Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESSURIZED CABIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Facilitated transport membrane with functionalized ionic liquid carriers for CO 2 /N 2 , CO 2 /O 2 , and CO 2 /air separations

CO 2 separations from cabin air and the atmospheric air are challenged by the very low partial pressures of CO 2 . In this study, a facilitated transport membrane (FTM) is developed to separate CO 2 from air using functionalized ionic liquid (IL) and poly(ionic liquid) (PIL) carriers. A highly permeable bicontinuous structured poly(ethersulfone)/poly(ethylene terephthalate) ( b PES/PET) substrate is used to support the PIL–IL impregnated graphene oxide thin film. The CO 2 separation performance was tested under a mixture feed of CO 2 /N 2 /O 2 /H 2 O. Under 410 ppm of CO 2 at 1 atm feed gas, CO 2 permanence of 3923 GPU, and CO 2 /N 2 and CO 2 /O 2 selectivities of 1200 and 300, respectively, are achieved with helium sweeping on the permeate side. For increased transmembrane pressure (>0 atm), a thicker PIL–IL/GO layer was shown to provide mechanical strength and prevent leaching of the mobile carrier. CO 2 binding to the carriers, ion diffusivities, and the glass transition temperature of the PIL–IL gels were examined to determine the membrane composition and rationalize the superior separation performance obtained. This report represents the first FTM study with PIL–IL carriers for CO 2 separation from air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Passenger cabin air distribution system and method of using

A passenger cabin air distribution system includes a ventilation system and an ejector-diffuser. The ventilation system is operable to provide a conditioned air. The ejector-diffuser is positioned to receive a flow of the conditioned air from the ventilation system. The ejector-diffuser includes an induction unit and a diffuser section. The induction unit includes a secondary inlet in communication with a cabin air from a passenger cabin and is configured to mix the flow of the conditioned air with an induced flow of the cabin air into a mixed air. The diffuser section includes a discharge to eject the mixed air to the passenger cabin. The diffuser section is shaped to provide for efficient mixing with low backpressure in order to maintain the low motive pressure in the nozzle.

42 ENGINEERING↗

Sorbent system for removing ammonia and organic compounds from a gaseous environment

A first process and sorbent for removing ammonia from a gaseous environment, the sorbent comprised of graphene oxide having supported thereon at least one compound selected from metal salts, metal oxides and acids, each of which is capable of adsorbing ammonia. A second process and sorbent system for removing ammonia and a volatile organic compound from a gaseous environment; the sorbent system comprised of two graphene-based materials: (a) the aforementioned graphene oxide, and (b) a nitrogen and oxygen-functionalized graphene. The sorbents are regenerable under a pressure gradient with little or no application of heat. The processes are operable through multiple adsorption-desorption cycles and are applicable to purifying and revitalizing air contaminated with ammonia and organic compounds as may be found in spacesuits, aerospace cabins, underwater vehicles, and other confined-entry environments.

Junaedi, Christian↗

Counterflow Virtual Impactor (CVI) Inlet Aboard Aircraft (INLETCVI-AIR) Instrument Handbook

The counterflow virtual impactor (CVI) inlet separates out and samples cloud elements via inertial impaction. Warm, dry, particle-free carrier gas of known composition is pumped to the tip of the inlet in the direction opposite of the flow of air. The flow lines of the incoming free stream air are split. Larger droplets and ice crystals suspended in the sample air have enough inertia to penetrate the counterflow and enter the sample flow, while smaller, unactivated particles follow the streamlines of the air flowing around the inlet’s tip (Noone et al. 1988). The instrument is capable of sampling cloud elements as a function of cut size by changing the velocity of counterflow at the probe tip. The CVI cut size is usually defined as a diameter of a smallest particle for which penetration rate is 50%. For the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facilityGulfstream-159 aircraft’s CVI inlet, that value is usually around 13 microns. The dry heated air, normally used as the carrier gas, also serves to evaporate water from the hydrometeor, leaving the residuals to be sampled by in-cabin aerosol instrumentation. The number concentration of the droplet residue in the CVI sample line is usually increased with respect to corresponding cloud element number concentration. The CVI performance as a concentrator is usually described via CVI enhancement factor, which is a conversion factor between ambient volumetric concentration (not adjusted to standard temperature and pressure) and volumetric concentration in the CVI sample line.

54 ENVIRONMENTAL SCIENCES↗