Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Novel Approach to PV Inverter Modeling and Simulation Leveraging Experiments, Learning Based Modeling and Co-Simulation: Preprint

Photovoltaic inverter (PV) inverter manufacturers use custom, proprietary control approaches and topologies in their inverter design. Due to this proprietary nature, it is not possible to share EMT domain models for system studies. This research work presents a novel approach in experimental design, high fidelity data collection, use of learning-based modeling, and co-simulation to enhance the PV inverter modeling. We used a 20 kW off-the-shelf grid following PV inverter and subjected the inverter to controlled tests including voltage and frequency step changes, as well as solar irradiance variations. The recorded high frequency data was used in learning-based model training. This learning-based model was imported into an Electromagnetic Transient (EMT) simulation tool using co-simulation techniques to complete the modeling effort and integrate the model into an EMT simulation tool. The three key components in this research work are the design of experimental setup, use of learning-based approach for model development and use of co-simulation to complete the approach. The proposed approach will allow users to develop a model in a really short period of time and achieve reasonable inverter models.

artificial intelligence↗

Accelerating Simulation for High-Fidelity PV Inverter System Reliability Assessment with High-Performance Computing

The overall cost of photovoltaic (PV) systems has shown a downward trend during the last decade; however, PV inverter failures account for the highest cost of operation and maintenance. To address this, reliability tools with powerful computation and better accuracy are required for the lifetime prediction and degradation evaluation of PV inverters. This paper proposes an event-driven parallel computing-based simulator. The proposed simulator applies high-performance computing techniques and other accessory optimization techniques-including cluster merging, adaptive model updates, and steady-state identification-to make reliability assessments for PV inverters under given input mission profiles and operating conditions with high efficiency and high fidelity. The main idea of the simulator and its workflow are introduced. Then, a demo PV inverter system simulator is implemented, and the speedup of the total simulations of the switching model reaches 123.03 times.

high-performance computing↗

PV Inverter Fault Response Including Momentary Cessation, Frequency-Watt, and Virtual Inertia

This paper presents two photovoltaic (PV) inverter control methods and an analysis of the two under a significant three-phase transmission line fault contingencies in the Hawaiian island of Oahu power system. Simulations are presented for the two control methods on the island power system with a high penetration of PV generation, approximately 40% of the total. The two control methods discussed are similar: one is a proportional frequency-watt controller, and the second is a proportional-derivative controller, a frequency-watt controller with virtual inertia. Both methods can be beneficial for fast frequency support. The inverter model also emulates inverter fault response including 'momentary cessation' and recovery during low voltage events. The study presented in this paper utilizes a validated power system model of the Hawaiian island of Oahu, modified to include PV resources with the two custom developed control models. Dynamic simulations with PSS/E are presented during a significant transmission line three-phase fault contingency. Simulations are presented with and without PV reserve margin. In addition, a parameter sensitivity analysis is presented for the control methods. Results indicate both methods can significantly improve system response during fault events. Findings indicate that transmission faults can produce severe frequency events, and that fast recovery from momentary cessation is crucial to mitigate severity.

14 SOLAR ENERGY↗

IEEE 1547-2018 Based Interoperable PV Inverter with Advanced Grid-Support Functions

Grid integration of photovoltaic (PV) inverters has been increasing in the past decade. As a result of the uncertainties introduced with high penetrations of PV, better monitoring and control of the PV inverters becomes crucial for improving overall system stability. This paper focuses on the communications capability of the inverter controller and on enabling interoperability. Multiple standards are available to enable interoperability in PV inverters. In this paper, an interoperable controller, enabled by Distributed Network Protocol 3 (DNP3) communications protocols, is developed for a grid-connected, three-phase PV inverter. The DNP3 server for the PV inverter is programmed on the real-time layer of the field-programmable gate array (FPGA)-based inverter controller. Set points for advanced inverter control functions, such as volt/VAr curves, ride-through curves, are sent from a DNP3 client, a simulated distribution management system application, to the PV inverter through DNP3. This communications capability of the inverter controller is validated using a controller-hardware-in-the-loop experimental setup. The code developed to achieve the interoperability is available in the public domain through open-source software licensing. This interoperability will enable smoother grid integration of smart PV inverters with advanced grid-support functions as well as allow better monitoring and control of PV inverters for grid stability.

14 SOLAR ENERGY↗

Lightweight PV Inverters: Dual Bi-Directional IGBTs Modules Enables Breakthrough PV Inverter Using Current Modulation Topology

Solar ADEPT Project: PV inverters convert DC power generated by modules into usable AC power. IPC’s initial 30kW 94lb. PV inverter reduces the weight of comparable 30kW PV inverters by 90%—reducing the cost of materials, manufacturing, shipping, and installation. With ARPA-E support, new bi-directional silicon power switches will be developed, commercialized, and utilized in IPC’s next-generation PV inverter. With these components, IPC will produce 100kW inverters that weight less than 100lb., reducing the weight of conventional 3,000lb. 100kW inverters by more than 95%. The new power switches will cut IPC’s $/W manufacturing cost in half, as well as further reduce indirect shipping and installation costs.

ARPA-E↗

Experimental Determination of PV Inverter Response to Grid Phase Shift Events: Preprint

With the continued growth of renewable energy resources which interface to the electric grid via inverters, the understanding of such devices becomes ever more important to the safe and reliable operation of the bulk power system. This work investigates the specific response of a utility-scale PV inverter to grid voltage phase shift-type disturbances which sometimes occur during grid fault events. The role of the PV inverter's phase-locked-loop (PLL) is identified as important to modeling the response. Switching-level simulations of a utility-scale PV inverter with a modeled PLL show a characteristic response when phase shift disturbances require the PLL to track what appear as fast frequency changes. Additionally, in this work a full-scale laboratory testing was carried out using the Opal real time (RT) OP5142 real time simulator and a large grid simulator to create phase shift disturbances with a high degree of repeatability. A photovoltaic (PV) inverter was connected to a grid simulator, and phase shifts were instantaneously implemented on the simulated grid, the results of the currents were then obtained. The experimental results obtained were validated with simulation results obtained from MATLAB/Simulink.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing PV Inverter Reliability Through Predictive Maintenance: Insights from Retrofitting of PV Inverters

Photovoltaic (PV) systems represent a cornerstone in the global shift toward sustainable energy generation, with inverters serving as the crucial link between solar panels and the grid. Despite their pivotal role, inverters are susceptible to failures, contributing significantly to maintenance events and operational disruptions in large-scale PV plants. This white paper investigates the importance and methodologies of predictive maintenance strategies that monitor the component-level pre-failure signatures on PV inverters. Through a comprehensive survey of literature and industry professionals, insights on preventive maintenance and retrofitting practices have been gathered. The expert elicitation helps shed light on common challenges and opportunities for improving PV system reliability, particularly inverter reliability. By addressing these challenges, the white paper aims to enhance the long-term viability and effectiveness of solar PV plants in the renewable energy landscape, contributing to the global transition toward environmentally friendly energy generation.

14 SOLAR ENERGY↗

Power Hardware-in-the-Loop Evaluation of PV Inverter Grid Support on Hawaiian Electric Feeders

As more grid-connected photovoltaic (PV) inverters become compliant with evolving interconnections requirements, there is increased interest from utilities in understanding how to best deploy advanced grid-support functions (GSF) in the field. One efficient and cost-effective method to examine such deployment options is to leverage power hardware-in-the-loop (PHIL) testing methods, which combine the fidelity of hardware tests with the flexibility of computer simulation. This paper summarizes a study wherein two Hawaiian Electric feeder models were converted to real-time models using an OPAL-RT real-time digital testing platform, and integrated with models of GSF capable PV inverters based on characterization test data. The integrated model was subsequently used in PHIL testing to evaluate the effects of different fixed power factor and volt-watt control settings on voltage regulation of the selected feeders using physical inverters. Selected results are presented in this paper, and complete results of this study were provided as inputs for field deployment and technical interconnection requirements for grid-connected PV inverters on the Hawaiian Islands.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Evaluation of Grid Support Enabled PV Inverter Response to Abnormal Grid Conditions

As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and voltage/frequency ride-through, among others. This paper describes the results of a comparative experimental evaluation on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and its effect on abnormal grid condition response. The evaluation examined the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. Testing results indicated a wide variance in the performance of GSF enabled inverters to various test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Validation of a SiC Based 50 kW Grid-Connected PV Inverter: Preprint

In this digest a 50kW string PV inverter formed using all SiC semiconductor devices is presented. The inverter design includes additively manufactured power block, symmetrical Y-core inductors for ac side filter, and advanced inverter functionality for grid support. This inverter utilizes the conventional three-phase Voltage Source Inverter topology and optimizes the design for SiC based devices. This paper presents the full functional validation of the designed inverter along with quantification of the efficiency and power density. The performance of the inverter for high dc-bus voltage without multi-level topology to exploit SiC advantages is also presented in this digest. The full paper will include details of inverter design, optimization and further experimental validation.

14 SOLAR ENERGY↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

artificial intelligence↗

Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems

Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. This paper proposes a holistic impulse-based MOV lifetime estimation framework. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.

lifetime estimation↗

Performance and Techno-Economic Evaluation of a Three-Phase, 50-kW SiC-Based PV Inverter

The technical capabilities and benefits of silicon carbide (SiC) compared to silicon (Si) based power electronics converters as well as the premium associated with using SiC instead of Si are well understood. This work proves that the benefits provided by SiC, such as increased efficiency, would result in a lower levelized cost of energy (LCOE) compared to both commercially available, state-of-the-art inverters and the benchmark commercial system cost calculated for the U.S. Department of Energy Solar Energy Technologies Office's SunShot program. The LCOE is calculated to be same as the commercial benchmark despite the installed system cost being 8% more than the benchmark. The LCOE calculation is based on both experiential values obtained from testing the SiC photovoltaic (PV) inverter and on the bottoms-up modeled volume cost for the same 50-kW SiC-based inverter. The PV system used for the LCOE model is also explained, and the system cost breakout is presented in this paper. Furthermore, multiple scenarios with variations in the PV system are presented to show their effect on the system LCOE.

14 SOLAR ENERGY↗

Fast Quasi-Static Time-Series Simulation for Accurate PV Inverter Semiconductor Fatigue Analysis with a Long-Term Solar Profile

Power system simulations with long-term data typically have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stress cycle occurs over the fundamental grid frequency (50 or 60 Hz). This requires the time step of the fatigue simulation to be around 100 µs. This small time step requires long computation times to process yearly power production profiles. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The proposed simulation calculates the steady state of the semiconductor junction temperature by using a Fast Fourier Transform (FFT). The small thermal cycling during a switching period and even over the fundamental waveform is disregarded to further accelerate the simulation speed. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset. The error of the proposed simulation is 0.16% compared to the fatigue simulation results using the complete thermal stress profile. A PV inverter that responds to a Transactive Energy System (TES) is simulated to demonstrate the use of the proposed fatigue simulation. The proposed simulation has the potential to co-simulate with system level simulation tools that also adopt the QSTS concept.

Liu, Yunting↗

GaN‐based split phase transformer‐less PV inverter with auxiliary ZVT circuit

This paper explores performance enhancement of the common ground dynamic dc‐link (CGDL) inverter for single phase photovoltaic (PV) applications by a combination of gallium nitride (GaN) devices, split phase topology, coupled inductors, and zero voltage transition (ZVT) scheme. The CGDL inverter has the inherent advantage of minimised dc‐link capacitance and negligible leakage current due to the common ground configuration, but its reported efficiency was usually lower because of the higher dc‐link voltage used for the reduction of decoupling capacitance to a great extent. To solve the efficiency problem, in this study, a soft switching circuit is proposed for the first stage, while a coupled inductor integrated magnetics is incorporated in the second stage to reduce inductor loss, volume, and cost. Both of these topological improvements combined with the use of GaN devices facilitate in achieving high efficiency without compromising converter power density. Extensive experimental results are provided from a GaN based 1 kVA hardware prototype to demonstrate the superior performance of the CGDL inverter attaining a peak efficiency of 98.7% and a California Energy Commission efficiency of 98.5% at 75/50 kHz switching frequency.

Xia, Yinglai↗

Controller-Hardware-in-the-Loop Test Bed for Fast-Switching SiC-Based 50-kW PV Inverter

The recent advent of wideband gap power semiconductor devices will lay the path to the future power converters. These devices provide the advantage of high switching speed and lower losses. The high cost and high switching speeds of these devices provide a challenge in the development and validation of the fast switching inverter controls with accuracy of that of a hardware setup. In this paper an FPGA real-time simulator-based controller-hardware-in-the-loop (CHIL) testbed is used to verify the low-level and advanced inverter controls fast switching wide bandgap-based string photovoltaic inverter. The paper also includes development of the CHIL testbed, which is run at a time-step of 500 ns in order to implement 20 kHz switching frequency. The developed CHIL testbed is validated through experimental results from a three-phase, 50 kW, 480 VLLrms SiC devices based inverter.

14 SOLAR ENERGY↗

Modeling of Marginal Cost for PV Inverter Ancillary Services Considering Inverter Aging under Transactive Energy Framework

PV inverters can provide ancillary services while providing active power. Transactive energy system (TES) incentivizes PV inverter to provide ancillary services and compensates for the cost of additional power losses due to additional reactive power production. However, providing ancillary services can shorten the lifetime of the PV inverter since additional reactive power increases the thermal stress of the PV inverter. This paper theoretically derives the lifetime shortening effect of a PV inverter when providing ancillary services. Based on the lifetime estimation, an improved marginal cost curve for the PV inverter ancillary services is derived. The improved marginal cost quantitively describe the willingness of the PV inverter to provide ancillary services by the given active power production and the ambient temperature. The proposed model is validated by a simulation case study.

Liu, Yunting↗