Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Targeted Particle Fractionation Technologies: Proof of Concept

Most methods of particle-size analysis involve particle fractionation which, is often done by filtration or the use of screens. This paper provides proof of concept testing for new in-pipe particle fractionation technologies that can be used at laboratory to industrial scales. These technologies are extensions of recent advancements in bump arrays as well as testing of new inline angled-to-the-flow slats, and advanced boycott-based Avalanche separation technologies. Experiments were conducted for three targeted particle fractionation technologies to evaluate the in-pipe removal of oversized sands in Newtonian slurries prior to the introduction of bump arrays. The mesofluidic system uses an array of staggered posts as configured in a bump array for Newtonian slurry conditions. The methods and results of these experiments are described in this paper. This information could be applied in most industrial and laboratory systems to rapidly remove oversized particles from a flowing slurry.

slurry, solids removal, particle fractionation, bu↗

PSD Technologies for Particle Physics

I will give a brief overview of the use of position sensitive devices for particle physics. I will focus on silicon-based systems only. In addition to the depiction of a suite of recently designed, built, and operated detectors I will also introduce planned near term additions. I will conclude with a brief outlook regarding challenges for silicon detector applications for future colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position sensitive device technologies for particle physics

Here, I will give a brief overview of the use of position sensitive devices for particle physics. I will focus on silicon-based systems only. In addition to the depiction of a suite of recently designed, built, and operated detectors I will also introduce planned near term additions. I will conclude with a brief outlook regarding challenges for silicon detector applications for future colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Italian Summer Students Program at Fermilab and other US Laboratories: 40 years of education in particle physics and technology

Since 1983 the Italian groups collaborating with Fermilab (US) have been running a 2-month summer training program for Master students. While in the first year the program involved only 4 physics students, in the following years it was extended to engineering students. Many students have extended their collaboration with Fermilab with their Master Thesis and PhD. The program has involved almost 600 Italian students from more than 20 Italian universities. Each intern is supervised by a Fermilab Mentor responsible for the training program. Training programs spanned from Tevatron, CMS, Muon (g-2), Mu2e and SBN and DUNE design and data analysis, development of particle detectors, design of electronic and accelerator components, development of infrastructures and software for tera-data handling, quantum computing and research on superconductive elements and accelerating cavities. In 2015 the University of Pisa included the program within its own educational programs. Summer Students are enrolled at the University of Pisa for the duration of the internship and at the end of the internship they write summary reports on their achievements. After positive evaluation by a University of Pisa Examining Board, interns are acknowledged 6 ECTS credits for their Diploma Supplement. In the years 2020 and 2021 the program was canceled due to the sanitary emergency but in 2022 it was restarted and allowed a cohort of 21 students in 2022, and a cohort of 27 students in 2023 to be trained for nine weeks at Fermilab. We are now organizing the 2024 program.

Barzi, Emanuela↗

The Italian Summer Students Program at Fermilab and other US Laboratories: 40 years of education in particle physics and technology

Since 1983 the Italian groups collaborating with Fermilab (US) have been running a 2-month summer training program for Master students. While in the first year the program involved only 4 physics students, in the following years it was extended to engineering students. Many students have extended their collaboration with Fermilab with their Master Thesis and PhD. The program has involved more than 600 Italian students from more than 20 Italian universities. Each intern is supervised by a Fermilab Mentor responsible for the training program. Training programs spanned from Tevatron, CMS, Muon (g-2), Mu2e and SBN (MicroBooNE, Icarus, and SBND) and DUNE design and data analysis, development of particle detectors, design of electronic and accelerator components, development of infrastructures and software for tera-data handling, quantum computing and research on superconductive elements and accelerating cavities. In 2015 the University of Pisa included the program within its own educational programs. Summer Students are enrolled at the University of Pisa for the duration of the internship and at the end of the internship they write summary reports on their achievements. After positive evaluation by a University of Pisa Examining Board, interns are acknowledged 6 ECTS credits for their Diploma Supplement. The program was paused in 2020 and 2021 due to the COVID-19 pandemic, but it resumed in 2022. From 2022 to 2024, a total of 60 students participated in the nine-week training at Fermilab. We are currently organizing the 2025 program. This paper provides an overview of the program, which can serve as a model for other interested laboratories.

Barzi, Emanuela [Ohio State U.]↗

Aerosol Microphysics and Chemical Measurements at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024 UCSD Library Collection

This dataset includes guest instrument measurements and other PI products for aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diameter size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). The data are available at the following link: https://library.ucsd.edu/dc/collection/bb0898306q

54 ENVIRONMENTAL SCIENCES↗

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analog Signal Multiplexing System for the Iota Proton Injector

The Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Operations is to commission the 2.5 MeV IOTA Proton Injector (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function correctors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103↗

Analog Signal Multiplexing System for the IOTA Proton Injector

he Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Opera-tions is to commission the 2.5 MeV IOTA Proton Injec-tor (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function cor-rectors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103↗

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

Refinement and demonstration of a coupled BISON-Griffin workflow for designing targeted TRISO transient experiments in TREAT

The U.S. nuclear industry is expected to deploy tristructural isotropic (TRISO) particle fuel technologies for commercial reactors within the next decade. In previous work, we defined a preliminary transient design space for TRISO fuels, identified potential gaps in the available data, and began to develop multiphysics modeling tools that could be applied to design targeted Transient Reactor Test Facility (TREAT) experiments to fill these gaps. Here, this work builds on that foundation by (1) updating BISON fuel performance and Griffin reactor physics models to reflect the current TREAT experiment tube and capsule designs, (2) coupling the codes to improve the accuracy and usability of the transient design analyses, and (3) demonstrating their use over an expanded design space that includes fuel burnup. The simulated mechanical responses of the TRISO particles were complex functions of fission product accumulation, fission gas release, and irradiation-induced dimensional change in the pyrolytic carbon layers. The predicted tangential stresses in the particles' silicon carbide layers were least compressive for preheated tests involving fresh fuels but remained compressive throughout the ranges of temperature, heat rate, and burnup considered in this work. Finally, comparisons between the potential TREAT transients and historical test reactor irradiations showed that the TREAT tests would produce significantly lower average energy deposition rates, yielding less severe transients with greater relevance to near-term commercial applications. The use of these predictive capabilities has the potential to increase the value of each test, improving the overall efficiency and cost-effectiveness of transient testing for TRISO and other advanced fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Refined BISON-Griffin Workflow For Designing Targeted TRISO Transient Experiments In The Transient Reactor Test Facility

U.S. industry is expected to deploy tristructural isotropic (TRISO) particle fuel technologies for commercial reactors within the next decade. In our previous work, we defined a preliminary transient design space for TRISO fuels, identified potential gaps in the available data, and began to develop multiphysics modeling tools that could be applied to design targeted Transient Reactor Test Facility (TREAT) experiments to fill these gaps. This work builds on that foundation by (1) updating BISON fuel performance and Griffin reactor physics models to reflect the current TREAT experiment tube and capsule designs,(2) coupling the codes to improve the accuracy and usability of the transient design analyses, and (3) demonstrating their use over an expanded design space that includes fuel burnup. The simulated mechanical responses of the TRISO particles were complex functions of fission product accumulation, fission gas release, and irradiation-induced dimensional change in the pyrolytic carbon layers. Predicted tangential stresses in particle silicon carbide layers were least compressive for preheated tests involving fresh fuels but remained compressive throughout the ranges of temperature, heat rate, and burnup considered in this work. Finally, comparisons between the potential TREAT transients and historical test reactor irradiations showed that the TREAT tests would produce significantly lower average energy deposition rates, yielding less severe transients with greater relevance to near-term commercial applications. Use of these predictive capabilities has the potential to increase the value of each test, improving the overall efficiency and cost effectiveness of transient testing for TRISO and other advanced fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Collaborative Research: Vlasov–Maxwell Simulations to resolve electron heating and dissipation, in quasiperpendicular shocks (Final Technical Report)

The project is to study electron heating at quasi-perpendicular shocks. We have analyzed measurements from the Magnetosphere Multiscale (MMS) spacecraft and particle-in-cell simulations to address the question. One key discovery is that waves and are excited in the shock transition region, which further develop into complicated structures and thin current layers, which contribute to accelerate and heat electrons. We further investigated the excitation and evolution of these waves and structures, and their association with ion and electron dynamics. In addition, the analysis technique of Vlasov equation terms is further applied to study electron dynamics at the dayside magnetopause, to understand the effect of density, velocity and temperature variations on electron distributions and kinetics.

58 GEOSCIENCES↗

Application of Superconducting Cavities as Ultra-Sensitive RF Photon Detectors

Superconducting radio frequency (SRF) cavities are the world’s most efficient engineered oscillators, and they have long been employed for extremely high efficiency transfer of energy to beams of charged particles. Decades of R&D for particle accelerators have led to modern treatments for SRF cavities that achieve higher performance than was previously possible. Advanced SRF cavities using particle accelerator technology are now being used to search for new physics, including dark matter and gravitational waves. The extremely high Q makes it possible to search for very small signals from photons in the radio frequency range, and the extremely high electric fields makes it possible to perform experiments that involve pumping one mode of a cavity in order to search for power transfer mediated by new physics. This talk will present novel experiments that employ SRF cavities, including searches for axions and dark photons dark matter, light-shining-through-walls, and high frequency gravitational waves. Results to be presented include searches with world record sensitivity.

43 PARTICLE ACCELERATORS↗