An asynchronous pulse amplitude pulse width model of the human operator
Asynchronous pulse amplitude, pulse width human operator model for producing discrete outputs in response to continuously presented Gaussian random inputs
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Asynchronous pulse amplitude, pulse width human operator model for producing discrete outputs in response to continuously presented Gaussian random inputs
Asynchronous pulse-amplitude pulse width model of human operator performance
Asynchronous pulse amplitude pulse width model of human operator
This dataset contains leaf gas exchange and Pulse-Amplitude Modulated (PAM) fluorometry for 98 C4 species. The C4 photosynthetic pathway employs specialized CO2 concentration mechanisms and Kranz anatomy to enrich CO2 concentration around Rubisco, the enzyme that catalyzes carbon fixation in the Calvin-Benson cycle to suppress photorespiration and increase the use efficiencies of light, nitrogen, and water as compared to the C3 photosynthetic pathways. Large-scale C4 photosynthetic datasets are relatively scarce, which has affected C4 photosynthesis research. To improve C4 photosynthetic data availability, Leafweb organized an effort to systematically collect, compile, standardize, and organize measurements of leaf gas exchange and/or Pulse-Amplitude Modulated (PAM) fluorometry of C4 species. This derived a C4 photosynthetic dataset containing measurements made by independent researchers in multiple countries in various environments (field, garden, or greenhouse). It covers three biochemical subtypes – the nicotinamide adenine dinucleotide phosphate-malic enzyme (NADP-ME), nicotinamide adenine dinucleotide-malic enzyme (NAD-ME), and phosphoenolpyruvate carboxykinase (PEP-CK) subtypes. This dataset is useful for using Artificial Intelligence / Machine Learning and mechanistic models to study C4 photosynthesis and compare across different biochemical subtypes. This dataset contains 3 compressed (*.zip) folders containing 1,892 data files in comma-separate values (*.csv) format. Additional metadata are provided: one data dictionary and a file-level metadata file in comma-separate values (*.csv) format and a user guide in PDF (*.pdf) format.
Transient signal generation by propagation of large amplitude pulses, discussing angular dependence in water
To provide data with long-term stability and accuracy, the pulse amplitude modulation (PAM) decommutator was synchronized to the PAM-return to zero wavetrain, and each channel was sampled with a common sample and hold circuit and digitized sequentially. The digital value of each channel was then scaled by the digital value of the calibration channels. The corrected digital value of each channel was stored for one complete frame and then transferred to the multiplexer-demultiplexer at a high rate in one block of serial digital data. A test model was built to demonstrate this design approach taken for the PAM decom and performance data was provided. The accuracies obtained with various signal to noise ratios are shown.
Output pulse amplitude from lithium-drifted detector-amplifier combination under conditions of carrier diffusion and bulk and surface recombination
We introduce a new method for analyzing the a periodic variability of coherent pulsations in accreting millisecond X-ray pulsars (AMXPs). Our method involves applying a complex frequency correction to the time-domain lightcurve, allowing for the aperiodic modulation of the pulse amplitude to be robustly extracted in the frequency domain. We discuss the statistical properties of the resulting modulation spectrum and show how it can be correlated with the non-pulsed emission to determine if the periodic and a periodic variability are coupled processes. Using this method, we study the 598.88 Hz coherent pulsations of the AMXP IGR J00291+5934 as observed with the Rossi X-ray Timing Explorer and XMM-Newton. We demonstrate that our method easily confirms the known coupling between the pulsations and a strong 8 mHz quasi-periodic oscillation (QPO) in XMM-Newton observations. Applying our method to the RXTE observations, we further show, for the first time, that the much weaker 20 mHz QPO and its harmonic are also coupled with the pulsations. We discuss the implications of this coupling and indicate how it may be used to extract new information on the underlying accretion process.
Transient signal generation during large amplitude ultrasonic pulse propagation through carbon tetrachloride
Electrical testing apparatus for detecting amplitude and width of transient pulse
Simple circuit that uses a single transistor to accomplish capacitor storage followed by common-base switching supplies a pulse voltage, higher than that normally available from emitter-follower circuits, to drive a 100-watt transmitter.
Closed-loop digital circuit, insensitive to drift with age, monitors input signals in particle detector. Basic elements of calibrator are clock circuit, weighting circuit, integrator, and chopper.
Laser altimeters measure the time of flight of the laser pulses to determine the range of the target. The simplest altimeter receiver consists of a photodetector followed by a leading edge detector. A time interval unit (TIU) measures the time from the transmitted laser pulse to the leading edge of the received pulse as it crosses a preset threshold. However, the ranging error of this simple detection scheme depends on the received, pulse amplitude, pulse shape, and the threshold. In practice, the pulse shape and the amplitude are determined by the target target characteristics which has to be assumed unknown prior to the measurement. The ranging error can be improved if one also measures the pulse width and use the average of the leading and trailing edges (half pulse width) as the pulse arrival time. The ranging error becomes independent of the received pulse amplitude and the pulse width as long as the pulse shape is symmetric. The pulse width also gives the slope of the target. The ultimate detection scheme is to digitize the received waveform and calculate the centroid as the pulse arrival time. The centroid detection always gives unbiased measurement even for asymmetric pulses. In this report, we analyze the laser altimeter ranging errors for these three detection schemes using the Mars Orbital Laser Altimeter (MOLA) as an example.
This paper explores direct density modulation of high-current electron beam emission from an RF cold cathode using optical excitation. We theoretically study the photo-assisted field emission of periodically bunched electron beams of various pulse shapes under the combined excitation of an RF field and an optical field, using an exact quantum model. Both continuous-wave (CW) and pulsed optical fields are considered. The emission current pulse amplitude, pulse width, electron number density per pulse, as well as pulse shape and its harmonic contents are investigated in detail. For CW photon sources in the UV to NIR range (i.e., 200–1200 nm), increasing the optical intensity under an RF bias tends to change the current pulse from a Gaussian to sinusoidal-like shape, thus offering strong flexibility to control the frequency components in beam current emission. Pulsed photon sources combined with an RF field can produce sharp, high-current electron bunches with pulse duration comparable with or even less than that of the optical pulse. A contour map of the density modulation depth is constructed for different combinations of RF and laser fields. The results provide insight into unlocking new opportunities to achieve direct density modulation during electron current emission by optical means.
Skilled pilots often use pulse control when controlling higher order (i.e. acceleration-command) vehicle dynamics. Pulsing does not produce a stick response that resembles what the human Crossover Model predicts. The Crossover Model (CM) assumes the pilot provides compensation necessary (lead or lag) such that the suite of display-human-vehicle approximates an integrator in the region of crossover frequency. However, it is shown that the CM does appear to drive the pilots pulsing behavior in a very predictable manner. Roughly speaking, the pilot generates pulses such that the area under the pulse (pulse amplitude multiplied by pulse width) is approximately equal to area under the hypothetical CM output. This can allow a pilot to employ constant amplitude pulsing so that only the pulse duration (width) is modulated a drastic simplification over the demands of continuous tracking. A pilot pulse model is developed, with which the parameters of the pilots internally-generated CM can be computed in real time for pilot monitoring and display compensation. It is also demonstrated that pursuit tracking may be activated when pulse control is employed.
A timing discriminator whose output is relatively insensitive to input pulse width and amplitude is described. The video-handling technique is known as slope reversal processing and is based on tapped delay line estimation methods. The concept, design, breadboard construction, and preliminary laboratory test results are reviewed. The processor system features (1) a peak input voltage dynamic range of 80x starting at 100 microvolts; (2) a four stage preamplifier/line-driver having a voltage gain of 2400x; (3) a tapped delay-line estimator implemented for slope reversal triggering by differential comparison; (4) a nominal plus or minus 2.5 nsec shift of the output trigger leading edge over the entire input voltage range, (5) up to 7 dB discrimination against pulse widths less than 35 nsec; and (6) up to one order of magnitude reduction in the false alarm rate compared to a constant fraction system.
Far scrape-off layer fluctuations, also known as blobs/filaments, are compared for the first time across six tokamaks: Alcator C-Mod, DIII-D, TCV, KSTAR, MAST, and MAST-U, under the context of stochastic modeling in Ohmic and low confinement mode scenarios. In this model, which well describes these fluctuations, measurements from Langmuir probes are modeled as a superposition of uncorrelated, two-sided exponential temporal pulses. The key parameters of this model are the mean waiting times between consecutive pulses, the pulse duration times and the mean of the pulse amplitudes. The study examines the influence of line-averaged density, plasma current, magnetic field and aspect ratio. The mean amplitudes and pulse waiting times increase with the line-averaged density across devices, while the pulse duration times remain constant. Whereas the variation in waiting times is gradual across the density scan, the mean amplitudes increase abruptly as the density profile broadens and flattens for Alcator C-Mod. The blob waiting times decrease with increasing plasma current and the toroidal magnetic field, while they increase with aspect ratio for conventional tokamaks. The duration times follow the same trends as the waiting times in these parameters but vary more slowly, resulting in the trends in the waiting times dominating the intermittency level of the fluctuations.
The rates of cooling afforded by thermoelectric (Peltier) devices can be increased for short times by applying pulses of electric current greater than the currents that yield maximum steady-state cooling. It has been proposed to utilize such momentary enhancements of cooling in applications in which diode lasers and other semiconductor devices are required to operate for times of the order of milliseconds at temperatures too low to be easily obtainable in the steady state. In a typical contemplated application, a semiconductor device would be in contact with the final (coldest) somewhat taller stage of a multistage thermoelectric cooler. Steady current would be applied to the stages to produce steady cooling. Pulsed current would then be applied, enhancing the cooling of the top stage momentarily. The principles of operation are straightforward: In a thermoelectric device, the cooling occurs only at a junction at one end of the thermoelectric legs, at a rate proportional to the applied current. However, Joule heating occurs throughout the device at a rate proportional to the current squared. Hence, in the steady state, the steady temperature difference that the device can sustain increases with current only to the point beyond which the Joule heating dominates. If a pulse of current greater than the optimum current (the current for maximum steady cooling) is applied, then the junction becomes momentarily cooled below its lowest steady temperature until thermal conduction brings the resulting pulse of Joule heat to the junction and thereby heats the junction above its lowest steady temperature. A theoretical and experimental study of such transient thermoelectric cooling followed by transient Joule heating in response to current pulses has been performed. The figure presents results from one of the experiments. The study established the essential parameters that characterize the pulse cooling effect, including the minimum temperature achieved, the maximum temperature overshoot, the time to reach minimum temperature, the time while cooled, and the time between pulses. It was found that at large pulse amplitude, the amount of pulse supercooling is about a fourth of the maximum steady-state temperature difference. For the particular thermoelectric device used in one set of the experiments, the practical optimum pulse amplitude was found to be about 3 times the optimum steady-state current. In a further experiment, a pulse cooler was integrated into a small commercial thermoelectric threestage cooler and found to provide several degrees of additional cooling for a time long enough to operate a semiconductor laser in a gas sensor.