Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER TRANSMISSION LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of Power Transmission Lines Hardening Scenarios Using a Machine Learning Approach

The power transmission infrastructure is vulnerable to extreme weather events, particularly hurricanes and tropical storms. A recent example is the damage caused by Hurricane Maria (H-Maria) in the archipelago of Puerto Rico in September 2017, where major failures in the transmission infrastructure led to a total blackout. Numerous studies have been conducted to examine strategies to strengthen the transmission system, including burying the power lines underground or increasing the frequency of tree trimming. However, few studies focus on the direct hardening of the transmission towers to accomplish an increase in resiliency. This machine learning-based study fills this need by analyzing three direct hardening scenarios and determining the effectiveness of these changes in the context of H-Maria. A methodology for estimating transmission tower damage is presented here in this study as well as an analysis of impact of replacing structures with a high failure rate with more resilient ones. We found the steel self-support-pole to be the best replacement option for the towers with high failure rate. Furthermore, the third hardening scenario, where all wooden poles were replaced, exhibited a maximum reduction in damaged towers in a single line of 66% while lowering the mean number of damaged towers per line by 10%.

54 ENVIRONMENTAL SCIENCES↗

TCSR Features Ensuring the Prevention of Voltage Resonance During Power Transmission Line Single Phase Auto-Reclosing

A description is provided of the operating mode of a line equipped with a thyristor-controlled shunt reactor (TCSR) with split valve-side windings, in a single-phase ARC (SPAR) cycle after arc quenching. It is shown that a TCSR is sufficiently fast to prevent the development of resonant overvoltages in the open-phase operating mode of a power transmission line (PTL).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Supervised classification of electric power transmission line nominal voltage from high-resolution aerial imagery

For many researchers, government agencies, and emergency responders, access to the geospatial data of US electric power infrastructure is invaluable for analysis, planning, and disaster recovery. Historically, however, access to high quality geospatial energy data has been limited to few agencies because of commercial licenses restrictions, and those resources which are widely accessible have been of poor quality, particularly with respect to reliability. Recent efforts to develop a highly reliable and publicly accessible alternative to the existing datasets were met with numerous challenges – not the least of which was filling the gaps in power transmission line voltage ratings. To address the line voltage rating problem, we developed and tested a basic methodology that fuses knowledge and techniques from power systems, geography, and machine learning domains. Specifically, we identified predictors of nominal voltage that could be extracted from aerial imagery and developed a tree-based classifier to classify nominal line voltage ratings. Overall, we found that line support height, support span, and conductor spacing are the best predictors of voltage ratings, and that the classifier built with these predictors had a reliable predictive accuracy (that is, within one voltage class for four out of the five classes sampled). In conclusion, we applied our approach to a study area in Minnesota.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Millimeter-Gap Magnetically Insulated Transmission Line Power Flow Experiments

An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs). The platform was driven by the 400-GW Mykonos-V accelerator. The experiments conducted quantify the current loss in a millimeter-gap MITL with respect to vacuum conditions in the MITL for two different gap distances, 1.0 and 1.3 mm. The current loss for each gap was measured for three different vacuum pump down times. As a ride along experiment, multiple shots were conducted with each set of hardware to determine if there was a conditioning effect to increase current delivery on subsequent shots. The experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps. The 1.0 mm gap resulted in current loss of 40%-60% of peak current. The 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps. The experiments result s indicate that the vacuum pressure or pump down time did not have a significant effect on the measured current loss at vacuum pressures between 1e-4 and 1e-5 Torr. Additionally, there was not repeatable evidence of a conditioning effect that reduced current loss for subsequent full-energy shots on a given set of hardware. It should be noted that the experiments conducted likely did not have large loss contributions due to ion emission from the anode due to the relatively small current densi-ties (25-40 kA/cm) in the MITL that limited the anode temperature rise due to ohmic heating. The results and conclusions from these experiments may have limited applicability to MITLs of high current density (>400 kA/cm) used in the convolute and load region of the Z which experience temperature increases of >400° C and generate ion emission from anode surfaces.

42 ENGINEERING↗

Additively manufactured electrodes for plasma and power-flow studies in high-power transmission lines on the 1-MA MAIZE facility

Power-flow studies on the 30-MA, 100-ns Z facility at Sandia National Laboratories have shown that plasmas in the facility’s magnetically insulated transmission lines (MITLs) and double post-hole convolute can result in a loss of current delivered to the load. To study power-flow physics on the 1-MA, 100-ns MAIZE facility at the University of Michigan, planar MITL loads and planar post-hole convolute loads have been developed that extend into the lines of sight for various imaging diagnostics on MAIZE. These loads use 3D-printed dielectric support structures lined with thin foils of either aluminum or stainless steel. Here, the metal foils serve as the current-carrying power-flow surfaces, which generate plasma during the current pulse. The foil thickness (50 µm) and widths (11.5–16 mm) are selected to ensure a sufficient linear current density (0.5–0.7 MA/cm) for plasma formation. Laser backlighting (532 nm) and visible-light self-emission imaging capture the overall plasma evolution in the anode–cathode gaps, including the gap closure velocities (1–4 cm/μs).

47 OTHER INSTRUMENTATION↗

Test Results from a Simulated High Voltage Lunar Power Transmission Line

The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was modified to simulate high voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high frequency AC power to a lunar facility located at a distance.

Birchenough, Arthur↗

Test Results From a Simulated High-Voltage Lunar Power Transmission Line

The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio was modified to simulate high-voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high-frequency ac power to a lunar facility located at a distance.

Birchenough, Arthur↗

A study of electric power transmission lines for use on the lunar surface

Analytical models have been developed to study the operating characteristics of electrical transmission lines for use on the lunar surface. Important design considerations for a transmission line operating on the lunar surface are mass, temperature, and efficiency. Transmission line parameters which impact these considerations include voltage, power loss, and waveform. The electrical and thermal models developed are used to calculate transmission line mass, size, and temperature as a function of voltage, geometry, waveform, location, and efficiency. The analyses include ac and dc for above and below ground operation. Geometries studied include a vacuum-insulated, two-wire transmission line and a solid-dielectric insulated, coaxial transmission line. A brief discussion of design considerations and the models developed is followed by results for parameter studies for both dc and ac transmission lines.

Gordon, Lloyd B.↗

TCSR Features Facilitating Safe Testing of 500 kV Power Transmission Lines

Reasons are examined for failures of gas-insulated circuit breakers on lines with shunt reactors that provide a level of line compensation close to 100%. It is shown that using a TCSR as a linear reactor makes it possible to eliminate the reason leading to failure of the circuit breaker in line testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Longitudinal variations of very-low-frequency chorus activity in the magnetosphere - Evidence of excitation by electrical power transmission lines

The distribution of VLF chorus in the high-altitude magnetosphere as detected by the Ogo 3 satellite was investigated. Chorus occurrence frequency over 4,668 samples of 5 min of broadband data was computed for Northern Hemisphere bins of 10 deg by 10 deg in dipole invariant latitude and longitude. Peaks in activity were noted over Alaska, the eastern U.S. and Canada, western Europe, and western Siberia, and were shown not to be the result of biased sampling. It is suggested that power line radiation of only about 1 W or less at a given harmonic frequency may be sufficient to stimulate the observed chorus activity and that such power levels can be expected in industrial areas or from large distribution networks. Preliminary results show that chorus starting frequencies are highly correlated with 60 Hz harmonics in the American sector and with 50 Hz harmonics in the European sector.

Luette, J. P.↗

Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources

A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV–55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails, and a demonstrator setup installation within a NPP verify the overall performance of the proposed system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electrical Transmission on the Lunar Surface: DC Transmission - Part 1

This report summarizes a portion of the results from a grant at Auburn University to study the electrical and thermal energy management for lunar facilities. Over the past year (June 1989 to May 1990) the following topics have been investigated: June 1989 to November 1989 - Literature survey, assessment of lunar power needs, and overview study of the requirements of a lunar power system; November 1989 to April 1990 - Develop models for the study of dc electrical power transmission lines for the lunar surface; March 1990 to May 1990 - Develop models for the study of ac electrical power transmission lines for the lunar surface. Because of the large amount of information in the model development and application to a wide parameter space this report is being bound separately. This report specifically contains the model development and parameter study for dc electrical power transmission lines. The end of the funding year (May 1990) will conclude with an annual report including the literature survey, the overview of the requirements of a lunar power system, and summaries of the dc and ac models of electrical transmission lines.

Gordon, Lloyd B.↗

In-Containment Signal Conditioning and Transmission via Power Lines within High Dose Rate Areas of Nuclear Power Plants

Signal conditioning and transmission for sensor systems and networks within the containment of nuclear power plants (NPPs) still poses a challenge to engineers, particularly in the case of equipment upgrades for existing plants, temporary measurements, decommissioning of plants, but also for new builds. This paper presents an innovative method for efficient and cost-effective instrumentation within high dose rate areas inside the containment. A transmitter-receiver topology is proposed that allows simultaneous, unidirectional point-to-point transmission of multiple sensor signals by superimposing them on existing AC or DC power supply cables using power line communication (PLC) technology. Thereby the need for costly installation of additional cables and containment penetrations is eliminated. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter is designed to operate in harsh environment within the containment during full plant operation. Hardware modularity of the transmitter allows application specific tradeoffs between redundancy and channel bandwidth. At receiver side in non-radiated areas, signals are extracted from the power line, demodulated, and provided either in analog or digital output format. Laboratory qualification tests and field test results within a boiling water reactor (BWR) are validating the proof of concept of the proposed system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗