Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROSTHETICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Peri-prosthetic fracture vibration testing

The purpose of this study is to establish a test setup and vibration analysis method to predict femoral stem seating and prevent bone fracture using accelerometer or force response data from an instrument stem and impactor. This study builds upon earlier studies to identify a means to supplement a surgeon's tactile and auditory senses by using damage identification techniques normally used for civil and mechanical structures. Testing will be conducted using foam cortical shell sawbones prepared for stems of different geometries. Each stem will be instrumented with an accelerometer. Two impactor designs will be compared: a monolithic impactor with an integrated load cell and accelerometer and a two piece impactor. Acceleration and force measurements will be taken in the direction of impaction. Signal processing techniques will be applied to the acceleration time histories to determine features that can be used to assess device seating and potential fracture. A consistent energy input will be applied using a drop tower. The effect of introducing compliance under the bone support vise will also be investigated. The ultimate goal of this study is to design an integrated portable data acquisition system capable of being used in future cadaveric testing. This paper will discuss the experimental set-up, the signal processing techniques used and the subsequent results.

42 ENGINEERING↗

A Mobile Motion Analysis System Using Intertial Sensors for Analysis of Lower Limb Prosthetics

Soldiers returning from the global war on terror requiring lower leg prosthetics generally have different concerns and requirements than the typical lower leg amputee. These subjects are usually young, wish to remain active and often desire to return to active military duty. As such, they demand higher performance from their prosthetics, but are at risk for chronic injury and joint conditions in their unaffected limb. Motion analysis is a valuable tool in assessing the performance of new and existing prosthetic technologies as well as the methods in fitting these devices to both maximize performance and minimize risk of injury for the individual soldier. We are developing a mobile, low-cost motion analysis system using inertial measurement units (IMUs) and two custom force sensors that detect ground reaction forces and moments on both the unaffected limb and prosthesis. IMUs were tested on a robot programmed to simulate human gait motion. An algorithm which uses a kinematic model of the robot and an extended Kalman filter (EKF) was used to convert the rates and accelerations from the gyro and accelerometer into joint angles. Compared to encoder data from the robot, which was considered the ground truth in this experiment, the inertial measurement system had a RMSE of <1.0 degree. Collecting kinematic and kinetic data without the restrictions and expense of a motion analysis lab could help researchers, designers and prosthetists advance prosthesis technology and customize devices for individuals. Ultimately, these improvements will result in better prosthetic performance for the military population.

Mueller, John Kyle P↗

Multichannel haptic feedback unlocks prosthetic hand dexterity

Abstract Loss of tactile sensations is a major roadblock preventing upper limb-absent people from multitasking or using the full dexterity of their prosthetic hands. With current myoelectric prosthetic hands, limb-absent people can only control one grasp function at a time even though modern artificial hands are mechanically capable of individual control of all five digits. In this paper, we investigated whether people could precisely control the grip forces applied to two different objects grasped simultaneously with a dexterous artificial hand. Toward that end, we developed a novel multichannel wearable soft robotic armband to convey artificial sensations of touch to the robotic hand users. Multiple channels of haptic feedback enabled subjects to successfully grasp and transport two objects simultaneously with the dexterous artificial hand without breaking or dropping them, even when their vision of both objects was obstructed. Simultaneous transport of the objects provided a significant time savings to perform the deliveries in comparison to a one-at-a-time approach. This paper demonstrated that subjects were able to integrate multiple channels of haptic feedback into their motor control strategies to perform a complex simultaneous object grasp control task with an artificial limb, which could serve as a paradigm shift in the way prosthetic hands are operated.

60 APPLIED LIFE SCIENCES↗

Standardized uptake values in FDG PET/CT for prosthetic heart valve endocarditis: a call for standardization

Background: The significance of and threshold values for the standardized uptake value (SUV) in FDG PET/CT to diagnose prosthetic heart valve (PHV) endocarditis (PVE) are unclear at present. Methods: A literature search was performed in the PubMed and EMBASE medical databases, comprising the following terms: (FDG OR *fluorode* OR *fluoro-de*) AND (endocarditis OR prosthetic heart valve OR valve replacement). Studies reporting SUVs correlated to the diagnosis of PVE were selected for analysis. Results: 8 studies were included, with a total of 330 PHVs assessed. SUVs for PVE varied substantially across studies due to differences in acquisition, reconstruction, and measurement protocols, with median SUVmax values for rejected PVE ranging from 0.5 to 4.9 and for definite PVE ranging from 4.2 to 7.4. Conclusion: Reported SUV values for PVE are not interchangeable between sites, and further standardization of quantification is desirable. To this end, optimal protocols for patient preparation, image acquisition, and reconstruction and measurement methods need to be standardized across centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Purinyl-cobamide is a native prosthetic group of reductive dehalogenases

Here, cobamides such as vitamin B 12 are structurally conserved, cobalt-containing tetrapyrrole biomolecules that have essential biochemical functions in all domains of life. In organohalide respiration, a vital biological process for the global cycling of natural and anthropogenic organohalogens, cobamides are the requisite prosthetic groups for carbon–halogen bond-cleaving reductive dehalogenases. This study reports the biosynthesis of a new cobamide with unsubstituted purine as the lower base and assigns unsubstituted purine a biological function by demonstrating that Coα-purinyl-cobamide (purinyl-Cba) is the native prosthetic group in catalytically active tetrachloroethene reductive dehalogenases of Desulfitobacterium hafniense . Cobamides featuring different lower bases are not functionally equivalent, and purinyl-Cba elicits different physiological responses in corrinoid-auxotrophic, organohalide-respiring bacteria. Given that cobamide-dependent enzymes catalyze key steps in essential metabolic pathways, the discovery of a novel cobamide structure and the realization that lower bases can effectively modulate enzyme activities generate opportunities to manipulate functionalities of microbiomes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-612: Photonuclear Activation of Prosthetic Hips in Radiotherapy

Purpose: To measure the neutron induced activation of a prosthetic hip when exposed to an 18 MV radiotherapy linac beam to assess the potential dose to patients. Methods: A prosthetic hip (Thackray, UK) was placed in a water phantom and irradiated (both in-field and out-of-field) with an 18 MV linac beam. Gamma spectroscopy was used to identify the radioisotopes produced. Following the in-field irradiation where the induced activity is higher, high sensitivity lithium fluoride Thermoluminescence Dosimeters (TLD-100H) (Harshaw, USA) were placed on the surface to measure the dose which would be deposited to nearby tissue resulting from the induced radioactivity. Results: The radioisotopes produced in the hip prosthesis have been identified as {sup 5{sup 2}}V, {sup 5{sup 3}}Fe, and {sup 56}Mn which have half-lives of 3.74, 8.51 and minutes respectively. The 378 and 511 keV characteristic peaks of {sup 5{sup 3}}Fe do not appear in the spectra collected from hips irradiated in the out-of-field region. This isotope is produced by photonuclear interactions within the hip itself. {sup 52}V and {sup 56}Mn appear in spectra collected from hips irradiated either within the photon beam or in the nearby out-of-field region, implying that they are produced by incident neutron radiation produced in components of the linear accelerator.The integrated dose which would be deposited in the tissue immediately surrounding the hip after four hours (1.5 half-lives of the longest lived product) was measured as approximately 100 µGy, following a 10,000 MU irradiation of the prosthesis. A highly accurate measurement of the dose is challenging because of the irregular shape of the prosthesis. Conclusion: The cumulative dose measured at the surface of the hip is 0.0001% of the in-field dose, and is therefore negligible compared with the doses the patient receives as a consequence of their treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hierarchical Tactile Sensation Integration from Prosthetic Fingertips Enables Multi-Texture Surface Recognition

Multifunctional flexible tactile sensors could be useful to improve the control of prosthetic hands. To that end, highly stretchable liquid metal tactile sensors (LMS) were designed, manufactured via photolithography, and incorporated into the fingertips of a prosthetic hand. Three novel contributions were made with the LMS. First, individual fingertips were used to distinguish between different speeds of sliding contact with different surfaces. Second, differences in surface textures were reliably detected during sliding contact. Third, the capacity for hierarchical tactile sensor integration was demonstrated by using four LMS signals simultaneously to distinguish between ten complex multi-textured surfaces. Four different machine learning algorithms were compared for their successful classification capabilities: K-nearest neighbor (KNN), support vector machine (SVM), random forest (RF), and neural network (NN). The time-frequency features of the LMSs were extracted to train and test the machine learning algorithms. The NN generally performed the best at the speed and texture detection with a single finger and had a 99.2 ± 0.8% accuracy to distinguish between ten different multi-textured surfaces using four LMSs from four fingers simultaneously. The capability for hierarchical multi-finger tactile sensation integration could be useful to provide a higher level of intelligence for artificial hands.

Abd, Moaed A. (ORCID:0000000284954244)↗

Self-cleaning skin-like prosthetic polymer surfaces

An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.

36 MATERIALS SCIENCE↗

Mesofluidic controlled robotic or prosthetic finger

A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

42 ENGINEERING↗

Method of making self-cleaning skin-like prosthetic polymer surfaces

An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.

36 MATERIALS SCIENCE↗

Method of making self-cleaning skin-like prosthetic polymer surfaces

An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.

36 MATERIALS SCIENCE↗

Outcomes of Prosthetic Hemodialysis Grafts after Deployment of Bare Metal versus Covered Stents at the Venous Anastomosis

Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metal stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-time-point FDG PET/CT imaging in prosthetic heart valve endocarditis

Purpose: FDG PET/CT has been of increasing interest in the diagnostic workup of prosthetic heart valve endocarditis (PVE). Some reports advocate later imaging time points to improve the diagnostic accuracy for PVE. In this study, we compared standard and late FDG PET/CT images in patients with a clinical suspicion of PVE. Materials and Methods: Fourteen scans in 13 patients referred for FDG PET/CT for suspicion of PVE performed at standard (60 min post injection) and late (150 min post injection) time points were scored based on visual interpretation and semi-quantitatively with SUVmax and target-to-background ratio (TBR, defined as [SUVmax valve/SUVmean blood pool]). Final diagnosis was based on surgical findings in all cases of infection (n = 6) and unremarkable follow-up in all others (n = 8). Results: Late images were more prone to false positive interpretation for both visual and semi-quantitative analyses. Visual analysis of the standard images yielded 1 false negative and 1 false positive result. On the late images, no scans were false negative but 5 scans were false positive. Conclusion: Late FDG PET/CT imaging for PVE seems prone to false positive results. Therefore, late imaging should be interpreted with caution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recoil-Implantation Of Multiple Radioisotopes Towards Wear Rate Measurements And Particle Tracing In Prosthetic Joints

This study demonstrates a new method of radioisotope labeling of ultra-high molecular weight polyethylene inserts in prosthetic joints for wear studies. The radioisotopes {sup 97}Ru, {sup 100}Pd, {sup 100}Rh, and {sup 101m}Rh are produced in fusion evaporation reactions induced by {sup 12}C ions in a {sup 92}Zr target foil. The fusion products recoil-implant into ultra-high molecular weight polyethylene plugs, machined to fit into the surface of the inserts. During laboratory simulations of the joint motion, a wear rate of the labeled polyethylene may be measured and the pathways of wear debris particles can be traced by detecting characteristic gamma-rays. The concentration profiles of the radioisotopes extend effectively uniformly from the polyethylene surface to a depth of about 4 {mu}m. The multiplicity of labeling and the use of several gamma-ray lines aids with avoiding systematic measurement uncertainties. Two polyethylene plugs were labeled and one was fitted into the surface of the tibial insert of a knee prosthesis, which had been worn in. Actuation over close to 100,000 cycles with a 900 N axial load and a 24 deg. flexion angle removed (14{+-}1)% of the gamma-ray activity from the plug. Most of this activity dispersed into the serum lubricant identifying this as the important debris pathway. Less than 1% activity was transferred to the femoral component of the prosthesis and the measured activity on the tibial tray was insignificant. Assuming uniform wear across the superior surface of the insert, a wear rate of (12{+-}3) mm{sup 3}/Megacycle was determined. This is consistent with wear rate measurements under similar conditions using other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗