Search NASASearch

SEARCH · Search NASA

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cost‐Effective Layered Oxide – Olivine Blend Cathodes for High‐Rate Pulse Power Lithium‐Ion Batteries

Abstract Sustainability and supply‐chain concerns require lithium‐ion batteries (LIBs) free from critical minerals, such as nickel and cobalt. While recent advances provide encouraging signs that cobalt can be removed, the question remains how much Ni can be removed from Co‐free layered oxide cathodes before sacrificing critical performance metrics. This study highlights the effect of reducing Ni by benchmarking several Co‐free cathodes with decreasing Ni content. Keeping the energy density the same by increasing the charge voltage, cathodes below 80% Ni content exhibit worsened capacity fade due to increasing oxygen release and electrolyte decomposition. Charge transfer and diffusion kinetics are also hindered with increasing Mn content and exacerbated by resistive surface phases formed at high voltages, rendering lower‐Ni, Co‐free cathodes less competitive than high‐Ni cathodes for high energy and power applications. It is demonstrated blending layered oxide with olivine as an effective alternative to deliver energy density and cycling stability comparable to lower‐Ni cathodes with moderate charging voltages. Blending with 30 wt% olivine LiMn 0.5 Fe 0.5 PO 4 (LMFP) virtually eliminates the diffusion limitation of layered oxides at low state‐of‐charge, with enhanced pulse power characteristics rivaling the high‐Ni counterparts. Cathode blending can further reduce the overall Ni content and cost without the performance limitations of lower‐Ni, Co‐free cathodes.

Lee, Steven

Impact of ultrafast laser pulse repetition rate on filament acoustic and emission signatures

Femtosecond filaments formed at standoff distances can be used for interrogating various types of matter, making them of potential interest for remote sensing. However, the physical aspects of the filaments generated at standoff distances are influenced by various environmental and laser properties, including the repetition rate of the laser. In this study, we evaluate the role of the predecessor pulse on the properties of filaments by varying the repetition rate of the laser in the range of 10–1000 Hz and using acoustic and emission signatures to diagnose filament properties. Our results show that filaments are brighter at high repetition rates while they are elongated at low repetition rates. The repetition rate has minimal influence on the downstream edge of the filament generation, while the upstream edge becomes elongated. The shadowgram images showed that the turbulence generated by the predecessor pulse may influence the next pulse when the laser is operating at high repetition rates.

47 OTHER INSTRUMENTATION

Overcoming energy limitation in post-compression of picosecond pulses by free beam propagation in air and temporal pulse splitting and recombining

Cryogenically cooled diode-pumped Yb:YAG has been demonstrated to efficiently generate pulses of >1 J energy and several picoseconds duration at a kilohertz repetition rate. Pulse broadening and post-compression techniques capable of operating at these high pulse energies will expand the use of these lasers in applications requiring shorter pulses. Towards this goal, we demonstrate the post-compression of 5.5 ps pulses with energy in the 0.1 J range by spectral broadening of self-collimated large area beams in air. In proof-of-principle experiments, pulses of 65 mJ energy from a cryogenically cooled Yb:YAG laser were compressed to 1.1 ps after 65 m propagation in a compact setup in which the beam was folded using flat mirrors. Further energy scaling was demonstrated by combining this spectral broadening technique with temporal pulse splitting and recombining. 120 mJ pulses were split into two pulses and coherently recombined with 85% efficiency after 50 m of propagation in air to yield 1.4 ps pulses.

High Energy Laser

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan II (PIP-II) project is a vital upgrade to the Fermilab accelerator complex. The magnet pulse rate of the PIP-II Injection system requires an increase from the current rate of 15 Hz to 20 Hz as well as a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) pulsed dipole magnets in the Booster. Here, the ORBUMP magnet mechanical design is presented in this paper. The ORBUMP magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic magnesium phosphate coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled, single turn coil, which shapes the magnetic field by acting as the pole tips, is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The coil is electrically isolated from the core using virgin Polyether ether ketone (PEEK) insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted via partial discharge testing using a 1:1 scale sample.

Karas, D. [Fermi National Accelerator Laboratory (

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction

LAMP Technical Readiness Evaluation Report

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risk to the project. These recent design modifications include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (ie choppers, kickers, and bunchers). • An additional H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional RFQ design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project KPPs. • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Three subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS

LAMP Technical Readiness Evaluation Report: LAMP-ENG-RPT-003 (Revision 2)

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risks to the project. These recent design modifications are based on the LAMP Conceptual Design which is the design evaluated in this document and include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (i.e. choppers, kickers, and bunchers). • An additional 100-keV H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H - ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional 3-MeV Radio Frequency Quadrupole (RFQ) design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project Key Performance Parameters (KPPs). • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages.

43 PARTICLE ACCELERATORS

Optically Stimulated Luminescence Data Storage (Abstract)

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING

A high repetition rate millimeter wavelength accelerator for an X-ray free-electron laser

A compact collinear wakefield accelerator has been designed for an X-ray free-electron laser capable of operating at a pulse repetition rate in the tens of kilohertz. The maximum achievable accelerating gradient has been determined, with its limitation linked to beam breakup instability. The fabrication techniques for the principal components of the accelerator including wakefield generation, couplers for excess power extraction and diagnostics, focusing quadrupoles, and a novel undulator have been discussed. Results from various laboratory and beam-based tests on these components have been compared to their original design specifications and demonstrated very good agreement. A preliminary design for the XFEL has been presented, featuring a novel small-period, force-neutral, adjustable-phase undulator.

26 undulator

Near-complete extraction of maximum stored energy from large-core fibers using coherent pulse stacking amplification of femtosecond pulses

High field science relies on ultrashort pulse lasers with multi-joule pulse energies for studying light–matter interactions under extreme conditions and for driving particle accelerators and secondary radiation sources of x rays, gamma rays, neutrons, positrons, muons, and protons. Next-generation laser drivers will require a 10 3 -10 4 times increase in pulse repetition rates, producing multi-joule energies at multi-kilowatt average powers to enable practical applications in nuclear engineering, advanced materials, medicine, biology, homeland security, and high-energy physics. Spatially coherently combined femtosecond fiber lasers are recognized as a pathway to these next-generation drivers, with significant practical advantages including high efficiency and the possibility of compact integration. However, chirped pulse amplification in fibers is capable of extracting only a small fraction (usually ~1%) of the maximum stored energy. Here we demonstrate near-complete maximum stored energy extraction with low accumulated nonlinearity from a large-core fiber amplifier using coherent pulse stacking amplification. We have amplified a 81-pulse stacking burst in a 85 µm core chirally coupled core Yb-doped fiber, extracting up to 9.5 mJ (~90% of stored energy) with < 4.5 radians of accumulated nonlinear phase, temporally combined this burst into a single pulse, and achieved 4.2 mJ pulses of 313 fs bandwidth-limited duration after compression. This represents, to our knowledge, the highest energy extracted and compressed into a femtosecond pulse from a single fiber amplifier, enabling approximately two orders of magnitude size reduction of future high-energy coherently spatially combined fiber laser arrays.

47 OTHER INSTRUMENTATION

Online Bayesian State Estimation for Real-Time Monitoring of Growth Kinetics in Thin Film Synthesis

Rapid validation of newly predicted materials through autonomous synthesis requires real-time adaptive control methods that exploit physics knowledge, a capability that is lacking in most systems. Here, in this study, we demonstrate an approach to enable real-time control of thin film synthesis by combining in situ optical diagnostics with a Bayesian state estimation method. We developed a physical model for film growth and applied the direct filter (DF) method for real-time estimation of nucleation and growth rates during pulsed laser deposition (PLD). We validated the approach using simulated and experimental reflectivity data for WSe 2 growth and ultimately deployed the algorithm on an autonomous PLD system during the growth of 1T'-MoTe 2 . The DF robustly estimates growth parameters in real time at early stages of growth, down to 15% monolayer area coverage. This fusion of in situ diagnostics, data assimilation, and physical modeling opens new opportunities in adaptive control of synthesis trajectories toward desired material states.

36 MATERIALS SCIENCE

Hydrological controls of a riparian wetland based on stable isotope data and model simulations

Isotopic evidence of groundwater and stream water is frequently used to investigate water exchanges with groundwater. Monthly sampling of rain, stream water, and groundwater was conducted at Tims Branch watershed in South Carolina for the oxygen and hydrogen stable isotope (δ 2 H and δ 18 O) measurement, as well as pH and oxidation–reduction potential (ORP). Together with a mass balance perspective, it was determined that it takes a few weeks to one month for groundwater in the hyporheic zone to fully exchange with stream water. From hydrodynamic modelling, we show that substantial (up to 70 %) groundwater exchange occurs at gaining and losing sites. Groundwater exfiltration, i.e. inflow into stream water, contributes up to 4 % to stream water, with the remainder from upstream exfiltration. A 2–4 % per day renewal rate of adjacent groundwater would indirectly indicate a groundwater residence time in the order of half a month to a full month (assuming either a well-mixed case or large dispersion rate in pulse flow case), in agreement with a greatly reduced variability of δ 2 H and δ 18 O of groundwater compared to stream water and rain. This reduced variability of stable isotope signal from groundwater confirms our hypothesis that riparian groundwater mixing at Tims Branch is more of a mixed type rather than a pulse flow type. As a result, a monthly time scale is sufficient for groundwater to become anoxic at exit points into stream water resulting in the episodic production of natural organic matter- and iron-rich flocs upon oxidation.

54 ENVIRONMENTAL SCIENCES

Non-intrusive measurement of magnetic field strengths in a low-pressure argon plasma using quantum beat spectroscopy

Abstract Accurate measurement of magnetic field strengths is critical in many plasma environments, ranging from astrophysical systems to fusion energy research. In this work, a non-perturbative laser-based optical diagnostic known as quantum beat spectroscopy is demonstrated to be good alternative for measuring the magnetic field strength in low-pressure laboratory plasmas. The technique is investigated using both ns and fs pulsed lasers in an argon plasma. Preliminary results for a helium plasma are also given. Zeeman-split J = 1 electron states with transitions from metastable states were identified and tested for neutral argon ( 2 P 1 / 2 o ) 4 p 2 [ 1 / 2 ] and neutral helium 1 s 3 p 1 P 1 o . Magnetic fields are measured with sub-Gauss precision at near single laser pulse acquisition rates.

Gilbert, Tyler J. (ORCID:0000000160400119)

Real-Time Ethernet Interface for NSTX-U’s Thomson Scattering Diagnostic (2023)

Here, the multipoint Thomson scattering (MPTS) diagnostic system at the National Spherical Torus Experiment Upgrade (NSTX-U) facility is undergoing an upgrade to operate in real-time and interface with the plasma control system (PCS) for NSTX-U. Previous prototyping efforts have shown that spectral analysis and rapid calculations of electron temperature and density are possible on a real-time Linux machine when using up to a 100-Hz laser pulse repetition rate. A remaining challenge was transferring the real-time data to NSTX-U’s PCS, which utilizes the front panel data port (FPDP) protocol. The original proposed method was to convert the real-time data into analog values, but a new solution was developed to keep the output format digital by using an Ethernet controller with a field-programmable gate array (FPGA). This article focuses on a new input module that has been developed to accept incoming user datagram protocol (UDP) packets sent over Ethernet, convert into FPDP format, and integrate into the existing data stream under NSTX-U’s real-time framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan-II (PIP-II) is a vital upgrade to Fermilab's accelerator complex. The upgrade is designed to power the world s most intense high-energy neutrino beam in future experiments. The magnet pulse repetition rate of the PIP-II injection system is being upgraded from 15 Hz to 20 Hz and requires a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) magnets in the Booster. The magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled single turn coil is electrically isolated from the core using virgin PEEK insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted. The design of the coil which shapes the magnetic field by acting as the pole tips is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The ORBUMP magnet mechanical design is presented in this paper.

Karas, Dino [Fermilab] (ORCID:0000000304340670)

Pulse-by-pulse transient thermal deformation in crystal optics under high-repetition-rate FEL

Time-domain modeling of the thermal deformation of crystal optics can help define acceptable operational ranges across the pulse-energy repetition-rate phase space. In this paper, we have studied the transient thermal deformation of a water-cooled diamond crystal for a cavity-based X-ray free-electron laser (CBXFEL), either an X-ray free-electron laser oscillator (XFELO) or a regenerative amplifier X-ray free-electron laser (RAFEL), by numerical simulations including finite-element analysis and advanced data processing. Pulse-by-pulse transient thermal deformation of a 50 µm-thick diamond crystal has been performed with X-ray pulse repetition rates between 50 kHz and 1 MHz. Results for temperature and thermal deformation have been compared with the results of transient analysis using a continuous wave (CW) power loading. Temperature and thermal deformation results from pulse-by-pulse transient analysis vary with time about the results for the CW case for the same average power. The variation amplitude increases with pulse energy and decreases with repetition rate. When the repetition rate increases to infinity, both temperature and thermal deformation converge to the results for the CW case. Two critical time scales for the operation of crystal optics in a CBXFEL are (1) first-turn time, i.e. the time for the XFEL pulse to complete the first turn around the cavity so that the crystal sees the recirculated XFEL pulse, and (2) period-end time, i.e. the time that the next electron bunch arrives for the amplification, so that the crystal outcouples the amplified FEL power. For the same average power, simulation results show that the crystal thermal deformation seen by the XFEL beam decreases with repetition rate at the first-turn time of a 300 m-long cavity and increases with repetition rate at the period-end time. For the wavefront preservation requirement of the crystal optics, a pulse-energy versus repetition-rate phase space has been established. The upper bounds of the pulse energy at both first-turn and period-end times decreases with repetition rate, especially at the period-end time. The upper bound of the thermal deformation of the crystal at the period-end time for any repetition frequency can be estimated from the CW case. For a water-cooled diamond crystal of dimension 5 mm × 5 mm × 0.05 mm, the time to reach a quasi steady-state is about 50 ms for temperature and 50 µs for thermal deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

A Methodology for determining optimal milling parameters for low-taper microtensile sample production

Femtosecond lasers are beginning to see an increase in interest for industrial and high throughput microsample milling applications. Despite this, much of the literature regarding removal rate studies for ultrashort pulse laser milling continues to focus on single-pulse or similar experiments that have a very small time on target. The material volume removal rates of femtosecond milling can vary wildly depending on parameters like laser scan speed, hatch spacing, z-axis step size, and pulses on the material. Currently, there is no established methodology for determining the optimal values of these parameters for micromilling applications. This methodology was developed in this study. The methodology consists of a pulse study, a repeat study, and a z-step study that will return the milling parameters that resulted in the largest volume removal rate for the laser used for this research. The methodology was created for the laser system used in this study, and was tested on 316 Stainless Steel, but was developed in such a way that it may be adapted to any material, and with some tweaking of variables might be used in other laser systems. The laser system used in this study utilizes a novel positioning stage that introduces 6 degrees of freedom to the translation of laser samples, being able to tilt and move in all three axes. Using both the developed methodology and the unique capabilities of the laser microtensile samples were produced with taper angles of <1° in 316 Stainless Steel.

Barker, Zachary Wayne

Neuromorphic ionic computing in droplet interface synapses

Ionic devices with memory capabilities can emulate neural functionality, enabling neuromorphic computing and biomedical applications. In this study, we report an ionic spiking synapse based on aqueous droplet interface bilayer assembly. Under stepwise triangular voltages, the device displays coupled memcapacitive-memristive behavior, showing noncrossing pinched hysteretic I-V loops. This hysteretic ion dynamics can be regulated by modifying bilayer components, reconstituting protein channels, or adjusting droplet assembly configuration. Droplet interface synapses (DIS) exhibit fundamental neuromorphic behaviors such as paired-pulse facilitation/depression, spike rate–dependent plasticity, Hebbian learning, and short-term associative learning under classical conditioning. We also used reservoir computing with DIS to implement two learning algorithms: a classification algorithm that recognizes handwritten digits and a reinforcement learning algorithm that learns to play a board game of tic-tac-toe.

Li, Zhongwu [Lawrence Livermore National Laborator