Search NASA⌕ Search

SEARCH · Search NASA

Results for “PREAMPLIFIERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of Two Guralp Preamplifiers for GS13 Seismometer Application.

Sandia National Laboratories has tested and evaluated a new preamplifier, the Guralp Preamplifier for GS13, manufactured by Guralp. These preamplifiers are used to interface between Guralp digitizers and Geotech GS13 Seismometers. The purpose of the preamplifier evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Guralp GS13 Preamplifiers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry

The nature of the ion signal from a 12-T Fourier-transform ion cyclotron resonance mass spectrometer and the electronic noise were studied to further understand the electronic detection limit. At minimal cost, a new transimpedance preamplifier was designed, computer simulated, built, and tested. The preamplifier design pushes the electronic signal-to-noise performance at room temperature to the limit, because of its enhanced tolerance of the capacitance of the detection device, lower intrinsic noise, and larger flat mid-band gain (input current noise spectral density of around 1 pA/{radical}(Hz) when the transimpedance is about 85 dB{Omega}). The designed preamplifier has a bandwidth of {approx}3 kHz to 10 MHz, which corresponds to the mass-to-charge ratio, m/z, of approximately 18 to 61 k at 12 T. The transimpedance and the bandwidth can be easily adjusted by changing the value of passive components. The feedback limitation of the circuit is discussed. With the maximum possible transimpedance of 5.3 M{Omega} when using an 0402 surface mount resistor, the preamplifier was estimated to be able to detect {approx}110 charges in a single scan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Two Guralp Preamplifiers for GS21 Seismometer Application

Sandia National Laboratories has tested and evaluated two Guralp preamplifiers for use with a GS21 seismometer application. The two preamplifiers have a gain factor of 61.39. The purpose of the preamplifier evaluation was to determine a measured gain factor, transfer function, total harmonic distortion, self-noise, application passband, dynamic range, seismometer calibration pass-through, and to comment on any issues encountered during the evaluation. The test results included in this report were in response to static, tonal, and dynamic input signals. The Guralp GS21 preamplifiers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO). Test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Note: A timing micro-channel plate detector with backside fast preamplifier

A timing micro-channel plate detector with a backside double-channel fast preamplifier was developed to avoid distortion during signal propagation from the anode to the preamplifier. The mechanical and electronic structure is described. The detector including its backside preamplifier is tested by a {sup 241}Am α-source and a rise time of ∼2 ns with an output background noise of 4 mV{sub rms} was achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of responsivity and noise in a direct-coupled photodetector-preamplifier for facsimile cameras

The direct-coupled (DC) mode of detector operation is evaluated for use in a facsimile camera. Photodiode-preamplifier sensitivity is described in terms of photodiode responsivity and possible noise sources resulting from the photodiode and preamplifier. Responsivity and noise limitations are experimentally verified and used to predict photodiode-preamplifier sensitivity under a wide range of operating conditions. Results demonstrate that the DC mode offers advantages in sensitivity and reduced mechanical complexity for facsimile cameras over the more common technique of chopping the radiation and ac amplifying the resultant signal.

Kelly, W. L., IV↗

Task three: Report: STDN Antenna and preamplifier cost tradeoff study

The general goal of this task, STDN Antenna and Preamplifier G/T Study, was to determine cost-effective combinations of antennas and preamplifiers for several sets of conditions for frequency, antenna elevation angle, and rain. The output of the study includes design curves and tables which indicate the best choice of antenna size and preamplifier type to provide a given G/T performance. The report indicates how to evaluate the cost effectiveness of proposed improvements to a given station. Certain parametric variations are presented to emphasize the improvement available by reducing RF losses and improving the antenna feed.

Source record↗

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

A Discrete Component Low-Noise Preamplifier Readout for a Linear (1x16) SiC Photodiode Array

A compact, low-noise and inexpensive preamplifier circuit has been designed and fabricated to optimally readout a common cathode (1x16) channel 4H-SiC Schottky photodiode array for use in ultraviolet experiments. The readout uses an operational amplifier with 10 pF capacitor in the feedback loop in parallel with a low leakage switch for each of the channels. This circuit configuration allows for reiterative sample, integrate and reset. A sampling technique is given to remove Johnson noise, enabling a femtoampere level readout noise performance. Commercial-off-the-shelf acquisition electronics are used to digitize the preamplifier analogue signals. The data logging acquisition electronics has a different integration circuit, which allows the bandwidth and gain to be independently adjusted. Using this readout, photoresponse measurements across the array between spectral wavelengths 200 nm and 370 nm are made to establish the array pixels external quantum efficiency, current responsivity and noise equivalent power.

low-noise preamplifier↗

Common antenna preamplifier-isolator for VLF-LF receivers

A modified high impedance preamplifier circuit which provides outputs to drive an Omega-VLF receiver and an ADF-LF receiver from a common antenna on general aviation aircraft is reported. The preamplifier was evaluated with fixed ground station receivers and results show the burn out problem of the first stage MOSFET during very close lightning discharges was eliminated.

Burhans, R. W.↗

Preamplifier Noise in VLF Receivers

Noise specifications for junction field-effect transistors are presented in different ways depending on the particular semiconductor manufacturer. Arithmetic involved in converting these specifications to equivalent RMS noise in microvolts developed at the preamplifier input terminal is reviewed. These methods were useful for estimating the noise performance of high input impedance preamplifiers used with E-field antennas operating in the range of 1 KHz to 10 MHz. Both the JFET MPF-102 transistor and the COS/MOS CA3600 transistor array provided amplification for VLF receivers where the internally generated noise was well below the atmospheric noise level. The CA3600 transistor array provided better performance because of the more symmetrical complementary MOS transistor transfer characteristics than a single N-type biased JFET transistor. The CMOS amplifier resulted in self-compensating gain characteristics over a very wide temperature range from -55 to +125 C.

Burhans, R. W.↗

A study of low-noise preamplifier systems for use with room temperature mercuric iodide /HgI2/ X-ray detectors

An analysis of different preamplification systems for use with room temperature mercuric iodide X-ray detectors has been performed. Resistor-, drain-, and light-feedback preamplifiers have been studied. Energy resolution values of 295 eV (FWHM) for an Fe-55 source (5.9 keV) and 225 eV (FWHM) for a pulser have been obtained with both the detector and the input FET at room temperature using a pulsed-light feedback preamplifier. Improvement in energy resolution by cooling the input FET using a small Peltier element has been discussed.

Iwanczyk, J. S.↗

High speed preamplifier circuit, detection electronics, and radiation detection systems therefrom

A preamplifier circuit for processing a signal provided by a radiation detector includes a transimpedance amplifier coupled to receive a current signal from a detector and generate a voltage signal at its output. A second amplification stage has an input coupled to an output of the transimpedance amplifier for providing an amplified voltage signal. Detector electronics include a preamplifier circuit having a first and second transimpedance amplifier coupled to receive a current signal from a first and second location on a detector, respectively, and generate a first and second voltage signal at respective outputs. A second amplification stage has an input coupled to an output of the transimpedance amplifiers for amplifying the first and said second voltage signals to provide first and second amplified voltage signals. A differential output stage is coupled to the second amplification stage for receiving the first and second amplified voltage signals and providing a pair of outputs from each of the first and second amplified voltage signals. Read out circuitry has an input coupled to receive both of the pair of outputs, the read out circuitry having structure for processing each of the pair of outputs, and providing a single digital output having a time-stamp therefrom.

Riedel, Richard A↗

Characterization of a New Charge Sensitive Preamplifier (CSP) for the Electromagnetic Calorimeters of the ALICE Experiment

The ALICE calorimeters PHOS and EMCal (including its extension DCal) are based on Avalanche Photo-Diode (APD) photosensors with Charge Sensitive Preamplifiers (CSPs) for readout of the scintillating elements. A new CSP has been developed on the basis of the design of the PHOS CSP, but modified to meet the requirements of the EMCal and DCal. Modifications were made specifically for a different APD choice with different characteristics, and also with the goals of less noise, faster rise time, and reduced cost. This paper presents a detailed description of the new CSP features and the test results.

99 GENERAL AND MISCELLANEOUS↗

Investigating the non-ideal behavior of the Amptek A111 charge sensitive preamplifier & discriminator board— 3 He proportional counter combination used in common safeguards neutron coincidence counters

Neutron coincidence counting is a well-established technique used for the nondestructive quantification of specialnuclear material during international safeguards inspections. The neutron counters are commonly designedwith an annular body, centered about an inner well or cavity into which a measurement item is placed,and the moderating annulus is populated with 3 He tubes connected to a varying number of preamplifiers.The Canberra Industries JAB-01 preamplifier/amplifier/discriminator board is employed within the company’sneutron coincidence counters, built for use by the International Atomic Energy Agency. Non-ideal behavior ofthese boards was identified during a detector characterization, using list mode data acquisition, of a CanberraIndustries JCC-71 Neutron Coincidence Collar implementing four JAB-01 boards. List mode data acquisition andanalysis reveals features that have commonly been overlooked by historic timing gate selection while using shiftregister data acquisition methods, which are routinely adopted in international safeguards. It has been shownthat double pulsing effects are not fully captured within the predelay setting; therefore, they may influencethe response of the system within the standard operating regime. We set out to identify and correct for doublepulsing in our post analysis of neutron pulse trains, while isolating this behavior to the relevant system. Tounderstand and potentially address these concerns, the responses of two different JAB-01 board systems – theJCC-71 Neutron Coincidence Collar and a modified JCC-51 Active Well Neutron Coincidence Counter – arecompared with the responses of an AnTech Inc. N2071 Neutron Coincidence Collar that also uses an amplifierbuilt on the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip, and a JCC-71 that employs custompreamplifiers designed at Oak Ridge National Laboratory

42 ENGINEERING↗