Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER CONDITIONING CIRCUITS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A mechatronic power boosting design for piezoelectric generators

It was shown that the piezoelectric power generation can be boosted by using the synchronized switch power conditioning circuits. This letter reports a self-powered and self-sensing mechatronic design in substitute of the auxiliary electronics towards a compact and universal synchronized switch solution. The design criteria are derived based on the conceptual waveforms and a two-degree-of-freedom analytical model. Experimental result shows that, compared to the standard bridge rectifier interface, the mechatronic design leads to an extra 111% increase of generated power from the prototyped piezoelectric generator under the same deflection magnitude excitation. The proposed design has introduced a valuable physical insight of electromechanical synergy towards the improvement of piezoelectric power generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High performance protection circuit for power electronics applications

In this paper we present a high performance protection circuit designed for the power electronics applications where the load currents can increase rapidly and exceed the maximum allowed values, like in the case of high frequency induction heating inverters or high frequency plasma generators. The protection circuit is based on a microcontroller and can be adapted for use on single-phase or three-phase power systems. Its versatility comes from the fact that the circuit can communicate with the protected system, having the role of a “sensor” or it can interrupt the power supply for protection, in this case functioning as an external, independent protection circuit.

42 ENGINEERING↗

AN UPDATE ON NIF PULSED POWER

The National Ignition Facility (NIF) is a 192-beam laser fusion driver operating at Lawrence Livermore National Laboratory. NIF relies on three large-scale pulsed power systems to achieve its goals: the Power Conditioning Unit (PCU), which provides flashlamp excitation for the laser's injection system; the Power Conditioning System (PCS), which provides the multi-megajoule pulsed excitation required to drive flashlamps in the laser's optical amplifiers; and the Plasma Electrode Pockels Cell (PEPC), which enables NIF to take advantage of a fourpass main amplifier. Years of production, installation, and commissioning of the three NIF pulsed power systems are now complete. Seven-day-per-week operation of the laser has commenced, with the three pulsed power systems providing routine support of laser operations. We present the details of the status and operational experience associated with the three systems along with a projection of the future for NIF pulsed power.

42 ENGINEERING↗

Real-time Condition Monitoring of Power Modules in Grid-tied Power Converter

This paper proposes and demonstrates a real-time condition monitoring method using gate driver integrated sensing circuits and sensor fusion algorithms. Power device on-state voltage (VDSon) measurement and junction temperature (Tj) sensing circuits with high noise immunity are built and integrated into an adaptive gate driver circuit for power modules. Considering the inherently noisy measurement environment of power converters, VDSon together with several other measurements are fused together to provide accurate descriptions of the stress and degradation of each power device. Furthermore, the gate driver circuit can actively control the turn-on gate voltage (VGSon) for each device based on the stress and degradation state. The proposed sensing circuits and power device condition assessment algorithms are implemented in a 75 KVA grid-tied power converter. This paper focuses on the sensing circuits hardware designs and testing in grid-tied power converter prototype and device stress index generation. More comprehensive results on the device state of health index generation will be presented in future work.

Fan, Junchong↗

A study on the maximum power transfer condition in an inductively coupled plasma using transformer circuit model

Correlations between the external discharge parameters (the driving frequency ω and the chamber dimension R) and plasma characteristics (the skin depth δ and the electron-neutral collision frequency ν{sub m}) are studied using the transformer circuit model [R. B. Piejak et al., Plasma Sources Sci. Technol. 1, 179 (1992)] when the absorbed power is maximized in an inductively coupled plasma. From the analysis of the transformer circuit model, the maximum power transfer conditions, which depend on the external discharge parameters and the internal plasma characteristics, were obtained. It was found that a maximum power transfer occurs when δ≈0.38R for the discharge condition at which ν{sub m}/ω≪1, while it occurs when δ≈√(2)√(ω/ν{sub m})R for the discharge condition at which ν{sub m}/ω≫1. The results of this circuit analysis are consistent with the stable last inductive mode region of an inductive-to-capacitive mode transition [Lee and Chung, Phys. Plasmas 13, 063510 (2006)], which was theoretically derived from Maxwell's equations. Our results were also in agreement with the experimental results. From this work, we demonstrate that a simple circuit analysis can be applied to explain complex physical phenomena to a certain extent.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high efficiency photovoltaic module integrated converter with the asymmetrical half-bridge flyback converter

A module integrated converter (MIC) for a photovoltaic (PV) cell is important part of power conditioning system (PCS). It performs maximum power point tracking of a PV cell to generate the power as much as possible from solar energy. There are several methods for connection between the PV modules and the MICs. In order to avoid partial shading effects, converter-per-module approach was proposed. The MIC that performs maximum power point tracking (MPPT), if it is low efficiency, is no use. The MIC whose output is connected to the output of PV module was proposed for high efficiency. However, there are some problems. In this study, an asymmetrical half-bridge flyback converter is proposed instead of the original flyback converter with same method to solve the problems. The proposed MIC was built to verify the performance. The new topology using soft switching technique showed good performance for the efficiency. At the higher power, the efficiency of the proposed converter is higher than existing converter. (author)

14 SOLAR ENERGY↗

Back-Up/ Peak Shaving Fuel Cell System

This Final Report covers the work executed by Plug Power from 8/11/03 – 10/31/07 statement of work for Topic 2: advancing the state of the art of fuel cell technology with the development of a new generation of commercially viable, stationary, Back-up/Peak-Shaving fuel cell systems, the GenCore II. The Program cost was $7.2 M with the Department of Energy share being $3.6M and Plug Power’s share being $3.6 M. The Program started in August of 2003 and was scheduled to end in January of 2006. The actual program end date was October of 2007. A no cost extension was grated. The Department of Energy barriers addressed as part of this program are: Technical Barriers for Distributed Generation Systems: o Durability o Power Electronics o Start up time Technical Barriers for Fuel Cell Components: o Stack Material and Manufacturing Cost o Durability o Thermal and water management Background The next generation GenCore backup fuel cell system to be designed, developed and tested by Plug Power under the program is the first, mass-manufacturable design implementation of Plug Power’s GenCore architected platform targeted for battery and small generator replacement applications in the telecommunications, broadband and UPS markets. The next generation GenCore will be a standalone, H2 in-DC-out system. In designing the next generation GenCore specifically for the telecommunications market, Plug Power is teaming with BellSouth Telecommunications, Inc., a leading industry end user. The final next generation GenCore system is expected to represent a market-entry, mass-manufacturable and economically viable design. The technology will incorporate: • A cost-reduced, polymer electrolyte membrane (PEM) fuel cell stack tailored to hydrogen fuel use • An advanced electrical energy storage system • A modular, scalable power conditioning system tailored to market requirements • A scaled-down, cost-reduced balance of plant (BOP) • Network Equipment Building Standards (NEBS), UL and CE certifications.

08 HYDROGEN↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Characterization of power IGBTs under pulsed power conditions

The power insulated gate bipolar transistor (IGBT) is used in many types of applications. Although the use of the power IGBT has been well characterized for many continuous operation power electronics applications, little published information is available regarding the performance of a given IGBT under pulsed power conditions. Additionally, component libraries in circuit simulation software packages have a finite number of IGBTs. This paper presents a process for characterizing the performance of a given power IGBT under pulsed power conditions. Specifically, signals up to 3.5 kV and 1 kA with 1-10 {micro}s pulse widths have been applied to a Powerex QIS4506001 IGBT. This process utilizes least squares curve fitting techniques with collected data to determine values for a set of modeling parameters. These parameters were used in the Oziemkiewicz implementation of the Hefner model for the IGBT that is utilized in some circuit simulation software packages. After the nominal parameter values are determined, they can be inserted into the Oziemkiewicz implementation to simulate a given IGBT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Converter-Based Transmission Line Emulator with Three-Phase Short-Circuit Fault Emulation Capability

A transmission line emulator has been developed to flexibly represent interconnected ac lines under normal operating conditions in a voltage source converter (VSC)-based power system emulation platform. As the most serious short-circuit fault condition, the three-phase short-circuit fault emulation is essential for power system studies. Here, this paper proposes a model to realize a three-phase short-circuit fault emulation at different locations along a single transmission line or one of several parallel-connected transmission lines. At the same time, a combination method is proposed to eliminate the undesired transients caused by the current reference step changes while switching between the fault state and the normal state. Experiment results verify the developed transmission line three-phase short-circuit fault emulation capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Harvesting Wave Energy to Power Acoustic Transmitters Using Triboelectric Nanogenerator

Wave energy has the largest reserves and widest distribution among blue energy sources. However, the conversion and utilization of ocean wave energy are challenging. In this work, we developed a contact-separation mode triboelectric nanogenerator (TENG) with a simple structure for harvesting wave energy and powering marine sensors and transmitters and performed detailed electrical characterization under controlled laboratory conditions. A prototype power management circuit (PMC) was implemented to improve the output performance of the TENG. The output from the PMC could charge up a storage capacitor for powering sensors and electronics. Eventually, the TENG was integrated within a water-proof enclosure and tested using a custom-built wave simulator to evaluate the device performance in a more representative scenario. The device sustainably powered up an array of 27 LEDs and was able to charge up a capacitor up to 1.8 V for driving an acoustic transmitter. The results demonstrate that TENG technology shows great promise in harvesting low-frequency ocean wave energy.

Yang, Yang↗

Theoretical Analysis and Experimental Validation of Flying-Capacitor Multilevel Converters Under Short-Circuit Fault Conditions

Addressing the increasing demand for high- efficiency and high-power-density converters, the flying-capacitor multilevel converter has shown itself as a promising topology. A key advantage of this topology is the reduced voltage rating of the switches, though also makes it vulnerable to device failure during short-circuit conditions. Despite large interest in fault-tolerant operation of these converters, alongside detailed descriptions of flying capacitor balancing, little research has focused on the converter short-circuit fault analysis, which may cause a switch failure if not properly designed for. Therefore, this work presents a comprehensive model describing the large- signal short-circuit switching behavior of a general N -level flying- capacitor multilevel converter. Highly simplified models used to predict the evolution of the switch current and voltage stress during the fault are proposed, targeted at practicing engineers for conservative design guidelines. These models are used to determine the critical time for remedial action of the converter before reaching some predefined maximum conditions. A 2-to-10- level fully-configurable flying-capacitor multilevel converter and a fault circuit hardware prototype are used to experimentally perform different short-circuit tests that show a good match to the measured behavior.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detector and Readout Assembly and Characterization for the Simons Array

The Simons Array (SA) is a cosmic microwave background (CMB) polarization experiment comprised of three telescopes that will observe the CMB at 90, 150, 220, and 270GHz with more than 22,000 Transition Edge Sensor (TES) bolometers. The cryogenic receivers inside each telescope are named POLARBEAR-2a, POLARBEAR-2b, and POLARBEAR-2c (PB-2a, PB-2b, and PB-2c, respectively). To allow for the large number of detectors, SA uses frequency-division multiplexing with multiplexing factor of 40. We describe the process developed to assemble the readout circuit repeatably for SA. After assembly, we characterize the readout circuit and TESs at cryogenic temperatures in a condition of negligible incident optical power. Impedances in the readout circuit bias our estimates of TES parameters, and we describe a method to account for this.

cosmic microwave background↗

Plasma Switch for High-Power Active Pulse Compressor

Results are presented from experiments carried out at the Naval Research Laboratory X-band magnicon facility on a two-channel X-band active RF pulse compressor that employed plasma switches. Experimental evidence is shown to validate the basic goals of the project, which include: simultaneous firing of plasma switches in both channels of the RF circuit, operation of quasi-optical 3-dB hybrid directional coupler coherent superposition of RF compressed pulses from both channels, and operation of the X-band magnicon directly in the RF pulse compressor. For incident 1.2 μs pulses in the range 0.63 - 1.35 MW, compressed pulses of peak powers 5.7 - 11.3 MW were obtained, corresponding to peak power gain ratios of 8.3 - 9.3. Insufficient bakeout and conditioning of the high-power RF circuit prevented experiments from being conducted at higher RF input power levels.

43 PARTICLE ACCELERATORS↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗