Agrivoltaic Racking Design Optimization Based on Wind and Snow Loading Finite Element Analysis

The racking structure of photovoltaic (PV) systems plays a critical role in ensuring the PV panels generate power properly as it provides integral structural support and sometimes even solar tracking ability. Distinct applications of PV systems require variations of racking structure designs, which yield different mechanical performances under external loading conditions from the environment, such as heavy wind and snow. Past works, such as Reddy et al. [1], have analyzed the pressure effects of wind and snow loading on the racking structure of conventional rooftop and utility PV systems, but there is little knowledge of how various agrivoltaic racking systems perform, in terms of stress and strain, under the same loading conditions. There is also a knowledge gap in the industry on a set of optimized agrivoltaic racking design standards. This study investigates the mechanical performance of various existing racking systems and proposes novel designs that are optimized for agrivoltaics applications under wind and snow loading.

Liao, Quanhuan

Technoeconomic Analysis (TEA)

Techno-economic analysis (TEA) for the DuraMAT Consortium includes the following areas: linking solar photovoltaic (PV) technology trends to reliability implications; providing a framework to calculate technology costs, yielding insights useful for research decision-making, proposals, technology selection, and publications; and examining technology tradeoffs considering lifecycle project economics. This poster highlights results from the first and second iterations of the DuraMAT Technology Scouting reports as well as the updated Simplified PV Levelized Cost of Energy (LCOE) Calculator.

14 SOLAR ENERGY

Maturing Rational Design Methodologies and Industry Consensus Engineering Standards: Critical Fastened Joints - Solar PV Industry

Critical structural joints can be seen throughout a solar array and are called upon to secure modules and keep racking assembled and able to resist large demands from winds and snow loads. In the relatively new and fast-growing solar PV industry, the important role these hardware assemblies (e.g. clips, clamps, bolts, nuts, washers) play is not well understood by product designers. Failures with critical structural joints are surprisingly common and point to the need for maturing the engineering and assembly of these joints. The wide variety of design concepts (Figure 2&2) demonstrate interesting and innovative ideas but are lacking the basics of fastener engineering seen in matured industries (e.g. transportation, buildings). Complicating the maturing process for critical structural joints is that they are one component in rack supporting structures that exhibits a systems behavior; each component will affect the other and play a key role in maintaining structural integrity. When wind loads the surface of a module, the underlying racking members deflect and twist which in turn imparts forces back into the joints and into the mounted modules. Often, these supporting rack structures exhibit high deflections and low natural frequencies which amplify the demands placed into the joints even in moderate winds. Current engineering practices and associated structural conventions view solar racking support structures as they would a high mass building that exhibit more static behaviors in wind events. Solar structures are unique from high mass buildings and require the development of solar specific industry engineering consensus standards.

14 SOLAR ENERGY

InGaAs PV device development for TPV power systems

Indium gallium arsenide (InGaAs) photovoltaic devices have been fabricated with bandgaps ranging from 0.75 eV to 0.60 on Indium phosphide (InP) substrates. Reported efficiencies have been as high as 11.2 percent (AMO) for the lattice matched 0.75 eV devices. The 0.75 eV cell demonstrated 14.8 percent efficiency under a 1500 K blackbody with a projected efficiency of 29.3 percent. The lattice mismatched devices (0.66 and 0.60 eV) demonstrated measured efficiencies of 8 percent and 6 percent respectively under similar conditions. Low long wavelength response and high rack currents are responsible for the poor performance of the mismatched devices. Temperature coefficients have been measured and are presented for all of the bandgaps tested.

Wilt, David M.

Novel PV Array System Design to Accelerate Solar Deployment, Reduce LCOE, Reduce Land Use Competition, and Increase Siting Flexibility

The increasing demand for solar energy faces significant barriers, including inefficient construction processes, high project costs limiting LCOE reductions, and diminishing availability of "good" sites with favorable interconnection. Conventional solar installations are often constrained by long construction timelines and the need for flat, large plots. Furthermore, the industry struggles with a shortage of skilled labor. Planted Solar aims to address these challenges by fundamentally transforming solar deployment from a construction project into a streamlined manufacturing process. Our novel approach combines high-density racking, integrated terrain-following design software, and installation automation. Unlike competing solutions that either assist with standard array assembly or offer dense packing without terrain adaptability or automation, Planted's technology uniquely brings together a new array product with in-place automated manufacturing to achieve the lowest possible cost, greater site flexibility, and accelerated deployment.

14 SOLAR ENERGY

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY

Close roof-mounted system temperature estimation for compliance to IEC TS 63126

When photovoltaic (PV) modules are installed on rooftops, the module temperature depends primarily on the geographic location and the mounting configuration. If the mounting structure does not provide sufficient airflow in a hot environment, the 98th percentile temperature will exceed 70°C, which according to IEC TS 63126 ED. 1, requires higher levels of thermal stability testing. However, there is no clear way to determine the temperature level needed for a particular location and system design. Here, in this work, we identify a relationship between the module standoff to the rooftop and the module temperature and propose methods to describe a minimum standoff for typical PV modules in a simple mounting configuration installed in a given location. For more complex system designs, we show how to determine an equivalent “effective standoff” that can be applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.