Safety analysis report for self-luminous sources used on Apollo spacecraft
Safety analysis of promethium 147 microspheres in self-luminous disks aboard Apollo spacecraft
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Safety analysis of promethium 147 microspheres in self-luminous disks aboard Apollo spacecraft
The 1992 evaluation of A = 147 (1992De38) was updated using data available prior to Nov. 14, 2008.
Beta-excited X-ray sources of strontium 90 promethium 147 for use in design of portable devices
Low-lying energy states of the {sup 147-153}Pm isotopic chain are studied within the framework of the neutron-proton interacting boson-fermion model (IBFM-2). The spectra of these isotopes show a transition from a particle coupled to a vibrational core to a particle coupled to a deformed one. The calculation reproduces this behavior. In addition, reduced transition probabilities B(E2) and B(M1) and quadrupole and magnetic moments, as well as spectroscopic factors corresponding to stripping and pickup transfer reactions, are calculated. Obtained results compare well with the available experimental data, which reinforces the reliability of the wave functions obtained within the IBFM-2 model.
Battery is very important for the present daily life, especially for portable devices. The longer utilization time the better performance of battery. Betavoltaic battery is a device that converts energy from beta decays of radioactive nuclide into electric current. One of merits of the later battery is the life time that can be more than ten years without recharging. To develop the betavoltaic battery for energy source of portable devices we have performed a preliminary simulation design of betavoltaic battery using Pm-147 and Co-60 a beta emitter radionuclides with n-GaAs substrate. From the results we found that the combination of Pm-147 with n-GaAs substrate results in 9.0% of efficiency and higher output current compared to references.
In this paper, we describe the 147 Pm production yields and level of impurities from several targets that consisted of milligram quantities of highly enriched 146 Nd oxide irradiated at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory for durations ranging from 24 to180 h. A comparison between theoretical and experimental data are also presented, and attempts were made to empirically evaluate the neutron capture cross-sections of 41.3-d 148m Pm and 5.4-d 148g Pm. For a one-cycle irradiation (~24 days), 147 Pm yield reaches a maximum value of 101.8 MBq/mg (2.75 mCi/mg) at 60 days after the end of bombardment. Because of large neutron capture cross-sections of 147 Pm, the yield of 147 Pm does not significantly increase with longer irradiation. Our estimates of the thermal neutron capture cross-section and resonance integral for 146 Nd at 1.48 ± 0.05 b and 2.56 ± 0.25 b, respectively, were consistent with the reported values. The effective neutron capture cross-section of 147 Pm to 148m Pm was 53.3 ± 2.7 b - a factor of 2 lower than the 98.7 ± 6.5 b calculated from reported cross-sections. The measured σ eff to the ground state (5.37-d 148g Pm) was 82.0 ± 4.1 b; ~34 % lower than the value of 139 ± 0 b calculated from reported cross-sections. In this work, we also describe the development of a chemical process based on extraction and ion-exchange chromatography for separation of 147 Pm from milligram quantities of 146 Nd and other impurities. Sequential separation of Pm from the Nd target and from other radioisotopic impurities ( 153 Gd and 154&155 Eu, 192 Ir, and 60 Co) was achieved using a LN extraction resin in HCl media followed by further purification of Pm from 60 Co and 192 Ir using a low cross-linking cation exchange resin. Based on these data, we estimated that two rounds of purification under our experimental conditions can provide a mass separation factor of > 104 between Pm and Nd. Our data indicate that curie quantities of 147 Pm with suitable chemical and radioisotopic purity for applications in beta voltaic batteries can be produced by irradiating gram quantities of highly enriched 146 Nd in the flux trap of HFIR for one cycle.
Lanthanide rare-earth metals are ubiquitous in modern technologies, but we know little about chemistry of the 61st element, promethium (Pm), a lanthanide that is highly radioactive and inaccessible. Despite its importance, Pm has been conspicuously absent from the experimental studies of lanthanides, impeding our full comprehension of the so-called lanthanide contraction phenomenon: a fundamental aspect of the periodic table that is quoted in general chemistry textbooks. Here we demonstrate a stable chelation of the 147 Pm radionuclide (half-life of 2.62 years) in aqueous solution by the newly synthesized organic diglycolamide ligand. The resulting homoleptic Pm III complex is studied using synchrotron X-ray absorption spectroscopy and quantum chemical calculations to establish the coordination structure and a bond distance of promethium. These fundamental insights allow a complete structural investigation of a full set of isostructural lanthanide complexes, ultimately capturing the lanthanide contraction in solution solely on the basis of experimental observations. Our results show accelerated shortening of bonds at the beginning of the lanthanide series, which can be correlated to the separation trends shown by diglycolamides. The characterization of the radioactive Pm III complex in an aqueous environment deepens our understanding of intra-lanthanide behaviour and the chemistry and separation of the f-block elements.
The Savannah River Site (SRS) processes used-nuclear fuel to recover uranium. There are many interesting fission products lost in the raffinate from this separation including 147 Pm. Here, the goal of this work was to recover 147 Pm from SRS waste solutions. A radiochemical separation method typically used for the determination of 147 Pm and 151 Sm was modified to purify significant quantities of 147 Pm from the H Canyon waste solutions. The developed scheme was tested on a small aliquot of waste solution from the processing of used fuel from the High Flux Isotope Reactor at Oak Ridge National Laboratory.
The chromatographic resins DGA and LN have been used sequentially to separate curium, californium, plutonium, and various fission products (FPs) to obtain products with a pure radioisotope or a radioelement with high isotopic purity. This 2-step combination of resins has found applications in the 252 Cf and 238 Pu campaigns performed at Oak Ridge National Laboratory. Experiments have been carried out in glove boxes, shielded caves, and hot cells, demonstrating that these resins are adequate and maintain their performance in highly radiolytic environments. We find that using these resins has led to the recovery of curium highly enriched (>95%) in 248 Cm, the clean separation of 251 Cf for the superheavy element research, and the recovery of 147 Pm from the FP stream obtained during the 238 Pu production campaign while demonstrating that the raffinate post DGA is essentially free of transuranic elements.
In this work, we present a demonstration of a high-aspect ratio, three-dimensionally structured betavoltaic device. High-aspect ratio silicon PIN diodes were used as the semiconductor absorber and 147 PmCl 3 was used as the beta emitter. Three devices were fabricated with 147 Pm activities of 2.4 mCi, 7.4 mCi, and 29.5 mCi. The device with the highest activity produced an initial power output of 200 nW and was monitored over a period of 8 months to observe the current–voltage behavior over time, during which time the output current decreased in accordance with the radioactive half-life of 147 Pm. Small deviations in the output current of a few percent during the long-term measurement were found to be attributable to the humidity in the room where the experiment was done. Furthermore, the output current generated from the devices was 68–77% of the theoretical maximum, indicating significant infiltration of the radioisotope into the ridged structures.