Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pauling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dipole Field Effects on Ion Ejections from a Paul Ion Trap

Attempts at improving the quality of mass spectra obtained from a Paul trap mass spectrometer prompted an investigation of the effects of additional fields to supplement the primary rf quadrupole trapping field. Reported here are the results of the first in a series of tests that focuses on the application of a single dipole field to augment the trapping and subsequent ejections of ions stored within a Paul trap. Measurements are presented for a fixed quadrupole frequency with varying dipole frequencies. The presence of the dipole field during the quadrupole trapping phase causes ion ejections of single m/z species at discrete dipole frequencies. During the mass analysis phase, the varying dipole frequency produces a complex set of resonant structures that impact ejection time (mass range), as well as mass spectral peak intensity and width

dipole↗

Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer

Miniature gas chromatography (GC) and miniature mass spectrometry (MS) instrumentation has been developed to identify and quantify the chemical compounds present in complex mixtures of gases. The design approach utilizes micro-GC components coupled with a Paul quadrupole ion trap (QIT) mass spectrometer. Inherent to the system are high sensitivity, good dynamic range, good QIT resolution, low GC flow-rates to minimize vacuum requirements and the need for consumables; and the use of a modular approach to adapt to volatile organic compounds dissolved in water or present in sediment. Measurements are reported on system response to gaseous species at concentrations varying over four orders of magnitude. The ability of the system to deal with complicated mixtures is demonstrated, and future improvements are discussed. The GC/QIT system described herein has a mass, volume and power that are, conservatively, one-twentieth of those of commercial off-the-shelf systems. Potential applications are to spacecraft cabin-air monitoring, robotic planetary exploration and trace-species detection for residual gas analysis and environmental monitoring.

Miniaturization/instrumentation/methods↗

Paul Bert

This biographical article on Paul Bert highlights his studies on the physiology of respiration and barometric pressure and, in particular his contributions to the understanding of hypoxia, hyperoxia and anesthesia.

Colin, J.↗

Dynamics of charged particles in a Paul radio-frequency quadrupole trap

A molecular-dynamics simulation of hundreds of ions confined in a Paul trap has been performed. The simulation includes the trapped particles' micromotion and interparticle Coulomb interactions. A random walk in velocity was implemented to bring the secular motion to a given temperature which was numerically measured. When the coupling Gamma is large the ions from concentric shells which undergo a quadrupole oscillation at the RF frequency, while the ions within a shell form a 2D hexagonal lattice. Ion clouds at 5 mK show no RF heating for q(z) less than about 0.6, whereas rapid heating is seen for qz = 0.8.

Prestage, J. D.↗

An infrared astronomer's early vision of airborne astronomy: Paul Merrill 1920

The first published paper by a professional, research astronomer which discussed airborne astronomy from airplanes was by Paul W. Merrill. In it he proposed some of the types of observations which might be made, looking up at astronomical objects in the sky. This paper describes Merrill's paper, his education, training and subsequent career, and a few other aspects of the early history of airborne astronomy.

Osterbrock, Donald E.↗

STS-113 Crew Interviews: Paul Lockhart, Pilot

STS-113 Pilot Paul Lockhart is seen during this preflight interview, where he gives a quick overview of the mission before answering questions about his inspiration to become an astronaut and his career path. Lockhart outlines his role in the mission in general, and specifically during the docking and extravehicular activities (EVAs). He describes the primary mission payload (the P1 truss) and the crew transfer activities (Expedition 6 crew will replace the Expedition 5 Crew). Lockhart discusses the planned EVAs in detail and mentions what supplies will be left for the resident crew of the International Space Station (ISS). He ends with his thoughts about the importance of the ISS as the second anniversary of continuous human occupation of the space station approaches.

Source record↗

STS-111 Crew Interviews: Paul Lockhart, Pilot

STS-111 Pilot Paul Lockhart is seen during this preflight interview, where he gives a quick overview of the mission before answering questions about his inspiration to become an astronaut and his career path. He discusses the following mission goals: the crew transfer activities (the Expedition 5 crew is replacing the Expedition 4 crew on the International Space Station (ISS)), the delivery of the payloads which includes the Mobile Remote Servicer Base System (MBS), and the planned extravehicular activities (EVAs) which include attaching the MBS to the ISS and repairing the station's robot arm. He describes in-flight procedures for launch, reentry and docking with the ISS. He ends with his thoughts on the role of international cooperation in building and maintaining ISS.

Source record↗

Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

GC/MC miniature mass spectrometry MEMS↗

A unifying comparison of nearly scatter free transport models

Gombosi et al. (1993) recently derived a modified telegrapher's equation for charged particle transport under the influence of isotropic scattering. This equation obeys causality and disallows upstream diffusion for particles with random velocities smaller than the bulk flow velocity. The acausal diffusion equation was obtained to lowest order in the expansion of smallness prameters. The paper by Gombosi et al. (1993) prompted responses from Pauls et al. (1993) and Earl (1993). This paper is written to explain the differences between the methods, assumptions, and results of Gombosi et al. (1993), Pauls et al. (1993), and Earl (1993) and presents a new method of obtaining approximate solutions. It is shown that the assumptions used by Gombosi et al. (1993) and Pauls et al. (1993) are physically equivalent. In our solution method, the solution of the modified telegrapher's equation is obtained as the casual limit of solutions accurate to second order in the smallness parameter expansion. In order to investigate the coherent velocity, we have also developed `wavenumber eigenfunctions' which account for all the pitch angle dependence in our Boltzmann equation. Using truncation, Earl (1993) obtains approximations for the wavenumber dependence of the lowest two frequency modes, which correspond to two of the wavenumber eigenmodes. We find that a consequence of including only two wavenumber eigenmodes is that one obtains solutions which disobey causality at sufficiently short times. Furthermore, the coherent velocity of the two eigenmodes is strongly dependent on wavenumber and approaches the particle velocity in the limit of large wavenumber for both isotropic and anisotropic scattering processes. We conclude that Earl's (1993) solutions and solutions obtained using the new solution method implicitly assume weak acausality and reasonable behavior in the temporal regime, t less than 4 tau. The solutions are not strictly consistent with the behavior of the lowest two frequency modes but have similar behavior in the regime of low wavenumber.

Schwadron, N. A.↗