Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle image velocimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Particle image velocimetry

Particle imaging velocimetry, which is rapidly becoming an essential tool for the synoptic measurement of two dimensional velocity fields, is addressed. This rapid development is carried out by a growing number of fluid mechanics experimentalists who recognize the unique capabilities of the technique to measure velocity fields in both space and time, and is supported by the concomitant development and availability of microcomputer hardware and software. Various applications of the technique to map different flow regimes are described and illustrated. Hardware implementations of the technique which utilize both conventional photography for image acquisition as well as digital 'online' methods for integrated image acquisition and processing are discussed. Recommendations to further enhance the technique and make it possible to map the three velocity components in three dimensional flow regions are given.

Lourenco, L. M.↗

Turbulent Flow Field Measurements of Separate Flow Round and Chevron Nozzles with Pylon Interaction Using Particle Image Velocimetry

Particle Image Velocimetry (PIV) measurements for six separate flow bypass ratio five nozzle configurations have recently been obtained in the NASA Langley Jet Noise Laboratory. The six configurations include a baseline configuration with round core and fan nozzles, an eight-chevron core nozzle at two different clocking positions, and repeats of these configurations with a pylon included. One run condition representative of takeoff was investigated for all cases with the core nozzle pressure ratio set to 1.56 and the total temperature to 828 K. The fan nozzle pressure ratio was set to 1.75 with a total temperature of 350 K, and the freestream Mach number was M = 0.28. The unsteady flow field measurements provided by PIV complement recent computational, acoustic, and mean flow field studies performed at NASA Langley for the same nozzle configurations and run condition. The PIV baseline configuration measurements show good agreement with mean flow field data as well as existing PIV data acquired at NASA Glenn. Nonetheless, the baseline configuration turbulence profile indicates an asymmetric flow field, despite careful attention to concentricity. The presence of the pylon increases the upper shear layer turbulence levels while simultaneously decreasing the turbulence levels in the lower shear layer. In addition, a slightly shorter potential core length is observed with the addition of the pylon. Finally, comparisons of computational results with PIV measurements are favorable for mean flow, slightly over-predicted for Reynolds shear stress, and underpredicted for Reynolds normal stress components.

Doty, Michael J.↗

Particle-Displacement Tracking In Particle-Image Velocimetry

Particle images processed rapidly and automatically into velocity-vector maps. This technique requires no processing of photographic plates, no tedious visual recognition and manual designation of large numbers of image features for subsequent processing, little or no interruption by technician and is order of magnitude faster than any of prior techniques.

Wernet, Mark P.↗

Two-dimensional particle displacement tracking in particle imaging velocimetry

A new particle imaging velocimetry data acquisition and analysis system, which is an order of magnitude faster than any previously proposed system, has been constructed and tested. The new particle displacement tracking (PDT) system is an all electronic technique employing a video camera and a large memory buffer frame-grabber board. Using a simple encoding scheme, a time sequence of single exposure images is time-coded into a single image and then processed to track particle displacements and determine two-dimensional velocity vectors. Use of the PDT technique in a counterrotating vortex flow produced over 1100 velocity vectors in 110 s when processed on an 80386 PC.

Wernet, Mark P.↗

On the Use of Mahalanobis Distance in Particle Image Velocimetry Post-Processing

Particle Image Velocimetry (PIV) is a method of flow measurement that has become increasingly popular as an experimental tool. New technology has made high-speed and higher-dimension (stereoscopic, tomographic, etc) methods available to an ever-growing population of researchers. These advanced methods can provide significantly more data than traditional low-speed planar PIV, but these larger data sets also require more resources to process and store. A major time sink in the post-processing of large PIV data sets is the identification and rejection of “bad” or ”spurious” vectors that survive an initial processing step in commercial software, which attempts to identify spurious vectors on an image-by-image basis and not with respect to repeated trials. The Mahalanobis distance, an almost 100-year-old statistical function, was determined to be well suited for this task for its computational efficiency and higher-dimensional nature. This work includes a summary of the Mahalanobis distance and validation of its usefulness as a tool for outlier rejection in the post-processing of PIV data.

Experimental Methods↗

Particle Image Velocimetry Applications Using Fluorescent Dye-Doped Particles

Polystyrene latex sphere particles are widely used to seed flows for velocimetry techniques such as Particle Image Velocimetry (PIV) and Laser Doppler Velocimetry (LDV). These particles may be doped with fluorescent dyes such that signals spectrally shifted from the incident laser wavelength may be detected via Laser Induced Fluorescence (LIF). An attractive application of the LIF signal is achieving velocimetry in the presence of strong interference from laser scatter, opening up new research possibilities very near solid surfaces or at liquid/gas interfaces. Additionally, LIF signals can be used to tag different fluid streams to study mixing. While fluorescence-based PIV has been performed by many researchers for particles dispersed in water flows, the current work is among the first in applying the technique to micron-scale particles dispersed in a gas. A key requirement for such an application is addressing potential health hazards from fluorescent dyes; successful doping of Kiton Red 620 (KR620) has enabled the use of this relatively safe dye for fluorescence PIV for the first time. In this paper, basic applications proving the concept of PIV using the LIF signal from KR620-doped particles are exhibited for a free jet and a twophase flow apparatus. Results indicate that while the fluorescence PIV techniques are roughly 2 orders of magnitude weaker than Mie scattering, they provide a viable method for obtaining data in flow regions previously inaccessible via standard PIV. These techniques have the potential to also complement Mie scattering signals, for example in multi-stream and/or multi-phase experiments.

Petrosky, Brian J.↗

Time-resolved particle image velocimetry

Time-resolved particle image velocimetry (TR-PIV) has become widespread in fluid dynamics. Essentially a velocity field movie, the dynamic content provides temporal as well as spatial information, in contrast to conventional PIV offering only statistical ensembles of flow quantities. From these time series arise further analyses such as accelerometry, space-time correlations, frequency spectra of turbulence including spatial variability, and derivation of pressure fields and forces. The historical development of TR-PIV is chronicled, culminating in an assessment of the current state of technology in high-repetition-rate lasers and high-speed cameras. Commercialization of pulse-burst lasers has expanded TR-PIV into more flows, including the compressible regime, and has achieved MHz rates. Particle response times and peak locking during image interrogation require attention but generally are not impediments to success. Accuracy considerations are discussed, including the risks of noise and aliasing in spectral content. Oversampled TR-PIV measurements allow use of multi-frame image interrogation methods, which improve the precision of the correlation and raise the velocity dynamic range of PIV. In combination with volumetric methods and data assimilation, a full four-dimensional description of a flow is not only achievable but becoming standardized. Lastly, a survey of exemplary applications is followed by a few predictions concerning the future of TR-PIV.

47 OTHER INSTRUMENTATION↗

Meta-uncertainty for particle image velocimetry

Uncertainty quantification for Particle Image Velocimetry (PIV) is critical for comparing experimentally measured flow fields with Computational Fluid Dynamics (CFD) results, and model design and validation. However, PIV features a complex measurement chain with coupled, non-linear error sources, and quantifying the uncertainty is challenging. Multiple assessments show that none of the current methods can reliably measure the actual uncertainty across a wide range of experiments, and estimates can vary. Because the current methods differ in assumptions regarding the measurement process and calculation procedures, it is not clear which method is best to use for an experiment where the error distribution is unknown. To address this issue, we propose a method to estimate an uncertainty method's sensitivity and reliability, termed the Meta-Uncertainty. The novel approach is automated, local, and instantaneous, and based on perturbation of the recorded particle images. We developed an image perturbation scheme based on adding random unmatched particles to the interrogation window pair considering the signal-to-noise (SNR) of the correlation plane. Each uncertainty scheme's response to several trials of random particle addition is used to estimate a reliability metric, defined as the rate of change of the inter-quartile range (IQR) of the uncertainties with increasing levels of particle addition. We also propose applying the meta-uncertainty as a weighting metric to combine uncertainty estimates from individual schemes, based on ideas from the consensus forecasting literature. We use planar and stereo PIV measurements across a range of canonical flows to assess the performance of the uncertainty schemes. Further, a novel method is introduced to assess an uncertainty scheme's performance based on a quantile comparison of the error and uncertainty distributions, generalizing the current method of comparing the RMS of the two distributions. Here, the results show that the combined uncertainty method outperforms the individual methods, and this work establishes the meta-uncertainty as a useful reliability assessment tool for PIV uncertainty quantification.

47 OTHER INSTRUMENTATION↗

Application of Digital Particle Imaging Velocimetry to Turbomachinery

Digital Particle Imaging Velocimetry (DPIV) is a powerful measurement technique, which can be used as an alternative or complementary approach to Laser Doppler Velocimetry (LDV) in a wide range of research applications. The instantaneous planar velocity measurements obtained with PIV make it an attractive technique for use in the study of the complex flow fields encountered in turbomachinery. Many of the same issues encountered in the application of LDV to rotating machinery apply in the application of PIV. Techniques for optical access, light sheet delivery, CCD camera technology and particulate seeding are discussed. Results from the successful application of the PIV technique to both the blade passage region of a transonic axial compressor and the diffuser region of a high speed centrifugal compressor are presented. Both instantaneous and time-averaged flow fields were obtained. The 95% confidence intervals for the time-averaged velocity estimates were also determined. Results from the use of PIV to study surge in a centrifugal compressor are discussed. In addition, combined correlation/particle tracking results yielding super-resolution velocity measurements are presented.

Wernet, Mark P.↗

Young's fringe particle image velocimetry in the presence of random particle motions

In the Young's fringe approach to particle image velocimetry, random particle motions cause loss of fringe visibility by decorrelating the coherent interexposure particle separations responsible for fringe formation. Since the visibility reduction is determined by the random motion through a Fourier transform relation analogous to the Van Cittert Zernike Theorem, it has been proposed that the random motion can be characterized statistically by analyzing fringe visibility distributions in the transform plane. This paper assesses the accuracy of such measurements. In particular, the effects of finite particle population and of correlated random motion are evaluated. The theory applies to diffusive motion, turbulence, and to random motion caused by mean velocity inhomogeneities.

Rubinstein, R.↗

Time Resolved Particle Image Velocimetry in Nozzle Flow

Temporally resolved particle image velocimetry (TR-PIV) is the newest and most exciting tool recently developed to support our continuing efforts to characterize and improve our understanding of the decay of turbulence in jet flows—a critical element for understanding the acoustic properties of the flow. A new TR-PIV system has been developed at the NASA Glenn Research Center which is capable of acquiring planar PIV image frame pairs at up to 25 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered six nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centred along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space–time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number.

Temporally Resolved Particle Image Velocimetry↗

Flow-Field Measurements in a Wing-Fuselage Junction Using an Embedded Particle Image Velocimetry System

A novel, embedded, 2D Particle Image Velocimetry system has been developed and implemented to obtain off-body velocity measurements in the junction of an 8% wing-body configuration in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. Although the initial purpose for implementing the system during this test was to evaluate system performance and identify potential risks, the system worked remarkably well and a considerable amount of data were obtained in the wing-fuselage junction near the trailing edge at a Reynolds Number of 2.4 Million and angle of attack of 5 degrees. In addition to providing notable efficiencies with regard to image acquisition and test operations, the PIV system proved to be quite capable of capturing unique details of the flow separation to complement the extensive suite of measurement techniques applied during the test. Instantaneous PIV vector fields reveal that the flow separation is not stationary but rather highly dynamic. Mean flow statistics calculated from the PIV measurements highlight where reverse flow and Reynolds stresses are concentrated in the separated region and agree well with results from the embedded Laser Doppler Velocimeter system and Computational Fluid Dynamics. The comparisons and additional insight gained during this effort will help guide system improvements for follow-on tests.

Jenkins, Luther N.↗

Particle Imaging Velocimetry Used in a Transonic Compressor Facility

Particle Imaging Velocimetry (PIV) is an optical technique whereby a pulsed laser sheet is used to illuminate particles entrained in a fluid across an extended planar cross section of a flow field. Electronic recording of the particle positions at two closely timed laser pulses permits the computation of the flow velocity. PIV captures the instantaneous flow field, permitting the study of unsteady flow phenomena. Mean flow statistics can be computed by acquiring several hundred images and averaging the results. The first-ever successful application of PIV to acquire measurements in a high-speed rotating turbomachinery blade row was completed in NASA Lewis Research Center's W-8 Single Stage Axial Compressor Facility. Measurements were acquired in a 20-in.-diameter transonic compressor rotor operating at 17,188 rpm. A custom-designed light-sheet generating probe was used to insert the high-energy, pulsed light-sheet illumination required for recording the unblurred images of particles entrained in the fluid. Measurements of the shock wave formed within the rotor blade passage and of unsteady structures within the blade wakes were acquired. These measurements provide insight into unsteady spatial structures in the flow field which cannot be measured with the more conventional laser anemometry technique. The PIV technique provides both instantaneous and average velocity data in a transonic compressor in an order of magnitude less time than required for other conventional optical diagnostic techniques.

Wernet, Mark P.↗

Recent Advances in Particle Image Velocimetry

This paper presents new trends in Particle Image Velocimetry and practical aspects relevant to the application of the technique to large scale wind tunnel testing. The various problems and their solutions to the operation of PIV in large scale wind tunnels are discussed. Application of the technique in mapping complex flows are also presented.

Lourenco, L.↗

Particle image velocimetry for the surface tension driven convection experiment using a particle displacement tracking technique

The Surface Tension Driven Convection Experiment (STDCE) is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the USML-1 Spacelab mission planned for 1992. One of the components of data collected during the experiment is a video record of the flow field. This qualitative data is then quantified using an all electronic, two-dimensional particle image velocimetry technique called particle displacement tracking (PDT) which uses a simple space domain particle tracking algorithm. The PDT system is successful in producing velocity vector fields from the raw video data. Application of the PDT technique to a sample data set yielded 1606 vectors in 30 seconds of processing time. A bottom viewing optical arrangement is used to image the illuminated plane, which causes keystone distortion in the final recorded image. A coordinate transformation was incorporated into the system software to correct this viewing angle distortion. PDT processing produced 1.8 percent false identifications, due to random particle locations. A highly successful routine for removing the false identifications was also incorporated, reducing the number of false identifications to 0.2 percent.

Wernet, Mark P.↗

Particle image velocimetry for the Surface Tension Driven Convection Experiment using a particle displacement tracking technique

The Surface Tension Driven Convection Experiment (STDCE) is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the USML-1 Spacelab mission planned for 1992. One of the components of data collected during the experiment is a video record of the flow field. This qualitative data is then quantified using an all electronic, two-dimensional particle image velocimetry technique called particle displacement tracking (PDT) which uses a simple space domain particle tracking algorithm. The PDT system is successful in producing velocity vector fields from the raw video data. Application of the PDT technique to a sample data set yielded 1606 vectors in 30 seconds of processing time. A bottom viewing optical arrangement is used to image the illuminated plane, which causes keystone distortion in the final recorded image. A coordinate transformation was incorporated into the system software to correct this viewing angle distortion. PDT processing produced 1.8 percent false identifications, due to random particle locations. A highly successful routine for removing the false identifications was also incorporated, reducing the number of false identifications to 0.2 percent.

Wernet, Mark P.↗

Surge Flow in a Centrifugal Compressor Measured by Digital Particle Image Velocimetry

A planar optical velocity measurement technique known as Particle Image Velocimetry (PIV) is being used to study transient events in compressors. In PIV, a pulsed laser light sheet is used to record the positions of particles entrained in a fluid at two instances in time across a planar region of the flow. Determining the recorded particle displacement between exposures yields an instantaneous velocity vector map across the illuminated plane. Detailed flow mappings obtained using PIV in high-speed rotating turbomachinery components are used to improve the accuracy of computational fluid dynamics (CFD) simulations, which in turn, are used to guide advances in state-of-the-art aircraft engine hardware designs.

Wernet, Mark P.↗