Search NASA⌕ Search

SEARCH · Search NASA

Results for “Periodic Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A simple numerical method for evaluating heat dissipation from curved wires with periodic applied heating

In many situations, the dual-purpose heater/thermometer wires used in the three-omega method – one of the most precise and sensitive techniques for measuring the thermal conductivity of thin films and interfaces – must include bends and curves to avoid obstructions on the surface of a sample. Although the three-omega analysis assumes that the heating wire is infinitely long and straight, recent experimental work has demonstrated that in some cases curved-wire geometries can be used without introducing detectable systematic error. We describe a general numerical method that can be used to calculate the temperature of three-omega heating wires with arbitrary wire geometries. Furthermore, this method provides experimentalists with a simple quantitative procedure for calculating how large the systematic error caused by a particular wire asymmetry will be. We show calculations of two useful cases: a straight wire with a single bend of arbitrary angle and a wire that forms a circle. We find that the amplitude of the in-phase temperature oscillations near a wire that forms a circle differs from the prediction using the analytic straight-line source solution by <12%, provided that the thermal penetration depth is less than ten times the radius of curvature of the wire path. The in-phase temperature amplitude 1.5 wire widths away from a 90° bend in a wire is within 11% of the straight-line source prediction for all penetration depths greater than the wire width. Our calculations indicate that the straight-line source solution breaks down significantly when the wire bend angle is less than 45°.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thermal and hydraulic performance of volumetrically heated triply periodic minimal surface heaters

Advanced heat transfer surfaces, mainly Triply Periodic Minimal Surfaces (TPMSs) have great potential to increase heat transfer performance over traditional heat transfer surfaces due to their tortuous flow path and higher surface area-volume ratio. The emergence of additive manufacturing of nuclear fuel motivates experimental investigation of such advanced geometries in the context of a nuclear reactor core. Here, this study employed a novel method to explore the performance of gyroid and diamond TPMS geometries. Volumetrically heated heaters were additively manufactured from conductive polymer filament, and airflow was used to simulate the convective heat transfer from the core within a nuclear reactor. The mass flow and volumetric generation rates were varied, local Nusselt number correlations were obtained using embedded thermocouples to measure the solid and fluid temperature, and friction factor correlations were developed using differential pressure measurements. The gyroid TPMS presented a friction factor 1.5 times higher than the diamond TPMS and 90 times that of the rod bundle. TPMS geometries showed Nusselt numbers 8–10 times higher than that of the rod bundle, also maintaining colder internal temperatures, which suggested that they could sustain 250–275 % higher power density than the rod bundle for a given centerline temperature. Hence, having the potential to greatly increase the safety margins and power output of a nuclear reactor core with similar volume.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing particle-based thermal storage performance using optical methods for use in next generation concentrating solar power plants

Concentrating Solar Power (CSP) generation is an attractive option for low-emission power generation; however, the high costs of thermal storage associated with concentrating solar create a large barrier for their use and adaptation into modern life. Lowering their operation costs, while maintaining high thermal storage and transfer performance is essential. Solid particle-based heat exchange systems can reduce CSP cost but are often less efficient. Efforts to increase their performance have led to use of binary size particle mixes. Presented is an optical-based thermal analysis technique used to measure near-wall thermal conductivity of particle beds essential in determining their heat exchanger efficiency. Modulated Photothermal Radiometry is used to make dynamic temperature measurements, allowing for the extraction of the most relevant thermal properties like thermal conductivity, specific heat, and effusivity. The system uses a modulated laser source causing a damped periodic heat flux, resulting in a frequency and thermal property dependent surface temperature, of which is measured using radiometry. Lock-In techniques are used to extrapolate the amplitude of the signal. Plotting the amplitude against the root angular frequency allows for effusivity measurement by ratio to a known sample. Using specific heat measurements from literature and density measurements, the thermal conductivity of the particle mixes can be calculated. The simplicity of MPTR to probe through the depth of the bed is ideal for use in CSP for dynamic thermal performance monitoring.

Corona, Javier↗

Simulation of the supercritical CO 2 recompression Brayton power cycle with a high-temperature regenerator

The supercritical carbon dioxide (sCO 2 ) recompression Brayton cycle promises higher efficiency and lower capital cost than traditional steam Rankine power cycles. However, achieving high efficiency requires large, highly effective recuperators. Regenerators may be a low-cost alternative to printed circuit and micro-tube heat exchangers for recuperation in sCO 2 power cycles. Regenerators are a periodic heat exchanger in which thermal energy is extracted from the hot stream, stored in solid media, and then released to the cold stream at a later time. Fixed bed regenerators with valves to direct fluid are the preferred method for implementing regenerators in power cycles, but the inherently transient nature of these systems has not been characterized for this application. This study presents the simulation of a high-temperature regenerator within a 10 MWe sCO 2 recompression Brayton cycle. A transient, one-dimensional regenerator model presented in a previous study is used to simulate the regenerator. Dynamic heat exchanger models are also developed for the precooler, low-temperature recuperator, and primary heat exchanger, and the compressors and the turbine are modeled with off-design performance maps. We assess two regenerator-valve design options; one for fast switching, and one for reduced flow rate fluctuations. System simulation finds that both designs see significant fluctuations in turbomachinery flow rate, turbomachinery and system power, and regenerator discharge process outlet temperature. While designing the regenerator-valve subsystem for lower fluctuations is possible, the regenerator cold discharge temperature and net power still fluctuate by ±77.6°C and 6%, respectively. Increasing buffer volume is not effective at sufficiently reducing these fluctuations, but adding a packed bed in between the regenerator and the primary heat exchanger can reduce regenerator discharge process outlet temperature fluctuations to 6.4°C. Further reductions could be possible by increasing the size of this packed bed.

42 ENGINEERING↗

Observation of quasi-coherent density fluctuation in scrape-off layer enhancing boundary transport in high-βN hybrid plasmas on DIII-D

In this work, we report the observation of a quasi-coherent density fluctuation (QCF) by the Doppler backscattering system in the scrape-off layer (SOL) region of the DIII-D tokamak. This QCF is observed in high power, high performance hybrid plasmas with near double-null divertor (DND) shape during the electron cyclotron heating period. This mode is correlated with a steepened SOL density profile, and leads to significantly elevated particle and heat fluxes between ELMs. The SOL QCF is a long-wavelength ion-scale fluctuation (k θ ρ s ≈0.2-0.4 and k r ρ s ≈0.03), and propagates in the ion diamagnetic direction in the plasma frame. Its radial expanse is about 1.5–2 cm, well beyond the typical width of heat flux λ q on DIII-D. Also, the SOL QCF does not show any clear dependence on the effective SOL collisionality, and thus may raise issues on the control of plasma-material interactions in low collisionality plasmas in which the blob-induced transport is reduced. A linear simulation using BOUT++ with a 5-field reduced model is performed and compared with experimental observations. In simulation results, an interchange-like density perturbation can be driven by the SOL density gradient, and its peak location and the radial width of the density perturbation are in agreement with the experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving operational flexibility of integrated energy system with uncertain renewable generations considering thermal inertia of buildings

Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.

30 DIRECT ENERGY CONVERSION↗

Analysis of iron-chromium-aluminum samples exposed to accident conditions followed by quench in the QUENCH-19 experiment

The QUENCH-19 experiment was a first-of-its-kind full-bundle test simulating accident conditions followed by water quench on accident-tolerant fuel (ATF) cladding. Here, a type of FeCrAl(Y) alloy, B136Y3, was developed at Oak Ridge National Laboratory and tested at the Karlsruhe Institute of Technology using Kanthal APM corner rods, a shroud, and Kanthal AF spacer grids. Testing conditions were similar to those in QUENCH-15—which tested ZIRLO cladding behavior—so that B136Y3 and ZIRLO cladding could be compared. QUENCH-19 consisted of an initial pre-oxidation heating followed by a transient. Then, a maximum power hold, which was not present in QUENCH-15, was executed to extend the heating period for the FeCrAl(Y) rods. Finally, a rapid water quench was executed that was similar to emergency core coolant system (ECCS) actuation. Compared with the ZIRLO rods in QUENCH-15, the bundle in QUENCH-19 released significantly less H 2 (9.2 g vs. 47.6 g) and achieved a much lower maximum temperature (1455°C vs. 1880°C). Furthermore, no breakaway oxidation was observed in QUENCH-19. Metallographic mounts revealed that despite the symmetry of the setup, at elevations near the maximum temperature, cladding and thermocouples were heavily damaged, substantial melting and oxidation occurred, and the cladding underwent chemical interaction with the thermocouple sheaths. Additionally, the ZrO 2 spacers detrimentally interacted with the cladding, leading to mixed oxide debris and the full destruction of some rods. Additional failure was found in certain cooler rods that may have risen due to the high thermal expansion coefficient of FeCrAl alloys. This paper presents an analysis of this work, which suggests that FeCrAl cladding can chemically survive anticipated loss-of-coolant accident events followed by rapid ECCS quench if the correct geometry and core design are present.

36 MATERIALS SCIENCE↗

NOx mediated formation of ε – UO 3 during thermal decomposition of uranyl nitrate hexahydrate under static air conditions

The thermal decomposition of uranyl nitrate hexahydrate in air at temperatures of 650 – 800 °C is expected to yield α – U 3 O 8 through intermediate UO 3 phases. Here, n this study, Raman spectroscopy complimented by powder X-ray diffraction revealed the unexpected formation of ε – UO 3 as an accompanying phase during thermal decomposition of UNH at 700 °C under static air conditions. Experiments demonstrated that ε – UO 3 does not form during the initial ramp up stage nor during the high temperature heating period; but instead forms during the cooling stage between 250 – 400 °C. Additional experiments revealed that UNH initially decomposes through an amorphous UO 3 intermediate prior to α – U 3 O 8 formation. Attempts to bypass the U 3 O 8 precursor in the formation of ε – UO 3 were unsuccessful, supporting the necessity of U 3 O 8 (α – U 3 O 8 in this study) in the formation of ε – UO 3 . The observed phase evolution is proposed to result from the NOx species generated during UNH thermal decomposition, which create localized oxidizing conditions within the furnace under static air conditions. Furthermore, a predominantly phase pure ε – UO 3 was synthesized under static air conditions through the addition of an extra plateau at 250 °C during the cooling step. These findings demonstrate the importance of gas-phase chemistry and cooling conditions in uranium oxide phase evolution and provide additional insight into ε – UO 3 formation pathways.

Epsilon uranium trioxide↗

Optimization and Techno-Economic Comparison of Regenerators and Recuperators in sCO2 Recompression Brayton Cycles for Concentrating Solar Power Applications

Supercritical CO2 power cycles might be capable of providing the cost reductions and efficiency improvements necessary to reach concentrating solar power (CSP) cost targets, but require large, highly effective recuperators. Fixed-bed regenerators are a periodic heat exchanger that could be an effective yet low-cost alternative to these recuperators. This study presents a techno-economic comparison of regenerators and recuperators for a 100 MWe supercritical CO2 power cycle for CSP applications. We quantify the levelized cost of energy (LCOE) for the power plant with both types of heat exchangers, and explore sensitivity of LCOE to parameters such as CSP-specific capital costs, power cycle component capital costs, and regenerator valve replacements costs. Results indicate that the incumbent printed circuit heat exchangers achieve the lowest LCOE, unless the upper extreme of PCHE capital cost and lower extremes of regenerator and valve capital and O&M costs are realized. Sensitivity analysis also illustrates that the primary heat exchanger cost is the most influential of power cycle components, and that CSP component capital cost is more influential than power cycle capital costs. This illustrates the importance of reducing the cost of heliostats, receivers, and thermal energy storage for achieving CSP LCOE targets.

OTHER INSTRUMENTATION,SOLAR ENERGY↗

Smart building HVAC control challenge: experience and solutions from the ADRENALIN project

A smart building HVAC control competition crowdsourced and compared algorithms on fair and equal ground using the standardized BOPTEST framework. The competition attracted 138 participants, but only 9% submitted valid solutions for the final stage, highlighting the complexity of advanced HVAC control design. The winning solutions showed significant potential to reduce energy use and cost by shifting demand, without compromising occupant comfort. Across scenarios, thermal energy cost reductions of 36–76% relative to a baseline, were achieved. In peak heat periods, the cost reduction leveraged limited energy use reduction (0–15%), but more significant energy price reduction (34–62%). This shows smart controls' ability to avoid as much as possible consumption during the morning peak hours, when spot prices are tendentially the highest. Hosting the competition has highlighted challenges in creating competitions that both are fair and promotes solutions that are transferable to real life implementation.

BOPTEST↗

MESOSCALE THERMAL TRANSPORT MEASUREMENTS OF MULTI-PHASE AND POROUS NUCLEAR FUELS USING A SQUARE-WAVE PULSE THERMOREFLECTANCE TECHNIQUE

The safe and efficient operation of nuclear reactors require accurate knowledge of peak temperatures in the fuel assemblies. The temperature profiles are governed by the thermal transport properties of the fuel, namely the thermal conductivities (k) and thermal diffusivities (D). These values can be very difficult to measure as they are known to vary considerably from the measured bulk values of the fresh fuel, and quickly degrade with increasing burnup [1 -3] . Laser-based techniques have been effectively used for non-destructive and non-contact thermal transport measurements of a wide variety of materials, including nuclear materials [4-6] that would otherwise prove too hazardous or difficult to measure otherwise. In this study, a new thermoreflectance technique known as square-pulse transient thermoreflectance (SPTR) is described and used to determine the mesoscale thermal diffusivity of both uranium sesquisilicide (U3Si2) and uranium nitride (UN) phases in a composite fuel with micron level spatial resolution [7]. This technique employs a rapid train of square-wave pulses from an excitation laser to create a periodic heat flux on a gold coated sample surface. Surface adsorption results in transient film temperatures and hence rapid fluctuations in thermoreflectance that can be measured via a detection laser coupled with a digital oscilloscope. The lasers are coaxially focused on the sample surface, allowing for a sample measurement area of a single convolved laser spot size (~2 µm). A sensitivity analysis was conducted to identify key measurement parameters of this technique using reference materials with a range of thermal conductivities comparable to those of both ceramic, composite, and metal nuclear fuel types (1.4 – 27.2 W/m-K). The reference materials were measured using the new technique as well as a spatial-domain thermoreflectance technique (SDTR) previously reported for a comparison [8]. Additionally, measurements of several U3Si2 and UN phase regions of a polished UN/U3Si2 (70/30 vol.%) sample were taken, and the resulting calculated D values are reported, with both techniques showing excellent agreement between samples. This technique was used to scan a multiphase region at 5 micron increments to generate a local diffusivity map, demonstrating the utility of the techniques for measuring thermal transport properties in specimens with precipitates and secondary phases. Furthermore, the technique is currently being applied to measure thermal properties of Fast Flux Test Reactor (FFTR) irradiated metal fuel specimens whose porous microstructure make it very difficult to measure using other techniques. Comparison of the local scale measurements are compared with the pre-irradiated fuel samples to show the degradation of thermal transport in fuels due to pores from fission gas bubbles and other irradiation induced defects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimization of Triply Periodic Minimal Surface Heat Exchanger to Achieve Compactness, High Efficiency, and Low-Pressure Drop

With advancements in additive manufacturing (AM) techniques, high-quality triply periodic minimal surface (TPMS) structures can now be produced. TPMS walled heat exchangers (HX) hold significant potential for industrial applications and are receiving increasing attention. This paper explores the impact of various TPMS design variables on flow and thermal performance to optimize TPMS heat exchangers for compactness, high efficiency, and low pressure drop. The design variables examined include the type of TPMS lattice, unit cell size, wall thickness, aspect ratio, TPMS orientation, and equivalent thickness. The study reveals that the flow and heat transfer performance of TPMS structures are significantly affected by these design variables. For the Gyroid, Diamond, and SplitP lattices, performance is nearly identical when the surface-to-volume ratio is kept constant. The average velocity of the fluid in the TPMS HX should be 0.3 m/s. The corresponding Re is between 300~800. Thin wall thickness, small equivalent thickness, and flat lattice configurations can significantly reduce pressure drop while maintaining the overall heat transfer coefficient. Additionally, the angle between the flow direction and TPMS orientation can increase pressure drop. Three aluminum heat exchangers were successfully printed using an AM machine, and testing results are comparable with theoretical prediction.

42 ENGINEERING↗

A numerical study of ignition and flame development characteristics in GCI combustion using large eddy simulations and chemical explosive mode analysis

Here, this work investigates the ignition and flame development processes of low reactivity fuel combustion under compression ignition conditions based on the large eddy simulation approach. The chemical explosive mode analysis (CEMA) is employed to characterize the local combustion features, including gas-liquid fuel zone, auto-ignition, diffusion-assisted, extinction, cool flame and post-ignition zone, among which auto-ignition and post-ignition are found to play a key role in the overall heat release process. The local flame propagation modes in gasoline compression ignition (GCI) are determined by quantifying the relative magnitude of diffusion/chemistry at a representative progress variable in the pre-ignition zone. The results show that autoignition fronts and deflagration waves exist simultaneously in the ignition and intense high temperature heat release (HTHR) stages, but autoignition fronts dominate. In addition, the chemical kinetic processes of four heat release periods are analyzed. The heat release during the ignition period is found to be dominated by the reactions CH 3 + H (+M) <=> CH 4 (+M) and CH 3 CHO + H <=> CH 2 CHO + H 2 . The reaction CH 2 OH + OH <=> CH 2 O + H 2 O always plays an important role in the heat releases during the other three combustion stages including intense HTHR, moderate HTHR and post-combustion.

33 ADVANCED PROPULSION SYSTEMS↗

Contrasting effects of lake breeze and urbanization on heat stress in Chicago metropolitan area

This study used the latest Weather Research and Forecasting (WRF) model coupled with multi -layer urban canopy models to investigate contrasting effects from urbanization and lake breeze on summer heat stress over the Chicago metropolitan area (CMA). Comparisons between the model and in situ observations show that this coupled modeling system better captures urban locations' diurnal pattern of surface air temperature, skin temperature and relative humidity, with root mean square error reduced from 1.58 to 1.80 degrees C to 1.14-1.31 degrees C, 3.11-3.55 degrees C to 1.81-2.21 degrees C, and 10.73-11.35% to 7.84-8.60%, respectively, compared to WRF without coupling the urban canopy models. Two sensitivity experiments were conducted to isolate the influence of lake breeze and urbanization: one replaced the urban land use with cropland over the CMA, and the other filled all of Lake Michigan with cropland. Three different heat stress indices were computed to assess the uncertainties of heat stress response to changes in air temperature, relative humidity, and wind conditions. Results show that, when the lake has the largest cooling effect on air temperature, it also increases the relative humidity the most, and vice versa for urban warming and drying effects. Urbanization intensifies heat stress at night, and extends the heat caution period by up to 4 h over inland urban grids; the lake breeze relieves heat stress during afternoon (when the heat stress is the worst), and shortens the heat caution period by 1-3 h over inland urban grids and 3-4 h over coastal urban grids. In conclusion, the intensification of heat stress over the CMA due to urbanization is more than four times greater than the reduction from the lake breeze in the late afternoon and evening.

54 ENVIRONMENTAL SCIENCES↗

Design, optimization, and validation of a triply periodic minimal surface based heat exchanger for extreme temperature applications

Heat exchanger (HX) innovation offers potential for significant improvements in energy efficiency for a host of applications including but not limited to aviation and power generation cycles. Triply Periodic Minimal Surfaces (TPMS) have received significant attention in recent years due to their incredibly high surface area density, which makes them very attractive from a heat transfer point of view. Recent efforts have largely focused on thermal-hydraulic characterization of the many available TPMS and the testing of small-scale HX prototypes. However, practical implementation remains largely unexplored, partially due to the extreme computational cost associated with accurately simulating these complex structures. In this work, we present the design, simulation, and optimization of a TPMS-HX for high temperature (900 °C) and pressure (25 MPa) applications. Detailed analysis of HX sub-sections is conducted to define the smallest repeatable section which may be used to characterize the thermal-hydraulic performance of the entire HX, enabling rapid design and iteration with significantly reduced computational cost. Compared to preliminary results for a water-to-water experiment, calibrated heat transfer and pressure drop predictions were within ±5 % and ±10 %, respectively. Optimization results show a 10x increase in volumetric power density over the initial design, which is verified against a parametric exhaustive search of the HX design space. Furthermore, it was found that reducing the unit cell hydraulic diameter cell plays the largest role in increasing heat transfer, increasing the surface area density and enabling a more compact and efficient HX.

42 ENGINEERING↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MHD-induced beta limits in the Large Helical Device

Using the extended-magnetohydrodynamics code, M3D-C1, we perform a systematic numerical study of the effect of externally applied heating on the achievable plasma beta in a ten field-period heliotron. Heat sources of varying intensity are applied to a vacuum magnetic field that is representative of the standard configuration of the Large Helical Device, with R 0 = 3.66 m, where R 0 is the radial position of the magnetic axis in vacuum. As the system is driven to a state that is unstable to low-n magnetohydrodynamic (MHD) modes, nonlinear mode interactions lead to the formation of chaotic magnetic fields. With sufficiently strong heating, a collapse of the electron temperature profile is observed. This demonstrates the necessity of simulating the self-consistent evolution of plasma profiles, without imposing assumptions on the structure of the magnetic field, to accurately determine transport properties in stellarator plasmas. It also highlights the value of these advanced simulation capabilities for accelerating the development of high-performance stellarator operating scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗