Search NASASearch

SEARCH · Search NASA

Results for “Performance Measurement Techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Versatile Cell Design for Molten Fluoride Salt Spectroscopy: Investigating Metal-Ion Speciation in Molten Fluoride Salts

Fluoride-based molten salts are widely used in industrial applications including aluminum production, thermal energy storage, optical crystal growth, and advanced nuclear reactor designs. Despite the wide range of uses, fundamental understandings of coordination chemistry and methods for probing molten fluorides are scarce, likely due to the difficulty of probing fluoride melts with spectroscopic techniques. Performing spectroscopic measurements of fluoride-based salts is challenging due to the highly corrosive nature of these salts, which can degrade many common optical materials. Here, in this work, we present a versatile optical cell design that enables spectroscopic measurements of corrosive melts. This innovative cell design overcomes the challenges posed by the corrosive nature of the salts, allowing for an accurate and consistent spectroscopic analysis. This work reports temperature-dependent absorption measurements for Co 2+ , Ni 2+ , and Cr 3+ analytes in LiF-NaF-KF eutectic salt (i.e., FLiNaK), which are common corrosion products originating from structural alloys in molten-fluoride handling. Absorption spectra were used to understand interactions of these analytes with FLiNaK, particularly ligand field coordination. The analysis of absorption spectra was complemented by structural analyses using ab initio molecular dynamics (AIMD) simulations, providing deeper insights into the behavior of the analytes in FLiNaK. Our findings indicate that the analytes studied in this work exist in octahedral or near-octahedral coordination states that remain stable across the temperature range of 500–600 °C. This work not only highlights an applied solution to performing optical spectroscopy in corrosive, high-temperature melts but also provides important fundamental insight on coordination behavior of transition-metal species in molten fluorides.

Fluoride salt spectroscopy

An Internal Digital Image Correlation Technique for High-Strain Rate Dynamic Experiments

Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.

36 MATERIALS SCIENCE

A machine-learning approach to measure 3D sample properties from 2D Transmission Electron Microscopy images

Transmission Electron Microscopy (TEM) is a powerful tool for the characterization of materials at the nanoscale; however, its inherent two-dimensional (2D) nature poses significant challenges to accurately measure three-dimensional (3D) properties. We introduce a supervised machine-learning model that predicts 3D structural information, such as sample thickness and curvature, from a series of conventional 2D TEM images. The model, a U-Net convolutional neural network, is trained on a large synthetic dataset generated from dynamical diffraction simulations that model TEM’s complex, nonlinear image formation, accounting for sample thickness and curvature. This physically realistic framework enables exploration of a broad parameter space impractical to sample experimentally. We demonstrate that the trained model has accurate predictions for experimental single-crystal silicon samples, achieving performance comparable to established measurement techniques. This work highlights the critical role of robust, simulation-based training in overcoming the limitations of real-world imaging artifacts and inconsistent sample geometries. By integrating machine learning with numerical simulations, we offer an efficient and scalable framework for quantitative TEM analysis, paving the way for more sophisticated 3D characterization of complex materials.

Dynamical diffraction

High temperature electrical property measurements of ceramics

Emerging applications in energy and aerospace systems require high quality data on the high temperature electrical properties of ceramics, particularly oxides, to guide material selection, design, and modeling. This presentation demonstrates the functionality of a specially designed sample fixture that enables electrical measurements to be conducted up to temperatures as high as 1600°C. Utilizing the mismatch in the coefficient of thermal expansion between two materials, a purely mechanical method for establishing electrical contact in the van der Pauw geometry is used to measure the bulk resistivity of ceramic materials. Measurements conducted on a number of common high temperature materials will be presented, including 20 mol % Gd-doped cerium oxide. Measurements are performed using multiple techniques and compared to literature values finding excellent agreement. The approach described in this work enables the van der Pauw method to be applied to many ceramic materials over a wide range of temperatures and environments.

Cann, David P.

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting (SC) circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in SC films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu–Shiba–Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

metal/substrate interlayer

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]

A Hermetic Package Technique for Multi-Functional Fiber Sensors through Pressure Boundary of Energy Systems Based on Glass Sealants

This paper presents a hermitic fiber sensor packaging technique that enables fiber sensors to be embedded in energy systems for performing multi-parameter measurements in high-temperature and strong radiation environments. A high-temperature stable Intrinsic Fabry–Perot interferometer (IFPI) array, inscribed by a femtosecond laser direct writing scheme, is used to measure both temperature and pressure induced strain changes. To address the large disparity in thermo-expansion coefficients (TECs) between silica fibers and metal parts, glass sealants with TEC between silica optical fibers and metals were used to hermetically seal optical fiber sensors inside stainless steel metal tubes. The hermetically sealed package is validated for helium leakages between 1 MPa and 10 MPa using a helium leak detector. An IFPI sensor embedded in glass sealant was used to measure pressure. The paper demonstrates an effective technique to deploy fiber sensors to perform multi-parameter measurements in a wide range of energy systems that utilize high temperatures and strong radiation environments to achieve efficient energy production.

Optics

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P

Identifying materials-level sources of performance variation in superconducting transmon qubits

The Superconducting Quantum Materials and Systems Center, a U. S. Department of Energy National Quantum Information Science Research Center, has conducted a comprehensive and coordinated study using superconducting transmon qubit chips with known performance metrics to identify the underlying materials-level sources of device-to-device performance variation. Following qubit coherence measurements, these qubits of varying base superconducting metals and substrates have been examined with various non-destructive and invasive material characterization techniques at Northwestern University, Ames National Laboratory, and Fermilab as part of a blind study. We find trends in variations of the depth of the etched substrate trench, the thickness of the surface oxide, and the geometry of the sidewall, which when combined, lead to correlations with the T1 lifetime across different qubits on the same chip. In addition, we provide a list of features that varied from device to device, for which the impact on performance requires further studies. Finally, we identify two low-temperature characterization techniques that may potentially serve as proxy tools for qubit measurements. These insights provide materials-oriented solutions to not only reduce performance variations across neighboring devices but also to engineer and fabricate devices with optimal geometries to achieve performance metrics beyond the state-of-the-art values.

Murthy, Akshay A. [Fermilab] (ORCID:00000001767768

Measurement of seasonal variations of the NSLS-II circumference and energy

Routine beam-based characterization of the NSLS-II storage ring indicated probable seasonal variations of the ring circumference and energy. We arranged regular direct measurements of the ring circumference during 2023 and compared the results with the archived data of the magnet and undulator settings. A clear correlation between the ring circumference and energy was observed. These seasonal variations of the ring energy are found to be the main reason for regular lattice corrections required to keep the machine performance stable for user operations. Finally, the measurement techniques and results are discussed in this article.

36 MATERIALS SCIENCE

Diagnosing inertial confinement fusion ignition

Abstract Fusion ignition by inertial confinement requires compression and heating of the fusion fuel to temperatures in excess of 5 keV and densities exceeding hundreds of g/cc. In August 2021, this scientific milestone was surpassed at the National Ignition Facility (NIF), when the Lawson criterion for ignition was exceeded generating 1.37MJ of fusion energy (Abu-Shawareb et al 2022 Phys. Rev. Lett. 129 075001), and then in December 2022 target gain >1 was realized with the production of 3.1MJ of fusion energy from a target driven by 2.0MJ of laser energy (Abu-Shawareb et al 2024 Phys. Rev. Lett. 132 065102). At the NIF, inertial confinement fusion research primarily uses a laser indirect drive in which the fusion capsule is surrounded by a high-Z enclosure (‘hohlraum’) used to convert the directed laser energy into a symmetric x-ray drive on the capsule. Precise measurements of the plasma conditions, x-rays, γ -rays and neutrons produced are key to understanding the pathway to higher performance. This paper discusses the diagnostics and measurement techniques developed to understand these experiments, focusing on three main topics: (1) key diagnostic developments for achieving igniting plasmas, (2) novel signatures related to thermonuclear burn and (3) advances to diagnostic capabilities in the igniting regime with a perspective toward developments for intertial fusion energy.

Moore, A. S. (ORCID:0000000221258882)

Stability evaluation and mitigation strategies in advanced tokamaks using 3D MHD spectroscopy

Multi-modal, active 3D MHD spectroscopy is applied in high-performance advanced tokamak scenarios to study their stability time evolution, revealing an intriguing dependence on both and . A tailored applied 3D field provides a 3D plasma response to extract the growth rate of the least stable mode. The estimated growth rate finds a decrease in stability when the minimum in the safety factor (q) passes through 2.0 and reveals inherent risks of crossing an additional rational surface at integer q min , even above the usual q = 1 sawtooth condition. Based on this result, the potential scenario in which q min ~ 2 can be safely crossed during a more stable lower β N phase was investigated, and the improved stability of this scenario is confirmed by the estimated growth rate. This shows that 3D MHD spectroscopy can offer insights into strategies for improving stability by identifying the vulnerable aspects of such scenarios. In addition, the method highlights its potential for instability avoidance by enabling early detection of multiple modes, even before magnetic coils can measure them. The measured growth rate by the 3D MHD spectroscopy shows its reliability by exhibiting a correlation with the programmed rises in plasma beta across various high β N and high q min discharges. In addition, this method is successfully applied during rapidly evolving I p ramp-up phases, a key part of the scenario development. By achieving reasonable growth rate measurements at high-performance scenario developments, this technique contributes to the development of advanced diagnostic tools for tokamak scenario stability, which will help identify an effective pathway to stable, high-performance scenarios.

Yang, S. M. [Princeton Plasma Physics Laboratory (

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle

Sound Velocity of Hematite up to 13 GPa

We performed acoustic measurements on polycrystalline hematite using ultrasonic interferometric techniques in a Kawai-type multi-anvil apparatus. The elastic moduli and their pressure derivatives were determined by fitting the experimental data to third-order finite strain equations, yielding: 𝐾 𝑆,0 = 214.8 (20) GPa, 𝐺 0 = 92.0 (2) GPa, 𝐾$^{′}_{S,0}$ = 5.70 (1), and 𝐺$^{′}_{0}$ = 0.88 (4). Modeling of the velocity profiles of hematite along hot and cold slab geotherms shows that compressional (V P ) and shear (V S ) wave velocities are 22%–24% and 53%–55% lower, respectively, compared to the Preliminary Reference Earth Model at the top of the lower mantle. Furthermore, these findings likely offer a potential explanation for the low-velocity anomalies associated with slab graveyards at the base of the lower mantle.

36 MATERIALS SCIENCE

X-ray Transient Absorption Spectroscopy Reveals Light Responses of Cobalt Centers in Co-Pi OER Catalytical Devices under Electrochemical Biases

Here, operando X-ray transient absorption measurements were successfully performed for the first time on the Co-Pi catalyst, confirming a photoreduction in Co-Pi under 400 nm blue light excitation. This provides key insights into spectroelectrochemical mechanistic studies of relevant oxygen evolution catalysts and guidance for photocatalysis using these metal oxides. Limiting blue-light exposure of these films should allow for better self-healing and higher turnover in photon-driven water oxidation. These results also demonstrate the importance of performing XTA measurements under operating conditions. Further development of this technique will allow for analysis of complex materials such as tethered molecules on surfaces and in complex device architectures to yield beneficial data for applied materials.

electrochemical cells

Error mitigated metasurface-based randomized measurement schemes

Estimating properties of quantum states via randomized measurements has become a significant part of quantum information science. In this paper, we design an innovative approach leveraging metasurfaces to perform randomized measurements on photonic qubits, together with error mitigation techniques that suppress realistic metasurface measurement noise. Through fidelity and purity estimation, we confirm the capability of metasurfaces to implement randomized measurements and the unbiased nature of our error-mitigated estimator. Our findings show the potential of metasurface-based randomized measurement schemes in achieving robust and resource-efficient estimation of quantum state properties. Published by the American Physical Society 2024

Ren, Hang (ORCID:0000000255448692)

A Flux-Tunable cavity for Dark matter detection

Developing a dark matter detector with wide mass tunability is an immensely desirable property, yet it is challenging due to maintaining strong sensitivity. Resonant cavities for dark matter detection have traditionally employed mechanical tuning, moving parts around to change electromagnetic boundary conditions. However, these cavities have proven challenging to operate in sub-Kelvin cryogenic environments due to differential thermal contraction, low heat capacities, and low thermal conductivities. Instead, we develop an electronically tunable cavity architecture by coupling a superconducting 3D microwave cavity with a DC flux tunable SQUID. With a flux delivery system engineered to maintain high coherence in the cavity, we perform a hidden-photon dark matter search below the quantum-limited threshold. A microwave photon counting technique is employed through repeated quantum non-demolition measurements using a transmon qubit. With this device, we perform a hidden-photon search and constrain the kinetic mixing angle to ${\varepsilon}< 8.2\times 10^{-15}$ in a tunable band from 5.672 GHz to 5.694 GHz. By coupling multimode tunable cavities to the transmon, wider hidden-photon searching ranges are possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS