Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

The Wendelstein 7-X phase contrast imaging diagnostic

We report a phase contrast imaging (PCI) diagnostic has been developed for the Wendelstein 7-X (W7-X) stellarator. The PCI diagnostic provides a line-integrated measurement of turbulent electron density fluctuations, which is essential for understanding high performance scenarios that can lead to improved confinement at fusion-relevant temperatures and densities. The PCI system is also sensitive to coherent fluctuations, which arise from Alfvén eigenmodes or other MHD activity. This paper provides an overview of the hardware and the optical system and presents an example PCI measurement from the W7-X OP1.2b experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of Data Acquisition Algorithms on X-ray Phase Contrast Imaging Computed Tomography

X-ray phase contrast imaging (XPCI) is a non-destructive evaluation technique that enables high-contrast detection of low-attenuation materials that are largely transparent in traditional radiography. Extending a grating based Talbot-Lau XPCI system to three- dimensional imaging with computed tomography (CT) imposes two motion requirements: the analyzer grating must translate transverse to the optical axis to capture image sets for XPCI reconstruction, and the sample must rotate to capture angular data for CT reconstruction. The acquisition algorithm choice determines the order of movement and positioning of the two stages. The choice of image acquisition algorithm for XPCI CT is instrumental to collecting high fidelity data for reconstruction. We investigate how data acquisition influences XPCI CT by comparing two simple data acquisition algorithms and determine that capturing a full phase-stepping image set for a CT projection before rotating the sample results in higher quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of heterodyne detection of radio frequency waves using phase contrast imaging

An upgrade to the DIII–D phase contrast imaging (PCI) diagnostic for detection of radio frequency waves has been implemented using low-noise optical heterodyning. Electro-optical modulation allows detection of waves with frequencies up to 500 MHz with wide flexibility restricted only by the driver electronics, with continuous adjustability up to 100 MHz and fixed frequency drivers needed for higher frequencies. The PCI diagnostic images the line-integrated plasma density fluctuations and provides absolutely calibrated measurements with good wavenumber resolution.

Rost, J. C. [Massachusetts Institute of Technology↗

High-speed phase contrast imaging of spray breakup of jet fuels under combusting conditions

X-ray phase contrast imaging is conducted at 90,517 Hz on a fuel spray to characterize the breakup of the bulk fuel into ligaments and individual droplets in a single-sector, swirl-stabilized combustor under reacting conditions. Phase contrast imaging is used to qualitatively assess spray breakup for two fuels: Jet-A, which represents a normal viscosity fuel, and a blend of JP-5 (64%) and farnesane (36% by volume), which represents a high-viscosity fuel, at three fuel-flow rates and two air inlet temperatures. Time-series images of the fuels show that atomization occurs much more rapidly at higher fuel pressure with thinner ligaments being rapidly shredded. The high-viscosity fuel is qualitatively observed to have markedly longer, thicker ligaments and larger droplet diameters after the primary breakup than the normal viscosity fuel. Using an image processing and droplet quantification strategy, the mean droplet velocity magnitudes were found to decrease with decreasing fuel pressure and fuel-flow rate. The increase in preheat temperature from 323 to 370 K results in an increase in the mean droplet velocity magnitude and a decrease in numerical average and Sauter mean diameter, indicating improved atomization. The high-viscosity fuel was found to have larger average droplet diameters at each condition than the normal viscosity fuel. The increased preheat is found to enhance the combustion efficiency, which is hypothesized to couple with the improved atomization due to the higher combustion temperatures. This indicates the importance of examining spray atomization and breakup under realistic combusting conditions for relevant fuels as the heat release directly couples with the atomization process.

42 ENGINEERING↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Localized phase contrast imaging at the Wendelstein 7-X stellarator

In its basic form, phase contrast imaging (PCI) provides line-integrated measurements of electron density fluctuations in plasmas. As turbulent fluctuations in magnetically confined plasmas have wave vectors almost perpendicular to the background magnetic field, the signals scattered by fluctuations from different parts of the PCI line-of-sight (LoS) are spatially separated in focal planes of the plasma. This allows localized PCI measurements by placing a mask in such a plane, to only permit signals from specific parts of the LoS to reach the PCI detectors. The present paper describes modeling and design of localization masks for the PCI system at the Wendelstein 7-X (W7-X) stellarator as well as the first results obtained using the masks in the recent long-pulse W7-X experimental campaign. During this project, we have extended the theory describing the mask response within the Fraunhofer diffraction model. As a novel development, we show from first principles that the mask response is determined by the fraction of power of the scattered beam spots that passes the mask. These insights have been used to select the W7-X mask design, consisting of a circular cutout, allowing the unscattered beam spot to pass the mask, with wedges covering a fixed angular range outside the central cutout. In the recent W7-X experimental campaign, the masks have verified the location of the main turbulence features observed by the PCI system and provided new information about the location of short-wavelength magnetohydrodynamic modes.

Physics↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Real-time damage characterization for GFRCs using high-speed synchrotron X-ray phase contrast imaging

Here, we report the application of high-speed synchrotron X-ray phase contrast imaging (PCI) in real-time damage characterization for glass fiber reinforced composites (GFRCs) subjected to dynamic loading. Dynamic single-edge notched bending (DSENB) experiments on pre-notched S-2 GFRCs were performed on a modified Kolsky compression bar. During loading, the synchrotron X-ray beam penetrated through the composite specimen from the side to detect damage evolution inside the material. Entire dynamic events were recorded by a high-speed camera as image sequences.0° and 90° unidirectional and cross-ply composites were investigated. An optical imaging technique was also employed to capture similar dynamic events in comparison with the radiographic imaging. It is demonstrated that high-speed X-ray PCI had sufficient phase contrast to characterize a crack initiation at a 20-μm spatial resolution within 920 ns and track the crack geometry during propagation, thereby providing reliable data to quantify the dynamic damage resistance of GFRCs. Furthermore, being capable of recognizing microscopic damage-related features at a sub-10-μm resolution, high-speed X-ray PCI provided fundamental material failure mechanisms to reveal the essential of macroscale structural failure of composites. It can also track the damage evolution inside and between individual plies of laminated composites. However, current high-speed X-ray PCI technique only supports in-situ observation and the high timing and spatial resolutions are limited within a field of view of ~2.5 mm in square, preventing its application in the three-dimensional and larger-area damage detection for GFRC structures.

42 ENGINEERING↗

Invited article: X-ray phase contrast imaging in inertial confinement fusion and high energy density research

X-ray phase contrast imaging (XPCI) provides enhanced image contrast beyond absorption-based x-ray imaging alone due to refraction and diffraction from gradients in the object material density. It is sensitive to small variations in density, such as internal voids, cracks, grains, defects, and material flow, as well as to stronger density variations such as from a shock wave. Beyond its initial use in biology and materials science, XPCI is now routinely used in inertial confinement fusion (ICF) and high energy density (HED) research, first to characterize ICF capsules and targets, and later applied in dynamic experiments, where coherent x-ray sources, ultrafast x-ray pulses, and high temporal and spatial resolution are required. In this Review article, XPCI image formation theory is presented, its diverse use in ICF and HED research is discussed, the unique requirements for ultrafast XPCI imaging are given, as well as current challenges and issues in its use.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-Ray Phase Contrast Imaging for Dynamic Material Mix Experiments, LAO-003-17, Year 3 of 3

X-ray phase contrast imaging with transmission gratings for density profile measurements has been developed and tested for dynamic experimental applications. Talbot-Lau x-ray deflectometry is a new method of measuring x-ray refraction in addition to attenuation and ultrasmall-angle scattering that has recently been developed for static imaging, primarily for medical and industrial applications. To obtain density profiles from fast-evolving systems, we must use a flash x-ray source with a spot size much larger than the continuous microfocus sources of static imaging systems, and we can obtain only a single exposure. The challenges to measuring electron density profiles of two mixed elements from a single-image, low spatial resolution system are addressed, and initial results from the first dynamic experiments with one such system, conducted on a gas launcher at the end of FY 2018 and beginning of FY 2019, are presented. In FY 2019, we designed and built a new deflectometer designed for detonator experiments to test new techniques to improve the sensitivity and reliability of the diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a synthetic phase contrast imaging diagnostic for turbulence studies at Wendelstein 7-X

Abstract We present a synthetic phase contrast imaging (PCI) diagnostic for studying turbulence at the Wendelstein 7-X (W7-X) stellarator. We first describe the implemented instrument response model, which captures diffraction effects, detector noise, and the long-wavelength cutoff due to the phase plate of the PCI system. To verify the instrument response model, we show that it is capable of reproducing the PCI signal generated by the sound wave speaker used for calibration at W7-X. Next, we discuss the calculation of synthetic PCI signals based on the global, nonlinear gyrokinetic codes GENE-3D and EUTERPE, including results from some of the first stellarator simulations of this type with kinetic electrons (KEs) in GENE-3D. While the simulations used in this work lack a neoclassical radial electric field, which is crucial for reproducing experimental PCI signals, they do indicate that the dominant rotation direction and velocities of the turbulent fluctuations can be inferred from the wave number-frequency spectra of the PCI signals, as expected. The synthetic PCI wave number spectra are further shown to be similar to those of the line-integrated fluctuating electron density, with distinct differences between adiabatic and KE simulations, explainable by previously published turbulence models. For example, the wave number spectra of all adiabatic electron simulations analyzed here follow a power law with an exponent close to −5 for sufficiently large wave numbers. This indicates that universal features of electron density turbulence at W7-X may be studied using the PCI system.

EUTERPE↗

A combined Phase Contrast Imaging and heterodyne interferometer for multiscale fluctuation measurements in tokamak plasmas

An upgrade to the Phase Contrast Imaging (PCI) diagnostic on the DIII-D tokamak has successfully combined PCI with density interferometry to provide electron density fluctuation measurements across an unprecedented range in wavenumber. The combined diagnostic uses a single laser and a single beam path through the tokamak, minimizing machine resources in anticipation of future reactor-scale devices where port access will be at a premium. The PCI multichannel detector provides low-noise, wavenumber-resolved detection of moderate-wavenumber turbulence, while the interferometer channel is sensitive to long-wavelength turbulence, including the peak of ion-scale turbulence and MHD. The overlap in wavenumber range between the two schemes allows for an in situ absolute calibration of the PCI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗

Measurement of helicon waves with phase contrast imaging on DIII-D – A theoretical feasibility study

A DIII-D high-beta H-mode discharge, with I p = 850 kA, B t = 2.1 T n e = 4 10 19 m –3 , has been designed to validate full wave modeling of helicon waves by optimizing the expected response of the Phase Contrast Imaging diagnostic. Helicon waves have been predicted to have high current drive efficiency off-axis without facing the accessibility issues of lower-hybrid waves. To test these predictions experimentally, DIII-D has recently commissioned a high-power helicon antenna. To confidently predict the behavior of helicon waves in future devices, measurements of their fundamental properties and validation against models will be essential. Phase contrast imaging (PCI) is an absolutely calibrated internal reference interferometer able to measure density fluctuations with radial wavenumbers k R between 1.5 cm –1 and 20 cm –1 . For helicon waves 2 cm –1 < k R < 10 cm –1 is expected, allowing PCI to measure their envelope and wavenumber spectrum. This makes PCI a powerful tool for the validation of state-of-the-art models, like the AORSA full wave code. AORSA is used to compute the density perturbations measured by the PCI with 2D calculations corresponding to 11 different toroidal mode numbers combined to resolve the trajectory of the helicon wave in 3D. This is necessary because the waves travel 120 degrees toroidally from the antenna to the PCI. Here, a cold plasma finite element model (CPFEM) [4] is used to predict propagation through the scrape-off layer. The result of the CPFEM model is connected to AORSA by creating an artificial Gaussian antenna on the last closed flux surface. PCI shows best results for waves with small vertical wavenumbers k z . Modeling the helicon waves for several past DIII-D experiments shows that k z is minimized if the intersection of the helicon and the PCI laser beams occurs in the midplane. For such an optimized scenario the predicted signal level is two orders of magnitude larger than the background density fluctuations arising from broadband turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Melting temperature of bismuth to 55 GPa using synchrotron X-ray phase contrast imaging

The melting temperature of elemental bismuth under high pressure has been measured to 55 GPa using synchrotron X-ray phase-contrast imaging in the laser-heated diamond anvil cell. Imaging of solid-liquid interface formation, combined with radiometric temperature and X-ray diffraction measurements, reveals a pronounced reduction in melting boundary slope in Bi-V with pressure. The unusually steep initial slope is attributed to low configurational entropy of melting, arising from structural ordering and coordination matching in the cool liquid, while slope reduction is driven by entropy increase correlated with significant liquid structure changes with rising pressure and temperature. Finally, the data rule out kinetic effects on melting in shock compression experiments and demonstrate the need for improved theoretical phase diagrams.

Materials science↗