Search NASA⌕ Search

SEARCH · Search NASA

Results for “Partial gamma-ray cross sections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

pyEGAF: Modernization of the EGAF database

One of the most comprehensive resources for thermal neutron-capture data is the Evaluated Gamma-ray Activation File (EGAF), containing data from prompt gamma activation analysis measurements carried out at the Budapest Research Reactor for 245 isotopes. Although these valuable datasets have been freely available for many years, the outdated and cryptic adopted format makes it difficult to utilize the data and it is not generally suitable for modern computational technologies. Furthermore, to help overcome these challenges, we have converted the datasets into an open standard JSON format. Additionally, we have developed a Python implementation of an open-source software package, pyEGAF, designed to interact with the JSON data structures for general purpose access, manipulation, and rapid assessment of the capture-gamma data in EGAF.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

pyEGAF: An open-source Python library for the Evaluated Gamma-ray Activation File

The Evaluated Gamma-ray Activation File (EGAF) is one of the most comprehensive resources for thermal neutron-capture data. This database contains data from prompt gamma activation analysis measurements carried out in a consistent manner using the same experimental configuration at the Budapest Research Reactor for 245 isotopes. Although these valuable datasets have been freely available for many years, one of the drawbacks is the outdated and cryptic Evaluated Nuclear Structure Data File (ENSDF) format that is currently adopted for dissemination, making it difficult for users unfamiliar with the format to access and utilize the data contained therein. Furthermore, the ENSDF format does not readily lend itself to modern computational technologies and a parser is required to interpret the complicated mixed-record format. To help overcome these challenges, we have developed a translator to convert the ENSDF-formatted datasets into an open standard JavaScript Object Notation (JSON) format enabling accessibility to applications using different programming languages running in different environments. To compliment this effort, we have also developed an open-source software package implemented in Python, pyEGAF, that is designed to interact with the JSON data structures for general purpose access, manipulation, and analysis of the neutron-capture $\gamma$-ray data in EGAF. The new format, together with the pyEGAF library, greatly enhances access to the wider applications community where EGAF data may be useful or is required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

X-ray and gamma-ray tomographic imaging of fuel relocation inside sodium fast reactor test assemblies during severe accidents

The present work reports on x-ray and gamma-ray high-spatial resolution computerized tomography measurements of the Pin Bundle Metallic Fuel Relocation (PBR) assemblies tested in the Metallic Uranium Safety Experiment (MUSE) facility at Argonne National Lab (ANL). The aim of the study was to characterize fuel relocation structures that develop during severe core accidents pertaining to SFR assemblies; these include but are not limited to advanced core disruption recreated in the PBR-1 assembly, and cladding breach recreated in the PBR-2 assembly. We report the x-ray tomography measurements were able to resolve small quantities of relocation fuel; with increased presence of relocation fuel, the x-ray 1measurements spatially mapped the material but could not resolve the inner regions of these. The gamma-tomography measurements showed improved results, resolving the relocation structures in great detail. The upper plenum of the PBR-1 assembly where the molten uranium was initially inserted presented high structural damage, reflected by the partial and complete disintegration of the central rods. Relocation fuel filled the subchannels, adhering to surviving cladding walls and the assembly casing. In the lower portion of the measured section, the tomogram degrades due to photon starvation effects hinting at the increased amount of relocation fuel potentially plugging the assembly; flow blockage in this section was difficult to determine due to the tomogram’s degradation from photon starvation. Small fragments were observed further down the assembly, dislodged from the initial insertion of the molten material. This section was used as an unperturbed assembly reference, with a calculated blockage of less than 1% from the present fragments. The PBR-2 assembly was characterized by columnar relocation structures propagating through the subchannels. Three of the relocation structures were captured in the measured section, with evidence of cross migration on to adjacent subchannels. The measured section in this assembly captures the leading edge of two structures. The calculated flow blockage was 16% in the planes where the three relocation structures are present, but this quickly decreases to approximately 5% past the leading edge of two of the structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗