Search NASASearch

SEARCH · Search NASA

Results for “PREAMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of responsivity and noise in a direct-coupled photodetector-preamplifier for facsimile cameras

The direct-coupled (DC) mode of detector operation is evaluated for use in a facsimile camera. Photodiode-preamplifier sensitivity is described in terms of photodiode responsivity and possible noise sources resulting from the photodiode and preamplifier. Responsivity and noise limitations are experimentally verified and used to predict photodiode-preamplifier sensitivity under a wide range of operating conditions. Results demonstrate that the DC mode offers advantages in sensitivity and reduced mechanical complexity for facsimile cameras over the more common technique of chopping the radiation and ac amplifying the resultant signal.

Kelly, W. L., IV

Task three: Report: STDN Antenna and preamplifier cost tradeoff study

The general goal of this task, STDN Antenna and Preamplifier G/T Study, was to determine cost-effective combinations of antennas and preamplifiers for several sets of conditions for frequency, antenna elevation angle, and rain. The output of the study includes design curves and tables which indicate the best choice of antenna size and preamplifier type to provide a given G/T performance. The report indicates how to evaluate the cost effectiveness of proposed improvements to a given station. Certain parametric variations are presented to emphasize the improvement available by reducing RF losses and improving the antenna feed.

Source record

A Discrete Component Low-Noise Preamplifier Readout for a Linear (1x16) SiC Photodiode Array

A compact, low-noise and inexpensive preamplifier circuit has been designed and fabricated to optimally readout a common cathode (1x16) channel 4H-SiC Schottky photodiode array for use in ultraviolet experiments. The readout uses an operational amplifier with 10 pF capacitor in the feedback loop in parallel with a low leakage switch for each of the channels. This circuit configuration allows for reiterative sample, integrate and reset. A sampling technique is given to remove Johnson noise, enabling a femtoampere level readout noise performance. Commercial-off-the-shelf acquisition electronics are used to digitize the preamplifier analogue signals. The data logging acquisition electronics has a different integration circuit, which allows the bandwidth and gain to be independently adjusted. Using this readout, photoresponse measurements across the array between spectral wavelengths 200 nm and 370 nm are made to establish the array pixels external quantum efficiency, current responsivity and noise equivalent power.

low-noise preamplifier

Common antenna preamplifier-isolator for VLF-LF receivers

A modified high impedance preamplifier circuit which provides outputs to drive an Omega-VLF receiver and an ADF-LF receiver from a common antenna on general aviation aircraft is reported. The preamplifier was evaluated with fixed ground station receivers and results show the burn out problem of the first stage MOSFET during very close lightning discharges was eliminated.

Burhans, R. W.

Preamplifier Noise in VLF Receivers

Noise specifications for junction field-effect transistors are presented in different ways depending on the particular semiconductor manufacturer. Arithmetic involved in converting these specifications to equivalent RMS noise in microvolts developed at the preamplifier input terminal is reviewed. These methods were useful for estimating the noise performance of high input impedance preamplifiers used with E-field antennas operating in the range of 1 KHz to 10 MHz. Both the JFET MPF-102 transistor and the COS/MOS CA3600 transistor array provided amplification for VLF receivers where the internally generated noise was well below the atmospheric noise level. The CA3600 transistor array provided better performance because of the more symmetrical complementary MOS transistor transfer characteristics than a single N-type biased JFET transistor. The CMOS amplifier resulted in self-compensating gain characteristics over a very wide temperature range from -55 to +125 C.

Burhans, R. W.

A study of low-noise preamplifier systems for use with room temperature mercuric iodide /HgI2/ X-ray detectors

An analysis of different preamplification systems for use with room temperature mercuric iodide X-ray detectors has been performed. Resistor-, drain-, and light-feedback preamplifiers have been studied. Energy resolution values of 295 eV (FWHM) for an Fe-55 source (5.9 keV) and 225 eV (FWHM) for a pulser have been obtained with both the detector and the input FET at room temperature using a pulsed-light feedback preamplifier. Improvement in energy resolution by cooling the input FET using a small Peltier element has been discussed.

Iwanczyk, J. S.

Miniature electrometer preamplifier effectively compensates for input capacitance

Negative capacitance preamplifier using a dual MOS /Metal Oxide Silicon/ transistor in conjunction with bipolar transistors is used with intracellular microelectrodes in recording bioelectric potentials. Applications would include use as a pickup plate video amplifier in storage tube tests and for pH and ionization chamber measurements.

Burrous, C. N.

Differential input preamplifier

Preamplifier chops and amplifies very low level output of thermopile infrared detectors that will be used to measure thermal energy flux of Jupiter and its departure from a blackbody spectrum. Output signal has negligible phase shift. AC signal is RC-coupled to input stage of other amplifiers.

Callaway, P. W.

MSDS sky reference and preamplifier study

The major goals in re-designing the Multispectral Scanner and Data System (MSDS) sky reference are: (1) to remove the sun-elevation angle and aircraft-attitude angle dependence from the solar-sky illumination measurement, and (2) to obtain data on the optical state of the atmosphere. The present sky reference is dependent on solar elevation and provides essentially no information on important atmospheric parameters. Two sky reference designs were tested. One system is built around a hyperbolic mirror and the reflection approach. A second approach to a sky reference utilizes a fish-eye lens to obtain a 180 deg field of view. A detailed re-design of the present sky reference around the fish-eye approach, even with its limitations, is recommended for the MSDS system. A preamplifier study was undertaken to find ways of improving the noise-equivalent reflectance by reducing the noise level for silicon detector channels on the MSDS.

Larsen, L.

Thick-film preamplifier

Preamplifier with hybrid discrete components and integrated-circuit packaging is designed specifically for use as television image-tube output signal conditioner. Circuit is fabricated on alumina substrate, measuring 0.5 by 0.5 by 0.015 inch using gold-base conductor with conductive gold crossovers and dielectric insulation.

Bailey, G. C.

Improvements for Omega RF preamplifiers

An improved Omega navigation system preamplifier, which provides both ADF and Omega outputs from a single antenna input, is described. This preamp has tuneable bandpass filtering, zero phase shift at both output ports, adjustable gain at the Omega output, and it receives power via the coaxial cable to the receiver front-end.

Wright, L.

Liquid helium-cooled MOSFET preamplifier for use with astronomical bolometer

A liquid helium-cooled p-channel enhancement mode MOSFET, the 3N167, is found to have sufficiently low noise for use as a preamplifier with helium-cooled bolometers that are used in infrared astronomy. Its characteristics at 300, 77, and 4.2 K are presented. It is also shown to have useful application with certain photoconductive and photovoltaic infrared detectors.

Goebel, J. H.

Fast scintillation counter preamplifier for the observation of Linsley effect

A fast preamplifier circuit has been designed and thoroughly tested for the purpose of observing the air shower arrival directions including the Linsley effect. The circuit intends to eliminate the time jitter due to variation of scintillation counter signal amplitudes. It assumes that the output signals from one counter system have the same rise time. On this basis, error arising from time jitter is removed by voltage discrimination at about half signal amplitudes. Detailed description of the circuit is reported.

Ng, L. K.

Photodiode Preamplifier for Laser Ranging With Weak Signals

An improved preamplifier circuit has been designed for processing the output of an avalanche photodiode (APD) that is used in a high-resolution laser ranging system to detect laser pulses returning from a target. The improved circuit stands in contrast to prior such circuits in which the APD output current pulses are made to pass, variously, through wide-band or narrow-band load networks before preamplification. A major disadvantage of the prior wide-band load networks is that they are highly susceptible to noise, which degrades timing resolution. A major disadvantage of the prior narrow-band load networks is that they make it difficult to sample the amplitudes of the narrow laser pulses ordinarily used in ranging. In the improved circuit, a load resistor is connected to the APD output and its value is chosen so that the time constant defined by this resistance and the APD capacitance is large, relative to the duration of a laser pulse. The APD capacitance becomes initially charged by the pulse of current generated by a return laser pulse, so that the rise time of the load-network output is comparable to the duration of the return pulse. Thus, the load-network output is characterized by a fast-rising leading edge, which is necessary for accurate pulse timing. On the other hand, the resistance-capacitance combination constitutes a lowpass filter, which helps to suppress noise. The long time constant causes the load network output pulse to have a long shallow-sloping trailing edge, which makes it easy to sample the amplitude of the return pulse. The output of the load network is fed to a low-noise, wide-band amplifier. The amplifier must be a wide-band one in order to preserve the sharp pulse rise for timing. The suppression of noise and the use of a low-noise amplifier enable the ranging system to detect relatively weak return pulses.

Abramovici, Alexander