% inspection on a production line. A facet for a CSP system, specifically a dish concentrator has a parabolic design shape. This shape will concentrate near-parallel rays from the sun to a point (or a line for trough systems). Deviations of surface slope from the design shape impact the performance of the system, either losing power that misses the target or increasing peak fluxes to undesirable levels. During development or production, accurate knowledge of facet defects can lead to improvements to lower cost or improve performance. The reported characterization system, SOFAST (Sandia Optical Fringe Analysis Slope Tool), has a computer-connected camera that images the reflective surface, which is positioned so that it reflects an active target, such as an LCD screen, to the camera. A series of fringe patterns are displayed on the screen while images are captured. Using the captured information, the reflected target location of each pixel of mirror viewed can be determined, and thus through a mathematical transformation, a surface normal map can be developed. This is then fitted to the selected model equation, and the errors from design are characterized. While similar approaches have been explored, several key developments are presented here. The combination of the display, capture, and data reduction in one system allows rapid characterization. An “electronic boresight” approach is utilized to accommodate physical equipment positioning deviations, making the system insensitive to setup errors. Up to 1.5×10 6 points are characterized on each facet. Finally, while prior automotive industry commercial systems resolve the data to shape determination, SOFAST concentrates on slope characterization and reporting, which is tailored to solar applications. SOFAST can be used for facet analysis during development. However, the real payoff is in production, where complete analysis is performed in about 10s. With optimized coding, this could be further reduced.

14 SOLAR ENERGY↗

Validating a Model for Welding Induced Residual Stress Using High-Energy X-ray Diffraction

Integrated computational materials engineering (ICME) provides a pathway to advance performance in structures through the use of physically-based models to better understand how manufacturing processes influence product performance. As one particular challenge, consider that residual stresses induced in fabrication are pervasive and directly impact the life of structures. For ICME to be an effective strategy, it is essential that predictive capability be developed in conjunction with critical experiments. In the present paper, simulation results from a multi-physics model for gas metal arc welding are evaluated through x-ray diffraction using synchrotron radiation. A test component was designed with intent to develop significant gradients in residual stress, be representative of real-world engineering application, yet remain tractable for finely spaced strain measurements with positioning equipment available at synchrotron facilities. Finally, the experimental validation lends confidence to model predictions, facilitating the explicit consideration of residual stress distribution in prediction of fatigue life.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RSA calibration accuracy of a fluoroscopy-based system using nonorthogonal images for measuring functional kinematics

When performing radiostereometric analysis (RSA) in a clinical setting it may be desirable to orient the two imaging devices nonorthogonally to obtain the best views of an anatomical structure. In this study, a calibration frame was constructed that allowed the relative angles of fiducial and control planes to be adjusted. Precision and accuracy were quantified across multiple trials and orientations. The 90 deg. frame was always of equivalent or greater accuracy than a calibration frame with the fiducial and control planes aligned parallel to the image intensifiers. This study also showed that RSA may be performed with imaging devices at relative angles other than 90 deg. without compromising accuracy. This allows researchers greater freedom in positioning equipment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A convenient alignment approach for x-ray imaging experiments based on laser positioning devices

This study presents a two-laser alignment approach for facilitating the precise alignment of various imaging and measuring components with respect to the x-ray beam. The first laser constantly pointed to the output window of the source, in a direction parallel to the path along which the components are placed. The second laser beam, originating from the opposite direction, was calibrated to coincide with the first laser beam. Thus, a visible indicator of the direction of the incident x-ray beam was established, and the various components could then be aligned conveniently and accurately with its help.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A real-time respiration position based passive breath gating equipment for gated radiotherapy: A preclinical evaluation

Purpose: To develop a passive gating system incorporating with the real-time position management (RPM) system for the gated radiotherapy. Methods: Passive breath gating (PBG) equipment, which consists of a breath-hold valve, a controller mechanism, a mouthpiece kit, and a supporting frame, was designed. A commercial real-time positioning management system was implemented to synchronize the target motion and radiation delivery on a linear accelerator with the patient's breathing cycle. The respiratory related target motion was investigated by using the RPM system for correlating the external markers with the internal target motion while using PBG for passively blocking patient's breathing. Six patients were enrolled in the preclinical feasibility and efficiency study of the PBG system. Results: PBG equipment was designed and fabricated. The PBG can be manually triggered or released to block or unblock patient's breathing. A clinical workflow was outlined to integrate the PBG with the RPM system. After implementing the RPM based PBG system, the breath-hold period can be prolonged to 15-25 s and the treatment delivery efficiency for each field can be improved by 200%-400%. The results from the six patients showed that the diaphragm motion caused by respiration was reduced to less than 3 mm and the position of the diaphragm was reproducible for difference gating periods. Conclusions: A RPM based PBG system was developed and implemented. With the new gating system, the patient's breath-hold time can be extended and a significant improvement in the treatment delivery efficiency can also be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Marine Corps Base Camp Lejeune Intracoastal Waterway Shoreline Characterization

Critical military training and testing on lands along the nation’s coastal and estuarine shorelines are increasingly placed at risk because of development pressures in surrounding areas, impairments due to other anthropogenic disturbances, and increasing requirements for compliance with environmental regulations. The U.S. Department of Defense (DoD) intends to enhance and sustain its training and testing assets and to optimize its stewardship of natural resources through the development and application of an ecosystem-based management approach on DoD installations. To accomplish this goal, particularly for installations in estuarine/coastal environments, the Strategic Environmental Research and Development Program (SERDP) launched the Defense Coastal/Estuarine Research Program (DCERP) as a minimum 10-year effort at Marine Corps Base Camp Lejeune (MCBCL) in North Carolina. The results of the first six years of the program (DCERP1) are presented here.The overarching objectives of DCERP are to: (1) understand the effects of military training activities, infrastructure development, and other coastal military installations; (2) develop models, tools, and indicators to evaluate ecosystem health; and (3) recommend adaptive management strategies to sustain ecosystem natural resources within the context of an active military installation.Shoreline characterization of the Intracoastal waterway within the foundries of Marine Corps Base Camp Lejeune. Data was collected by ground truth methods and included boat operations. The shoreline of the ICW was characterized by boat in April and June 2010 using Global Positioning Systems (GPS) equipment and ArcGIS software. The previously digitized 2009 shoreline was edited within ArcGIS, using GPS equipment to obtain the position of the boat relative to the shoreline. Four fields were created for the shoreline shapefile, including: shoreline type, vegetation/species, modification type and relief. A unique identifying code was created by concatenating the field values of the four fields. in January 2013 the field Veg_2 was created for the output of SLtype and Vegtype codeing.

54 ENVIRONMENTAL SCIENCES↗

Roller Cam Positioners

Roller Cam Positioners could support the LCLS undulator sections allowing micron sized alignment adjustment of each undulator in 5 degrees of freedom. The supports are kinematic with the number of degrees of freedom matched to the number of constraints. Ton loads are supported on simple ball bearings. Motion is intrinsically bounded. Positioning mechanisms are based on pure rolling motion with sub-micron hysteresis and micron resolution. This note describes a general purpose positioning mechanism suitable for undulator support.

43 PARTICLE ACCELERATORS↗

Pulse Processing System for the RADMAP Radiation Modulation Aperture Imager

We are currently developing a portable radiation imager for emergency responders. The instrument contains a position-sensitive photomultiplier tube with a thin CsI(Na) scintillator and a tungsten radiation modulation aperture. As part of this project, we have designed a novel pulse processing system to record the amplitude and position of incident events. This system consists of four charge-to-pulse-width converters that transfer time-modulated digital pulses to a field-programmable gate array. The design can process data at count rates exceeding 40,000 events per second and transmit data over an Ethernet link at 1 Gb/sec.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TESTING OF THE RADBALL TECHNOLOGY AT SAVANNAH RIVER NATIONAL LABORATORY

The United Kingdom's National Nuclear Laboratory (NNL) has developed a remote, nonelectrical, radiation-mapping device known as RadBall (patent pending), which offers a means to locate and quantify radiation hazards and sources within contaminated areas of the nuclear industry. Positive results from initial deployment trials in nuclear waste reprocessing plants at Sellafield in the United Kingdom and the anticipated future potential use of RadBall throughout the U.S. Department of Energy Complex have led to the NNL partnering with the Savannah River National Laboratory (SRNL) to further test, underpin, and strengthen the technical performance of the technology. The study completed at SRNL addresses key aspects of the testing of the RadBall technology. The first set of tests was performed at Savannah River Nuclear Solutions Health Physics Instrument Calibration Laboratory (HPICL) using various gamma-ray sources and an x-ray machine with known radiological characteristics. The objective of these preliminary tests was to identify the optimal dose and collimator thickness. The second set of tests involved a highly contaminated hot cell. The objective of this testing was to characterize a hot cell with unknown radiation sources. The RadBall calibration experiments and hot cell deployment were successful in that for each trial radiation tracks were visible. The deployment of RadBall can be accomplished in different ways depending on the size and characteristics of the contaminated area (e.g., a hot cell that already has a crane/manipulator available or highly contaminated room that requires the use of a remote control device with sensor and video equipment to position RadBall). This report also presents SRNL-designed RadBall accessories for future RadBall deployment (a harness, PODS, and robot).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electronics System for the GammaTracker Handheld CdZnTe Detector

We are currently developing a handheld radioisotope identifier containing eighteen position-sensitive CdZnTe crystals. In addition to isotope identification, the device performs basic Compton imaging to determine the location of suspected sources. This paper gives an overview of the electronics system we have designed for this instrument. We use specialized application-specific integrated circuits to preprocess the outputs of each CdZnTe crystal. A low-power microprocessor running Windows CE drives the user interface and implements the isotope identification and directionality computations. Finally, we use a field-programmable gate array to perform the computationally intensive imaging tasks in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote-Controlled Removal of Bricks from a Reactor Shaft: An Unconventional Approach - 16406

The first German prototype Fast Breeder Nuclear Reactor (KNK) is currently being dismantled after being the only operating Fast Breeder-type reactor in Germany. The complete dismantling is based on 10 decommissioning permits. Package 3 of the 9. decommissioning permit, which is currently under preparation, comprises the dismantling of the biological shield. Package 2 comprised the dismantling of the Primary Shield. In preparation to lift the 14 primary shield segments on height of the reactor core, these were milled at 16 positions and equipped with a total of 26 holes. As a result of the milling and drilling process, an estimated amount of 500-600 kg cast iron swarfs accumulated at the bottom of the 12 m deep reactor shaft. The cobalt in the cast iron was activated to cobalt-60 during operation. This results in a measurable dose-rate of 30-35 mSv/h. At the conical bottom of the reactor shaft were still the remaining parts of the thermal insulation consisting of a lining with brick stones, covered with loose remnants of the thermal insulation, loose metallic residues and cut-off wheels of the angel grinder. For the next dismantling step, the removal of the activated part of the biological shield, it is necessary that the cast iron swarfs must be removed as well as the remains of the thermal insulation. Firstly, this is necessary to reduce the dose rate inside the shaft for subsequent breakthrough operations and, secondly to have a statically resilient surface for the installation of a necessary working platform for next dismantling tools. There was no access for personnel. A manual removal was also not possible due to the existing dose rate. The cast iron swarfs supposed to be removed by a remote controlled suction unit, which was installed on top of a drum and mounted in a special rack. The complete system was lowered into the reactor shaft by using a crane. After removing the major amount of swarfs, the remaining swarfs as well as the sheet metal liner should be collected with a magnetic grabber. The solution for the metal removal was easy to realize, but there was no idea how to remove the remaining bricks remote controlled out of the reactor shaft. Another boundary was that only existing facilities were supposed to be used in addition to the new suction system, i.e. the existing cranes, gripper, as well as the double lid lock of the encasing for the handling of the vacuum cleaner, the transport of the drum and the lock procedure. The design essentially consists of a suction unit and a collecting unit. Both units are connected hooked by the three single suspension chains on the rack on the traverse and connection of the suction tube. Subsequently the entire unit was drained in the 12 m deep reactor shaft. The entire unit has been lifted out of the reactor shaft and placed on a defined set-down position. At this position, now both of the units could be separated by using the Master-Slave-Manipulator in the encasing (A100). By using different suction pipes the reactor shaft bottom could be exempted from the cast iron swarfs within a few days. The suction unit worked in such a positive way that it was decided to remove the loose refractory bricks, metallic residues, cut off wheels, etc., too. Metal parts remaining on the ground were removed by a magnet. This pragmatic approach avoided additional complex design works and the need of constructing special solutions and thus, massively saved time, cost and dose rate. The duration of planning, permission including implementation amounted to approximately 3 to 4 months. The additional work could be performed directly after the actual dismantling step.

07 ISOTOPE AND RADIATION SOURCES↗

Directionality in the GammaTracker Handheld Radioisotope Identifier

Several computationally simple methods are presented for determining the direction to one or more point sources using the GammaTracker handheld radioisotope identifier. GammaTracker will display a heading indicating the direction to one or more sources; no gamma-ray images will be displayed to the user. The details of each directionality method are presented and performance is compared using radiation transport simulations of gamma-ray point sources at varying activity levels on a natural background. All methods achieved sufficiently high pointing accuracy and precision in the tested scenarios, which included background-to-source ratios up to 10:1. The prospects for implementation in the GammaTracker firmware architecture are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting ptychography probe positions using single-shot phase retrieval neural network

Ptychography is a powerful imaging technique that is used in a variety of fields, including materials science, biology, and nanotechnology. However, the accuracy of the reconstructed ptychography image is highly dependent on the accuracy of the recorded probe positions which often contain errors. These errors are typically corrected jointly with phase retrieval through numerical optimization approaches. When the error accumulates along the scan path or when the error magnitude is large, these approaches may not converge with satisfactory result. We propose a fundamentally new approach for ptychography probe position prediction for data with large position errors, where a neural network is used to make single-shot phase retrieval on individual diffraction patterns, yielding the object image at each scan point. The pairwise offsets among these images are then found using a robust image registration method, and the results are combined to yield the complete scan path by constructing and solving a linear equation. We show that our method can achieve good position prediction accuracy for data with large and accumulating errors on the order of 10 2 pixels, a magnitude that often makes optimization-based algorithms fail to converge. For ptychography instruments without sophisticated position control equipment such as interferometers, our method is of significant practical potential.

47 OTHER INSTRUMENTATION↗