Passive Safety System [Slides]
These slides are intended as an introduction to the concept of passive safety systems in LWRs and a discussion on designs that incorporate passive safety.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
These slides are intended as an introduction to the concept of passive safety systems in LWRs and a discussion on designs that incorporate passive safety.
This paper presents necessary and sufficient conditions for validating spacecraft passive safety using relative orbital elements (ROE) centered around the far-field to near-field trajectory design of a hypothetical autonomous rendezvous and docking (AR&D) mission. The specific formulation of the ROEs used in this study are of quasi-nonsingular form based on elative eccentricity/inclination vectors. Current methodologies for ensuring passive safety apply keep-out volumes (KOV) to maintain appropriate separation between the Servicer and Client. Widely used techniques to assess the integrity of the KOV involve forward propagation of the relative Cartesian state to check for a potential KOV breach. In this study, an alternative approach to the propagation-based method is proposed using ROEs due to their valuable geometric insights of spacecraft relative motion. Modeling the relative trajectory and KOV ellipsoids as ellipses into the 2-D ROE sub-space simplifies the passive safety validation to a root-finding problem within the unit disk with high computational efficiency. Other approaches to intersection detection of the KOV are also evaluated in accuracy and run-time. Furthermore, a Monte Carlo simulation was employed to compare the ROE-based and relative Cartesian approaches in terms of maneuver error.
Advanced (Non-Light Water) Reactors are being designed with Passive Safety as an essential and integral feature. To help streamline the licensing of advanced reactors, the DOE and the NRC have drafted Principal Design Criteria (PDCs) for advanced reactors. A question that remains to be answered is: how an Advanced Reactor take credit for passive safety features inherent in certain advanced reactors while at the same time complying the evolving PDC.
This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen--a noncondensable gas (NCG), simulating air in the reactor containment--to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted--utilizing iterative and nodalized mass and heat transfer calculation to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results--a ratio of experimental and Nusselt's theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment.
This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen (N)—a noncondensable gas (NCG), simulating air in the reactor containment—to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted—utilizing iterative and nodalized mass and heat transfer calculation—to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results—a ratio of experimental and Nusselt’s theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment
This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.
This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.
Explore the source record for details and available documents.
High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.
The FFTF liquid sodium cooled test reactor was built to assist the development and testing of advanced fuels and material for fast reactors. The goals of the FFTF Passive Safety Testing program included confirming the safety margins of FFTF as a liquid metal reactor, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of its specific design features. The program included thirteen unprotected loss of flow without scram tests. In preparation for the Passive Safety Testing program, a series of individual reactivity feedback tests were performed which were designed to simulate and validate specific features and reactivity feedbacks of the FFTF core.
The Columbia Basin Consulting Group (CBCG) is developing an advanced reactor cooled by Lead-Bismuth (Pb-Bi). The design is being developed for a high level of passive safety. It has the advantages of the classical liquid metal (sodium) reactor, i.e. small size and passive safety, while having the additional advantage of chemically inert coolant.
The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.
The passive safety systems (PSSs) within water-cooled reactors are meticulously engineered to function autonomously, requiring no external power source or manual intervention. They depend exclusively on inherent natural forces and the fundamental principles of reactor physics, such as gravity, natural convection, and phase changes, to manage, alleviate, and avert the release of radioactive materials into the environment during accident scenarios like a loss-of-coolant accident (LOCA). PSSs are already integrated into such operating commercial reactors as the Advanced Pressurized Reactor-1000 MWe (AP1000) and the Water-Water Energetic Reactor-1200 MWe (WWER-1200) are adopted in most of the upcoming small modular reactor (SMR) designs. Examples of water-cooled SMR PSSs are the passive emergency core-cooling system (ECCS), passive containment cooling system (PCCS), and passive decay-heat removal system, the designs of which vary based on reactor system-design requirements. However, understanding the accident-event progression and phases of a LOCA is pivotal for adopting a specific PSS for a new SMR design. This study covers the accident-event progression for direct vessel injection (DVI) small-break loss-of-coolant accident (SB-LOCA), associated physics phenomena, knowledge gaps, and important figures of merit (FOMs) that may need to be evaluated and assessed to validate thermal-hydraulics models with an available experimental dataset to support new SMR design and development.
The Path to Ultimate Heat Sink Device (PTUHS) is a passive safety system that utilizes a radiative heat transfer valve to control the rate at which heat is removed from a nuclear reactor pressure vessel (RPV) and dispersed into surrounding soil. The material selection for the PTUHS device is investigated, where the thermophysical properties are either maximized or minimized bases on what section of the PTUHS that material is being used for. Final recommendations of material choice are then presented. The heat transfer model of the PTUHS device is solved in ABAQUS, where a normal operating conditions and SCRAM conditions are solved. These temperature maps and heat flux of the system show the system's ability, where minimal heat is lost during normal operating conditions and system failure in a SCRAM scenario due to temperatures that were reached.
The Westinghouse Electric Company’s Advanced Passive Reactor (AP1000) is characterized by the incorporation of passive safety systems (PSSs) designed to ensure core cooling during transient events. The assessment of PSSs requires evaluation of their performance through a combination of experiments and simulations employing various thermal-hydraulic codes. In addition, detailed evaluation of PSSs for a specific reactor system transient analysis such as loss-of-coolant-accident analysis supports understanding representative integral effects test facility development and the further evolution model development and assessment process. Developing a reactor system code is a complex and time-consuming process that requires significant engineering expertise and effort. It can take several months to even years to complete in the early stages of reactor system design and analysis. However, this process can be expedited through the use of transient simulator models for similar reactor systems, which can be used for lesson learning and training purposes. This study uses the Personal Computer Transient Analyzer (PCTRAN) code. The main advantage of PCTRAN is its ease of use and ability to run faster than real time. This study presents the results obtained for a small-break loss-of-coolant accident (SBLOCA) for two breaks using the full version (licensed) of PCTRAN. The purpose of this investigation is to evaluate the overall system behavior during the postulated SBLOCA event as well as assess the capability of the PCTRAN code to reproduce the system response during transient events. The obtained results were compared with the Westinghouse NOTRUMP system code. The PCTRAN code proved to be reliable in predicting the qualitative behavior of the system in both transient cases. As for the system response, it was found that it is contingent on the activation time of the PSSs. The differences in reactor coolant system pressure between the two codes were attributed to the critical flow model and simplification of mass and energy balance. Despite PCTRAN’s limitations, it can still provide a reasonable prediction of various reactor parameters such as pressure, mass flow rate, and void fraction during a SBLOCA scenario. It is worth noting that PCTRAN currently employs a bulk approach similar to that of the Modular Accident Analysis Program (MAAP) and MELCOR codes. However, the upcoming version of PCTRAN will include an artificial intelligence–based detection and accident prevention system, as well as different models for different reactor components. Consequently, PCTRAN has the potential to be upgraded to match the system thermal-hydraulic codes of the U.S. Nuclear Regulatory Commission and become more widely used in cybersecurity to safeguard nuclear power plants from cyberattacks.
The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.
Ceramic high efficiency particulate air (HEPA) filter development program began at Lawrence Livermore National Laboratory (LLNL) over 20 years ago. Historical incidents motivated current safety systems at nuclear facilities. A ceramic filter that can survive a fire can provide robust, passive safety protection. Research has been conducted to improve the safety of nuclear facilities and to reduce operational and lifecycle costs, through ceramic filter technology that can survive fire conditions. Here, the research focused on applications in both new facilities as well as meeting operational requirements necessary to retrofit filters into existing DOE facilities. The research has developed multiple filter technologies spanning traditional HEPA filter materials to advanced manufacturing technologies (e.g., electrospinning, additive manufacturing, etc.). This communication will present highlights of selected development efforts for ceramic HEPA filter research, current state-of-the-art for ceramic filters, and future needs including technical, regulatory, and commercial efforts.
This code is designed to predict and analyze the decay heat generated in molten salt reactors (MSRs) using a hybrid approach that combines machine learning and segmented polynomial fitting. The accurate prediction of decay heat is essential for reactor safety and the optimization of spent fuel storage. The code operates through several key components: 1) Data Architecture: It incorporates a modular data architecture that handles various MSR-specific operational parameters such as power density, humidity content, and air ingress. These parameters are sampled using Sobol sequences to ensure comprehensive coverage of operational uncertainties. 2) Machine Learning Framework: The code employs a diverse set of machine learning models, including polynomial regression, decision trees, random forests, gradient boosting, support vector regression, k-nearest neighbors, multi-layer perceptrons, and symbolic regression. These models are trained to predict decay heat over a wide temporal range, from immediate shutdown up to 10,000 years. 3) Region-Optimized Training: The temporal domain is divided into multiple regions, each modeled separately to capture distinct decay heat characteristics across different time scales. This approach significantly improves the accuracy and interpretability of predictions. 4) Segmented Polynomial Interpretation (SPI): The SPI method translates machine learning predictions into piecewise polynomial equations. These equations are physically interpretable and can be directly integrated into existing engineering workflows and safety analyses. 5) Front-End Interfaces: The code includes both a Jupyter notebook interface for research development and a Streamlit web application for operational deployment. These interfaces allow users to interactively explore decay heat predictions, adjust operational parameters, and visualize results in real-time. 6) Applications: The framework supports various applications, including safety system validation and spent fuel container optimization. It enables real-time evaluation of worst-case decay heat scenarios, informing the design of passive safety systems and optimizing container designs for long-term storage. Overall, this code provides a robust, accurate, and user-friendly tool for predicting decay heat in MSRs, enhancing reactor safety, and optimizing spent fuel management.