Pulse risetimes in proportional counters.
Proportional counter pulse shapes calculation for point and extended ionization tracks, considering electron drift velocity and positive ion mobility
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Proportional counter pulse shapes calculation for point and extended ionization tracks, considering electron drift velocity and positive ion mobility
Proportional counter has increased sensitivity for high resolution X-ray surveys. It locates weak cosmic X-ray sources while reducing non-X-ray background.
Proportional counters are important instruments used in sensing hard x-rays. The possibility is described of doubling the number of readout channels in the detector without increasing the electronics needed to amplify channel signals. This suggests that it should be possible, conversely, to reduce the number of amplifiers, thereby reducing the weight and energy budget of the instrument. Various numerical multiplexing schemes are analyzed, and a computer program is presented that can reconstruct multiplexed channel outputs with very good accuracy.
Not Available
Age dating groundwater and seawater using 39Ar/Ar ratios is an important tool to understand water mass flow rates and mean residence time. For modern or contemporary argon, the 39Ar activity is 1.8 mBq per liter of argon. Radiation measurements at these activity levels require ultra low-background detectors. Low-background proportional counters have been developed at Pacific Northwest National Laboratory. These detectors use traditional mixtures of argon and methane as counting gas, and the residual 39Ar from commercial argon has become a predominant source of background activity in these detectors. We demonstrated sensitivity to 39Ar by using geological or ancient argon from gas wells in place of commercial argon. The low level counting performance of these proportional counters is then demonstrated for sensitivities to 39Ar/Ar ratios sufficient to date water masses as old as 1000 years.
An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with {sup 14}C/{sup 3}H, age-dating of groundwater with {sup 39}Ar, and soil-gas assay for {sup 37}Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of {sup 37}Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of {sup 37}Ar samples over a broad range of proportional counter operating pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for {sup 37}Ar soil gas background studies.
A proportional counter is introduced in which the levels of energy and spatial resolutions and background rejection permit the application of the device to X-ray astronomy. A multistep approach is employed in which photons cause a signal that triggers the system and measures the energy of the incident photon. The multistep approach permits good energy resolution from parallel geometry and from the imaging stage due to coupling of the imaging and amplification stages. The design also employs fluorescence gating to reduce background, a method that is compatible with the multistep technique. Use of the proportional counter is reported for NASA's supernova campaign, and the pair background is below 0.0001 counts/sq cm sec keV at the xenon k-edge. Potential improvements and applications are listed including the CASES, POF, and EXOSS mission programs.
Abstract. Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., 37Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counters (ULBPC) designs and now operate in PNNL’s shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of OFHC copper components for use in an above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of background rates, gas gain, energy resolution, and shielding considerations. These results will be presented along with uncertainty estimates of future absolute gas counting measurements.
Not Available
We present new results on the neutron detection efficiency of detection systems based on He-3 proportional counters compared to organic liquid scintillators. The experiments were conducted using a well-characterized Cf-252 neutron source, measured bare, and shielded with slabs of polyethylene. The results show that the intrinsic neutron detection efficiency for the bare source is approximately 25% for the He-3 system, and 67% for the liquid scintillator system. When polyethylene sheets were used to shield the source in 2.54 cm increments, the neutron detection efficiency of both systems decreased exponentially to approximately 10% for the case of 25.4 cm. Experimental results were simulated using MCNPX-PoliMi and good agreement was found between measurement and simulation results for all the cases considered here.
Beryllium proportional counters for satellite X ray astronomy, noting long term stability and environmental resistance
Design of proportional counter to record location and magnitude of cosmic X ray event
The Monitor Proportional Counter Instrument for the HEAO-B X-ray Telescope satellite is designed to observe celestial X-ray sources in the range of 1 to 20 keV with intensities exceeding .0002 Crab. It provides both spectral and temporal data, to complement the data from the other HEAO-B instruments, to compare with observations from previous flights, as well as to allow detailed study of time variant X-ray phenomena. The basic detector is a large area proportional counter system, consisting of two counters, high voltage power supplies and preamplifiers, mounted behind a collimator with a 2/3 degree square field of view. The signal processing, power distribution and control electronics are contained in a separate unit, which includes circuitry to perform pulse height analysis, background rejection, time interval measurement, redundancy switching and control, housekeeping and telemetry interfacing.
Xenon-filled proportional counters are used extensively in astronomy, particularly in the hard X-ray region. The choice of quench gas can have a significant effect on the operating characteristics of the instrument although the data necessary to make the choice are not easily obtainable. Results which detail the performance obtained from both cylindrical and parallel field geometries for a wide variety of readily available, ultrahigh or research grade purity, quench gases are presented.
A large-area multistep imaging proportional counter that is being currently developed at the Marshall Space Flight Center is described. The device, known as a multistep fluorescence gated detector, consists of a multiwire proportional counter (MWPC) with a preamplification region. The MWCP features superior spatial resolution with a very high degree of background rejection. It is ideally suited for use in X-ray astronomy in 20-100 keV energy range. The paper includes the MWPC schematic and a list of instrument specifications.
The characteristics of a conventional cylindrical geometry proportional counter filled with high pressure xenon gas up to 10 atm. were fundamentally investigated for use as a detector in hard X-ray astronomy. With a 2 percent methane gas mixture the energy resolutions at 10 atm. were 9.8 percent and 7.3 percent for 22 keV and 60 keV X-rays, respectively. From calculations of the Townsend ionization coefficient, it is shown that proportional counters at high pressure operate at weaker reduced electric field than low pressure counters. The characteristics of a parallel grid proportional counter at low pressure showed similar pressure dependence. It is suggested that this is the fundamental reason for the degradation of resolution observed with increasing pressure.
An imaging gas scintillation proportional counter (GSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1 micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The measured energy resolution is 17.0 percent (fwhm) and 8.0 percent (fwhm) at 1.5 keV and 5.9 keV, respectively. The measured position resolution is 1.9 mm (fwhm) and 0.9 mm (fwhm) at 1.5 and 5.9 keV, respectively. Possible astrophysical observations which can be performed with an IGSPC at the focal plane of a grazing incidence telescope are also discussed.