Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROMPT NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Data from Rossi-alpha and pulsed neutron prompt neutron time decay measurements at the Oak Ridge Critical Experiments Facility

This report briefly describes the Rossi-alpha and pulsed neutron prompt neutron time decay measurements performed at the Oak Ridge Critical Experiments Facility. This description includes the measurement equipment, type of data, and how to access the actual data from Records Management Services at Oak Ridge National Laboratory and the Nuclear Criticality Safety Benchmark Program (NCSBEP) of the Idaho National Laboratory. Most of the data were acquired between 1960 and 1975 on weapons-grade enriched uranium metal assemblies. Also included are measurements of the same type performed at Los Alamos National Laboratory by Oak Ridge National Laboratory with the JEZEBEL and FLATTOP criticality assemblies and other plutonium metal parts. The purpose of this report is to allow future mining of the data for publication of additional information that can be used to verify calculational methods and nuclear cross sections. These data can be used to create reactor physics benchmarks for the Nuclear Energy Agency’s International Handbook of Evaluated Reactor Physics Experiments. Present calculational methods can be used to directly calculate the measured data. The prompt neutron decay is more neutron spectrum sensitive than other measured quantities, particularly for interacting fissile metal systems where the flight time of neutrons between interacting sections is a large part of the neutron lifetime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data from Rossi-α and Pulsed Neutron Prompt Neutron Time Decay Measurements at the Oak Ridge Critical Experiments Facility

This report briefly describes the prompt neutron decay measurements by the Rossi-α and pulsed neutron methods performed at the Oak Ridge Critical Experiments Facility. It briefly describes the measurement equipment, the type of data, and how to access the actual data from the Laboratory Records Department at Oak Ridge National Laboratory and the International Nuclear Criticality Safety Benchmark Evaluation Program at Idaho National Laboratory. Most of the data was acquired between 1960 and 1975 with weapons-grade enriched uranium metal assemblies. It also includes measurement of these types performed at Los Alamos National Laboratory by Oak Ridge National Laboratory with the JEZEBEL and FLATTOP criticality assemblies and other plutonium metal parts. The purpose of this report is to support future mining of the data for publication of additional information that can be used to verify calculational methods and nuclear cross sections. Present calculational methods can be used to directly calculate the measured data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of combined delayed neutron and differential die-away prompt neutron signal detection for characterization of spent nuclear fuel assemblies

The Next Generation Safeguards Initiative (NGSI) of the U.S. Department of Energy (DOE) has funded multiple laboratories and universities to develop a means to accurately quantify the Plutonium (Pu) mass in spent nuclear fuel assemblies and ways to also detect potential diversion of fuel pins. Delayed Neutron (DN) counting provides a signature somewhat more sensitive to {sup 235}U than Pu while Differential Die-Away (DDA) is complementary in that it has greater sensitivity to Pu. The two methods can, with care, be combined into a single instrument which also provides passive neutron information. Individually the techniques cannot robustly quantify the Pu content but coupled together the information content in the signatures enables Pu quantification separate to the total fissile content. The challenge of merging DN and DDA, prompt neutron (PN) signal, capabilities in the same design is the focus of this paper. Other possibilities also suggest themselves, such as a direct measurement of the reactivity (multiplication) by either the boost in signal obtained during the active interrogation itself or by the extension of the die-away profile. In an early study, conceptual designs have been modeled using a neutron detector comprising fission chambers or 3He proportional counters and a {approx}14 MeV neutron Deuterium-Tritium (DT) generator as the interrogation source. Modeling was performed using the radiation transport code Monte Carlo N-Particles eXtended (MCNPX). Building on this foundation, the present paper quantifies the capability of a new design using an array of {sup 3}He detectors together with fission chambers to optimize both DN and PN detections and active characterization, respectively. This new design was created in order to minimize fission in {sup 238}U (a nuisance DN emitter), to use a realistic neutron generator, to reduce the cost and to achieve near spatial interrogation and detection of the DN and PN, important for detection of diversion, all within the constraints of a single practical instrument. Both DN and PN detections are active techniques using the signal from the most prominent fissile isotopes of spent nuclear fuel that respond the best to a slow neutron interrogation, {sup 235}U, {sup 239}U and {sup 241}PU. The performance is characterized against a library of 64 assemblies and 40 diversion scenarios at different burnup (BU), cooling-time (CT) and initial enrichment (IE) in fresh water.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant At or Near Delayed Critical

The derivation of a non-invasive prompt neutron decay constant sensitivity coefficient is provided in this work. The computation of the sensitivity coefficient derived in this work does not require modification of Monte Carlo source code and is based on capabilities available in Monte Carlo N-Particle R© Code Version 6.2. The prompt neutron decay constant sensitivity coefficients are calculated for 44-group and 252-group energy structures for specific nuclide-reaction pairs in the Jezebel benchmark experiment. The nuclide-reaction pairs investigated in this work include Pu- 239(n,f), Pu-240(n,f), and Pu-241(n,f). Physical explanations of the sensitivity profiles exhibited by the 252-group energy structure are investigated for the prompt neutron multiplication factor, mean neutron lifetime, and prompt neutron decay constant. The prompt neutron decay constant sensitivity coefficients calculated for the 44-group and 252-group energy structure of Pu-239(n,f) are compared. Lastly, the 44-group energy structure sensitivity coefficients calculated are used for nuclear-data induced uncertainty quantification of the neutron multiplication factor. This work shows that a reduction in the nuclear data-induced uncertainty of the neutron multiplication factor is possible for all nuclide-reaction pairs investigated when prompt neutron decay constant sensitivity coefficients are utilized. This is important for new critical experiment design optimization studies of measurement configurations. This work provides a basis for more detailed sensitivity analysis and uncertainty quantification of nuclide, reaction, and energy-specific cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant at or Near Delayed Critical [Abstract]

Experimenters at Los Alamos National Laboratory (LANL) measure the prompt neutron decay constant for many experiments at the National Criticality Experiments Research Center (NCERC) to infer reactivity and the effective neutron multiplication factor. These quantities are very important for nuclear criticality safety and validating nuclear data. Uncertainty in measures of criticality of an experimental configuration can be determined prior to physically performing the experiment by applying first order perturbation theory to Monte Carlo codes, such as MCNP®. The first order perturbation theory produces first derivatives of some nuclear parameter to nuclear data (e.g., cross section data). This first derivative is commonly referred to as a sensitivity coefficient. Currently, the MCNP® software has the capability of computing effective neutron multiplication factor sensitivity coefficients to cross section data. This work builds off of this MCNP® capability and the first order perturbation theory to provide a method of calculating sensitivity coefficients for the prompt neutron decay constant at or near delayed critical to cross section data. The prompt neutron decay constant sensitivity coefficient calculated in this work does not depend on any modification of the MCNP® source code. Prompt neutron decay constant sensitivity coefficient calculations can be used to infer reactivity and effective neutron multiplication factor sensitivity coefficient values as well. By investigating the trends of prompt neutron decay constant sensitivity coefficients for nuclide-reaction pairs across energy spectra, experiments can be designed to maximize or minimize the uncertainty in the prompt neutron decay constant in a particular energy region, which can lead to further optimization studies. Prompt neutron decay constant sensitivity coefficients will be calculated for the Jezebel benchmark. Subsequently, these sensitivity coefficients will be used in a data assimilation process to determine if there is or are optimal experiments that can be performed to provide insight into adjustments of uncertain/inaccurate cross section data. Specifically, the effect of the prompt neutron decay constant sensitivity coefficients on the nuclear data-induced uncertainty in the effective neutron multiplication factor will be examined

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using Prompt Neutron Decay Constant Measurements to Obtain Additional Kinetics Information

Prompt neutron decay constant measurements are typically used to infer the prompt neutron lifetime in a chain-reacting system, but these measurements include much more information about the kinetics of the system. This work focuses specifically on the Rossi-α method of measuring the prompt neutron decay constant. The Rossi-α system of equations consists of five unknown parameters. With five unknowns and three equations, the system of equations solved by the Rossi-α measurement is under-determined. It has been postulated that a well posed problem can be formulated using independent measurement configurations on a single system. The external source strength, the effective delayed neutron fractions, and Diven’s parameter do not typically change for different configurations of a single experiment. If good detector geometry is chosen, the detector efficiency does not change for multiple measurements of a single experiment using Rossi-α measurements. By making these assumptions, there are only two unique variables. This knowledge can be used to solve for most of the unique parameters using two independent, unique Rossi-α measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining plutonium mass in spent fuel using Cf-252 interrogation with prompt neutron detection

{sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection is proposed as one of 14 NDA techniques to determine Pu mass in spent fuel assemblies (FAs). CIPN is a low-cost and portable instrument, and it looks like a modified fork detector combined with an active interrogation source. Fission chamber (FC) is chosen as neutron detector because of its insensitivity to {gamma} radiation. The CIPN assay is comprised of two measurements, a background count and an active count, without and with the {sup 252}Cf source next to the fuel respectively. The net signal above background is primarily due to the multiplication of Cf source neutrons caused by the fissile content. The capability of CIPN to detect diversion and to determine fissile content was quantified using MCNPX simulations. New schemes were proposed (such as burnup and cooling time correction, etc.) and the results show that the fissile content of a target spent fuel assembly can be determined using CIPN signal.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of prompt neutron generation time at the VIR-2M pulsed nuclear reactor

The prompt neutron generation time is measured in the core of the VIR-2M research nuclear reactor. The measurements are performed using the Babala method while the reactor is in the subcritical state. The VIR-2M reactor and the relevant experimental equipment are briefly described, and the experimental procedure and data processing technique are presented. It is shown that the prompt neutron generation time with empty experimental channels is 35 ± 1 μs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Testing The High-Energy Prompt Neutron Signature At Low Beam Energies

Prompt fission neutrons continue to be examined as a signature for detecting the presence of fissionable material. This technique exploits the neutron energy limitations inherent with photonuclear emissions from non-fissionable material, allowing prompt fission neutrons to be identified and engaged for detecting nuclear material. Prompt neutron signal measurements were acquired with bremsstrahlung endpoint energies of 6 MeV for 18 targets comprised of both fissionable and non-fissionable material; delayed neutron measurements were also collected as a reference. The {sup 238}U target was also shielded with increasing thicknesses of lead or borated polyethylene to compare the resulting detection rates of the prompt and delayed fission neutron signals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt neutron emission in the neutron-induced fission of 239 Pu and the spontaneous fission of 252 Cf: an unfolding story

Prompt neutron emission is one of the major observables in fission and critical to a sustained chain reaction. The prompt neutron emission spectrum and its precision are essential for adequately modeling the chain reaction for any given application. Within this context, a joint program, called Chi-Nu, was initiated by LANL [1] with the objective to improve the precision of experimental measurements of prompt neutron emission for neutron-induced fission of 235 U and 239 Pu as well as the spontaneous fission of 252 Cf. The measurements were carried out at the Weapons Neutron Research Facility at Los Alamos Neutron Science Center using two scintillator arrays for neutron detection and a PPAC (parallel-plate avalanche counter) for fission-fragment detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron-induced fission: properties of prompt neutron and γ rays as a function of incident energy

We have applied the Hauser-Feshbach statistical theory, in a Monte-Carlo implementation, to the de-excitation of fission fragments, obtaining a reasonable description of the characteristics of neutrons and gamma rays emitted before beta decays toward stability. Originally implemented for the spontaneous fission of 252 Cf and the neutroninduced fission of 235 U and 239 Pu at thermal neutron energy, in this contribution we discuss the extension of the formalism to incident neutron energies up to 20 MeV. For the emission of pre-fission neutrons, at incident energies beyond second-chance fission, we take into account both the pre-equilibrium and statistical pre-fission components. Phenomenological parameterizations of mass, charge and TKE yields are used to obtain the initial conditions for the fission fragments that subsequently decay via neutron and emissions. Finally, we illustrate this approach for 239 Pu(n,f).

74 ATOMIC AND MOLECULAR PHYSICS↗

Identifying Inconsistencies in Fission Product Yield Evaluations with Prompt Neutron Emission

Here, we present a self-consistency analysis of fission product yield evaluations. Anomalous yields are determined using a series of simple conservation checks and comparing charge distributions with common parameterizations. The summed average prompt neutron multiplicity for both products as a function of the heavy product mass is derived directly from the independent fission product yields with a procedure utilizing average charge conservation. This procedure is validated with Monte Carlo simulations of the de-excitation of the fission fragments in a Hauser-Feshbach statistical decay framework. The derived is compared with experimental data, when available, and then used to determine the prompt neutron multiplicity for the various evaluations. The propagated errors on from the average charge conservation method are significantly lower than the simple summation rules, which reveals that some evaluations are inconsistent with prompt neutron data. We propose possible solutions to remedy the observed inconsistencies and identify sources of the observed differences in between the various evaluation libraries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt Neutron Decay for Delayed Critical Bare and Natural-Uranium-Reflected Metal Spheres of Plutonium and Highly Enriched Uranium

Prompt neutron decay at delayed criticality was measured by Oak Ridge National Laboratory for uranium-reflected highly enriched uranium (HEU) and Pu metal spheres (FLATTOP), for an unreflected Pu metal (4.5% {sup 240}Pu) sphere (JEZEBEL) at Los Alamos National Laboratory (LANL) and for an unreflected HEU metal sphere at Oak Ridge Critical Experiments Facility. The average prompt neutron decay constants from hundreds of Rossi-{alpha} and randomly pulsed neutron measurements with {sup 252}Cf at delayed criticality are as follows: 3.8458 {+-} 0.0016 x 10{sup 5} s{sup -1}, 2.2139 {+-} 0.0022 x 10{sup 5} s{sup -1}, 6.3126 {+-} 0.0100 x 10{sup 5} s{sup -1}, and 1.1061 {+-} 0.0009 x 10{sup 6} s{sup -1}, respectively. These values agree with previous measurements by LANL for FLATTOP, JEZEBEL, and GODIVA I as follows: 3.82 {+-} 0.02 x 10{sup 5} s{sup -1} for a uranium core; 2.14 {+-} 0.05 x 10{sup 5} s{sup -1} and 2.29 x 10{sup 5} s{sup -1} (uncertainty not reported) for a plutonium core; 6.4 {+-} 0.1 x 10{sup 5} s{sup -1}, and 1.1 {+-} 0.1 x 10{sup 6} s{sup -1}, respectively, but have smaller uncertainties because of the larger number of measurements. For the FLATTOP and JEZEBEL assemblies, the measurements agree with calculations. Traditionally, the calculated decay constants for the bare uranium metal sphere GODIVA I and the Oak Ridge Uranium Metal Sphere were higher than experimental by {approx}10%. Other energy-dependent quantities for the bare uranium sphere agree within 1%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prompt Neutron Time Decay in Single HEU and DU Metal Annular Storage Castings

Previous measurements of highly enriched uranium (HEU) storage castings performed by Oak Ridge National Laboratory (ORNL) at the Y-12 National Security Complex showed a prompt neutron time decay that is not exponential. These measurements showed that multiple time constants originating from multiplication, time-of-flight, scattering in the assembly and room return could be associated with this prompt neutron decay. In this work, the contribution not associated with neutron multiplication was investigated via measurements with a depleted uranium (DU) casting. The measurements at ORNL used an annular (5.0-in OD, 3.5-in ID, 6.0-in H) DU casting with a time-tagged 252Cf source, centered vertically on the axis, and four closely coupled 1 1 6-in.-long plastic scintillators with -in.- thick lead shielding adjacent to the outer surface of the casting. This setup was identical to the configuration used in the previously performed measurements with HEU castings at Y-12. The time correlation between fission events and detections in the plastic scintillators was measured, as well as the time distribution of coincidences between multiple detectors within a 512-ns time window. The measurement results were then compared to MCNP-PoliMi calculations and the previous HEU measurements. Time constants from decay fits to the HEU and DU data were compared to characterize the contributions resulting from multiplication, time-of-flight, and scattering.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prompt Neutron Decay Constant from Feynman Variance Fitting

The use of fast-response liquid scintillators for passive measurements with highly enriched uranium (HEU) castings provides information on the timescale of the fission chain multiplication process for HEU. Thus, these detectors produce time responses characteristic of the HEU and not the moderator around 3He counters. Up to five HEU castings were assembled, and the passive time coincidence measurements performed. The prompt neutron decay constants inferred from the Feynman variance data with the arrays of large liquid scintillators are compared with decay constants obtained from previously presented Feynman variance data collected in active interrogation measurements with these same HEU castings. The active measurements used plastic scintillation detectors adjacent to the castings to eliminate time-of-flight effects and showed that the prompt neutron decay constant is clearly not exponential. However, time-of-flight effects in the passive measurements result in exponential behavior and allow the Feynman variance data to be fit with the well-known point kinetics analytical formula. The characterization of the prompt neutron decay constant is investigated by comparing the results of the passive and active measurement data.

36 MATERIALS SCIENCE↗

Prompt Neutron Decay Constants in a Highly Enriched Uranium-Lead Copper Reflected System

Rossi-{alpha} measurements were performed on highly enriched uranium (HEU)-lead copper reflected systems to determine the prompt neutron decay constants. These constants represent an eigenvalue characteristic of these particular critical configurations, which can be experimentally measured by the Rossi-a or pulse neutron source techniques and calculated by a deterministic or Monte Carlo method. In the measurements presented in this summary, highly enriched uranium interleaved with lead plates and reflected with copper were assembled to a high multiplication and the prompt neutron decay constants were determined by the Rossi-{alpha} technique. This research intended to benchmark the lead neutron cross sections; it was a collaboration between the Japanese Atomic Energy Agency (JAEA) Fast Critical Assembly Facility (FCA) in Tokai, Japan and the Los Alamos National Laboratory (LANL) in the U.S. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Prompt neutron multiplicity distributions inferred from γ -ray and fission fragment energy measurements

We propose a novel method to extract the prompt neutron multiplicity distribution, P(ν), in fission reactions based on correlations between prompt neutrons, γ rays, and fragment kinetic energy arising from energy conservation. In this approach, only event-by-event measurements of the total γ-ray energy released as a function of the total kinetic energy (TKE) of the fission fragments are performed, and no neutron detection is required. Using the cgmf fission event generator, we illustrate the method and explore the accuracy of extracting the neutron multiplicity distribution when taking into account the energy resolution and calibration of the energy measurements. In conclusion, we find that a TKE resolution of under 2 MeV produces reasonably accurate results, independent of typical γ-ray energy measurement resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗