Quality control of electroexplosive devices by nondestructive pulse techniques
Nondestructive pulse technique for quality control of electroexplosive devices, noting cost reduction
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Nondestructive pulse technique for quality control of electroexplosive devices, noting cost reduction
Ultrasonic pulse techniques have been developed which, when applied to inert gases, provide temperature measurements up to 8000 K. The response time can be less than 1 msec. This is a significant feature in studying shock-heated or combusting gases. Using a momentary contact coupling technique, temperature has been measured inside steel from 300 to 1500 K. Thin-wire sensors have been used above 2000 K in nuclear and industrial applications where conditions preclude the use of thermocouples, resistance devices, or optical pyrometers. At 2500 K, temperature sensitivity of 0.1% is obtained in Re wire sensors 5 cm long by timing five round trips with an electronic instrument that resolves the time interval between selected echoes to 0.1 microsec. Sensors have been operated at rotational speeds over 2000 rpm and in noisy environments. Temperature profiling of up to ten regions using only a single guided path or beam has also been accomplished.
Pulsing techniques to improve fuel cell performance
Recently, the coded long-pulse radar technique was tested at Arecibo Observatory, Puerto Rico using photoelectron-enhanced plasma lines in the daytime ionosphere. The technique immediately proved to be a powerful diagnostic tool for studying natural ionospheric phenomena. Our initial observations indicate that extremely accurate measurements of absolute electron density (0.01 to 0.03% error bars) can be achieved with an altitude resolution of 150 m and a temporal resolution of approx. 2 s. In addition, the technique provides information about electron density structure within a 150-m altitude cell and yields parameters from which the energy spectrum of suprathermal electrons (equal to or greater than 5 eV) can be deduced. Our earliest measurements are used to illustrate applications of the coded long-pulse technique to several aeronomic/ionsospheric areas of current interest. These include studies of neutral wave motions in the lower thermosphere, measurements of ion composition in the F(sub 1) region/upper ionosphere, and investigations of electron-gas thermal balance and photoelectron energy loss processes. The technique can be utilized to examine irregularity formation in the F region, probe electron acceleration processes in ionospheric modification experiments, verify the magnetic field dependence of Langmuir wave damping, and more generally test higher order corrections suggested for the Langmuir dispersion relation. It is anticipated that the latter tests will facilitate measurements of ionospheric currents.
This is a continuation of studies using a two-pulsed technique for Ablative Laser Propulsion (ALP) extended to force measurements in vacuum. Aluminum samples were ablated using pairs of laser pulses, each of 100 ps width, 532 nm wavelength and 5 mJ energy. The pulses were temporally separated in the 0 - 0.67 ns range. The force imparted on Al targets was measured in situ by means of a piezoelectric force gauge. The preliminary results confirm the previously reported oscillatory behavior of ion velocity and number density observed by means of a time-of-flight energy analyzer. The uncertainties of presented measurements and future directions for the study are discussed.
Polycrystalline diamond films were deposited using a microwave plasma-enhanced chemical vapor deposition process. A laser pulse technique was developed to measure the thermal diffusivity of diamond films deposited on a silicon substrate. The effective thermal diffusivity of a diamond film on silicon was measured by observing the phase and amplitude of the cyclic thermal waves generated by laser pulses. An analytical model is presented to calculate the effective in-plane (face-parallel) diffusivity of a two-layer system. The model is used to reduce the effective thermal diffusivity of the diamonds/silicon sample to a value for the thermal diffusivity and conductivity of the diamond film. The average effective diffusivity values are 1.47 + or - 0.03 and 1.83 + or - 0.10 yielding thermal diffusivity values of 7.46 + or - 0.90 and 7.33 + or - 0.70 sq cm/s respectively, for the two samples; the calculated thermal con ductivity values are 13.50 and 13.28 W/cmK, which are better than that of type 1a natural diamond. The phase and amplitude measurements give similar results.
A case of flutter developed at a speed lower than had been flown previously. This incident precipitated the routine procedure of pulsing control surfaces as well as the firing of explosive charges during speed build-ups. In the interest of rapid evaluation of results, simple methods of data reduction were used. A case history is presented where in the pulse technique predicted flutter by extrapolating decay rates obtained at subcritical speeds; in addition, a case is presented where no valid extrapolation could be made.
Pulse compression has been widely used in radars so that low-power, long RF pulses can be transmitted, rather than a highpower short pulse. Pulse compression radars offer a number of advantages over high-power short pulsed radars, such as no need of high-power RF circuitry, no need of high-voltage electronics, compact size and light weight, better range resolution, and better reliability. However, range sidelobe associated with pulse compression has prevented the use of this technique on spaceborne radars since surface returns detected by range sidelobes may mask the returns from a nearby weak cloud or precipitation particles. Research on adaptive pulse compression was carried out utilizing a field-programmable gate array (FPGA) waveform generation board and a radar transceiver simulator. The results have shown significant improvements in pulse compression sidelobe performance. Microwave and millimeter-wave radars present many technological challenges for Earth and planetary science applications. The traditional tube-based radars use high-voltage power supply/modulators and high-power RF transmitters; therefore, these radars usually have large size, heavy weight, and reliability issues for space and airborne platforms. Pulse compression technology has provided a path toward meeting many of these radar challenges. Recent advances in digital waveform generation, digital receivers, and solid-state power amplifiers have opened a new era for applying pulse compression to the development of compact and high-performance airborne and spaceborne remote sensing radars. The primary objective of this innovative effort is to develop and test a new pulse compression technique to achieve ultrarange sidelobes so that this technique can be applied to spaceborne, airborne, and ground-based remote sensing radars to meet future science requirements. By using digital waveform generation, digital receiver, and solid-state power amplifier technologies, this improved pulse compression technique could bring significant impact on future radar development. The novel feature of this innovation is the non-linear FM (NLFM) waveform design. The traditional linear FM has the limit (-20 log BT -3 dB) for achieving ultra-low-range sidelobe in pulse compression. For this study, a different combination of 20- or 40-microsecond chirp pulse width and 2- or 4-MHz chirp bandwidth was used. These are typical operational parameters for airborne or spaceborne weather radars. The NLFM waveform design was then implemented on a FPGA board to generate a real chirp signal, which was then sent to the radar transceiver simulator. The final results have shown significant improvement on sidelobe performance compared to that obtained using a traditional linear FM chirp.
Sinusoidal pulse test method to account for variation of shock spectra with damping
Exploding Bridge Wire /EBW/ is treated as a transmission line system and pulse reflection techniques are used for checking the electrical integrity of an EBW cartridge. A step voltage is propagated into the system and the reflected voltage waves are monitored.
Electrolyte pulsing using carbon electrode for improved fuel cell operation
Heavy discharge pulsing to improve fuel cell electrode performance
A novel method for testing electroexplosive devices is proposed wherein capacitor discharge pulses, with increasing energy in a step-wise fashion, are delivered to the device under test. The size of the energy increment can be programmed so that firing takes place after many, or after only a few, steps. The testing cycle is automatically terminated upon firing. An energy-firing contour relating the energy required to the programmed step size describes the single-pulse firing energy and the possible sensitization or desensitization of the explosive device.
Improvement of fuel cell electrode performance - effect of heavy discharge pulses on catalyst reactivation
The present invention relates to a method of measuring the temperature of the P-N junction within the light-emitting region of a quasi-continuous-wave or pulsed semiconductor laser diode device. A series of relatively short and low current monitor pulses are applied to the laser diode in the period between the main drive current pulses necessary to cause the semiconductor to lase. At the sufficiently low current level of the monitor pulses, the laser diode device does not lase and behaves similar to an electronic diode. The voltage across the laser diode resulting from each of these low current monitor pulses is measured with a high degree of precision. The junction temperature is then determined from the measured junction voltage using their known linear relationship.
For the Skylab S-193 radar altimeter, data processing flow charts and identification of calibration requirements and problem areas for defined S-193 altimeter experiments are presented. An analysis and simulation of the relationship between one particular S-193 measurement and the parameter of interest for determining the sea surface scattering cross-section are considered. For the GEOS-C radar altimeter, results are presented for system analyses pertaining to signal-to-noise ratio, pulse compression threshold behavior, altimeter measurement variance characteristics, desirability of onboard averaging, tracker bandwidth considerations, and statistical character of the altimeter data in relation to harmonic analysis properties of the geodetic signal.
Mode of operation for radar ranging system based on ringing frequencies is described. Methods for measuring range and range rate are discussed. Mathematical model is included to describe ringing frequency. Application to acoustic sounding devices is proposed.