Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV smoothing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Solar +: Clean Energy Strategies for the Sunshine State (Final Technical Report (FTR) of the Florida Alliance for Accelerating Solar and Storage Technology Readiness (FAASSTeR))

This reports on a four-year effort to provide foundational research, analysis, strategies and assistance to help Florida, and other states that might learn from this work, to grow solar energy in conjunction with other distributed energy resources by addressing and overcoming existing barriers, and in way that delivers increased value. The start of this effort coincided with an inflection point of sorts into a new dawn for solar energy in Florida, where the Sunshine state’s national ranking in total installed solar, according to the Solar Energy Industries Association (SEIA), has rose from 13th to 4th. Florida has now become the national leader in annual utility-scale solar growth as dozens of large plants have come online. Also, during this time, Florida utilities have expressed a strong and growing interest in understanding the role of energy storage and how to best plan for and deploy this unique resource as part of strategies to grow solar. The utility-scale solar growth experienced has been fueled by the economics of solar cost-parity with natural gas combined cycle plants and Florida Public Service Commission’s (PSC) approval of cost-recovery for the Investor-Owned Utilities (IOU’s), primarily through the Solar Base Rate Adjustment (SoBRA) mechanism. This has led to gigawatts (GW’s) of rate-based solar capacity additions over several years, along with fairly significant amounts of energy storage. Meanwhile, municipal electric utilities, which, collectively, are the third largest source of power in the state, have been increasing solar considerably through power purchase agreements (PPA’s) and are on track to have close to 1 GW of grid-connected solar by 2024. Florida’s municipal utilities and the Florida Municipal Electric Association (FMEA) have been key partners in the Florida Alliance for Accelerating Solar and Storage Technology Readiness (FAASSTeR), formed to carry out this effort. The six largest of these have been Core Team utilities, engaging throughout the project in weekly calls, discussions, and project direction, participating in and hosting workshops and benefiting from technical assistance in several areas.

14 SOLAR ENERGY↗

Development Support for NREL's System Advisor Model (SAM): Cooperative Research and Development, CRADA Number CRD-20-16998 (Final Report)

The variable nature of renewable generation, which depends on the sun shining and wind blowing for example, presents challenges for adequate and least-cost resource planning. The deployment of renewable generation assets is anticipated to increase due to various drivers, such as declining costs, favorable government policies, and increasing procurement by corporations and consumers. High levels of renewable penetration are anticipated to pose flexibility, reliability, and cost challenges to the electrical system. The development and implementation of new features into performance modeling software, such as the National Renewable Energy Laboratory's (NREL) System Advisor Model (SAM), is one way to help think through these challenges and develop appropriate strategies.

14 SOLAR ENERGY↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Dynamical Model for The Jupiter Thermocline

A new conceptual model for the observed banded wind structure of the giant outer planets is proposed, assuming a smoothly distributed potential vorticity (PV) atop a layer of deeply seated, latitudinally variable stratification. With a vanishing horizontal entropy contrast presumably enforced at the bottom of the flow layer by the underlying convection, the thermal-wind balance of observed cloud-top motions implies a mapping of constant potential temperature surfaces, nearly vertical at upper tropospheric levels, down to a deeper, flatter, but variably sloped 'thermocline.' For a generally colder-poleward distribution of isentropes consistent with the strong equatorial jets of both Jupiter and Saturn, this kind of mapping would also imply a poleward decreasing static stability. The proposed temperature-stability distribution is just the reverse of the Earth's troposphere, where the strongest latitudinal potential temperature gradients are at the bottom instead of the top, with static stability generally increasing toward the pole. The warmer-stabler correlation for Jupiter would be consistent, however, with a nearly monotonic distribution of PV from low to high latitudes, over planetary scales for which the planetary vorticity dominates the relative vorticity of the jets. In this way efficient PV mixing for the isentropically bounded thermocline can account for the dynamical maintenance of the cyclonic flanks of the equatorial jet. Over latitudinal intervals comparable to the internal deformation scale, however, the gradient of the absolute vorticity is dominated by the flow curvature, with the local latitudinal gradient of the static stability proportional to the local potential temperature gradient and therefore the local variation in geostrophic velocity. The resulting correlation of velocities and vorticity gradients implies an alternation of the flow over the internal deformation radius set by the vertical entropy contrast.

Allison, Michael↗

Recent Improvements in PV+Battery Modeling in NREL's System Advisor Model

This poster covers recent updates to the NREL System Advisor Model's battery model that can be coupled to the PV model to add value to both front of meter and behind the meter systems. Topics include new dispatch algorithms focusing on smoothing the output of a PV plant to meet ramp rate requirements and responding to price signals to maximize system revenue, validated battery lifetime models, grid outage simulations and resiliency metrics, and the new levelized cost of storage (LCOS) metric. We will also share preliminary results from NREL analysis projects using these features.

battery↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Cooperative fault management for resilient integration of renewable energy

Cooperative fault management (CFM) is designed herein to control different types of renewable energy resources cooperatively during electrical faults. This paper studies systems with a high penetration of photovoltaic (PV) energy and wind energy. First, CFM leverages power converters of PV farms to boost the ride-through capability of nearby doubly-fed induction generators (DFIGs). By controlling PV farms’ output voltages to change smoothly during both fault initiation and fault clearance, the widely used crowbar in DFIGs is less likely to be activated. Crowbar activation adversely makes DFIGs lose controllability and absorb reactive power. The second contribution is the development of a software-defined CFM controller and a controller in-the-loop demonstration of the real-time performance of this optimization-based CFM. CFM capitalizes on distributed optimization formulation to enable flexibility, plug-and-play, and privacy-preserving. Computation time, however, is a major concern for optimization-based dynamics control. Here, real-time controller-in-the-loop simulation results show optimization-based CFM can output reference values around 60 ms and is quick enough for dynamic control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Phasor-Based Control for Scalable Solar PV Integration

This project demonstrated that solar PV can be recruited to stabilize the grid, smooth out disturbances, manage power flows, and assist circuit switching operations. It developed a radically new, layered control framework for Distributed Energy Resources (DER) to act in response to real-time, measured conditions on their local distribution circuit, rather than waiting for a price signal to indicate preferred behavior. By enabling resources to act as good citizens on the electric grid, Phasor-Based Control (PBC) facilitates arbitrarily high solar penetration levels.

14 SOLAR ENERGY↗

Phasor-Based Control for Scalable Solar PV Integration (Final Technical Report)

This project demonstrated that solar PV can be recruited to stabilize the grid, smooth out disturbances, manage power flows, and assist circuit switching operations. It developed a radically new, layered control framework for Distributed Energy Resources (DER) to act in response to real-time, measured conditions on their local distribution circuit, rather than waiting for a price signal to indicate preferred behavior. By enabling resources to act as good citizens on the electric grid, Phasor-Based Control (PBC) facilitates arbitrarily high solar penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Sparse and Low Rank Penalized Signal Decomposition Model with Constraints: Anomaly Detection in PV Systems

Recently, robust PCA has seen its wide application in various industries for its ability to perform the task of anomaly detection. The essence of robust PCA approach is to break down the signal into a low rank component and sparse component. In many applications, a simple breakdown of the signal without accounting for the signs of low rank components and sparse components would violate the physical constraints of the decomposed signal. In addition, often times, the signals in the real world collected for a long duration has smooth changes within a day and between days. As an example, the power signals collected in a photovoltaic (PV) system are cyclostationary, exhibiting these characteristics. Neglecting the smoothness of signals would result in miss detection of anomalous signals which are smooth within a day but non-smooth between days and vice versa. In this paper, we developed a signal decomposition approach for the purpose of anomaly detection based on the idea of low rank and sparse decomposition taking into consideration the signs of the decomposed low rank and sparse components and the within-day and between-day smooth changes in the original signals. The proposed unsupervised approach for fault detection eliminates the need for faulty samples required by other machine learning methods. It does not require the full I-V characteristics to work. Furthermore, there is no need for complex modelling of PV systems as in the case of power loss analysis. Using Monte Carlo simulations, we demonstrate the ability of our proposed approach for detecting anomalies of different duration and severity in PV systems.

14 SOLAR ENERGY↗

Using spatio-temporal graph neural networks to estimate fleet-wide photovoltaic performance degradation patterns

Accurate estimation of photovoltaic (PV) system performance is crucial for determining its feasibility as a power generation technology and financial asset. PV-based energy solutions offer a viable alternative to traditional energy resources due to their superior Levelized Cost of Energy (LCOE). A significant challenge in assessing the LCOE of PV systems lies in understanding the Performance Loss Rate (PLR) for large fleets of PV systems. Estimating the PLR of PV systems becomes increasingly important in the rapidly growing PV industry. Precise PLR estimation benefits PV users by providing real-time monitoring of PV module performance, while explainable PLR estimation assists PV manufacturers in studying and enhancing the performance of their products. However, traditional PLR estimation methods based on statistical models have notable drawbacks. Firstly, they require user knowledge and decision-making. Secondly, they fail to leverage spatial coherence for fleet-level analysis. Additionally, these methods inherently assume the linearity of degradation, which is not representative of real world degradation. To overcome these challenges, we propose a novel graph deep learning-based decomposition method called the Spatio-Temporal Graph Neural Network for fleet-level PLR estimation (PV-stGNN-PLR). PV-stGNN-PLR decomposes the power timeseries data into aging and fluctuation components, utilizing the aging component to estimate PLR. PV-stGNN-PLR exploits spatial and temporal coherence to derive PLR estimation for all systems in a fleet and imposes flatness and smoothness regularization in loss function to ensure the successful disentanglement between aging and fluctuation. We have evaluated PV-stGNN-PLR on three simulated PV datasets consisting of 100 inverters from 5 sites. Experimental results show that PV-stGNN-PLR obtains a reduction of 33.9% and 35.1% on average in Mean Absolute Percent Error (MAPE) and Euclidean Distance (ED) in PLR degradation pattern estimation compared to the state-of-the-art PLR estimation methods.

14 SOLAR ENERGY↗

Providencia Island White Papers: Hawaii, USA: A Grid Planning Case Study for Providencia Island, Colombia

Special considerations exist for island grids seeking to smoothly integrate distributed energy resources (DERs), such as rooftop photovoltaics (PV), with an existing fossil fuel-based grid without compromising system stability and reliability. Hawaii, having successfully integrated nonconventional renewable energy sources for a hybrid electricity grid, may serve as a guide for technical specifications and interconnection policy. Island grid planners may seek to follow Hawaii's example by standardizing technical specifications of generators, particularly for advanced inverter components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The evolution of AAOE observed constituents with the polar vortex

One of the difficulties in determining constituent trends from the ER-2 flight data is the large amount of day to day variability generated by the motion of the polar vortex. To reduce this variability, the observations have been transformed into the conservative (Lagrangian) reference frames consisting of the coordinate pairs, potential temperature (PT) and potential vorticity (PV), or PT and N2O. The requirement of only two independent coordinates rests on the assumption that constituent distributions and their chemical processes are nearly zonal in that coordinate system. Flight data is used everywhere for these transformation except for potential vorticity. Potential vorticity is determined from level flight segments, and NMC PV values during flight dives and takeoffs are combined with flight data in a smooth fashion.

Schoeberl, Mark R.↗

Anomaly detection in PV systems using constrained low-rank and sparse decomposition

PV (photovoltaic) systems, also known as solar panel systems, play an essential role in the mitigation of greenhouse gas emissions and the promotion of renewable energy. Through the conversion of sunlight into usable energy, electricity is generated without emitting greenhouse gases and producing pollutants. Notwithstanding the evolutionary significance of PV systems, the occurrence of defects and anomalies in PV systems may result in diminished power output, consequently impeding the efficiency of the systems and potentially resulting in hazards in certain circumstances. Therefore, early detection of faults and anomalies in PV systems is imperative to guarantee the reliability, efficiency, and safety of the systems. In this article, we develop a signal decomposition for the purpose of anomaly detection in PV systems. The proposed methodology is grounded on the concept of low-rank and sparse decomposition, with consideration given to the signs of the decomposed low-rank and sparse components, as well as the smooth variations within and between periods in the mean signals. Through the implementation of Monte Carlo simulations, we showcase the efficacy of our proposed methodology in identifying anomalies of varying durations and magnitudes in PV systems. A case study is employed to validate the proposed methodology in detecting anomalies in real PV systems.

14 SOLAR ENERGY↗

Transient Weighted Moving-Average Model of Photovoltaic Module Back-Surface Temperature

Accurate modeling of photovoltaic (PV) performance requires the precise calculation of module temperature. Currently, most temperature models rely on steady-state assumptions that do not account for the transient climatic conditions and thermal mass of the module. On the other hand, complex physics-based transient models are computationally expensive and difficult to parameterize. In order to address this, a new approach to transient thermal modeling was developed, in which the steady-state predictions from previous timesteps are weighted and averaged to accurately predict the module temperature at finer time scales. This model is informed by 3-D finite-element analyses, which are used to calculate the effect of wind speed and module unit mass on module temperature. The model, in application, serves as an added filter over existing steady-state models that smooths out erroneous values that are a result of intermittency in solar resource. Validation of this moving-average model has shown that it can improve the overall PV energy performance model accuracy by as much as 0.58% over steady-state models based on mean absolute error improvements and can significantly reduce the variability between the model predictions and measured temperature times series data.

14 SOLAR ENERGY↗

Solar Transposition Modeling via Deep Neural Networks With Sky Images

This article presents a notable advance toward the development of a new method of increasing the single-axis tracking photovoltaic (PV) system power output by improving the determination and near-term prediction of the optimum module tilt angle. The tilt angle of the plane receiving the greatest total irradiance changes with Sun position and atmospheric conditions including cloud formation and movement, aerosols, and particulate loading, as well as varying albedo within a module's field of view. In this article, we present a multi-input convolutional neural network that can create a profile of plane-of-array irradiance versus surface tilt angle over a full 180° arc from horizon to horizon. As input, the neural network uses the calculated solar position and clear-sky irradiance values, along with sky images. The target irradiance values are provided by the multiplanar irradiance sensor (MPIS). In order to account for varying irradiance conditions, the MPIS signal is normalized by the theoretical clear-sky global horizontal irradiance. Using this information, the neural network outputs an N -dimensional vector, where N is the number of points to approximate the MPIS curve via Fourier resampling. The output vector of the model is smoothed with a Gaussian kernel to account for error in the downsamping and subsequent upsampling steps, as well as to smooth the unconstrained output of the model. Furthermore, these profiles may be used to perform near-term prediction of angular irradiance, which can then inform the movement of a PV tracker.

42 ENGINEERING↗

Comparative and Cost Analysis of a Novel Predictive Power Ramp Rate Control Method: A Case Study in a PV Power Plant in Puerto Rico

One of the most important aspects that need to be addressed to increase solar energy penetration is the power ramp-rate control. In weak grids such as the one found in Puerto Rico, it is important to smooth power fluctuations caused by the intermittence of passing clouds. In this work, a novel power ramp-rate control strategy is proposed. Additionally, a comparison with some of the most common power ramp-rate control methods is performed using a proposed model and real solar radiation data from the Coto Laurel photovoltaic power plant located in Ponce, Puerto Rico. The proposed model was validated using one-year real data from Coto Laurel. The power ramp-rate control methods were compared in real-time simulations using the OP5700 from Opal-RT Technologies considering power ramp rate fluctuations, power ramp-rate violations, fluctuations in the state-of-charge, among other indicators. Moreover, the proposed power ramp-rate control strategy, called predictive dynamic smoothing was explained and compared. Results indicate that the predictive dynamic smoothing produced a considerably reduced Levelized Cost of Storage compared to other power ramp-rate control methods and provided a higher lifetime expectancy for lithium batteries.

36 MATERIALS SCIENCE↗

Characterization of Venera 15/16 Geologic Units from Pioneer Venus Reflectivity and Roughness Data

Geologic units have been defined for the surface of Venus from Venera 15/16 image data. A characterization of these geologic units is carried out using information on surface properties derived from Pioneer Venus (PV) reflectivity and rms slope data. The geologic context provided by Venera 15/16 units allows additional, more specific interpretations of surface radar properties to be made. Characterization of Venera units results in the definition of four groups of Venera units: (1) smooth rocky units, 2) rough rocky units, (3) rough high dielectric units, and (4) diffusely scattering units. On the basis of correlations of surface morphology to spatial and statistical distributions in rms slope and reflectivity data, we test models for the origin of the surface properties of some units. We conclude that plains and tectonic units can be contrasted in terms of the average roughness of the surface and that tectonic deformation appears to roughen the surface at 0.5- to 10-m and 5- to 50-cm scales. This tectonic weathering process appears to dominate the erosional regime of Venus. Unlike Earth or Mars, production and transport of soils dominates only a small portion (less than or equal to 5%) of the surface. Some of the Venera units display distinctive spatial and statistical distributions of PV radar data. In particular, apparent low reflectivity in the tesserae appears to be caused by small (5-50 cm) rock fragments on the surface which cause diffuse scattering at Pioneer Venus wavelengths. Analysis of models for the formation of these fragments suggests that they are due to the pervasive deformation undergone by the tesserae. Finally, aspects of this study have been used to extend results of Venera image data analysis southward of 30 deg. N lat, resulting in it prediction of the distribution of tessera. Such results can aid in Magellan investigations.

Bindschadler, D. L.↗