Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER CONDITIONING CIRCUITS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Power supply conditioning circuit

A power supply conditioning circuit that can reduce Periodic and Random Deviations (PARD) on the output voltages of dc power supplies to -150 dBV from dc to several KHz with no measurable periodic deviations is described. The PARD for a typical commercial low noise power supply is -74 dBV for frequencies above 20 Hz and is often much worse at frequencies below 20 Hz. The power supply conditioning circuit described here relies on the large differences in the dynamic impedances of a constant current diode and a zener diode to establish a dc voltage with low PARD. Power supplies with low PARD are especially important in circuitry involving ultrastable frequencies for the Deep Space Network.

Primas, L. E.↗

Power-Supply-Conditioning Circuit

Fluctuations of voltage suppressed in power supplies for precise radio-frequency circuits. Circuit suppresses both periodic and random deviations of dc supply voltage from desired steady level. Highly-stable feedback voltage regulator, conditioner intended in conjunction with conventional power-supply circuit to provide constant voltage to atomic frequency standard or other precise oscillator. Without conditioners, outputs of most commercial power supplies contain fluctuations causing unacceptably-large phase and amplitude modulation of precise oscillators.

Primas, L. E.↗

Power supply conditioning circuit

A conditioning circuit is provided with a constant current diode in series with a zener diode, the former having a high dynamic impedance and the latter a low dynamic impedance. The constant current diode can receive an input voltage with PARD. In conjunction with the zener diode fixed to a ground, a voltage divider is provided which can give an output voltage whose PARD was significantly reduced. The conditioning circuit is effective down to dc.

Primas, Lori E.↗

Solar power conditioner

Efficient power-conditioning circuit designed to utilize maximum power available from solar cell array, controls output of array so that excess energy not needed by load is diverted to charge batteries for reserve power when sufficient sunlight is not available.

Jan, L.↗

Preliminary design development of 100 KW rotary power transfer device

Contactless power transfer devices for transferring electrical power across a rotating spacecraft interface were studied. A power level of 100 KW was of primary interest and the study was limited to alternating current devices. Rotary transformers and rotary capacitors together with the required dc to ac power conditioning electronics were examined. Microwave devices were addressed. The rotary transformer with resonant circuit power conditioning was selected as the most feasible approach. The rotary capacitor would be larger while microwave devices would be less efficient. A design analysis was made of a 100 KW, 20 kHz power transfer device consisting of a rotary transformer, power conditioning electronics, drive mechanism and heat rejection system. The size, weight and efficiency of the device were determined. The characteristics of a baseline slip ring were presented. Aspects of testing the 100 KW power transfer device were examined. The power transfer device is a feasible concept which can be implemented using presently available technologies.

Weinberger, S. M.↗

Power processing system for a 200 watt communication satellite transmitter

A power processing system (PPS) for a communication satellite, high power (200W RF) multi-stage depressed collector, 12 GHz, traveling wave tube, is described. The PPS converts spacecraft bus power at a nominal voltage of 76 Vdc to the levels necessary for operating a ten-collector coupled cavity TWT requiring approximately 500 watts of input power. Regulated voltages of up to -11.3K Vdc are provided along with command, protection and telemetry signal conditioning circuits. Power processor interface requirements are set forth and a block diagram illustrating the basic approach utilized is presented. Overall performance, design characteristics and unique features are discussed. Thermal and mechanical interface requirements impacting on PPS design are described as well as the thermal control technique utilized for the overall PPS/TWT assembly.

Farber, B. F.↗

High Performance Low Cost Power Conditioning Subsystems Using Smart Power/ Power Integrated Circuits in Photovoltaic Power Systems

New technologies like Smart Power, and Power Integrated Circuits are the wave of the future in providing high performance low cost power conditioning subsystem (PCS)in small to large power applications. This paper discusses circuit designs using these devices that are suitable for PCS in photovoltaic and other industrial applications such as electrical appliances, instrumentation, AC motor drives, battery chargers, automobiles, telecommunications, UPS, and switch mode power supplies. It examines the cost of high volume production and current technological barriers asociated with the development of these technologies.

smart↗

Internal photoemission in Ag-Al2O3-Al junctions

The magnitude of the photon-induced current in Ag-Al2O3-Al metal-oxide-metal junctions has been studied as a function of photon energy and angle of incident radiation. Photocurrents were theoretically analyzed on the basis of a modified vacuum photoemission model (Jain, 1975; Slayman et al., to be published). Optical constants previously reported in the literature (Irani et al., 1971; Ehnrereich et al., 1963) were used to calculate the true spatial generation rate in Ag and Al as a function of the angle, polarization of incident radiation, and film thickness. Results were found to be in very good agreement with experimentally determined values for a tunable dye laser with a KDP doubling crystal pumped by a Q-switched Nd:YAG laser with a LiIO3 doubling crystal. The system provided risetimes of 50 ns or less and peak powers of 10 W. Under short circuit conditions, the photoresponse to incident power was linear up to available power densities of 10 kW/sq cm. Quantum efficiencies of about 0.1% at zero-bias, near 3.8 eV under P polarization, were typically observed.

Guedes, J. M. P.↗

Overload protection system for power inverter

An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

Nagano, S.↗

Static DC to DC Power Conditioning-Active Ripple Filter, 1 MHZ DC to DC Conversion, and Nonlinear Analysis

Dc to dc static power conditioning systems on unmanned spacecraft have as their inputs highly fluctuating dc voltages which they condition to regulated dc voltages. These input voltages may be less than or greater than the desired regulated voltages. The design of two circuits which address specific problems in the design of these power conditioning systems and a nonlinear analysis of one of the circuits are discussed. The first circuit design is for a nondissipative active ripple filter which uses an operational amplifier to amplify and cancel the sensed ripple voltage. A dc to dc converter operating at a switching frequency of 1 MHz is the second circuit discussed. A nonlinear analysis of the type of dc to dc converter utilized in designing the 1 MHz converter is included.

Sander, W. A., III↗

Experiment definition phase shuttle laboratory: LDRL-10.6 experiment

Progress is reported in the development of the space shuttle laboratory laser data relay link. The system transmittance of various surfaces was considered in order to examine the coating tradeoffs for the beryllium mirrors. The results of six coating combinations considered are summarized. It is recommended that silver coatings be used throughout the system. Design of the pre-expander and a preliminary alignment procedure implemented to align all optical elements to the reference mechanical axis (the rotational axis of the outer gimbal bearing located between the two Gregorian telescopes) are included. The local oscillator subsystem, consisting of the laser, Stark cell, Stark cell electronics, power supply, starting circuit, and conditioning optics were completed and installed in the optimechanical subsystem and operation against a 10.6 micrometer source was attempted. Preliminary measurements of the HgCdTe mixer showed that this critical element was inoperative and in subsequent tests the receiver front end electronics had also failed. Possible reasons for these failures and corrective action and steps to prevent future recurrence are discussed.

Source record↗

Gas Flow Detection System

This system provides a portable means to detect gas flow through a thin-walled tube without breaking into the tubing system. The flow detection system was specifically designed to detect flow through two parallel branches of a manifold with only one inlet and outlet, and is a means for verifying a space shuttle program requirement that saves time and reduces the risk of flight hardware damage compared to the current means of requirement verification. The prototype Purge Vent and Drain Window Cavity Conditioning System (PVD WCCS) Flow Detection System consists of a heater and a temperature-sensing thermistor attached to a piece of Velcro to be attached to each branch of a WCCS manifold for the duration of the requirement verification test. The heaters and thermistors are connected to a shielded cable and then to an electronics enclosure, which contains the power supplies, relays, and circuit board to provide power, signal conditioning, and control. The electronics enclosure is then connected to a commercial data acquisition box to provide analog to digital conversion as well as digital control. This data acquisition box is then connected to a commercial laptop running a custom application created using National Instruments LabVIEW. The operation of the PVD WCCS Flow Detection System consists of first attaching a heater/thermistor assembly to each of the two branches of one manifold while there is no flow through the manifold. Next, the software application running on the laptop is used to turn on the heaters and to monitor the manifold branch temperatures. When the system has reached thermal equilibrium, the software application s graphical user interface (GUI) will indicate that the branch temperatures are stable. The operator can then physically open the flow control valve to initiate the test flow of gaseous nitrogen (GN2) through the manifold. Next, the software user interface will be monitored for stable temperature indications when the system is again at thermal equilibrium with the test flow of GN2. The temperature drop of each branch from its "no flow" stable temperature peak to its stable "with flow" temperature will allow the operator to determine whether a minimum level of flow exists. An alternative operation has the operator turning on the software only long enough to record the ambient temperature of the tubing before turning on the heaters and initiating GN2 flow. The stable temperature of the heated tubing with GN2 flow is then compared with the ambient tubing temperature to determine if flow is present in each branch. To help quantify the level of flow in the manifolds, each branch will be bench calibrated to establish its thermal properties using the flow detection system and different flow rates. These calibration values can then be incorporated into the software application to provide more detailed flow rate information.

Moss, Thomas↗

Design study of a high power rotary transformer

A design study was made on a rotary transformer for transferring electrical power across a rotating spacecraft interface. The analysis was performed for a 100 KW, 20 KHz unit having a ""pancake'' geometry. The rotary transformer had a radial (vertical) gap and consisted of 4-25 KW modules. It was assumed that the power conditioning comprised of a Schwarz resonant circuit with a 20 KHz switching frequency. The rotary transformer, mechanical and structural design, heat rejection system and drive mechanism which provide a complete power transfer device were examined. The rotary transformer losses, efficiency, weight and size were compared with an axial (axial symmetric) gap transformer having the same performance requirements and input characteristics which was designed as part of a previous program. The ""pancake'' geometry results in a heavier rotary transformer primarily because of inefficient use of the core material. It is shown that the radial gap rotary transformer is a feasible approach for the transfer of electrical power across a rotating interface and can be implemented using presently available technology.

Weinberger, S. M.↗