Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESTRESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cell prestress. I. Stiffness and prestress are closely associated in adherent contractile cells

The tensegrity hypothesis holds that the cytoskeleton is a structure whose shape is stabilized predominantly by the tensile stresses borne by filamentous structures. Accordingly, cell stiffness must increase in proportion with the level of the tensile stress, which is called the prestress. Here we have tested that prediction in adherent human airway smooth muscle (HASM) cells. Traction microscopy was used to measure the distribution of contractile stresses arising at the interface between each cell and its substrate; this distribution is called the traction field. Because the traction field must be balanced by tensile stresses within the cell body, the prestress could be computed. Cell stiffness (G) was measured by oscillatory magnetic twisting cytometry. As the contractile state of the cell was modulated with graded concentrations of relaxing or contracting agonists (isoproterenol or histamine, respectively), the mean prestress ((t)) ranged from 350 to 1,900 Pa. Over that range, cell stiffness increased linearly with the prestress: G (Pa) = 0.18(t) + 92. While this association does not necessarily preclude other interpretations, it is the hallmark of systems that secure shape stability mainly through the prestress. Regardless of mechanism, these data establish a strong association between stiffness of HASM cells and the level of tensile stress within the cytoskeleton.

NASA Discipline Cell Biology↗

Control of Prestressing Force in Rod for Reducing Bending in Beams

This paper presents a method to determine the prestressing force required in a rod for reducing the bending effects in a beam. The rod is positioned underneath the beam such that the prestressing force is counteracting the effects of beam bending. It has been found that the prestressing force may also increase the bending as a result of P-delta effect. Therefore, the choice of both the prestressing force and the rod eccentricity from the beam axis is important in determining the appropriate actions to resist the bending of the beam. Over-prestressing the rod may even induce bending or buckling failure in the beam in the reverse direction.

36 MATERIALS SCIENCE↗

Design study of prestressed rotor spar concept

Studies on the Bell Helicopter 540 Rotor System of the AH-1G helicopter were performed. The stiffness, mass and geometric configurations of the Bell blade were matched to give a dynamically similar prestressed composite blade. A multi-tube, prestressed composite spar blade configuration was designed for superior ballistic survivability at low life cycle cost. The composite spar prestresses, imparted during fabrication, are chosen to maintain compression in the high strength cryogenically stretchformed 304-L stainless steel liner and tension in the overwrapped HTS graphite fibers under operating loads. This prestressing results in greatly improved crack propagation and fatigue resistance as well as enhanced fiber stiffness properties. Advantages projected for the prestressed composite rotor spar concept include increased operational life and improved ballistic survivability at low life cycle cost.

Gleich, D.↗

Comparative Analysis of Hotspot Stress Endurance in Pristine and Thermal Cycled Prestressed Glass–Glass Photovoltaic Modules

Hotspots pose a significant long-term reliability challenge in photovoltaic (PV) modules that can have a detrimental impact on the efficiency, safety, and financial viability of a PV system. This paper aims to evaluate the endurance of hotspot stress in pristine and prestressed glass–glass (GG) modules. The accelerated prestressing was conducted for 600 thermal cycles (TC600) to represent decades of field exposure. GG modules are quickly becoming an alternative to the traditional glass–backsheet (GB) modules that have been the industry standard. Unlike other conventional studies that subject only pristine modules to hotspot stress, this paper evaluates the performance of an accelerated/simulated field-aged GG module (using TC600) and a pristine GG module. Pre- and post-characterizations were performed before and after each test to determine changes in electrical performance and observe any defects in GG modules. During the hotspot test, an approximately 200 °C maximum cell temperature was observed with a cell shading of 25% (the worst-case shading ratio). After the hotspot test, electroluminescence imaging indicated that most cells in the prestressed GG module exhibited severe damage whereas no significant defects were evident in the pristine GG module where the prestressed GG module degraded 8.2% and the pristine GG module degraded 1.5% in maximum power. These findings are critical for the industry, considering that GG bifacial modules will dominate the market.

14 SOLAR ENERGY↗

Fabrication and testing of prestressed composite rotor blade spar specimens

Prestressed composite spar specimens were fabricated and evaluated by crack propagation and ballistic penetration tests. The crack propagation tests on flawed specimens showed that the prestressed composite spar construction significantly suppresses crack growth. Damage from three high velocity 30 caliber projectile hits was confined to three small holes in the ballistic test specimen. No fragmentation or crack propagation was observed indicating good ballistic damage resistance. Rotor attachment approaches and improved structural performance configurations were identified. Design theory was verified by tests. The prestressed composite spar configuration consisted of a compressively prestressed high strength ARDEFORM 301 stainless steel liner overwrapped with pretensioned S-994 fiberglass.

Gleich, D.↗

Actuator placement in prestressed adaptive trusses for vibration control

This paper describes the optimal location selection of actuators for vibration control in prestressed adaptive trusses. Since prestressed adaptive trusses are statically indeterminate, the actuators to be used for vibration control purposes must work against (1) existing static axial prestressing forces, (2) static axial forces caused by the actuation, and (3) dynamic axial forces caused by the motion of the mass. In statically determinate adaptive trusses (1) and (2) are non - existing. The actuator placement problem in statically indeterminate trusses is therefore governed by the actuation energy and the actuator strength requirements. Assuming output feedback type control of selected vibration modes in autonomous systems, a procedure is given for the placement of vibration controlling actuators in prestressed adaptive trusses.

Jalihal, P.↗

Effect of residual stresses induced by prestressing on rolling element fatigue life

A mechanical prestress cycle suitable to induce compressive stress beneath the surface of the inner race of radially loaded 207-size bearings was determined. Compressive residual stress in excess 0.69 x 10 to the 9th power N/sq m (100,000 psi), as measured by X-ray diffraction, were induced at the depth of maximum shearing stress. The prestress cycle consisted of running the bearings for 25 hours at 2750 rpm at a radial load which produced a maximum Hertz stress of 3.3 x 10 to the 9th power N/sq m (480,000 psi) at the contact of the inner race and the heaviest loaded ball. Bearings subjected to this prestress cycle and subsequently fatigue tested gave a 10 percent fatigue life greater than twice that of a group of baseline bearings.

Parker, R. J.↗

Geometry control in prestressed adaptive space trusses

In this work the actuator placement problem for the precision control in prestressed adaptive space trusses is studied. These structures cannot be statically determinate, implying that the length-adjusting actuators have to work against the existing prestressing forces, and also against the stresses caused by the actuation. This type of difficulties does not exist in statically determinate adaptive trusses where, except for overcoming the friction, the actuators operate under zero axial force, and require almost no energy. The actuator placement problem in statically inderterminate trusses is, therefore, governed seriously by the energy and the strength requirements. The paper provides various methodologies for the actuator placement problem in prestressed space trusses.

Sener, Murat↗

The Role of Azimuthal Prestress in the Longitudinal Degradation of Nb 3 Sn Superconducting Magnets

Superconducting magnet coils are subject to enormous electro-magnetic forces which push the cables away from the winding pole, and against the surrounding structure. This structure is usually optimized trying to limit the overall motion and the strains experienced by the superconducting elements. To achieve this, preload forces are applied both in the coil cross-section and along its length. If the e.m. forces overcome these preloads, separation between the coil and the pole occurs, resulting in an overall loss of rigidity. During the magnet design process, it is often tempting to treat the optimization of the azimuthal and longitudinal preload systems separately. However, the two are inextricably related: as the cross-section preload increases, friction can prevent any motion in the longitudinal plane, and decreasing it can instead allow dangerous motions in the conductor ends. The latter can result in very high strains and, in Nb 3 Sn conductors, damage that can prevent the magnet to reach the desired performances. In an attempt to define design guidelines, in this paper we use simplified numerical models to compute, as a function of the in-plane prestress, the variation of the peak strains in the end region of the coils. Finally, we investigate the impact of the azimuthal prestress on a real magnet case, the High-Luminosity Nb 3 Sn Quadrupole MQXF.

Nb3Sn↗

Review of Failure Modes Applicable to Prestressed Concrete Containments

Prestressed concrete containment structures are subject to performance loss primarily due to aging and degradation. Many nuclear power plants (NPPs) have extended operating licenses beyond the design life of 40 years and some are considering operation for up to 80 years. The focus of this review is to determine which modes of performance loss, or 'failure modes', are most applicable to prestressed concrete containment vessels (PCCVs) beyond the age of 40 years. A list of failure modes taken from Crystal River Nuclear Plant Special Inspection Report is analyzed for applicability to aging nuclear containment structures. Each failure mode is described and discussed in detail. A table is provided to highlight the severity of each failure mode. This page left blank

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanically prestressed windows

A method was developed for mechanically prestressing glass used in spacecraft windows so that surface imperfections of the glass will not propagate under stress. A metal ring, in tension, is placed around the periphery of the glass where the interference fit between the ring and glass fixes the glass in a state of uniform compression. When the glass is subjected to a pressure loading, the compressive prestress prevents tension loading of the outer surface and, therefore, eliminates the tendency for propagation of surface imperfections.

Keathley, W. H.↗

Effect of deoxygenation and prestressing on hydrocarbon fuel thermal stability

A jet fuel thermal oxidation tester was used to study the effect of deoxygenation and deoxygenated prestressing on deposit formation when hydrocarbon fuels are thermally stressed. Four pure hydrocarbons (n-decane, cyclohexane, benzene and 1-hexene) and two mixtures (10 percent tetralin in n-dodecane and commercial Jet A) were used at temperatures of 250 C to 400 C. Deoxygenation decreased deposit formation for cycloheaxane but increased it for benzene. Deoxygenation decreased deposit formation for the two fuel mixtures at 250 C but had no effect at 350 C. Deoxygenated prestressing either increased or decreased deposit formation depending on the fuel used and the temperature.

Bittker, D. A.↗

Optimal locations of redundants for prestressing adaptive trusses with buckling considerations

This paper describes the optimal locations selection of redundant bars for prestressing a determinate truss. Two computationally simple algorithms are presented to obtain the optimal locations of the redundants. The paper then describes a procedure to prevent local buckling/rupture of individual bars of the resulting indeterminate truss and its global buckling, by introducing a positive scale parameter for the prestressing forces. The procedure is illustrated on a simple two-dimensional truss.

Jalihal, P.↗

Prestressed Composite Parts

Matrix/fiber structural components strengthened by prestressing, according to proposal, increasing effective tensile strengths of components and enabling components to function in applications in which they otherwise fail. Reinforcing fibers stretched while encapsulated in matrix. After encapsulation, fibers released, placing matrix in lengthwise compression. Variety of fiber/matrix combinations fabricated this way. Prestressed quartz fibers encapsulated in ceramic matrix. Resulting composite used to make blade for gas turbine. Ceramic, normally weak in tension, has high strength and endures high temperature.

Surls, Michael M.↗

Increasing the Strength of Aluminum-alloy Columns by Prestressing

A series of tests was made in which the column strength of 17ST tubing was increased as much as 50 percent by prestressing the tubing to 40,000 pounds per square inch in compression under conditions of support that prevented column failure at this stress. This prestressing achieves it's beneficial effects entirely by improving the compressive properties of the material, principally the proportional limit.

Holt, M↗

Apparatuses for prestressing rod-type specimens in torsion for in-situ passive fracture toughness testing in an extremely high-pressure environment of hydrogen

An in-situ specimen fixture particularly adapted for prestressing rod-type SNTT-type specimens comprising a tube and end cap wherein the specimen is secured at one end to the tube, and at the opposite end to the end cap. The end cap is rotatable relative to the tube, and may be fixedly secured for creating a torsional force prestressing the specimen enclosed within the tube.

47 OTHER INSTRUMENTATION↗