Search NASA⌕ Search

SEARCH · Search NASA

Results for “Parametric Capability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Description and Use of SCALE Sampler Parametric Capability for Engineering Analysis and Optimization

The Sampler sequence was introduced into the SCALE nuclear modeling and simulation suite in SCALE 6.2 to perform uncertainty quantification via random sampling of nuclear data, material number densities, and dimensions. Sampler was expanded with the introduction of a parametric capability in SCALE 6.2.2. This paper discusses input for the Sampler parametric sequence and presents two case studies of analyses performed using the sequence. These case studies include preconceptual design of a package for transporting high assay low-enriched uranium (HALEU) oxide and scoping calculations to support subcritical limit development for a future update of the ANSI/ANS-8.1 (ANS-8.1) standard. The parametric capability within Sampler provides many benefits to analysts. For instance, parametric sweeps are frequently used to identify optimum parameter values as part of safety analysis or system design, but such sweeps can require substantial engineering time or may rely on custom-written scripts or scripts such as Write One, Run Many (or WORM) developed outside of any software quality assurance program. With the parametric capabilities in Sampler, however, a large number of inputs can be generated automatically without recourse to scripting by individual analysts. The parametric capability can also be used in lieu of the CSAS5S search sequence to identify optimum parameters more simply with straightforward inputs and outputs. Sampler can also be used to calculate input parameters from engineering specifications. For example, diameters can be converted to radii, or masses can be used to calculate number densities. Overall, the Sampler parametric capability provides a robust feature within SCALE, eliminating the need for user-developed scripting.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crossing the Streams – Sampler and the TemplateEngine [Slides]

This presentation discusses Sampler, which is a versatile UQ and parametric study tool that can be applied to any SCALE Sequence. Sampler can perturb any quantity in any SCALE input. Recent work at ORNL has developed new types of covariance data that allow Sampler UQ to be applied to nearly all SCALE applications, including reactor depletion, UNF fuel characterization, source term analysis, and decay heat calculation. In SCALE 6.2 releases, CE data in transport cannot be perturbed. Sampler was originally designed for stochastic sampling with any sequence within SCALE and Parametric capability added in SCALE 6.2.2. Sampler can be used for uncertainty quantification, including sample data in static or depletion calculations and sample inputs for uncertainties in compositions and dimensions. The SCALE TemplateEngine allows for expanding templates to full inputs and the combination provides a powerful UQ tool.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Treatment of 1–4 Interactions in Force Fields for Molecular Dynamics Simulations

Traditional force fields commonly use a combination of bonded torsional terms and empirically scaled nonbonded interactions to capture 1-4 energies and forces of atoms separated by three bonds in a molecule. While this approach can yield accurate torsional energy barriers, it often leads to inaccurate forces and erroneous geometries and creates an interdependence between dihedral terms and nonbonded interactions, complicating parametrization and reducing transferability. Here, in this paper, we demonstrate that 1-4 interactions can be accurately modeled using only bonded coupling terms, eliminating the need for arbitrarily scaled nonbonded interactions altogether. Furthermore, by leveraging the automated parametrization capabilities of the Q-Force toolkit, we efficiently determine the necessary coupling terms without the need for manual adjustment. Our approach is first validated on a range of small molecule systems, encompassing both flexible and rigid structures, and shows a significant improvement in force field accuracy, obtaining subkcal/mol mean absolute error for every molecule tested. We further extend the bonded-only model for 1-4 interactions to Amber ff14sb, CHARMM36, and OPLS-AA force fields to reproduce ab initio gas and implicit solvent ϕ,ψ surfaces of alanine dipeptide.

Abdullah, Aalim S. [University of California, Berk↗

Experimental study on the velocity limits of magnetized rotating plasmas

An experimental study on the physical limits of the rotation velocity of magnetized plasmas is presented. Experiments are performed in the Maryland Centrifugal Experiment (MCX) [R. F. Ellis et al., Phys. Plasmas 12, 055704 (2005)], a mirror magnetic field plasma rotating azimuthally. The externally applied parameters that control the plasma characteristics--applied voltage, external magnetic field, and fill pressure--are scanned across the entire available range of values. It is found that the plasma rotation velocity does not exceed the Alfven velocity, in agreement with the equilibrium requirements of magnetically confined plasmas. Measured rotation velocities are also lower than the critical ionization velocity in hydrogen, but a strict limit was not observable within MCX parametric capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LIP: The Livermore Interpolation Package, Version 1.3

This report describes LIP, the Livermore Interpolation Package. Because LIP is a stand-alone version of the interpolation package in the Livermore Equation of State (LEOS) access library, the initials LIP alternatively stand for the ''LEOS Interpolation Package''. LIP was totally rewritten from the package described in [1]. In particular, the independent variables are now referred to as x and y, since the package need not be restricted to equation of state data, which uses variables {rho} (density) and T (temperature). LIP is primarily concerned with the interpolation of two-dimensional data on a rectangular mesh. The interpolation methods provided include piecewise bilinear, reduced (12-term) bicubic, and bicubic Hermite (biherm). There is a monotonicity-preserving variant of the latter, known as bimond. For historical reasons, there is also a biquadratic interpolator, but this option is not recommended for general use. A birational method was added at version 1.3. In addition to direct interpolation of two-dimensional data, LIP includes a facility for inverse interpolation (at present, only in the second independent variable). For completeness, however, the package also supports a compatible one-dimensional interpolation capability. Parametric interpolation of points on a two-dimensional curve can be accomplished by treating the components as a pair of one-dimensional functions with a common independent variable. LIP has an object-oriented design, but it is implemented in ANSI Standard C for efficiency and compatibility with existing applications. First, a ''LIP interpolation object'' is created and initialized with the data to be interpolated. Then the interpolation coefficients for the selected method are computed and added to the object. Since version 1.1, LIP has options to instead estimate derivative values or merely store data in the object. (These are referred to as ''partial setup'' options.) It is then possible to pass the object to functions that interpolate or invert the interpolant at an arbitrary number of points. The first section of this report describes the overall design of the package, including both forward and inverse interpolation. Sections 2-6 describe each interpolation method in detail. The software that implements this design is summarized function-by-function in Section 7. For a complete example of package usage, refer to Section 8. The report concludes with a few brief notes on possible software enhancements. For guidance on adding other functional forms to LIP, refer to Appendix B. The reader who is primarily interested in using LIP to solve a problem should skim Section 1, then skip to Sections 7.1-4. Finally, jump ahead to Section 8 and study the example. The remaining sections can be referred to in case more details are desired. Changes since version 1.1 of this document include the new Section 3.2.1 that discusses derivative estimation and new Section 6 that discusses the birational interpolation method. Section numbers following the latter have been modified accordingly.

97 MATHEMATICS AND COMPUTING↗

LIP: The Livermore Interpolation Package, Version 1.4

This report describes LIP, the Livermore Interpolation Package. Because LIP is a stand-alone version of the interpolation package in the Livermore Equation of State (LEOS) access library, the initials LIP alternatively stand for the 'LEOS Interpolation Package'. LIP was totally rewritten from the package described in [1]. In particular, the independent variables are now referred to as x and y, since the package need not be restricted to equation of state data, which uses variables {rho} (density) and T (temperature). LIP is primarily concerned with the interpolation of two-dimensional data on a rectangular mesh. The interpolation methods provided include piecewise bilinear, reduced (12-term) bicubic, and bicubic Hermite (biherm). There is a monotonicity-preserving variant of the latter, known as bimond. For historical reasons, there is also a biquadratic interpolator, but this option is not recommended for general use. A birational method was added at version 1.3. In addition to direct interpolation of two-dimensional data, LIP includes a facility for inverse interpolation (at present, only in the second independent variable). For completeness, however, the package also supports a compatible one-dimensional interpolation capability. Parametric interpolation of points on a two-dimensional curve can be accomplished by treating the components as a pair of one-dimensional functions with a common independent variable. LIP has an object-oriented design, but it is implemented in ANSI Standard C for efficiency and compatibility with existing applications. First, a 'LIP interpolation object' is created and initialized with the data to be interpolated. Then the interpolation coefficients for the selected method are computed and added to the object. Since version 1.1, LIP has options to instead estimate derivative values or merely store data in the object. (These are referred to as 'partial setup' options.) It is then possible to pass the object to functions that interpolate or invert the interpolant at an arbitrary number of points. The first section of this report describes the overall design of the package, including both forward and inverse interpolation. Sections 2-6 describe each interpolation method in detail. The software that implements this design is summarized function-by-function in Section 7. For a complete example of package usage, refer to Section 8. The report concludes with a few brief notes on possible software enhancements. For guidance on adding other functional forms to LIP, refer to Appendix B. The reader who is primarily interested in using LIP to solve a problem should skim Section 1, then skip to Sections 7.1-4. Finally, jump ahead to Section 8 and study the example. The remaining sections can be referred to in case more details are desired. Changes since version 1.1 of this document include the new Section 3.2.1 that discusses derivative estimation and new Section 6 that discusses the birational interpolation method. Section numbers following the latter have been modified accordingly.

97 MATHEMATICS AND COMPUTING↗

LIP: The Livermore Interpolation Package (V.1.5)

This report describes LIP, the Livermore Interpolation Package. LIP was totally rewritten from the package described in [1]. In particular, the independent variables are now referred to as x and y, since it is a general-purpose package that need not be restricted to equation of state data, which uses variables ρ (density) and T (temperature). LIP is primarily concerned with the interpolation of two-dimensional data on a rectangular mesh. The interpolation methods provided include piecewise bilinear, reduced (12-term) bicubic, and bicubic Hermite (biherm). There is a monotonicity-preserving variant of the latter, known as bimond. For historical reasons, there is also a biquadratic interpolator, but this option is not recommended for general use. A birational method was added at version 1.3. In addition to direct interpolation of two-dimensional data, LIP includes a facility for inverse interpolation (at present, only in the second independent variable). For completeness, however, the package also supports a compatible one-dimensional interpolation capability. Parametric interpolation of points on a two-dimensional curve can be accomplished by treating the components as a pair of one-dimensional functions with a common independent variable.

97 MATHEMATICS AND COMPUTING↗

LIP: The Livermore Interpolation Package Version 1.1

This report describes LIP, the Livermore Interpolation Package. Because LIP is a standalone version of the interpolation package in the Livermore Equation of State (LEOS) access library, the initials LIP alternatively stand for the 'LEOS Interpolation Package'. LIP was totally rewritten from the package described in. In particular, the independent variables are now referred to as x and y, since the package need not be restricted to equation of state data, which uses variables {rho} (density) and T (temperature). LIP is primarily concerned with the interpolation of two-dimensional data on a rectangular mesh. The interpolation methods provided include piecewise bilinear, reduced (12-term) bicubic, and bicubic Hermite (biherm). There is a monotonicity-preserving variant of the latter, known as bimond. For historical reasons, there is also a biquadratic interpolator, but this option is not recommended for general use. In addition to direct interpolation of two-dimensional data, LIP includes a facility for inverse interpolation (at present, only in the second independent variable). For completeness, however, the package also supports a compatible one-dimensional interpolation capability. Parametric interpolation of points on a two-dimensional curve can be accomplished by treating the components as a pair of one-dimensional functions with a common independent variable. LIP has an object-oriented design, but it is implemented in ANSI Standard C for efficiency and compatibility with existing applications. First, a 'LIP interpolation object' is created and initialized with the data to be interpolated. Then the interpolation coefficients for the selected method are computed and added to the object. The current version has options to instead estimate derivative values or merely store data in the object. It is then possible to pass the object to functions that interpolate or invert the interpolant at an arbitrary number of points. The first section of this report describes the overall design of the package, including both forward and inverse interpolation. Sections 2-5 describe each interpolation method in detail. The software that implements this design is summarized function-by-function in Section 6. For a complete example of package usage, refer to Section 7. The report concludes with a few brief notes on possible software enhancements. For guidance on adding other functional forms to LIP, refer to Appendix B. The reader who is primarily interested in using LIP to solve a problem should skim Section 1, then skip to Sections 6.1-4. Finally, jump ahead to Section 7 and study the example. The remaining sections can be referred to in case more details are desired. Changes since the previous version of this document include the new Section 1.4 that discusses partial setup options and Section 6.3 that discusses the new function lip{_}setup{_}interp that implements them. Section 6.1 and the example in Section 7 have been modified accordingly.

99 GENERAL AND MISCELLANEOUS↗

VLBI FOR GRAVITY PROBE B. IV. A NEW ASTROMETRIC ANALYSIS TECHNIQUE AND A COMPARISON WITH RESULTS FROM OTHER TECHNIQUES

When very long baseline interferometry (VLBI) observations are used to determine the position or motion of a radio source relative to reference sources nearby on the sky, the astrometric information is usually obtained via (1) phase-referenced maps or (2) parametric model fits to measured fringe phases or multiband delays. In this paper, we describe a 'merged' analysis technique which combines some of the most important advantages of these other two approaches. In particular, our merged technique combines the superior model-correction capabilities of parametric model fits with the ability of phase-referenced maps to yield astrometric measurements of sources that are too weak to be used in parametric model fits. We compare the results from this merged technique with the results from phase-referenced maps and from parametric model fits in the analysis of astrometric VLBI observations of the radio-bright star IM Pegasi (HR 8703) and the radio source B2252+172 nearby on the sky. In these studies we use central-core components of radio sources 3C 454.3 and B2250+194 as our positional references. We obtain astrometric results for IM Peg with our merged technique even when the source is too weak to be used in parametric model fits, and we find that our merged technique yields astrometric results superior to the phase-referenced mapping technique. We used our merged technique to estimate the proper motion and other astrometric parameters of IM Peg in support of the NASA/Stanford Gravity Probe B mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantification of Uncertainties and Correlations in Criticality Experiments With SCALE

Uncertainties in benchmark keff values due to uncertainties in individual components, such as geometry and material compositions, are rigorously quantified and documented in evaluations provided in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). Correlations between the uncertainties may affect not only the overall uncertainty for a series of benchmarks but also the magnitude of computational biases and bias uncertainties quantified by validation methods. The impact of the correlations in experimental uncertainties is especially important in the use of advanced validation methods such as Generalized Linear Least Squares (GLLS), as implemented in the SCALE TSURFER code. In a recent study, it was demonstrated that biases computed with GLLS procedures vary by as much as 75%, depending on the selection of the experimental uncertainty correlation value. of the >4000 benchmarks documented in the IHECSBE; experimental correlation data are only available in the DICE database tool for ~60 benchmarks. Additional data are available in DICE to identify the potential for correlations between evaluations, but the values of correlations are not quantified. The new Sampler module of SCALE provides stochastic capabilities to quantify uncertainties and correlations in keff or any other measured value for one or more benchmark experiments due to uncertainties in individual sources of uncertainty, such as geometry and material composition. The values for individual parameters in the input model are randomly modified within the reported uncertainty, and a distribution function and a series of perturbed keff values are obtained. Where sufficient samples are made, the distribution of the perturbed keff values is used to determine the uncertainty in the keff due to uncertainties in the input parameters. In cases where the same uncertainty parameters influence multiple experiments, such as where the same fissile solution or fuel rods are used for many critical measurements, the simultaneous perturbation of an uncertain parameter for multiple cases provides the correlation in keff uncertainties between the different configurations. The parametric uncertainty capabilities of Sampler for a single system are demonstrated for a benchmark exercise from the Organization for Economic Cooperation and Development (OECD) Nuclear Energy Agency (NEA) Working Party on Nuclear Criticality Safety (WPNCS) Expert Group on Uncertainty Analysis for Criticality Safety Assessment (UACSA) Phase II benchmark. Sampler is further applied to quantify correlations among benchmarks from a series of highly enriched uranium (HEU) solution (SOL) thermal spectrum (THERM) systems, through the analysis of the 10 cases from HEU-SOL-THERM-001 from the IHECSBE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimal observables for the chiral magnetic effect from machine learning

The detection of the chiral magnetic effect (CME) in relativistic heavy-ion collisions remains challenging due to substantial background contributions that obscure the expected signal. In this Letter, we present a novel machine learning approach for constructing optimized observables that significantly enhance CME detection capabilities. By parametrizing generic observables constructed from flow harmonics and optimizing them to maximize the signal-to-background ratio, we systematically develop CME-sensitive measures that outperform conventional methods. Using simulated data from the anomalous viscous fluid dynamics framework, our machine learning observables demonstrate up to 90% higher sensitivity to CME signals compared to traditional 𝛾 and 𝛿 correlators, while maintaining minimal background contamination. The constructed observables provide physical insight into optimal CME detection strategies and offer a promising path forward for experimental searches of the CME at the BNL Relativistic Heavy Ion Collider and the CERN Large Hadron Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CrossLink: General Overview [Slides]

Problem: Traditional mesh generation approaches are labor intensive and have limited robustness when applied to parametric design exploration and optimization of complex geometries. While automatic mesh generation approaches exist, they tend to generate tetrahedral or mixed-hybrid meshes which are generally unsuitable for physics applications with strong shock waves, thin boundary layers, and strong gradients. In addition, simulations sizes in the billions of cells are becoming more common with traditional mesh generation methods quickly reaching scalability limits. Solution: CrossLink offers a topology-based mesh generation approach with unstructured block-filling methods and a scalable mesh generation engine. In addition, CrossLink incorporates a python-based API for seamless workflow integration and robust repeatability of the geometry handling and mesh generation process. This makes it ideal for parametric design study and optimization of complex geometries. Finally, future versions of CrossLink will offer a parametric mesh capability that optimizes a high-order mesh and enables reconstruction of the final mesh in memory by the physics solver.

97 MATHEMATICS AND COMPUTING↗

CrossLink: Advancements in Scalable Unstructured Mesh Generation [Slides]

Traditional mesh generation approaches are labor intensive and have limited robustness when applied to parametric design exploration and optimization of complex geometries. While automatic mesh generation approaches exist, they tend to generate tetrahedral or mixed-hybrid meshes which are generally unsuitable for physics applications with strong shock waves, thin boundary layers, and strong gradients. In addition, simulations sizes in the billions of cells are becoming more common with traditional mesh generation methods quickly reaching scalability limits. CrossLink offers a topology-based mesh generation approach with unstructured block-filling methods and a scalable mesh generation engine. In addition, CrossLink incorporates a python based API for seamless workflow integration and robust repeatability of the geometry handling and mesh generation process. This makes it ideal for parametric design study and optimization of complex geometries. Finally, future versions of CrossLink will offer a parametric mesh capability that optimizes a high-order mesh and enables reconstruction of the final mesh in memory by the physics solver.

97 MATHEMATICS AND COMPUTING↗

simuwatt - A Tablet Based Electronic Auditing Tool

'simuwatt Energy Auditor' (TM) is a new tablet-based electronic auditing tool that is designed to dramatically reduce the time and cost to perform investment-grade audits and improve quality and consistency. The tool uses the U.S. Department of Energy's OpenStudio modeling platform and integrated Building Component Library to automate modeling and analysis. simuwatt's software-guided workflow helps users gather required data, and provides the data in a standard electronic format that is automatically converted to a baseline OpenStudio model for energy analysis. The baseline energy model is calibrated against actual monthly energy use to ASHRAE Standard 14 guidelines. Energy conservation measures from the Building Component Library are then evaluated using OpenStudio's parametric analysis capability. Automated reporting creates audit documents that describe recommended packages of energy conservation measures. The development of this tool was partially funded by the U.S. Department of Defense's Environmental Security Technology Certification Program. As part of this program, the tool is being tested at 13 buildings on 5 Department of Defense sites across the United States. Results of the first simuwatt audit tool demonstration are presented in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transmutation Scoping Studies for a Chloride Molten Salt Reactor

Over the past few years, there has been strong renewed interest from private industry, mostly from start-up enterprises, in molten salt reactor (MSR) technologies because of the unique properties of this class of reactors. These are reactors in which the fuel is homogeneously mixed with the coolant in the form of liquid salts and is circulated continuously into and out of the active core region with on-line fuel management, salt treatment, and salt processing. In response to such wide-spread interest, Argonne National Laboratory is expanding its well-established reactor modelling and simulation expertise and infrastructure to enable detailed analysis and design of MSRs. The tools being developed are able to simulate the continuous fuel flow, the complex on-line fuel management and elemental removal processes (e.g., fission product removal) using depletion steps representative of a real MSR system. Leveraging these capabilities, a parametric study on the transmutation performance of a simplified actinide-burning MSR concept that uses a chloride-based salt was performed. This type of salt has attracted attention over the more commonly discussed fluoride-based salts since no tritium is produced as a result of irradiation and it is compatible with a fast neutron spectrum. The studies discussed in this paper examine the performance of a burner MSR design with a fixed core size and power density over a range of possible fuel salt molar ratios with NaCl-MgCl2 as the carrier salt. The intent is to quantify the impact on the required transuranics content of the make-up fuel, the actinide transmutation rates, and other performance characteristics for typical burner MSR designs.

Heidet, Florent↗

An Efficient Time-Domain Model to Simulate Parametric Resonances in a Floating Body Free to Move in Six Degrees of Freedom: Preprint

We present a computationally efficient time-domain model capable of simulating parametric resonances in a floating body in waves. The model assumes all wave forces to be linear, but the inertia and restoring forces acting on the body are expanded to second order in body motions. The simulation speed on a standard computer is approximately 40 times faster than real time. The model is applied to a soft-moored floating axisymmetric body which absorbs energy through heave, but is otherwise free to move in six degrees of freedom. Under certain conditions, we show that the body responds parametrically with large amplitudes not only in surge and pitch, but also in sway, roll, and yaw, provided it is given some small initial displacement in one of these out-of-plane modes. The predictions are confirmed by simulations using state-of-the-art nonlinear Froude-Krylov and computational fluid dynamics models.

parametric resonance↗

Parametric Vehicle Choice Modeling: ParaChoice

Assess the evolving integration potential of light-duty (LDV) and heavy-duty vehicle (HDV) technologies, fuels, and infrastructure and their contributions to lowering emissions and petroleum consumption. Leverage existing LDV and build HDV ParaChoice capability to conduct parametric analyses that explore the trade-space for key factors that influence consumer choice and technology, fuel and infrastructure development. ParaChoice provides the unique capability to examine tipping points and tradeoffs, and can help quantify the effects of and mitigate uncertainty introduced by data sources and assumptions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗