Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Phase-Measuring System

System developed and used at Langley Research Center measures phase between two signals of same frequency or between two signals, one of which is harmonic multiple of other. Simple and inexpensive device combines digital and analog components to give accurate phase measurements. One signal at frequency f fed to pulse shaper, produces negative pulse at time t4. Pulse applied to control input of sample-and-hold module 1. Second signal, at frequency nf, fed to zero-crossover amplifier, producing square wave at time t. Signal drives first one-shot producing narrow negative pulse at t1. Signal then drives second one-shot producing narrow positive pulse at time t2. This pulse used to turn on solid-state switch and reset integrator circuit to zero.

Davis, W. T.↗

Collimated phase measuring deflectometry

Phase measuring deflectometry has been applied for free-form specular surface metrology, but its measured slope results are sensitive to the depth of sample positioning, which is also called the height-slope ambiguity. The objective of this work is to tackle this height-slope ambiguity problem. The main idea is to introduce collimated camera rays using a telecentric imaging lens and collimated structured-light illumination with a Fourier lens. This setup makes the fringe phases become only sensitive to the surface slopes and insensitive to the depth of the sample positioning. In this way, the slope calculation is theoretically independent of the sample depth. We call this new deflectometry technique Collimated Phase Measuring Deflectometry (CPMD). With our developed CPMD experimental setup, the measurement is insensitive to the depth of sample positioning, e.g., the measured height dispersion is less than 30 nm RMS within a 10 mm depth range when measuring a 50-mm-diameter spherical mirror with a 200 mm radius of curvature. In conclusion, the merits and limitations of the proposed CPMD technique are discussed, revealing its prospects in practical metrology applications and potential future investigations.

36 MATERIALS SCIENCE↗

Temporal averaging of phase measurements in the presence of spurious phase drift - Application to phase-stepped real-time holographic interferometry

A technique that compensates for low spatial frequency spurious phase changes during an interference experiment is developed; it permits temporal averaging of multiple-phase measurements, made before and after object displacement. The method is tested with phase-stepped real-time holographic interferometry applied to cantilever bending of a piezoelectric bimorph ceramic. Results indicate that temporal averaging of the corrected data significantly reduces the white noise in a phase measurement without incurring systematic errors or sacrificing spatial resolution. White noise is reduced from 3 deg to less than 1 deg using these methods.

Ovryn, B.↗

Calibrated VLF phase measurements: Simultaneous remote and local measurements of 10.2kHz carrier phase using cesium standards

An investigation of spatial irregularity of VLF phase due to nearby objects and terrain is discussed. It is shown that the phase is regular to the microsecond accuracy of the instrumentation, and that a grounded steel tower in close proximity to a whip antenna will not affect the phase measurement. However, antennas coupling to trees may cause an anomalous phase shift.

Swanson, E. R.↗

Precise T and F intercomparison via VLF phase measurements

Continuous phase recording of the 16kHz transmission from GBR (UK) are being made and published midday phase data of GBR are received regularly from laboratories in the US, FGR, and UK. The local time scale (UTC, India), at the National Physical Laboratory in New Delhi, and those at the foreign laboratories are intercompared using the VLF phase data. A major factor which limits the accuracy of long term comparison is the seasonal variation in the VLF over delay over long paths. By taking into account the seasonal delay variations in a semiempirical way, the accuracy of time and frequency comparisons can be improved. Over a one year period, accuracy of a few parts in 10 to the 14th power in frequency and 1 to 2 micron sec in time were obtained. The relative frequency offset difference between UTC, (India) and UTC (PTB, Germany) of (7.0 + or - 0.1) x 10 to the -13 power agrees well with that obtained in a satellite experiment.

Gupta, A. S.↗

Improving Phase Measurement Procedures for Pump-Probe Experiments

Pump-probe experiments use a visible laser to excite an atom or molecule, while an X-ray pulse measures its shape. The phases and pulse times of each beam are used to calculate the object's positing at a given time - a moving picture of the chemical reaction. Currently, the fastest X-ray pulses can travel a time-length of five femtoseconds. However, present-day phase measurements can only be done as quickly as 50 femtoseconds. The purpose of this research is to explore ways in which phase-timing measurements can be improved. Three experiments are undergone to find the key factors in phase-timing. Different frequency mixers, the radio frequency (RF) components used for phase measurement, are tested for the highest sensitivity. These same mixers are then tested using two different power splitters for the lowest noise-to-sensitivity ratio. Lastly, the temperature dependency of phase is explored by testing each component at a range of temperatures to see how the phase is affected. This research demonstrated that certain mixers were more sensitive than others; on average, one mixer performed the best with a sensitivity of 0.0230 V/ps. The results also showed that same mixer combined with one splitter gave the best noise-to-sensitivity ratio overall with an average of 6.95E-04 fs/{radical}(Hz). All the components tested exhibited a temperature-dependent phase change (ranging from 1.69 to 81.6 fs/{sup o}C); the same mixer that performed at the highest sensitivity with the least noise had a significantly greater phase change than the other two. In conclusion, the experiments showed that a temperature-controlled environment is most appropriate for phase measurement. They also demonstrated that mixers are not significantly noisy and that certain types of mixers may perform better than others, which could be accounted for in their construction. The results of this research encourage further investigation into the study of different mixers and other RF components used in pump-probe experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LISA phase measurement technique

The LISA mission will form the equivalent of a Michelson interferometric beat signal from the 1064nm laser beams traversing the inter-spacecraft arms. The design gravitational wave sensitivity requires measurement of round trip path differences for each detector to be about 10 pddHz over a frequency range from 10^10-4 to 10^-1 Hz. Thus LISA'S phasemeter must measure the beat signal phase to 10^-5 cycle/square root of Hz at 1mHz. Doppler shifts between spacecraft in their orbits are expected to range from 1 to 15 MHz. Phase measurement using the digital phase-locked loop approach incorporated in a modified TurboRogue GPS receiver has been investigated in this study. It is found that only resolution in the range of 10^-4 to 10^-3 cycle/square root of Hz at 1 mHz is achievable with this hardware. Abrupt fluctuations in the phase measurement at the millicycle level are responsible for the limitation.

phasemeter↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

Canonical phase measurement is pure

We show that the canonical phase measurement is pure in the sense that the corresponding positive operator valued measure (POVM) is extremal in the convex set of all POVMs. This means that the canonical phase measurement cannot be interpreted as a noisy measurement even if it is not a projection valued measure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modal phase measuring deflectometry

Here in this work, a model based method is applied to phase measuring deflectometry, which is named as modal phase measuring deflectometry. The height and slopes of the surface under test are represented by mathematical models and updated by optimizing the model coefficients to minimize the discrepancy between the reprojection in ray tracing and the actual measurement. The pose of the screen relative to the camera is pre-calibrated and further optimized together with the shape coefficients of the surface under test. Simulations and experiments are conducted to demonstrate the feasibility of the proposed approach.

42 ENGINEERING↗

High-Accuracy, High-Dynamic-Range Phase-Measurement System

A digital phase meter has been designed to satisfy stringent requirements for measuring differences between phases of radio-frequency (RF) subcarrier signals modulated onto laser beams involved in the operation of a planned space-borne gravitational-wave-detecting heterodyne laser interferometer. The capabilities of this system could also be used in diverse terrestrial applications that involve measurement of signal phases, including metrology, navigation, and communications.

Shaddock, Daniel↗

Model mismatch analysis and compensation for modal phase measuring deflectometry

The correspondence residuals due to the discrepancy between the reality and the shape model in use are analyzed for the modal phase measuring deflectometry. Slope residuals are calculated from these discrepancies between the modal estimation and practical acquisition. Since the shape mismatch mainly occurs locally, zonal integration methods which are good at dealing with local variations are used to reconstruct the height residual for compensation. Finally, results of both simulation and experiment indicate the proposed height compensation method is effective, which can be used as a post-complement for the modal phase measuring deflectometry.

47 OTHER INSTRUMENTATION↗

Review of phase measuring deflectometry

As a low cost, full-field three-dimensional shape measurement technique with high dynamic range, Phase Measuring Deflectometry (PMD) has been studied and improved to be a simple and effective manner to inspect specular reflecting surfaces. In this review, the fundamental principle and the basic concepts of PMD technique are introduced and followed by a brief overview of its key developments since it was first proposed. In addition, the similarities and differences compared with other related techniques are discussed to highlight the distinguishing features of the PMD technique. In conclusion, we will address the major challenges, the existing solutions and the remaining limitations in this technique to provide some suggestions for potential future investigations.

42 ENGINEERING↗

Linear Modelling from Betatron Phase Measurements at the Fermilab Recycler NOvA ring

Utilizing the measurement of coherent betatron oscillation phase has emerged as fast and precise approach for identifying and rectifying errors in implementing a desired lattice in CESR (Cornell Electron Storage Ring). One key advantage of betatron phase measurement over β measurement is its sensitivity to phase variations between widely separated points. This methodology has been successfully implemented for the Recycler NOvA Ring at Fermilab, with the adoption of TAO (Tool for Accelerator Optics) developed by Cornell University. By employing this technique, a linear model of the Recycler NOvA ring is established, enabling the correction of quadrupole errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time domain phase measuring apparatus

The phase and/or period stability of a device is determined by connecting the device in one orthogonal arm of a phase detector having a mixer. In the other arm is an adjustable, variable phase shift device. The output of the mixer is fed through an active low pass filter to derive a DC voltage indicative of the phase shift. The variable phase device is adjusted so that the DC voltage will nullify the phase shift of the tested device under normal conditions. The DC voltage level is converted into a time interval indicative of the phase change of the tested device by determining when the level equals the amplitude of a low frequency ramp voltage. The interval between adjacent equality points can be measured or the period between a reference point on the ramp voltage and the quality be measured.

Reinhardt, V. S.↗

A cavity radiometer for Earth albedo measurement, phase 1

Radiometric measurements of the directional albedo of the Earth requires a detector with a flat response from 0.2 to 50 microns, a response time of about 2 seconds, a sensitivity of the order of 0.02 mw/sq cm, and a measurement uncertainty of less than 5 percent. Absolute cavity radiometers easily meet the spectral response and accuracy requirements for Earth albedo measurements, but the radiometers available today lack the necessary sensitivity and response time. The specific innovations addressed were the development of a very low thermal mass cavity and printed/deposited thermocouple sensing elements which were incorporated into the radiometer design to produce a sensitive, fast response, absolute radiometer. The cavity is applicable to the measurement of the reflected and radiated fluxes from the Earth surface and lower atmosphere from low Earth orbit satellites. The effort consisted of requirements and thermal analysis; design, construction, and test of prototype elements of the black cavity and sensor elements to show proof-of-concept. The results obtained indicate that a black body cavity sensor that has inherently a flat response from 0.2 to 50 microns can be produced which has a sensitivity of at least 0.02 mw/sq cm per micro volt ouput and with a time constant of less than two seconds. Additional work is required to develop the required thermopile.

Source record↗

Quantum phase measurement and Gauss sum factorization of large integers in a superconducting circuit

We study the implementation of quantum phase measurement in a superconducting circuit, where two Josephson phase qubits are coupled to the photon field inside a resonator. We show that the relative phase of the superposition of two Fock states can be imprinted in one of the qubits. The qubit can thus be used to probe and store the quantum coherence of two distinguishable Fock states of the single-mode photon field inside the resonator. The effects of dissipation of the photon field on the phase detection are investigated. We find that the visibilities can be greatly enhanced if the Kerr nonlinearity is exploited. We also show that the phase measurement method can be used to perform the Gauss sum factorization of numbers ({>=}10{sup 4}) into a product of prime integers, as well as to precisely measure both the resonator's frequency and the nonlinear interaction strength. The largest factorizable number is mainly limited by the coherence time. If the relaxation time of the resonator were to be {approx}0 {mu}s ({approx}1 ms), then the largest factorizable number can be {>=}10{sup 4}N ({>=}10{sup 7}N), where N is the number of photons in the resonator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗