Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESSURE BREATHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The US Navy/Canadian DCIEM research initiative on pressure breathing physiology

Development of improved positive pressure breathing garments for altitude and acceleration protection has occurred without collection of sufficient physiological data to understand the mechanisms of the improvement. Furthermore, modeling of the predicted response of future enhanced garments is greatly hampered by this lack of information. A joint, international effort is under way between Canada's Defense and Civil Institute for Environmental Medicine (DCIEM) and the US Navy's Naval Air Warfare Center Aircraft Division, Warminster (NAWCACDIVWAR). Using a Canadian subject pool, experiments at both the DCIEM altitude facility and the NAWCADIVWAR Dynamic Flight Simulator have been conducted to determine the cardiovascular and respiratory consequences of high levels of positive pressure breathing for altitude and positive pressure breathing for acceleration protection. Various improved pressure breathing garments were used to collect comparative physiological and performance data. New pressure breathing level and durahon capabilities have been encountered. Further studies will address further improvements in pressure suit design and correlation of altitude and acceleration data.

Whitley, Phillip E.↗

Renal effects of continuous negative pressure breathing

Continuous negative pressure breathing (CNPB) was utilized to simulate the thoracic vascular distension of zero g or space, in 11 anesthetized rats. The animals underwent renal clearance and micropuncture renal nephron studies before, during, and after CNPB. Rats were pretreated with a high salt diet and I-M desoxycorticosterone (DOCA) in excess. None of these rats diuresed with CNPB. In contrast 5 of the 7 remaining rats increased the fraction of the filtered sodium excreted (C sub Na/GFR, p .05) and their urinary flow rate (V, p .05). Potassium excretion increased (U sub k V, p .05). End proximal tubular fluid specimen's TF/P inulin ratios were unchanged. Whole kidney and single nephron glomerular filtration rates fell 10%. CNPB, a mechanism for atrial distension, appears to cause, in rats, a decrease in distal tubular sodium, water and potassium reabsorption. Exogenous mineral-corticoid prevents the diuresis, saluresis, and kaluresis.

Kinney, M. J.↗

Renal effects of continuous negative pressure breathing

Continuous negative pressure breathing (CNPB) was utilized to simulate the thoracic vascular distension of zero G in 11 anesthetized rats. The animals underwent renal clearance and micropuncture renal nephron studies before, during, and after CNPB. Four rats were pretreated with a high salt diet and I-M desoxycorticosterone (DOCA) in excess. None of these rats diuresed with CNPB. In contrast, five of the seven remaining rats increased the fraction of the filtered sodium excreted and their urinary flow rate. Potassium excretion increased. End proximal tubular fluid specimen's TF/P inulin ratios were unchanged. Whole kidney and single nephron glomerular filtration rates fell 10%. CNPB, a mechanism for atrial distension, appears to cause in the rat a decrease in distal tubular sodium and water reabsorption. Exogenous mineral-corticoid prevents the diuresis, saluresis, and kaluresis. The adequacy of other nonatrial volume control mechanisms in regulating renal salt and water conservation in opposition to the studied atrial-renal (Henry-Gauer) reflex of thoracic vascular distension is confirmed.

Kinney, M. J.↗

Programmed-pressure air supply for positive-pressure breathing system

Motor-driven cam varies height of mercury column connected to loading diaphragm of pressure-regulating valve. Air supplied to open-loop, positive pressure breathing system is controlled so repetitive pressure--time profiles can be obtained during every insufflation--exhaust cycle.

Troutman, S. J., Jr.↗

Role of atrial receptors in the control of sodium excretion

Responses of an innervated and a contralateral chronically denervated kidney to mild positive pressure breathing are compared for saline volume expansions in chloralose anesthetized dogs. It is shown that mild pressure breathing significantly reduces sodium excretion, urine flow, free water clearance, and PAH clearance. After 20 minutes of positive pressure breathing, both kidney responses are identical suggesting the release of natriuretic hormone which reduces renal function in addition to the demonstrated change in renal nerve activity. Increase of the left atrial pressure through balloon obstruction of the mitral orifice increases urine flow, sodium excretion and PAH clearance; inflation of the balloon and positive pressure breathing again depresses renal function. Preliminary evidence indicates that receptors in the right atrium are more severely affected by pressure breathing than those in the left atrium.

Meehan, J. R.↗

Improved fireman's compressed air breathing system pressure vessel development program

Prototype high pressure glass filament-wound, aluminum-lined pressurant vessels suitable for use in a fireman's compressed air breathing system were designed, fabricated, and acceptance tested in order to demonstrate the feasibility of producing such high performance, lightweight units. The 4000 psi tanks have a 60 standard cubic foot (SCF) air capacity, and have a 6.5 inch diamter, 19 inch length, 415 inch volume, weigh 13 pounds when empty, and contain 33 percent more air than the current 45 SCF (2250 psi) steel units. The current steel 60 SCF (3000 psi) tanks weigh approximately twice as much as the prototype when empty, and are 2 inches, or 10 percent shorter. The prototype units also have non-rusting aluminum interiors, which removes the hazard of corrosion, the need for internal coatings, and the possibility of rust particles clogging the breathing system.

King, H. A.↗

Firefighter's compressed air breathing system pressure vessel development program

The research to design, fabricate, test, and deliver a pressure vessel for the main component in an improved high-performance firefighter's breathing system is reported. The principal physical and performance characteristics of the vessel which were required are: (1) maximum weight of 9.0 lb; (2) maximum operating pressure of 4500 psig (charge pressure of 4000 psig); (3) minimum contained volume of 280 in. 3; (4) proof pressure of 6750 psig; (5) minimum burst pressure of 9000 psig following operational and service life; and (6) a minimum service life of 15 years. The vessel developed to fulfill the requirements described was completely sucessful, i.e., every category of performence was satisfied. The average weight of the vessel was found to be about 8.3 lb, well below the 9.0 lb specification requirement.

Beck, E. J.↗

Heart-Lung Interactions in Aerospace Medicine

Few of the heart-lung interactions that are discussed have been studied in any detail in the aerospace environment, but is seems that many such interactions must occur in the setting of altered accelerative loadings and pressure breathing. That few investigations are in progress suggests that clinical and academic laboratory investigators and aerospace organizations are further apart than during the pioneering work on pressure breathing and acceleration tolerance in the 1940s. The purpose is to reintroduce some of the perennial problems of aviation physiology as well as some newer aerospace concerns that may be of interest. Many possible heart-lung interactions are pondered, by necessity often drawing on data from within the aviation field, collected before the modern understanding of these interactions developed, or on recent laboratory data that may not be strictly applicable. In the field of zero-gravity effects, speculation inevitably outruns the sparse available data.

Guy, Harold J. B.↗

Compression under a mechanical counter pressure space suit glove

Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, p<0.001). There was no significant change in glove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

NASA Discipline Life Sciences Technologies↗

Hypobaric decompression prebreathe requirements and breathing environment

To reduce incidence of decompression sickness (DCS), prebreathing 100 percent oxygen to denitrogenate is required prior to hypobaric decompressions from a sea level pressure breathing environment to pressures lower than 350 mm Hg (20,000 ft; 6.8 psia). The tissue ratio (TR) of such exposures equals or exceeds 1.7; TR being the tissue nitrogen pressure prior to decompression divided by the total pressure after decompression (((0.781)(14.697))/6.758). Designing pressure suits capable of greater pressure differentials, lower TR's, and procedures which limit the potential for DCS occurrence would enhance operational efficiency. The current 10.2 psia stage decompression prior to extravehicular activity (EVA) from the Shuttle in the 100 percent oxygen, 4.3 psia suit, results in a TR of 1.65 and has proven to be relatively free of DCS. Our recent study of zero-prebreathe decompressions to 6.8 psia breathing 100 percent oxygen (TR = 1.66) also resulted in no DCS (N = 10). The level of severe, Spencer Grades 3 or 4, venous gas emboli (VGE) increased from 0 percent at 9.5 psia to 40 percent at 6.8 psia yielding a Probit curve of VGE risk for the 51 male subjects who participated in these recent studies. Earlier, analogous decompressions using a 50 percent oxygen, 50 percent nitrogen breathing mixture resulted in one case of DCS and significantly higher levels of severe VGE, e.g., at 7.8 psia, the mixed gas breathing environment resulted in a 56 percent incidence of severe VGE versus 10 percent with use of 100 percent oxygen. The report of this study recommended use of 100 percent oxygen during zero-prebreathe exposure to 6.8 psia if such a suit could be developed. For future, long-term missions, we suggest study of the effects of decompression over several days to a breathing environment of 150 mmHg O2 and approximately 52 mmHg He as a means of eliminating DCS and VGE hazards during subsequent excursions. Once physiologically adapted to a 4 psia vehicle, base, or space station segment, crew members could use greatly simplified EVA suits with greater mobility and no prebreathe requirement.

Webb, James T.↗

Programmable Cadence Timer

Electronic metronome paces users through wide range of exercise routines. Conceptual programmable cadence timer provides rhythmic aural and visual cues. Timer automatically changes cadence according to program entered by the user. It also functions as clock, stopwatch, or alarm. Modular pacer operated as single unit or as two units. With audiovisual module moved away from base module, user concentrates on exercise cues without distraction from information appearing on the liquid-crystal display. Variety of uses in rehabilitative medicine, experimental medicine, sports, and gymnastics. Used in intermittent positive-pressure breathing treatment, in which patient must rhythmically inhale and retain medication delivered under positive pressure; and in incentive spirometer treatment, in which patient must inhale maximally at regular intervals.

Hall, William A.↗

Flammability, Odor, Offgassing, and Compatibility Requirements and Test Procedures for Materials in Environments that Support Combustion

This handbook establishes NASA program requirements for evaluation, testing, and selection of materials to preclude unsafe conditions related to flammability, odor, offgassing, and fluid compatibility. Materials intended for use in space vehicles, specified test facilities, and specified ground support equipment (GSE) must meet the requirements of this document. Additional materials performance requirements may be specified in other program or NASA center specific documentation. Responsible NASA centers materials organizations must include applicable requirements of this document in their materials control programs. Materials used in habitable areas of spacecraft, including the materials of the spacecraft, stowed equipment, and experiments, must be evaluated for flammability, odor, and offgassing characteristics. All materials used in other areas must be evaluated for flammability characteristics. In addition, materials that are exposed to liquid oxygen (LOX), gaseous oxygen (GOX), and other reactive fluids' must be evaluated for compatibility with the fluid in their use application. Materials exposed to pressurized breathing gases also must be evaluated for odor and offgassing characteristics. The worst-case anticipated use environment (most hazardous pressure, temperature, material thickness, and fluid exposure conditions) must be used in the evaluation process. Materials that have been shown to meet the criteria of the required tests are acceptable for further consideration in design. Whenever possible, materials should be selected that have already been shown to meet the test criteria in the use environment. Existing test data are compiled in the NASA Marshall Space Flight Center (MSFC) Materials and Processes Technical Information System (MAPTIS) and published periodically as the latest revision of a joint document with Johnson Space Center (JSC), MSFC-HDBK-527/JSC 09604. MAPTIS can be accessed by computer datalink. Systems containing materials that have not been tested or do not meet the criteria of the required tests must be verified to be acceptable in the use configuration by analysis or testing. This verification rationale must be documented and submitted to the responsible NASA center materials organization for approval.

Source record↗

Understanding Pilot Breathing – A Case Study in Systems Engineering

This position paper assesses the Pilot Breathing Assessment’s driving requirement to collect missing data on pilot breathing pressure, flow, rate, oxygen and CO2, simultaneously with aircraft data. Repeat measures data were collected over a 2-year period from 5 NASA test-pilots flying 8 flight profiles on NASA F-15 and F/A-18 (A, B) aircraft. This Pilot Breathing Assessment Systems Engineering (PiBASE) position paper serves as a case-study of systems engineering that accommodates the human as a distinct part of the whole. It acknowledges that a successful machine design intended for human use must include human systems biology/physiology as an integral part of planning, design, and implementation.

Pilot Breathing Assessment Systems Engineering↗