Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

THE INFLUENCE OF DISSIPATION RANGE POWER SPECTRA AND PLASMA-WAVE POLARIZATION ON COSMIC-RAY SCATTERING MEAN FREE PATH

The influence of the polarization state and the dissipation range spectral steepening of slab plasma waves on the scattering mean free path of single-charged cosmic-ray particles is investigated in a turbulence model, where the crucial scattering of cosmic-ray particles with small pitch-angle cosines is caused by resonant cyclotron interactions with slab plasma waves. Analytical expressions for the mean free path of protons, antiprotons, negatrons, and positrons are derived for the case of constant frequency-independent magnetic helicity values {sigma} and different values of the dissipation range spectral index k for characteristic interplanetary and interstellar plasma conditions. The positron mean free path is not affected by the dissipation range spectral index k as these particles can only cyclotron-resonate for rigidity values larger than R {sub 0} = m{sub p}c = 938 MV. Proton and antiproton mean free paths are only slightly affected by the dissipation range spectral index k at small rigidities R < R {sub 0}. The negatron mean free path is severely affected by the dissipation range spectral index k at rigidities smaller than R {sub 0}. At high rigidities R >> R {sub 0}, all particle species approach the same power-law dependence {proportional_to}R {sup 2-s} determined by the inertial range spectral index s = 5/3. The magnetic helicity value {sigma} affects the value of the mean free path. At all rigidities, the ratio of the antiproton to proton mean free paths equals the constant (1 + {sigma})/(1 - {sigma}), which also agrees with the ratio of the negatron to the proton and positron mean free paths at relativistic rigidities. At relativistic rigidities the positron and proton mean free paths agree, as do the negatron and antiproton mean free paths.

79 ASTRONOMY AND ASTROPHYSICS↗

Winding Schemes for Wide Constant Power Range of Double Stator Transverse Flux Machine

Different ring winding schemes for double sided transverse flux machines are investigated in this paper for wide speed operation. The windings under investigation are based on two inverters used in parallel. At higher power applications this arrangement improves the drive efficiency. The new winding structure through manipulation of the end connection splits individual sets into two and connects the partitioned turns from individual stator sets in series. This configuration offers the flexibility of torque profiling and a greater flux weakening region. At low speeds and low torque only one winding set is capable of providing the required torque thus providing greater fault tolerance. At higher speeds one set is dedicated to torque production and the other for flux control. The proposed method improves the machine efficiency and allows better flux weakening which is desirable for traction applications.

17 WIND ENERGY↗

SU-G-TeP1-02: Analytical Stopping Power and Range Parameterization for Therapeutic Energy Intervals

Purpose: To develop a simple, analytic parameterization of stopping power and range, which covers a wide energy interval and is applicable to many species of projectile ions and target materials, with less than 15% disagreement in linear stopping power and 1 mm in range. Methods: The new parameterization was required to be analytically integrable from stopping power to range, and continuous across the range interval of 1 µm to 50 cm. The model parameters were determined from stopping power and range data for hydrogen, carbon, iron, and uranium ions incident on water, carbon, aluminum, lead and copper. Stopping power and range data was taken from SRIM. A stochastic minimization algorithm was used to find model parameters, with 10 data points per energy decade. Additionally, fitting was performed with 2 and 26 data points per energy decade to test the model’s robustness to sparse Results: 6 free parameters were sufficient to cover the therapeutic energy range for each projectile ion species (e.g. 1 keV – 300 MeV for protons). The model agrees with stopping power and range data well, with less than 9% relative stopping power difference and 0.5 mm difference in range. As few as, 4 bins per decade were required to achieve comparable fitting results to the full data set. Conclusion: This study successfully demonstrated that a simple analytic function can be used to fit the entire energy interval of therapeutic ion beams of hydrogen and heavier elements. Advantages of this model were the small number (6) of free parameters, and that the model calculates both stopping power and range. Applications of this model include GPU-based dose calculation algorithms and Monte Carlo simulations, where available memory is limited. This work was supported in part by a research agreement between United States Naval Academy and Louisiana State University: Contract No N00189-13-P-0786. In addition, this work was accepted for presentation at the American Nuclear Society Annual Meeting 2016.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analytical Stopping Power and Range Parameterization for Therapeutic Energy Intervals

The literature on stopping powers and ranges for proton and heavier ions is vast. It includes measurements, theory, evaluations and tabulations, and software programs and routines. Electronic stopping powers are typically calculated with either the Bethe-Bloch Equation or empirically derived functions, depending on the energy regime of the ion. Nuclear stopping powers are typically calculated using a theoretical approach. Ranges are commonly calculated numerically using path length integration, stopping power data and the continuous slowing down approximation. The Stopping and Ranges of Ions in Matter (SRIM) by Ziegler et al., which provides these and other capabilities, exemplifies the integration of highly-realistic theories, evaluated data, and radiation transport capabilities. In applications where speed and simplicity are paramount considerations, analytical calculations of range offer considerable advantages over numerical methods. Range has long been calculated analytically using a simple power law known as the range-energy relationship. This provides excellent accuracy over a surprisingly wide interval of ion species (e.g. protons, carbon), ion energies (e.g. 10-200 MeV/u), absorber compositions (e.g. plastic, water, metal), and thickness (e.g. 0.5-1 10 mm). The major limitation of formulas derived from a simple power law relation was their limited interval of applicability, 1.e., 10-200 MeV for protons in water. Thus, fora projectile in a stopping length target, such as a cancer patient, the simple power law model breaks down in the biologically important interval below 10 MeV. In current standard-of-care treatment planning, this is typically not a concern because the resulting range errors are less than 1 mm (and can be accounted for) and because biological effects are not calculated based on ion stopping power. However, there is considerable interest to perform multi-scale calculations of ion beams, e.g., at dimensions corresponding to cellular DNA, with ion energies below 10 MeV. Thus, there is an increasing need for new fast and simple formulae to calculate range and stopping power across a broader energy intervals of ion energy. It was not known if simple analytical equations would meet this need and, if so, the limits of their applicability. The aim of this work was to develop a simple, non-piecewise continuous model of total stopping power which could be analytically integrated to provide a simple formula for range. More specifically, we sought to develop a model to provide stopping powers with accuracy of better than 20% and range errors less than 1 mm for hydrogen, carbon, iron, and uranium projectile ions and target materials including water, carbon, aluminum, lead, copper, iron, gadolinium, and gold. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incentivizing Flexibility in System Operations

Defining flexibility has been a challenge that a number of industry members and researchers have attempted to address in recent years. With increased variability and uncertainty of variable generation (VG), the resources on the system will have to be more flexible to adjust output, so that power output ranges, power ramp rates, and energy duration sustainability are sufficient to meet the needs of balancing supply with demand at various operational timescales. This chapter discusses whether existing market designs provide adequate incentives for resources to offer their flexibility into the market to meet the increased levels of variability and uncertainty introduced by VG in the short-term operational time frame. It presents a definition of flexibility and discusses how increased levels of VG require increased needs for flexibility on power systems. Following this introductory material, the chapter examines how existing market designs ensure that resources have the right incentives to provide increased flexibility, and then discusses a number of emerging market design elements that impact flexibility incentives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Correlation of plasma characteristics to etch rate and via sidewall angle in a deep reactive ion etch system using Langmuir probe and optical emission spectroscopy

A Langmuir probe and optical emission spectroscopy were used in a deep reactive ion etch system to correlate plasma parameters (atomic fluorine and argon emission, electron density, ion density, and electron average energy) with the etch rate and via sidewall angle. All data were obtained for coil powers ranging from 200 to 800 W, platen powers ranging from 7 to 16 W, and pressure ranging from 3.8 to 62 mTorr with constant SF{sub 6} and Ar flow rates of 112 and 18 SCCM (SCCM denotes cubic centimeter per minute at STP), respectively. Results indicate that there is a correlation with etch rate for all plasma parameters except for argon emission. For argon emission, the etch rate exhibits a double-valued relation where the etch rate can either increase or decrease with increasing argon emission intensity due to changes in pressure which affect the energy coupling efficiency. As expected, the etch rate increases for measured increases in fluorine emission, electron density, and ion density. The etch rate, however, decreases with increasing average electron energy due to collision processes. In contrast, no correlation is observed between any of the measured plasma parameters with sidewall angle. The last result is consistent with the idea that sidewall angle is primarily controlled by the passivation cycle as opposed to the etching cycle, where all the authors' data were obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Techniques for Achieving High Reliability Operation of the Spallation Neutron Source High Power Radio-Frequency System

The Spallation Neutron Source (SNS) high power radiofrequency (HPRF) system operates with high reliability to support the goals of the SNS user program. In recent operational periods the availability of the HPRF system has exceeded 97 percent while the neutron source availability overall is typically greater than 90 percent. SNS has a unique set of 92 HPRF stations that operate at either 402.5 MHz or 805 MHz with peak output power ranging from 550 kW to 5 MW and average power ranging from 49.5 kW to 450 kW. The HPRF transmitters consist of chassis-mounted power supplies, solid-state amplifiers and other equipment that support the operation of the klystrons that ultimately provide the RF power to the accelerating structures. Management of the operation and maintenance of the HPRF system has increasingly focused on reliability and sustainability in recent years. Techniques for klystron lifetime preservation and optimization of transmitter reliability have been developed and will be described.

Moss, John↗

An RF dosimeter for independent SAR measurement in MRI scanners

Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on average independent of the imaging subject, albeit with fluctuations. Conclusions: Our 3T RF dosimeter and transducers accurately measure RF exposure in body-equivalent loads and provide scanner-independent assessments of whole-body RF power deposition for establishing safety compliance useful for MRI sequence and device testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Harmonic cancellation within AC low voltage distribution for a realistic office environment

An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radio frequency plasma power dependence of the moisture permeation barrier characteristics of Al{sub 2}O{sub 3} films deposited by remote plasma atomic layer deposition

In the present study, we investigated the gas and moisture permeation barrier properties of Al{sub 2}O{sub 3} films deposited on polyethersulfone films (PES) by capacitively coupled plasma (CCP) type Remote Plasma Atomic Layer Deposition (RPALD) at Radio Frequency (RF) plasma powers ranging from 100 W to 400 W in 100 W increments using Trimethylaluminum [TMA, Al(CH{sub 3}){sub 3}] as the Al source and O{sub 2} plasma as the reactant. To study the gas and moisture permeation barrier properties of 100-nm-thick Al{sub 2}O{sub 3} at various plasma powers, the Water Vapor Transmission Rate (WVTR) was measured using an electrical Ca degradation test. WVTR decreased as plasma power increased with WVTR values for 400 W and 100 W of 2.6 × 10{sup −4} gm{sup −2}day{sup −1} and 1.2 × 10{sup −3} gm{sup −2}day{sup −1}, respectively. The trends for life time, Al-O and O-H bond, density, and stoichiometry were similar to that of WVTR with improvement associated with increasing plasma power. Further, among plasma power ranging from 100 W to 400 W, the highest power of 400 W resulted in the best moisture permeation barrier properties. This result was attributed to differences in volume and amount of ion and radical fluxes, to join the ALD process, generated by O{sub 2} plasma as the plasma power changed during ALD process, which was determined using a plasma diagnosis technique called the Floating Harmonic Method (FHM). Plasma diagnosis by FHM revealed an increase in ion flux with increasing plasma power. With respect to the ALD process, our results indicated that higher plasma power generated increased ion and radical flux compared with lower plasma power. Thus, a higher plasma power provides the best gas and moisture permeation barrier properties.

36 MATERIALS SCIENCE↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Energy dynamics and current sheet structure in fluid and kinetic simulations of decaying magnetohydrodynamic turbulence

Simulations of decaying magnetohydrodynamic (MHD) turbulence are performed with a fluid and a kinetic code. The initial condition is an ensemble of long-wavelength, counter-propagating, shear-Alfvén waves, which interact and rapidly generate strong MHD turbulence. The total energy is conserved and the rate of turbulent energy decay is very similar in both codes, although the fluid code has numerical dissipation, whereas the kinetic code has kinetic dissipation. The inertial range power spectrum index is similar in both the codes. The fluid code shows a perpendicular wavenumber spectral slope of k{sub ⊥}{sup −1.3}. The kinetic code shows a spectral slope of k{sub ⊥}{sup −1.5} for smaller simulation domain, and k{sub ⊥}{sup −1.3} for larger domain. We estimate that collisionless damping mechanisms in the kinetic code can account for the dissipation of the observed nonlinear energy cascade. Current sheets are geometrically characterized. Their lengths and widths are in good agreement between the two codes. The length scales linearly with the driving scale of the turbulence. In the fluid code, their thickness is determined by the grid resolution as there is no explicit diffusivity. In the kinetic code, their thickness is very close to the skin-depth, irrespective of the grid resolution. This work shows that kinetic codes can reproduce the MHD inertial range dynamics at large scales, while at the same time capturing important kinetic physics at small scales.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Evaluation of Grid Support Enabled PV Inverter Response to Abnormal Grid Conditions

As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and voltage/frequency ride-through, among others. This paper describes the results of a comparative experimental evaluation on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and its effect on abnormal grid condition response. The evaluation examined the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. Testing results indicated a wide variance in the performance of GSF enabled inverters to various test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Erbium gain effects on Stokes signal performance in a Fabry–Perot Brillouin Erbium fiber laser

The effect of the Erbium gain on the Stokes signal performance is experimentally presented in this paper. Linear Brilllouin Erbium fiber laser cavity is tested under different 1480 nm pump power ranges (0–125 mW). Different Brillouin pump (Bp) power values of 2, 4 and 6 dBm are used in this study. Stokes signal net gain and threshold power are recorded at all generated Stokes signals for these Bp powers values. 2 dBm Bp power shows higher net gain, low threshold, large Stokes numbers and low required 1480 nm pump power compared to 4 and 6 dBm. Up to 8.3 dB net gain, threshold of − 10.3 dBm, 24 Stokes signals and with a maximum 1480 nm pump power of 92.2 mW are recorded for 2 dBm Bp power. Stokes signal threshold is recorded at the near end of the single mode fiber at which Nth order Stokes is generated.

42 ENGINEERING↗

Long range inductive power transfer with superconducting oscillators

Resonant inductive power transfer has demonstrated the transfer of 60 W at distances in excess of 2 m with as much as 40% efficiency. The loss mechanisms include internal dissipation and radiated power. By constructing superconducting oscillators and operating at lower frequencies, both of these loss mechanisms are reduced, and this same power can be transferred at distances in excess of 100 m. A performance analysis of such a system is presented, along with proposed low-loss coil and capacitor designs to achieve this performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiport Control with Partial Power Processing in Solid-State Transformer for PV, Storage, and Fast-Charging Electric Vehicle Integration

This article proposes a multiport control method to enable partial power processing (PPP) in a medium-voltage (MV) multiport solid-state transformer (SST). MV multiport SSTs are promising in integrating low-voltage DC sources or loads such as solar photovoltaic, energy storage, and electric vehicles into smart grids without bulky line-frequency transformers. Compared to voltage-source SST, current-source (CS) SST features single-stage isolated bidirectional AC/AC, AC/DC, or DC/DC conversion using an inductive DC link. For a multiport CS SST, it is revealed in this article that the PPP capability can be enabled through the proposed control without extra hardware, different from the case of voltage-source converters where special hardware architecture is required for the PPP. With the PPP, most power exchange between LV ports is processed by only a fraction of the entire conversion stage, leading to reduced DC-link current, volume, loss, and improved efficiency. The proposed multiport PPP control scheme is analyzed to verify the advantages across a wide voltage and power range against conventional full power processing (FPP) multiport control, using the soft-switching solid-state transformer (S4T) with reduced conduction loss as an example. Comparative experimental results based on a SiC three-port S4T prototype verify the effectiveness of the proposed PPP scheme against the FPP scheme under both steady state and dynamic conditions. Here, the DC-link current reduction is measured to be more than 36%. Significantly, the proposed multiport PPP control scheme is generic and applicable to any hard-switching or soft-switching CS SSTs without extra hardware.

14 SOLAR ENERGY↗