Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROTON DENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

TU-EF-BRA-01: NMR and Proton Density MRI of the 1D Patient

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

Enhancement of Proton Conductivity in Nonporous Metal–Organic Frameworks: The Role of Framework Proton Density and Humidity

Owing to their inherent pore structure, porous metal–organic frameworks (MOFs) can undergo postsynthetic modification, such as loading extra-framework proton carriers. However, strategies for improving the proton conductivity for nonporous MOFs are largely lacking, although increasing numbers of nonporous MOFs exhibit promising proton conductivities. Often, high humidity is required for nonporous MOFs to achieve high conductivities, but to date no clear mechanisms have been experimentally identified. Here we describe the new materials MFM-550(M), [M(HL 1 )], (H 4 L 1 = biphenyl-4,4'-diphosphonic acid; M = La, Ce, Nd, Sm, Gd, Ho), MFM-550(Ba), [Ba(H 2 L 1 )], and MFM-555(M), [M(HL 2 )], (H 4 L 2 = benzene-1,4-diphosphonic acid; M = La, Ce, Nd, Sm, Gd, Ho), and report enhanced proton conductivities in these nonporous materials by (i) replacing the metal ion to one with a lower oxidation state, (ii) reducing the length of the organic ligand, and (iii) introducing additional acidic protons on the MOF surface. Increased framework proton density in these materials can lead to an enhancement in proton conductivity of up to 4 orders of magnitude. Additionally, we report a comprehensive investigation using in situ 2H NMR and neutron spectroscopy, coupled with molecular dynamic modeling, to elucidate the role of humidity in assembling interconnected networks for proton hopping. This study constructs a relationship between framework proton density and the corresponding proton conductivity in nonporous MOFs, and directly explains the role of both surface protons and external water in assembling the proton conduction pathways.

36 MATERIALS SCIENCE↗

SU-E-J-233: Effect of Brachytherapy Seed Artifacts in T2 and Proton Density Maps in MR Images

Purpose: This study aims at investigating the influence of brachytherapy seeds on T2 and proton density (PD) maps generated from MR images. Proton density maps can be used to extract water content. Since dose absorbed in tissue surrounding low energy brachytherapy seeds are highly influenced by tissue composition, knowing the water content is a first step towards implementing a heterogeneity correction algorithm using MR images. Methods: An LDR brachytherapy (IsoAid Advantage Pd-103) seed was placed in the middle of an agar-based gel phantom and imaged using a 3T Philips MR scanner with a 168-channel head coil. A multiple echo sequence with TE=20, 40, 60, 80, 100 (ms) with large repetition time (TR=6259ms) was used to extract T2 and PD maps. Results: Seed artifacts were considerably reduced on T2 maps compared to PD maps. The variation of PD around the mean was obtained as −97% to 125% (±1%) while for T2 it was recorded as −71% to 24% (±1%). Conclusion: PD maps which are required for heterogeneity corrections are susceptible to artifacts from seeds. Seed artifacts on T2 maps, however, are significantly reduced due to not being sensitive to B0 field variation.

60 APPLIED LIFE SCIENCES↗

Measurement of spleen fat on MRI-proton density fat fraction arises from reconstruction of noise

Purpose: This study compares splenic proton density fat fraction (PDFF) measured using confounder-corrected chemical shift-encoded (CSE)-MRI to magnetic resonance spectroscopy (MRS) in human patients at 3T. Methods: This was a prospectively designed ancillary study to various previously described single-center studies performed in adults and children with known or suspected nonalcoholic fatty liver disease. Patients underwent magnitude-based MRI (MRI-M), complex-based MRI (MRI-C), high signal-to-noise variants (Hi-SNR MRI-M and Hi-SNR MRI-C), and MRS at 3T for spleen PDFF estimation. PDFF from CSE-MRI methods were compared to MRS-PDFF using Wilcoxon signed-rank tests. Demographics were summarized descriptively. Spearman’s rank correlations were computed pairwise between CSE-MRI methods. Individual patient measurements were plotted for qualitative assessment. A significance level of 0.05 was used. Results: Forty-seven patients (20 female, 27 male) including 12 adults (median 55 years old) and 35 children (median 12 years old). Median PDFF estimated by MRS, MRI-M, Hi-SNR MRI-M, MRI-C, and Hi-SNR MRI-C was 1.0, 2.3, 1.9, 2.2, and 2.0%. The four CSE-MRI methods estimated statistically significant higher spleen PDFF values compared to MRS (p < 0.0001 for all). Pairwise associations in spleen PDFF values measured by different CSE-MRI methods were weak, with the highest Spearman’s rank correlations being 0.295 between MRI-M and Hi-SNR MRI-M; none were significant after correction for multiple comparisons. No qualitative relationship was observed between PDFF measurements among the various methods. Conclusion: Overestimation of PDFF by CSE-MRI compared to MRS and poor agreement between related CSE-MRI methods suggest that non-zero PDFF values in human spleen are artifactual.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter-reader agreement of magnetic resonance imaging proton density fat fraction and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis

Purpose: To determine the inter-reader agreement of magnetic resonance imaging proton density fat fraction (PDFF) and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis (NASH). Study type: We performed a secondary analysis of a placebo-controlled randomized clinical trial of a bile acid sequestrant in 45 adults with NASH. A six-echo spoiled gradient-recalled-echo magnitude-based fat quantification technique was performed at 3 T. Three independent readers measured MRI-PDFF by placing one primary and two additional regions of interest (ROIs) in each segment at both time points. Cross-sectional agreement between the three readers was evaluated using intra-class correlation coefficients (ICCs) and coefficients of variation (CV). Additionally, we used Bland–Altman analyses to examine pairwise agreement between the three readers at baseline, end of treatment (EOT), and for longitudinal change. Results: Using all ROIs by all readers, mean PDFF at baseline, at EOT, and mean change in PDFF was 16.1%, 16.0%, and 0.07%, respectively. The 27-ROI PDFF measurements had 0.998 ICC and 1.8% CV at baseline, 0.998 ICC and 1.8% CV at EOT, and 0.997 ICC for longitudinal change. The 9-ROI PDFF measurements had corresponding values of 0.997 and 2.6%, 0.996 and 2.4%, and 0.994. Using 27 ROIs, the magnitude of the bias between readers for whole-liver PDFF measurement ranged from 0.03% to 0.06% points at baseline, 0.01% to 0.07% points at EOT, and 0.01% to 0.02% points for longitudinal change. Conclusion: Inter-reader agreement for measuring whole-liver PDFF and its longitudinal change is high. 9-ROI measurements have only slightly lower agreement than 27-ROI measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-IeP1-07: Inaccuracy of Lesion Blood Flow Quantification Related to the Proton Density Reference Image in Arterial Spin Labeling MRI of Brain Tumors

Purpose: Cerebral blood flow quantification in arterial spin labeling (ASL) MRI requires an estimate of the equilibrium magnetization of blood, which is often obtained by a set of proton density (PD) reference image. Normally, a constant blood-brain partition coefficient is assumed across the brain. However, this assumption may not be valid for brain lesions. This study aimed to evaluate the impact of lesion-related PD variations on ASL quantification in patients with brain tumors. Methods: MR images for posttreatment evaluation of 42 patients with brain tumors were retrospectively analyzed. These images were acquired on a 3T MRI scanner, including T2-weighted FLAIR, 3D pseudo-continuous ASL and post-contrast T1-weighted images. Anatomical images were coregistered with ASL images using the SPM software. Regions of interest (ROIs) of the enhancing and FLAIR lesions were manually drawn on the coregistered images. ROIs of the contralateral normal appearing tissues were also determined, with the consideration of approximating coil sensitivity patterns in lesion ROIs. Relative lesion blood flow (lesion/contralateral tissue) was calculated from both the CBF map (dependent on the PD) and the ΔM map for comparison. Results: The signal intensities in both enhancing and FLAIR lesions were significantly different than contralateral tissues on the PD reference image (p<0.001). The percent signal difference ranged from −15.9 to 19.2%, with a mean of 5.4% for the enhancing lesion, and from −2.8 to 22.9% with a mean of 10.1% for the FLAIR lesion. The high/low lesion-related PD signal resulted in inversely proportional under-/over-estimation of blood flow in both enhancing and FLAIR lesions. Conclusion: Significant signal differences were found between lesions and contralateral tissues in the PD reference image, which introduced errors in blood flow quantification in ASL. The error can be up to 20% in individual patients with an average of 5- 10% for the group of patients with brain tumors.

60 APPLIED LIFE SCIENCES↗

Critical fluctuations of the proton density in A+A collisions at 158A GeV

Here, we look for fluctuations expected for the QCD critical point using an intermittency analysis in the transverse momentum phase space of protons produced around midrapidity in the 12.5 % most central C+C, Si+Si and Pb+Pb collisions at the maximum SPS energy of 158A GeV. We find evidence of power-law fluctuations for the Si+Si data. The fitted power-law exponent Φ 2 =0.96 +0.38 –0.25 (stat.) ± 0.16 (syst.) is consistent with the value expected for critical fluctuations. Power-law fluctuations had previously also been observed in low-mass π + π – pairs in the same Si+Si collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Proton Density of States in Confined Water (H2O)

The hydrogen density of states (DOS) in confined water has been probed by inelastic neutron scattering spectra in a wide range of its P–T phase diagram. The liquid–liquid transition and the dynamical crossover from the fragile (super-Arrhenius) to strong (Arrhenius) glass forming behavior have been studied, by taking into account the system polymorphism in both the liquid and amorphous solid phases. The interest is focused in the low energy region of the DOS ( E < 10 meV) and the data are discussed in terms of the energy landscape (local minima of the potential energy) approach. In this latest research, we consider a unit scale energy (EC) linked to the water local order governed by the hydrogen bonding (HB). All the measured spectra, scaled according to such energy, evidence a universal power law behavior with different exponents ( γ ) in the strong and fragile glass forming regions, respectively. In the first case, the DOS data obey the Debye squared-frequency law, whereas, in the second one, we obtain a value predicted in terms of the mode-coupling theory (MCT) ( γ ≃ 1.6 ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light front synchronization and rest frame densities of the proton: Electromagnetic densities

We clarify the physical origin and meaning of the two-dimensional relativistic densities of the light front formalism. The densities are shown to originate entirely from the use of light front time instead of instant form time, which physically corresponds to using an alternative synchronization convention. This is shown by using tilted light front coordinates, which consist of light front time and ordinary spatial coordinates, and which are also used to show that the obtained densities describe a system at rest rather than at infinite momentum. These coordinates allow all four components of the electromagnetic current density to be given clear physical meanings. We explicate the formalism for spin-half targets, obtaining charge and current densities of the proton and neutron using empirical form factor parametrizations, as well as up and down quark densities and currents. Angular modulations in the densities of transversely polarized states are explained as originating from redshifts and blueshifts due to quarks moving in different longitudinal directions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ENERGETIC NEUTRAL HYDROGEN OBSERVATIONS DEMONSTRATE THAT VOYAGER 1 IS NOT OBSERVING THE EXTRAORDINARILY STRONG INTERSTELLAR MAGNETIC FIELD

It is generally believed that Voyager 1 ( V1 ) is now in interstellar space, having crossed the heliopause at a heliocentric distance of 121.58 au in late August of 2012. Here we use recently published spectra of energetic neutral hydrogen, and the magnetic field and energetic particles directly measured by V1 to find the average pressure in the inner heliosheath (termination shock to 122 au). This pressure turns out to be surprisingly large, (3.57 ± 0.71) × 10{sup −12} dyn cm{sup −2}, and is completely dominated by pressures of pickup ions (PUIs), created in the inner heliosheath, and their suprathermal tails (43%), and PUIs and their tails that are produced upstream of the termination shock and enter the heliosheath (46%). We compute the total particle pressure in the outer heliosheath near the heliopause from distribution functions of the interstellar plasma and locally created PUIs using profiles of proton density, proton temperature, and neutral hydrogen density from model 2 in Zank et al., and find it to be at most 7.7 × 10{sup −13} dyn cm{sup −2}. Balancing pressure across the heliopause, thus requires an unusually large magnetic pressure (2.8 × 10{sup −12} dyn cm{sup −2}). The resulting strength and 1 σ uncertainty of the draped magnetic field in the outer heliosheath near the heliopause is 0.839 ± 0.106 nT. The 3 σ lower limit field strength (0.52 nT) is greater than the field of ∼0.43 ± 0.02 nT measured by V1 , implying that there is less than 1% probability that V1 is measuring the interstellar draped field.

79 ASTRONOMY AND ASTROPHYSICS↗

Proton radiography of dynamic electric and magnetic fields in laser-produced high-energy-density plasmas

Time-gated, monoenergetic-proton radiography provides unique measurements of the electric (E) and magnetic (B) fields produced in laser-foil interactions and during the implosion of inertial-confinement-fusion capsules. These experiments resulted in the first observations of several new and important features: (1) observations of the generation, decay dynamics, and instabilities of megagauss B fields in laser-driven planar plastic foils, (2) the observation of radial E fields inside an imploding capsule, which are initially directed inward, reverse direction during deceleration, and are likely related to the evolution of the electron pressure gradient, and (3) the observation of many radial filaments with complex electromagnetic field striations in the expanding coronal plasmas surrounding the capsule. The physics behind and implications of such observed fields are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-EF-BRA-00: MR Basics I

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI (f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-02: Longitudinal Proton Spin Relaxation and T1-Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-03: Free Induction Decay (without the Decay) and Spin-Echo Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-04: Into 2, 3, and 4 Dimensions

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

LONG-TERM TRENDS IN THE SOLAR WIND PROTON MEASUREMENTS

We examine the long-term time evolution (1965–2015) of the relationships between solar wind proton temperature ( T {sub p}) and speed ( V {sub p}) and between the proton density ( n {sub p}) and speed using OMNI solar wind observations taken near Earth. We find a long-term decrease in the proton temperature–speed ( T {sub p}– V {sub p}) slope that lasted from 1972 to 2010, but has been trending upward since 2010. Since the solar wind proton density–speed ( n {sub p}– V {sub p}) relationship is not linear like the T {sub p}– V {sub p} relationship, we perform power-law fits for n {sub p}– V {sub p}. The exponent (steepness in the n {sub p}– V {sub p} relationship) is correlated with the solar cycle. This exponent has a stronger correlation with current sheet tilt angle than with sunspot number because the sunspot number maxima vary considerably from cycle to cycle and the tilt angle maxima do not. To understand this finding, we examined the average n {sub p} for different speed ranges, and found that for the slow wind n {sub p} is highly correlated with the sunspot number, with a lag of approximately four years. The fast wind n {sub p} variation was less, but in phase with the cycle. This phase difference may contribute to the n {sub p}– V {sub p} exponent correlation with the solar cycle. These long-term trends are important since empirical formulas based on fits to T {sub p} and V {sub p} data are commonly used to identify interplanetary coronal mass ejections, but these formulas do not include any time dependence. Changes in the solar wind density over a solar cycle will create corresponding changes in the near-Earth space environment and the overall extent of the heliosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Study Of The Solar Wind Parameters During The 23rd Solar Cycle

In this paper we study the solar wind parameters during the 23rd solar cycle and the possible correlation between them. Those parameters' data, which are Alfven Mach number, plasma beta, flow speed, proton density and temperature, dynamic pressure, average magnetic field, Bx and By, has been taken from OMNI 2. The first part of this project is about analysis and correlation of the data, using Pearson's product moment correlation coefficient and Spearman Rank Correlation Coefficient, during the 11 years of the 23rd cycle. The second part is about Wavelet analysis on those parameters during the 21st, 22nd, 23rd solar cycles in comparison with them. We found that each parameter has different behavior in every cycle and certain periodicities that appear constantly.

79 ASTRONOMY AND ASTROPHYSICS↗