Search NASA⌕ Search

SEARCH · Search NASA

Results for “PSF estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PSF Estimation in Crowded Astronomical Imagery as a Convolutional Dictionary Learning Problem

In this paper, we present a new algorithm for estimating the Point Spread Function (PSF) in wide-field astronomical images with extreme source crowding. Robust and accurate PSF estimation in crowded astronomical images dramatically improves the fidelity of astrometric and photometric measurements extracted from wide-field sky monitoring imagery. Our radically new approach utilizes convolutional sparse representations to model the continuous functions involved in the image formation. This approach avoids the need to detect and precisely localize individual point sources that is shared by existing methods. In experiments involving simulated astronomical imagery, it significantly outperforms the recent alternative method with which it is compared.

79 ASTRONOMY AND ASTROPHYSICS↗

Model-based PSF and MTF estimation and validation from skeletal clinical CT images

Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the scanner-specific parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dark Energy Survey Year 6 Results: Point-Spread Function Modeling

We present the point-spread function (PSF) modeling for weak lensing shear measurement using the full six years of the Dark Energy Survey (DES Y6) data. We review the PSF estimation procedure using the PIFF (PSFs In the Full FOV) software package and describe the key improvements made to PIFF and modeling diagnostics since the DES year three (Y3) analysis: (i) use of external Gaia and infrared photometry catalogs to ensure higher purity of the stellar sample used for model fitting, (ii) addition of color-dependent PSF modeling, the first for any weak lensing analysis, and (iii) inclusion of model diagnostics inspecting fourth-order moments, which can bias weak lensing measurements to a similar degree as second-order modeling errors. Through a comprehensive set of diagnostic tests, we demonstrate the improved accuracy of the Y6 models evident in significantly smaller systematic errors than those of the Y3 analysis, in which all g band data were excluded due to insufficiently accurate PSF models. For the Y6 weak lensing analysis, we include g band photometry data in addition to the riz bands, providing a fourth band for photometric redshift estimation. Looking forward to the next generation of wide-field surveys, we describe several ongoing improvements to PIFF, which will be the default PSF modeling software for weak lensing analyses for the Vera C. Rubin Observatory’s Legacy Survey of Space and Time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quickbird Satellite in-orbit Modulation Transfer Function (MTF) Measurement Using Edge, Pulse and Impulse Methods for Summer 2003

The spatial characteristics of an imaging system cannot be expressed by a single number or simple statement. However, the Modulation Transfer Function (MTF) is one approach to measure the spatial quality of an imaging system. Basically, MTF is the normalized spatial frequency response of an imaging system. The frequency response of the system can be evaluated by applying an impulse input. The resulting impulse response is termed the Point Spread function (PSF). This function is a measure of the amount of blurring present in the imaging system and is itself a useful measure of spatial quality. An underlying assumption is that the imaging system is linear and shift-independent. The Fourier transform of the PSF is called the Optical Transfer Function (OTF) and the normalized magnitude of the OTF is the MTF. In addition to using an impulse input, a knife-edge in technique has also been used in this project. The sharp edge exercises an imaging system at all spatial frequencies. The profile of an edge response from an imaging system is called an Edge Spread Function (ESF). Differentiation of the ESF results in a one-dimensional version of the Point Spread Function (PSF). Finally, MTF can be calculated through use of Fourier transform of the PSF as stated previously. Every image includes noise in some degree which makes MTF of PSF estimation more difficult. To avoid the noise effects, many MTF estimation approaches use smooth numerical models. Historically, Gaussian models and Fermi functions were applied to reduce the random noise in the output profiles. The pulse-input method was used to measure the MTF of the Landsat Thematic Mapper (TM) using 8th order even functions over the San Mateo Bridge in San Francisco, California. Because the bridge width was smaller than the 30-meter ground sample distance (GSD) of the TM, the Nyquist frequency was located before the first zero-crossing point of the sinc function from the Fourier transformation of the bridge pulse. To avoid the zero-crossing points in the frequency domain from a pulse, the pulse width should be less than the width of two pixels (or 2 GSD's), but the short extent of the pulse results in a poor signal-to-noise ratio. Similarly, for a high-resolution satellite imaging system such as Quickbird, the input pulse width was critical because of the zero crossing points and noise present in the background area. It is important, therefore, that the width of the input pulse be appropriately sized. Finally, the MTF was calculated by taking ratio between Fourier transform of output and Fourier transform of input. Regardless of whether the edge, pulse and impulse target method is used, the orientation of the targets is critical in order to obtain uniformly spaced sub-pixel data points. When the orientation is incorrect, sample data points tend to be located in clusters that result in poor reconstruction of the edge or pulse profiles. Thus, a compromise orientation must be selected so that all spectral bands can be accommodated. This report continues by outlining the objectives in Section 2, procedures followed in Section 3, descriptions of the field campaigns in Section 4, results in Section 5, and a brief summary in Section 6.

Helder, Dennis↗

Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system

Purpose: The purposes of this study is to measure the low frequency drop (LFD) of the modulation transfer function (MTF), associated with the long tails of the detector point spread function (PSF) of an on-board flat panel imager and study its impact on cone-beam CT (CBCT) image quality and scatter measurement accuracy. Methods: Two different experimental methods were used to characterize LFD and its associated PSF of a Varian OBI flat-panel detector system: the edge response function (ERF) method and the disk transfer function (DTF) method. PSF was estimated by fitting parametric models to these measurements for four values of the applied voltage (kVp). The resultant PSF was used to demonstrate the effect of LFD on image contrast and CT number accuracy in CBCT images reconstructed from synthetic datasets, as well as, accuracy of scatter measurements with the beam-stop method. Results: The MTFs derived from the measured ERF data revealed LFDs varying from 8% (at 60 kVp) to 10.5% (at 120 kVp), while the intensity of the long PSF tails was found to increase with increasing kVp. The veiling glare line spread functions derived from the ERF and DTF methods were in excellent agreement. Uncorrected veiling glare reduced contrast and the image intensity in CBCT reconstruction, near the phantom periphery (by 67 Hounsfield units in a 20 cm-in-diameter water phantom) and (to a smaller degree) near inhomogeneities. Use of the bow-tie filter mitigated these effects. Veiling glare also resulted in about 10%-15% overestimation of the scatter-to-primary ratio when measured with the beam-stop or beam-stop array method. Conclusions: The long tails of the detector PSF were found to have a modest dependence of beam spectrum, which is reflected on the MTF curve LFD. Our findings show that uncorrected veiling glare can affect quantitative accuracy and contrast in CBCT imaging, based on flat panel imager. In addition, it results in overestimation of the scatter-to-primary ratio, measured with the beam-stop methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uncertainty Quantification for Point Spread Functions in X-Ray Radiography

X-ray radiographers have tools for estimating the point spread function (PSF) which determines the extent of the blur in images. Knowledge of uncertainties in their estimations can be extremely valuable, and existing methods do not provide this information. We have developed a new technique using a Bayesian framework that will provide useful uncertainties to the estimated PSF.

point spread function↗

Point Spread Function Estimation and Uncertainty Quantification

An important component of analyzing images quantitatively is modeling image blur due to effects from the system for image capture. When the effect of image blur is assumed to be translation invariant and isotropic, it can be generally modeled as convolution with a radially symmetric kernel, called the point spread function (PSF). Standard techniques for estimating the PSF involve imaging a bright point source, but this is not always feasible (e.g. high energy radiography). This work provides a novel non-parametric approach to estimating the PSF from a calibration image of a vertical edge. Moreover, the approach is within a hierarchical Bayesian framework that in addition to providing a method for estimation, also gives a quantification of uncertainty in the estimate by Markov Chain Monte Carlo methods.

97 MATHEMATICS AND COMPUTING↗

Comparative point-spread function calculations for the MOMS-1, Thematic Mapper and SPOT-HRV instruments

Point-spread functions (PSF) comparisons were made between the Modular Optoelectronic Multispectral Scanner (MOMS-01), the LANDSAT Thematic Mapper (TM) and the SPOT-HRV instruments, principally near Lake Nakuru, Kenya. The results, expressed in terms of the width of the point spread functions at the 50 percent power points as determined from the in-scene analysis show that the TM has a PSF equal to or narrower than the MOMS-01 instrument (50 to 55 for the TM versus 50 to 68 for the MOMS). The SPOT estimates of the PSF range from 36 to 40. When the MOMS results are adjusted for differences in edge scanning as compared to the TM and SPOT, they are nearer 40 in the 575 to 625 nm band.

Salomonson, V. V.↗

Spatial resolution estimation of LANDSAT-4 TM and MSS data

In order to verify that the LANDSAT-4 sensors are operating within specifications, it is useful to estimate the system parameters by analysis of the measured data. One parameter of particular interest is the sensor point-spread function (PSF) which determines the resolution of the system. A method of estimating the PSF is described that utilizes data obtained during scanning of ground elements having identifiable geometric and radiometric structure. These data are then processed in such a manner as to recover either the PSF itself or to estimate the parameters of an assumed functional representation of the PSF.

Mcgillem, C. D.↗

Atmospheric Dispersion Effects in Weak Lensing Measurements

The wavelength dependence of atmospheric refraction causes elongation of finite-bandwidth images along the elevation vector, which produces spurious signals in weak gravitational lensing shear measurements unless this atmospheric dispersion is calibrated and removed to high precision. Because astrometric solutions and PSF characteristics are typically calibrated from stellar images, differences between the reference stars' spectra and the galaxies' spectra will leave residual errors in both the astrometric positions (dr) and in the second moment (width) of the wavelength-averaged PSF (dv) for galaxies.We estimate the level of dv that will induce spurious weak lensing signals in PSF-corrected galaxy shapes that exceed the statistical errors of the DES and the LSST cosmic-shear experiments. We also estimate the dr signals that will produce unacceptable spurious distortions after stacking of exposures taken at different airmasses and hour angles. We also calculate the errors in the griz bands, and find that dispersion systematics, uncorrected, are up to 6 and 2 times larger in g and r bands,respectively, than the requirements for the DES error budget, but can be safely ignored in i and z bands. For the LSST requirements, the factors are about 30, 10, and 3 in g, r, and i bands,respectively. We find that a simple correction linear in galaxy color is accurate enough to reduce dispersion shear systematics to insignificant levels in the r band for DES and i band for LSST,but still as much as 5 times than the requirements for LSST r-band observations. More complex corrections will likely be able to reduce the systematic cosmic-shear errors below statistical errors for LSST r band. But g-band effects remain large enough that it seems likely that induced systematics will dominate the statistical errors of both surveys, and cosmic-shear measurements should rely on the redder bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Astronomical imaging by filtered weighted-shift-and-add technique

The weighted-shift-and-add speckle imaging technique is analyzed using simple assumptions. The end product is shown to be a convolution of the object with a typical point-spread function (psf) that is similar in shape to the telescope psf and depends marginally on the speckle psf. A filter can be applied to each data frame before locating the maxima, either to identify the speckle locations (matched filter) or to estimate the instantaneous atmospheric psf (Wiener filter). Preliminary results show the power of the technique when applied to photon-limited data and to extended objects.

Ribak, Erez↗

X-ray evidence for particulate contamination on the AXAF VETA-1 mirrors

X-ray testing of the AXAF outer mirror pairs, in the VETA-1 configuration, reveals a point spread function (PSF) with unexpectedly large wings at low energies. Although the angular dependence in the wings of the PSF is close to that expected for diffractive scattering from surface roughness, the energy dependence differs substantially. Analyses of the observed X-ray PSF, images near ring focus, and single-quadrant images at conjugate focus suggest that the excess scattering observed at low X-ray energies results from diffractive scattering by relatively small grains (as small as a few tenths micrometer in radius). We develop a simple model for the contribution of scattering by particulates to the PSF. Merging this model with that for scattering by surface roughness, we fit the combined model to the observed energy-dependent PSF, in order to estimate parameters and associated uncertainties characterizing the grain-size distribution and the surface-roughness power spectral density. In particular, we find that the fractional coverage of the mirrors by particulates is approximately 1 x 10 exp -4 (for grain radii between 0.1 and 10 microns), and that the rms surface-roughness is approximately 0.7 nm (for spatial frequencies between 1/mm and 1000/mm).

O'Dell, S. L.↗

Spatial Resolution Estimation of LANDSAT-4 Thematic Mapper Data

The problem of estimating the overall point-spread function (PSF) of multispectral scanner systems was studied using real scene data and known geometric structures in the scene. A direct solution to an approximate form of the PSF was made along with a method using the derivative of an estimated edge response. Both results agreed closely. The TM scanner system specifications are given in line-spread function width and these values are listed with the experimental results in terms of meters. The estimated values are very reasonable, considering the number of factors which could be influencing the result. The atmosphere will have a blurring effect on the overall PSF as well as on cubic convolution resampling effects and possible electronic effects not accounted for in the specification. Also, the specific definition of the LSF specification is not known nor is the actual altitude at the instant the data were acquired. Thus the nominal overall PSF half-amplitude width of 39 m is reasonable; however, a greater sample of scene objects should be evaluated to furthur verify this result.

Mcgillem, C. D.↗

Galaxy–Galaxy Weak-lensing Measurements from SDSS. I. Image Processing and Lensing Signals

We present our image processing pipeline that corrects the systematics introduced by the point-spread function (PSF). Using this pipeline, we processed Sloan Digital Sky Survey (SDSS) DR7 imaging data in r band and generated a galaxy catalog containing the shape information. Based on our shape measurements of the galaxy images from SDSS DR7, we extract the galaxy–galaxy (GG) lensing signals around foreground spectroscopic galaxies binned in different luminosities and stellar masses. We estimated the systematics, e.g., selection bias, PSF reconstruction bias, PSF dilution bias, shear responsivity bias, and noise rectification bias, which in total is between −9.1% and 20.8% at 2 σ levels. The overall GG lensing signals we measured are in good agreement with Mandelbaum et al. The reduced χ {sup 2} between the two measurements in different luminosity bins are from 0.43 to 0.83. Larger reduced χ {sup 2} from 0.60 to 1.87 are seen for different stellar mass bins, which is mainly caused by the different stellar mass estimator. The results in this paper with higher signal-to-noise ratio are due to the larger survey area than SDSS DR4, confirming that more luminous/massive galaxies bear stronger GG lensing signals. We divide the foreground galaxies into red/blue and star-forming/quenched subsamples and measure their GG lensing signals. We find that, at a specific stellar mass/luminosity, the red/quenched galaxies have stronger GG lensing signals than their counterparts, especially at large radii. These GG lensing signals can be used to probe the galaxy–halo mass relations and their environmental dependences in the halo occupation or conditional luminosity function framework.

79 ASTRONOMY AND ASTROPHYSICS↗

The impact of light polarization effects on weak lensing systematics

ABSTRACT A fraction of the light observed from edge-on disc galaxies is polarized due to two physical effects: selective extinction by dust grains aligned with the magnetic field and scattering of the anisotropic starlight field. Since the reflection and transmission coefficients of the reflecting and refracting surfaces in an optical system depend on the polarization of incoming rays, this optical polarization produces both (a) a selection bias in favour of galaxies with specific orientations and (b) a polarization-dependent point spread function (PSF). In this work, we build toy models to obtain for the first time an estimate for the impact of polarization on PSF shapes and the impact of the selection bias due to the polarization effect on the measurement of the ellipticity used in shear measurements. In particular, we are interested in determining if this effect will be significant for Wide-Field Infrared Survey Telescope (WFIRST). We show that the systematic uncertainties in the ellipticity components are 8 × 10−5 and 1.1 × 10−4 due to the selection bias and PSF errors respectively. Compared to the overall requirements on knowledge of the WFIRST PSF ellipticity (4.7 × 10−4 per component), both of these systematic uncertainties are sufficiently close to the WFIRST tolerance level that more detailed studies of the polarization effects or more stringent requirements on polarization-sensitive instrumentation for WFIRST are required.

79 ASTRONOMY AND ASTROPHYSICS↗

Chromatic effects on the PSF and shear measurement for the Roman Space Telescope High-Latitude Wide Area Survey

Weak gravitational lensing (WL) is a key cosmological probe that requires precise measurement of galaxy images to infer shape distortions, or shear, and constrain cosmology. Accurate estimation of the point spread function (PSF) is crucial for shear measurement, but the wavelength dependence of the PSF introduces chromatic biases that can systematically impact shear inference. We focus on biases arising from spectral energy distribution (SED) differences between stars, used for PSF modelling, and galaxies, used for shear measurement. We investigate these effects in Roman’s four design reference mission WL bands (Y106, J129, H158, F184) and wide filter (W146). Using Roman-like image simulations, we quantify the induced shear biases and compare them to requirements on those biases. Multiplicative biases over all galaxies hover around ~0.2 per cent in the WL bands and 2 per cent in the wide filter, exceeding the mission requirement of |m| < 0.032 per cent and relaxed requirement of |m| < 0.1 per cent⁠. In individual redshift bins, biases can reach 0.4–0.9 per cent for the WL bands and 3–6 per cent for the wide filter. Additive biases remain acceptable in the WL bands but exceed systematic limits in the wide filter. We develop and test PSF-level corrections, showing that a first-order correction reduces biases within survey requirements for the WL bands; however, higher-order terms are necessary for the wide filter. Our results highlight the necessity of chromatic corrections for precision WL with Roman and provide a framework for mitigating these biases. Finally, we compare analytical colour-based corrections to self-organizing maps and find that both methods effectively reduce biases.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of a remote sensing system point-spread function from measured imagery

A general approach to identifying the point spread function (PSF) of a remotely sensed scene is demonstrated in terms of a step function for an abrupt change in the gray level along the row or column of the image data. The estimate of the PSF is made in terms of a finite sum of basis functions, employing a sequence of rectangular pulses covering the spatial extent of the PSF. The approximation, if narrow impulses are employed, provides accurate fidelity to the PSF. The method becomes practical when the geometrical structure of the scene elements producing the measured response is known. The field boundary is obtained through consideration of the differing intensities on each side of the boundary, which is a step discontinuity. The mathematical procedure for the technique is provided, together with a sample problem from Landsat-4 Thematic Mapper data. Atmospheric blurring and electronic effects on the overall PSF and the cubic convolution resampling effects are noted.

Mcgillem, C. D.↗

Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging

Purpose: X-ray cone-beam CT (CBCT) is being increasingly used for various clinical applications, while its performance is still hindered by image artifacts. This work investigates a new source of reconstruction error, which is often overlooked in the current CBCT imaging. The authors find that the x-ray flat field intensity (I{sub 0}) varies significantly as the illumination volume size changes at different collimator settings. A wrong I{sub 0} value leads to inaccurate CT numbers of reconstructed images as well as wrong scatter measurements in the CBCT research. Methods: The authors argue that the finite size of x-ray focal spot together with the detector glare effect cause the I{sub 0} variation at different illumination sizes. Although the focal spot of commercial x-ray tubes typically has a nominal size of less than 1 mm, the off-focal-spot radiation covers an area of several millimeters on the tungsten target. Due to the large magnification factor from the field collimator to the detector, the penumbra effects of the collimator blades result in different I{sub 0} values for different illumination field sizes. Detector glare further increases the variation, since one pencil beam of incident x-ray is scattered into an area of several centimeters on the detector. In this paper, the authors study these two effects by measuring the focal spot distribution with a pinhole assembly and the detector point spread function (PSF) with an edge-spread function method. The authors then derive a formula to estimate the I{sub 0} value for different illumination field sizes, using the measured focal spot distribution and the detector PSF. Phantom studies are carried out to investigate the accuracy of scatter measurements and CT images with and without considering the I{sub 0} variation effects. Results: On our tabletop system with a Varian Paxscan 4030CB flat-panel detector and a Varian RAD-94 x-ray tube as used on a clinical CBCT system, the focal spot distribution has a measured full-width-at-half-maximum (FWHM) of around 0.4 mm, while non-negligible off-focal-spot radiation is observed at a distance of over 2 mm from the center. The measured detector PSF has an FWHM of 0.510 mm, with a shape close to Gaussian. From these two distributions, the author calculate the estimated I{sub 0} values at different collimator settings. The I{sub 0} variation mainly comes from the focal spot effect. The estimation matches well with the measurements at different collimator widths in both horizontal and vertical directions, with an average error of less than 3%. Our method improves the accuracy of conventional scatter measurements, where the scatter is measured as the difference between fan-beam and cone-beam projections. On a uniform water cylinder phantom, more accurate I{sub 0} suppresses the unfaithful high-frequency signals at the object boundaries of the measured scatter, and the SPR estimation error is reduced from 0.158 to 0.014. The proposed I{sub 0} estimation also reduces the reconstruction error from about 20 HU on the Catphan Copyright-Sign 600 phantom in the selected regions of interest to less than 4 HU. Conclusions: The I{sub 0} variation is identified as one additional error source in x-ray imaging. By measuring the focal-spot distribution and detector PSF, the authors propose an accurate method of estimating the I{sub 0} value for different illumination field sizes. The method obtains more accurate scatter measurements and therefore facilitates scatter correction algorithm designs. As correction methods for other CBCT artifacts become more successful, our research is significant in further improving the CBCT imaging accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗