Search NASA⌕ Search

SEARCH · Search NASA

Results for “Periscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope

An Infrared imaging Video Bolometer (IRVB) diagnostic is currently being used in the Large Helical Device (LHD) for studying the localization of radiation structures near the magnetic island and helical divertor X-points during plasma detachment and for 3D tomography. This research demands high signal to noise ratio (SNR) and sensitivity to improve the temporal resolution for studying the evolution of radiation structures during plasma detachment and a wide IRVB field of view (FoV) for tomography. Introduction of an infrared periscope allows achievement of a higher SNR and higher sensitivity, which in turn, permits a twofold improvement in the temporal resolution of the diagnostic. Higher SNR along with wide FoV is achieved simultaneously by reducing the separation of the IRVB detector (metal foil) from the bolometer's aperture and the LHD plasma. Altering the distances to meet the aforesaid requirements results in an increased separation between the foil and the IR camera. This leads to a degradation of the diagnostic performance in terms of its sensitivity by 1.5-fold. Using an infrared periscope to image the IRVB foil results in a 7.5-fold increase in the number of IR camera pixels imaging the foil. This improves the IRVB sensitivity which depends on the square root of the number of IR camera pixels being averaged per bolometer channel. Despite the slower f-number (f/# = 1.35) and reduced transmission (τ{sub 0} = 89%, due to an increased number of lens elements) for the periscope, the diagnostic with an infrared periscope operational on LHD has improved in terms of sensitivity and SNR by a factor of 1.4 and 4.5, respectively, as compared to the original diagnostic without a periscope (i.e., IRVB foil being directly imaged by the IR camera through conventional optics). The bolometer's field of view has also increased by two times. The paper discusses these improvements in apt details.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Endovascular Treatment of a Symptomatic Thoracoabdominal Aortic Aneurysm by Chimney and Periscope Techniques for Total Visceral and Renal Artery Revascularization

Conventional endovascular therapy of thoracoabdominal aortic aneurysm with involving visceral and renal arteries is limited by the absence of a landing zone for the aortic endograft. Solutions have been proposed to overcome the problem of no landing zone; however, most of them are not feasible in urgent and high-risk patients. We describe a case that was successfully treated by total endovascular technique with a two-by-two chimney-and-periscope approach in a patient with acute symptomatic type IV thoracoabdominal aortic aneurysm with supra-anastomotic aneurysm formation involving the renal and visceral arteries and a pseduaneurismatic sac localized in the left ileopsoas muscle.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deploying the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Score-P: A Joint Performance Measurement Run-Time Infrastructure for Periscope, Scalasca, TAU, and Vampir.

This paper gives an overview about the Score-P performance measurement infrastructure which is being jointly developed by leading HPC performance tools groups. It motivates the advantages of the joint undertaking from both the developer and the user perspectives, and presents the design and components of the newly developed Score-P performance measurement infrastructure. Furthermore, it contains first evaluation results in comparison with existing performance tools and presents an outlook to the long-term cooperative development of the new system.

Application Execution↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved spatial calibration for the CXRS system on EAST

A Charge eXchange Recombination Spectroscopy (CXRS) diagnostic system has been developed to measure profiles of ion temperature and rotation since 2014 on EAST. Several techniques have been developed to improve the spatial calibration of the CXRS diagnostic. The sightline location was obtained by measuring the coordinates of three points on each sightline using an articulated flexible coordinate measuring arm when the vessel was accessible. After vacuum pumping, the effect of pressure change in the vacuum vessel was evaluated by observing the movement of the light spot from back-illuminated sightlines on the first wall using the newly developed articulated inspection arm. In addition, the rotation of the periscope after vacuum pumping was derived by using the Doppler shift of neutral beam emission spectra without magnetic field. Combining these techniques, improved spatial calibration was implemented to provide a complete and accurate description of the EAST CXRS system. Due to the effects of the change of air pressure, a ∼0.4° periscope rotation, yielding a ∼20 mm movement of the major radius of observation positions to the lower field side, was derived. Results of Zeeman splitting of neutral beam emission spectra with magnetic field also showed good agreement with the calibration results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of imaging bolometers for magnetic fusion reactors (invited)

Imaging bolometers utilize an infrared (IR) video camera to measure the change in temperature of a thin foil exposed to the plasma radiation, thereby avoiding the risks of conventional resistive bolometers related to electric cabling and vacuum feedthroughs in a reactor environment. A prototype of the IR imaging video bolometer (IRVB) has been installed and operated on the JT-60U tokamak demonstrating its applicability to a reactor environment and its ability to provide two-dimensional measurements of the radiation emissivity in a poloidal cross section. In this paper we review this development and present the first results of an upgraded version of this IRVB on JT-60U. This upgrade utilizes a state-of-the-art IR camera (FLIR/Indigo Phoenix-InSb) (3-5 {mu}m, 256x360 pixels, 345 Hz, 11 mK) mounted in a neutron/gamma/magnetic shield behind a 3.6 m IR periscope consisting of CaF{sub 2} optics and an aluminum mirror. The IRVB foil is 7 cmx9 cmx5 {mu}m tantalum. A noise equivalent power density of 300 {mu}W/cm{sup 2} is achieved with 40x24 channels and a time response of 10 ms or 23 {mu}W/cm{sup 2} for 16x12 channels and a time response of 33 ms, which is 30 times better than the previous version of the IRVB on JT-60U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

C-III flow measurements with a coherence imaging spectrometer

This work describes a coherence imaging spectrometer capable of making spatially resolved CIII flow measurements in the DIII-D lower divertor. The spectrometer exploits a periscope view of the plasma to produce line-of-sight averaged velocity measurements of CIII. From these chord averaged flow measurements, a 2D poloidal cross section of the CIII flow is tomographically reconstructed. Details of the diagnostic setup, acquired data, and data analysis will be presented, along with prospects for future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast imaging diagnostics on the C-2U advanced beam-driven field-reversed configuration device

The C-2U device employed neutral beam injection, end-biasing, and various particle fueling techniques to sustain a Field-Reversed Configuration (FRC) plasma. As part of the diagnostic suite, two fast imaging instruments with radial and nearly axial plasma views were developed using a common camera platform. To achieve the necessary viewing geometry, imaging lenses were mounted behind re-entrant viewports attached to welded bellows. During gettering, the vacuum optics were retracted and isolated behind a gate valve permitting their removal if cleaning was necessary. The axial view incorporated a stainless-steel mirror in a protective cap assembly attached to the vacuum-side of the viewport. For each system, a custom lens-based, high-throughput optical periscope was designed to relay the plasma image about half a meter to a high-speed camera. Each instrument also contained a remote-controlled filter wheel, set between shots to isolate a particular hydrogen or impurity emission line. The design of the camera platform, imaging performance, and sample data for each view is presented.

43 PARTICLE ACCELERATORS↗

Beryllium Use in the Advanced Test Reactor

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) began operation in 1967. It makes use of a unique serpentine fuel core design and a beryllium reflector. Reactor control is achieved with rotating beryllium cylinders to which have been fastened plates of hafnium. Over time, the beryllium develops rather high helium content because of nuclear transmutations and begins to swell. The beryllium must be replaced at nominally 10-year intervals. Determination of when the replacement is made is by visual observation using a periscope to examine the beryllium surface for cracking and swelling. Disposition of the irradiated beryllium was once accomplished in the INL’s Radioactive Waste Management Complex, but that is no longer possible. Among contributing reasons are high levels of specific radioactive contaminants including transuranics. The INL is presently considering disposition pathways for this irradiated beryllium, but presently is storing it in the canal adjacent to the reactor. Numerous issues are associated with this situation including (1) Is there a need for ultra-low uranium material? (2) Is there a need to recover tritium from irradiated beryllium either because this is a strategic material resource or in preparation for disposal? (3) Is there a need to remove activation and fission products from irradiated beryllium? (4) Will there be enough material available to meet requirements for research reactors (fission and fusion)? In this paper will be discussed the present status of considerations on these issues.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigating the possibility of a monitoring fast ion diagnostic for ITER

In burning plasma fusion devices, fast ion transport plays a central role in the performances of the machines. Moreover the losses of energetic particles might cause severe damages on plasma facing components. Therefore real time measurements of fast ion transport would provide valuable information for safe and reliable plasma operations. In this paper, we examine the feasibility of a monitoring system based on active charge exchange recombination spectroscopy making use of the 0.5 MeV/amu ITER heating neutral beams for detecting fast {sup 4}He{sup +2} (alphas) particles in ITER plasmas. There are two time scales relevant to fast ion dynamics: the first is the slowing down time of the distribution function which is of the order of 1 s, and the second is the time scale of burstlike transport events such as collective Alfven mode excitations, which--for typical ITER plasma parameters--can be as low as 0.2-1 ms. To detect such fast events a broadband high-throughput spectrometer is needed, while for the reconstruction of the alpha velocity distribution function a higher resolution spectrometer and longer integration time are necessary. To monitor a spatial redistribution of fast particles due to the propagation of the instability, it is proposed to use a limited number of spatial channels, looking at the charge exchange He II spectra induced by the heating beams, whose energy matches the slowing down energies of fast particles. The proposal is to share the motional stark effect periscope on equatorial port 3 [A. Malaquias et al., Rev. Sci. Instrum. 75, 3393 (2004)] adding additional fibers and suitable instruments. A signal to noise ratio of 5 could be achieved with a spatial resolution of a/15 and a time resolution of 5 ms, in a broad spectral band of 100 A, corresponding to the spectral broadening of the line emitted by alpha particles with energies {delta}E{<=}1.5 MeV. Fast H and D ion populations created by heating neutral beam or ion cyclotron resonance heating are expected to produce significantly lower charge exchange signal levels and can only be monitored on substantially longer time scales as it is expected because of the strong energy difference with respect to the heating neutral beam and the consequently low charge exchange cross sections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ion transport during applied 3D magnetic perturbations on DIII-D

In this paper, measurements show fast ion losses correlated with applied three-dimensional (3D) fields in a variety of plasmas ranging from L-mode to resonant magnetic perturbation (RMP) edge localized mode (ELM) suppressed H-mode discharges. In DIII-D L-mode discharges with a slowly rotating $n=2$ magnetic perturbation, scintillator detector loss signals synchronized with the applied fields are observed to decay within one poloidal transit time after beam turn-off indicating they arise predominantly from prompt loss orbits. Full orbit following using M3D-C1 calculations of the perturbed fields and kinetic profiles reproduce many features of the measured losses and points to the importance of the applied 3D field phase with respect to the beam injection location in determining the overall impact on prompt beam ion loss. Modeling of these results includes a self-consistent calculation of the 3D perturbed beam ion birth profiles and scrape-off-layer ionization, a factor found to be essential to reproducing the experimental measurements. Extension of the simulations to full slowing down timescales, including fueling and the effects of drag and pitch angle scattering, show the applied $n=3$ RMPs in ELM suppressed H-mode plasmas can induce a significant loss of energetic particles from the core. With the applied $n=3$ fields, up to 8.4% of the injected beam power is predicted to be lost, compared to 2.7% with axisymmetric fields only. These fast ions, originating from minor radii $\rho >0.7$ , are predicted to be primarily passing particles lost to the divertor region, consistent with wide field-of-view infrared periscope measurements of wall heating in $n=3$ RMP ELM suppressed plasmas. Edge fast ion ${{\text{D}}_{\alpha}}$ (FIDA) measurements also confirm a large change in edge fast ion profile due to the $n=3$ fields, where the effect was isolated by using short 50 ms RMP-off periods during which ELM suppression was maintained yet the fast ion profile was allowed to recover. Finally, the role of resonances between fast ion drift motion and the applied 3D fields in the context of selectively targeting regions of fast ion phase space is also discussed.

3D magnetic perturbations↗

Atomically Bonded Transparent Superhydrophobic Coatings

Maintaining clarity and avoiding the accumulation of water and dirt on optically transparent surfaces such as US military vehicle windshields, viewports, periscope optical head windows, and electronic equipment cover glasses are critical to providing a high level of visibility, improved survivability, and much-needed safety for warfighters in the field. Through a combination of physical vapor deposition techniques and the exploitation of metastable phase separation in low-alkali borosilicate, a novel technology was developed for the fabrication of optically transparent, porous nanostructured silica thin film coatings that are strongly bonded to glass platforms. The nanotextured films, initially structurally superhydrophilic, exhibit superior superhydrophobicity, hence antisoiling ability, following a simple but robust modification in surface chemistry. The surfaces yield water droplet contact angles as high as 172°. Moreover, the nanostructured nature of these coatings provides increased light scattering in the UV regime and reduced reflectivity (i.e., enhanced transmission) over a broad range of the visible spectrum. In addition to these functionalities, the coatings exhibit superior mechanical resistance to abrasion and are thermally stable to temperatures approaching 500°C. The overall process technology relies on industry standard equipment and inherently scalable manufacturing processes and demands only nontoxic, naturally abundant, and inexpensive base materials. Such coatings, applied to the optical components of current and future combat equipment and military vehicles will provide a significant strategic advantage for warfighters. The inherent self-cleaning properties of such superhydrophobic coatings will also mitigate biofouling of optical windows exposed to high-humidity conditions and can help decrease repair/replacement costs, reduce maintenance, and increase readiness by limiting equipment downtime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mapping Benthic Habitat Conditions and Seafloor Deposits using Sediment Profile Imaging and a Semiautomated Image Processing System

Objectives/Scope: Sediment profile imaging (SPI) technology characterizes in situ physical, geochemical, and biological seafloor features. SPI was required by Mexico’s Agency for Safety, Energy, and Environment in 2017 for environmental baseline surveys (EBS) of oil lease blocks in the southern Gulf of Mexico. Because of its ability to provide information on benthic community health and the distribution of very thin (down to the centimeter scale) layers of deposited materials, SPI technology is highly effective for mapping drill cuttings or drilling muds released around wellheads during exploration or production and documenting their ecological impacts. SPI technology has not been widely used in the oil and gas industry for EBS or other monitoring activities. A primary objective of this work is to improve the transparency and consistency of the SPI data generation and data management process. Methods, Procedures, Process: The SPI camera works like an inverted periscope and obtains an undisturbed 21x15-cm cross-sectional image of the upper sediment column. The camera is internally powered and can be deployed rapidly from a standard winch in depths to 4,000 m. Many stations can be sampled in a single day by “pogo-sticking” across a survey area. Sediment grain size, penetration depth, surface boundary roughness, natural and anthropogenic depositional layers, depth of the oxidized surface sediment layer, maximum biogenic mixing depth, and infaunal successional stage can be directly measured at sea or immediately following the cruise. Final SPI data sets can be provided within a few weeks of the survey. Results, Observations, Conclusions: Details on the features measured in SPI images and the underlying interpretive paradigms are presented. To standardize the SPI data generation process, Integral Consulting Inc. has developed 1) a semiautomated image analysis platform, and 2) a SPI data-specific database architecture that allows both numerical and non-numerical metrics to be incorporated into a standard database structure. An integrated, software-based SPI analysis platform has been developed that imports image files and metadata and provides a graphical user interface. The software automatically stores the data, which can then be reviewed for quality assurance, plotted, statistically analyzed, and mapped or exported to other platforms (e.g., Esri ArcGIS©) for further evaluation. Image processing algorithms have been developed using a combination of open-source and commercially available software packages (e.g., MATLAB® and OpenCV) to automatically quantify key parameters. Novel/Additive Information: SPI technology’s underutilization in the oil and gas industry may be in part due to a lack of standardization in the measurement of basic features in SPI images. A primary objective of this work is to develop a streamlined, standardized, and transparent process for generating and managing SPI data.

02 PETROLEUM↗

Predictive performance of multi-model ensemble forecasts of COVID-19 across European nations

Background: Short-term forecasts of infectious disease burden can contribute to situational awareness and aid capacity planning. Based on best practice in other fields and recent insights in infectious disease epidemiology, one can maximise the predictive performance of such forecasts if multiple models are combined into an ensemble. Here, we report on the performance of ensembles in predicting COVID-19 cases and deaths across Europe between 08 March 2021 and 07 March 2022. Methods: We used open-source tools to develop a public European COVID-19 Forecast Hub. We invited groups globally to contribute weekly forecasts for COVID-19 cases and deaths reported by a standardised source for 32 countries over the next 1–4 weeks. Teams submitted forecasts from March 2021 using standardised quantiles of the predictive distribution. Each week we created an ensemble forecast, where each predictive quantile was calculated as the equally-weighted average (initially the mean and then from 26th July the median) of all individual models’ predictive quantiles. We measured the performance of each model using the relative Weighted Interval Score (WIS), comparing models’ forecast accuracy relative to all other models. We retrospectively explored alternative methods for ensemble forecasts, including weighted averages based on models’ past predictive performance. Results: Over 52 weeks, we collected forecasts from 48 unique models. We evaluated 29 models’ forecast scores in comparison to the ensemble model. We found a weekly ensemble had a consistently strong performance across countries over time. Across all horizons and locations, the ensemble performed better on relative WIS than 83% of participating models’ forecasts of incident cases (with a total N=886 predictions from 23 unique models), and 91% of participating models’ forecasts of deaths (N=763 predictions from 20 models). Across a 1–4 week time horizon, ensemble performance declined with longer forecast periods when forecasting cases, but remained stable over 4 weeks for incident death forecasts. In every forecast across 32 countries, the ensemble outperformed most contributing models when forecasting either cases or deaths, frequently outperforming all of its individual component models. Among several choices of ensemble methods we found that the most influential and best choice was to use a median average of models instead of using the mean, regardless of methods of weighting component forecast models. Conclusions: Our results support the use of combining forecasts from individual models into an ensemble in order to improve predictive performance across epidemiological targets and populations during infectious disease epidemics. Our findings further suggest that median ensemble methods yield better predictive performance more than ones based on means. Our findings also highlight that forecast consumers should place more weight on incident death forecasts than incident case forecasts at forecast horizons greater than 2 weeks. Funding: AA, BH, BL, LWa, MMa, PP, SV funded by National Institutes of Health (NIH) Grant 1R01GM109718, NSF BIG DATA Grant IIS-1633028, NSF Grant No.: OAC-1916805, NSF Expeditions in Computing Grant CCF-1918656, CCF-1917819, NSF RAPID CNS-2028004, NSF RAPID OAC-2027541, US Centers for Disease Control and Prevention 75D30119C05935, a grant from Google, University of Virginia Strategic Investment Fund award number SIF160, Defense Threat Reduction Agency (DTRA) under Contract No. HDTRA1-19-D-0007, and respectively Virginia Dept of Health Grant VDH-21-501-0141, VDH-21-501-0143, VDH-21-501-0147, VDH-21-501-0145, VDH-21-501-0146, VDH-21-501-0142, VDH-21-501-0148. AF, AMa, GL funded by SMIGE - Modelli statistici inferenziali per governare l'epidemia, FISR 2020-Covid-19 I Fase, FISR2020IP-00156, Codice Progetto: PRJ-0695. AM, BK, FD, FR, JK, JN, JZ, KN, MG, MR, MS, RB funded by Ministry of Science and Higher Education of Poland with grant 28/WFSN/2021 to the University of Warsaw. BRe, CPe, JLAz funded by Ministerio de Sanidad/ISCIII. BT, PG funded by PERISCOPE European H2020 project, contract number 101016233. CP, DL, EA, MC, SA funded by European Commission - Directorate-General for Communications Networks, Content and Technology through the contract LC-01485746, and Ministerio de Ciencia, Innovacion y Universidades and FEDER, with the project PGC2018-095456-B-I00. DE., MGu funded by Spanish Ministry of Health / REACT-UE (FEDER). DO, GF, IMi, LC funded by Laboratory Directed Research and Development program of Los Alamos National Laboratory (LANL) under project number 20200700ER. DS, ELR, GG, NGR, NW, YW funded by National Institutes of General Medical Sciences (R35GM119582; the content is solely the responsibility of the authors and does not necessarily represent the official views of NIGMS or the National Institutes of Health). FB, FP funded by InPresa, Lombardy Region, Italy. HG, KS funded by European Centre for Disease Prevention and Control. IV funded by Agencia de Qualitat i Avaluacio Sanitaries de Catalunya (AQuAS) through contract 2021-021OE. JDe, SMo, VP funded by Netzwerk Universitatsmedizin (NUM) project egePan (01KX2021). JPB, SH, TH funded by Federal Ministry of Education and Research (BMBF; grant 05M18SIA). KH, MSc, YKh funded by Project SaxoCOV, funded by the German Free State of Saxony. Presentation of data, model results and simulations also funded by the NFDI4Health Task Force COVID-19 ( https://www.nfdi4health.de/task-force-covid-19-2 ) within the framework of a DFG-project (LO-342/17-1). LP, VE funded by Mathematical and Statistical modelling project (MUNI/A/1615/2020), Online platform for real-time monitoring, analysis and management of epidemic situations (MUNI/11/02202001/2020); VE also supported by RECETOX research infrastructure (Ministry of Education, Youth and Sports of the Czech Republic: LM2018121), the CETOCOEN EXCELLENCE (CZ.02.1.01/0.0/0.0/17-043/0009632), RECETOX RI project (CZ.02.1.01/0.0/0.0/16-013/0001761). NIB funded by Health Protection Research Unit (grant code NIHR200908). SAb, SF funded by Wellcome Trust (210758/Z/18/Z).

60 APPLIED LIFE SCIENCES↗

Laser Safety: A Laser Alignment Practical Training Course

SLAC National Accelerator Laboratory has developed a Laser Alignment Practical Training Course as one of its core laser safety classes. The course is taught to small groups of up to three students and takes 1-3 hours to complete. This practical course is not a substitute for site-specific On-the-Job Training; it does, however, provide a good introduction in core laser safety practices that can be broadly applied. Alignment and diagnostic tasks are performed with low power lasers. Students learn safe alignment and diagnostic techniques and how to avoid common mistakes that might lead to an accident. The class is taught by laser supervisors, enabling them to assess the skill level of new laser personnel and determine the subsequent level of supervision needed. The course has six alignment tasks. For each task, discussion points are given for the instructor to review with the students. The optics setup includes different wavelength lasers, a beam expander, mirrors, irises, a periscope, a beam-splitting polarizer and a diffraction grating. Diagnostic tools include viewing cards, an IR viewer and a ccd camera. Laser eyewear is available to block some laser wavelengths in the setup.

43 PARTICLE ACCELERATORS↗