Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Collimated phase measuring deflectometry

Phase measuring deflectometry has been applied for free-form specular surface metrology, but its measured slope results are sensitive to the depth of sample positioning, which is also called the height-slope ambiguity. The objective of this work is to tackle this height-slope ambiguity problem. The main idea is to introduce collimated camera rays using a telecentric imaging lens and collimated structured-light illumination with a Fourier lens. This setup makes the fringe phases become only sensitive to the surface slopes and insensitive to the depth of the sample positioning. In this way, the slope calculation is theoretically independent of the sample depth. We call this new deflectometry technique Collimated Phase Measuring Deflectometry (CPMD). With our developed CPMD experimental setup, the measurement is insensitive to the depth of sample positioning, e.g., the measured height dispersion is less than 30 nm RMS within a 10 mm depth range when measuring a 50-mm-diameter spherical mirror with a 200 mm radius of curvature. In conclusion, the merits and limitations of the proposed CPMD technique are discussed, revealing its prospects in practical metrology applications and potential future investigations.

36 MATERIALS SCIENCE↗

Improving Phase Measurement Procedures for Pump-Probe Experiments

Pump-probe experiments use a visible laser to excite an atom or molecule, while an X-ray pulse measures its shape. The phases and pulse times of each beam are used to calculate the object's positing at a given time - a moving picture of the chemical reaction. Currently, the fastest X-ray pulses can travel a time-length of five femtoseconds. However, present-day phase measurements can only be done as quickly as 50 femtoseconds. The purpose of this research is to explore ways in which phase-timing measurements can be improved. Three experiments are undergone to find the key factors in phase-timing. Different frequency mixers, the radio frequency (RF) components used for phase measurement, are tested for the highest sensitivity. These same mixers are then tested using two different power splitters for the lowest noise-to-sensitivity ratio. Lastly, the temperature dependency of phase is explored by testing each component at a range of temperatures to see how the phase is affected. This research demonstrated that certain mixers were more sensitive than others; on average, one mixer performed the best with a sensitivity of 0.0230 V/ps. The results also showed that same mixer combined with one splitter gave the best noise-to-sensitivity ratio overall with an average of 6.95E-04 fs/{radical}(Hz). All the components tested exhibited a temperature-dependent phase change (ranging from 1.69 to 81.6 fs/{sup o}C); the same mixer that performed at the highest sensitivity with the least noise had a significantly greater phase change than the other two. In conclusion, the experiments showed that a temperature-controlled environment is most appropriate for phase measurement. They also demonstrated that mixers are not significantly noisy and that certain types of mixers may perform better than others, which could be accounted for in their construction. The results of this research encourage further investigation into the study of different mixers and other RF components used in pump-probe experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

Canonical phase measurement is pure

We show that the canonical phase measurement is pure in the sense that the corresponding positive operator valued measure (POVM) is extremal in the convex set of all POVMs. This means that the canonical phase measurement cannot be interpreted as a noisy measurement even if it is not a projection valued measure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modal phase measuring deflectometry

Here in this work, a model based method is applied to phase measuring deflectometry, which is named as modal phase measuring deflectometry. The height and slopes of the surface under test are represented by mathematical models and updated by optimizing the model coefficients to minimize the discrepancy between the reprojection in ray tracing and the actual measurement. The pose of the screen relative to the camera is pre-calibrated and further optimized together with the shape coefficients of the surface under test. Simulations and experiments are conducted to demonstrate the feasibility of the proposed approach.

42 ENGINEERING↗

Model mismatch analysis and compensation for modal phase measuring deflectometry

The correspondence residuals due to the discrepancy between the reality and the shape model in use are analyzed for the modal phase measuring deflectometry. Slope residuals are calculated from these discrepancies between the modal estimation and practical acquisition. Since the shape mismatch mainly occurs locally, zonal integration methods which are good at dealing with local variations are used to reconstruct the height residual for compensation. Finally, results of both simulation and experiment indicate the proposed height compensation method is effective, which can be used as a post-complement for the modal phase measuring deflectometry.

47 OTHER INSTRUMENTATION↗

Review of phase measuring deflectometry

As a low cost, full-field three-dimensional shape measurement technique with high dynamic range, Phase Measuring Deflectometry (PMD) has been studied and improved to be a simple and effective manner to inspect specular reflecting surfaces. In this review, the fundamental principle and the basic concepts of PMD technique are introduced and followed by a brief overview of its key developments since it was first proposed. In addition, the similarities and differences compared with other related techniques are discussed to highlight the distinguishing features of the PMD technique. In conclusion, we will address the major challenges, the existing solutions and the remaining limitations in this technique to provide some suggestions for potential future investigations.

42 ENGINEERING↗

Linear Modelling from Betatron Phase Measurements at the Fermilab Recycler NOvA ring

Utilizing the measurement of coherent betatron oscillation phase has emerged as fast and precise approach for identifying and rectifying errors in implementing a desired lattice in CESR (Cornell Electron Storage Ring). One key advantage of betatron phase measurement over β measurement is its sensitivity to phase variations between widely separated points. This methodology has been successfully implemented for the Recycler NOvA Ring at Fermilab, with the adoption of TAO (Tool for Accelerator Optics) developed by Cornell University. By employing this technique, a linear model of the Recycler NOvA ring is established, enabling the correction of quadrupole errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum phase measurement and Gauss sum factorization of large integers in a superconducting circuit

We study the implementation of quantum phase measurement in a superconducting circuit, where two Josephson phase qubits are coupled to the photon field inside a resonator. We show that the relative phase of the superposition of two Fock states can be imprinted in one of the qubits. The qubit can thus be used to probe and store the quantum coherence of two distinguishable Fock states of the single-mode photon field inside the resonator. The effects of dissipation of the photon field on the phase detection are investigated. We find that the visibilities can be greatly enhanced if the Kerr nonlinearity is exploited. We also show that the phase measurement method can be used to perform the Gauss sum factorization of numbers ({>=}10{sup 4}) into a product of prime integers, as well as to precisely measure both the resonator's frequency and the nonlinear interaction strength. The largest factorizable number is mainly limited by the coherence time. If the relaxation time of the resonator were to be {approx}0 {mu}s ({approx}1 ms), then the largest factorizable number can be {>=}10{sup 4}N ({>=}10{sup 7}N), where N is the number of photons in the resonator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collimated phase measuring deflectometry II: Re-design of the optical layout for high-curvature surfaces

Collimated phase measuring deflectometry (CPMD) is an optical metrology technique developed to improve upon traditional phase measuring deflectometry (PMD). CPMD utilizes telecentric imaging and collimated structured light illumination to eliminate the height-slope ambiguity present in traditional PMD measurements. After the publication of the first CPMD paper, efforts began to optimize the optical layout of the CPMD system. The first proposed change, and the one detailed in this work, was to move the Fourier transform (FT) lens closer to the surface under test (SUT). Moving the FT lens closer to the SUT meant that for a given FT lens diameter, a larger range of surface slopes on the SUT could be measured. This change to the optical layout was not trivial and introduced at least two concerns that had to be addressed: telecentricity in the imaging path and possible ghost reflections from the re-located FT lens. Here, in this work, we examine how these concerns were addressed and present results showing that the revised optical layout is capable of measurement results at least as good as the original CPMD optical layout. We also demonstrate the increased slope measuring range of the revised optical layout.

47 OTHER INSTRUMENTATION↗

Design of geometric phase measurement in EAST Tokamak

The optimum scheme for geometric phase measurement in EAST Tokamak is proposed in this paper. The theoretical values of geometric phase for the probe beams of EAST Polarimeter-Interferometer (POINT) system are calculated by path integration in parameter space. Meanwhile, the influences of some controllable parameters on geometric phase are evaluated. The feasibility and challenge of distinguishing geometric effect in the POINT signal are also assessed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Six-photon de Broglie wavelength and phase-measurement sensitivity improving upon the standard quantum limit

Using only linear optics and projection measurement, we propose a simple multiphoton interference scheme for the demonstration of six-photon de Broglie wavelength, which leads to a cos6{phi} dependence on the single-photon phase {phi}. Although the scheme does not reach the Heisenberg limit in sensitivity for phase measurement, it improves upon the standard quantum limit with super-resolved sensitivity in phase measurement. We discuss possible experimental implementation with three pairs of photons from parametric down-conversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Formation of x-ray vortex dipoles using a single diffraction pattern and direct phase measurement using interferometry

We have devised a method for generating x-ray vortices by using a diffraction pattern from a simple aperture with illumination wave fronts with spherical curvatures. The interferometry visualized the x-ray vortex dipoles by the direct phase measurement. Our interference technique enabled us to sensitively detect and quantitatively measure various phase dislocations on the x-ray wave fronts, providing useful methodologies for beam diagnostics and materials science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase measurement in temporal speckle pattern interferometry signals presenting low-modulated regions by means of the bidimensional empirical mode decomposition

We propose a phase measurement technique to retrieve optical phase distributions coded in noisy temporal speckle pattern interferometry signals presenting regions of adjacent low-modulated pixels, which is based on the bidimensional empirical mode decomposition and the Hilbert transform. It is shown that this approach can effectively remove noise and minimize the influence of large sets of adjacent nonmodulated pixels located in the time series of speckle interferograms. The performance of the phase retrieval approach is analyzed using computer-simulated speckle interferograms modulated with a temporal carrier. The results are also compared with those given by a technique based on the one-dimensional empirical mode decomposition. The advantages and limitations of the proposed approach are finally discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High resolution kilometric range optical telemetry in air by radio frequency phase measurement

We have developed an optical Absolute Distance Meter (ADM) based on the measurement of the phase accumulated by a Radio Frequency wave during its propagation in the air by a laser beam. In this article, the ADM principle will be described and the main results will be presented. In particular, we will emphasize how the choice of an appropriate photodetector can significantly improve the telemeter performances by minimizing the amplitude to phase conversion. Our prototype, tested in the field, has proven its efficiency with a resolution better than 15 μm for a measurement time of 10 ms and distances up to 1.2 km.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrons measure phase behavior in pores at Angstrom size

Researchers have measured the phase behavior of green house gases in pores at the Angstrom-level, using small angle neutron scattering (SANS) at the Oak Ridge National Laboratory's High Flux Isotope Reactor. Yuri Melnichenko, an instrument scientist on the General Purpose Small Angle Neutron Scattering (GP SANS) Diffractometer at ORNL's High Flux Isotope Reactor, his postdoctoral associate Lilin He and collaborators Nidia Gallego and Cristian Contescu from the Material Sciences Division (ORNL) were engaged in the work. They were studying nanoporous carbons to assess their attractiveness as storage media for hydrogen, with a view to potential use for on-board hydrogen storage for transportation applications. Nanoporous carbons can also serve as electrode material for supercapacitors and batteries. The researchers successfully determined that the most efficiently condensing pore size in a carbon nanoporous material for hydrogen storage is less than one nanometer. In a paper recently published by the Journal of the American Chemical Society, the collaborators used small angle neutron scattering to study how hydrogen condenses in small pores at ambient temperature. They discovered that the surface-molecule interactions create internal pressures in pores that may exceed the external gas pressure by a factor of up to 50. 'This is an exciting result,' Melnichenko said, 'as you achieve extreme densification in pores 'for free', i.e. without spending any energy. These results can be used to guide the development of new carbon adsorbents tailored to maximize hydrogen storage capacities.' Another important factor that defines the adsorption capacity of sub-nanometer pores is their shape. In order to get accurate structural information and maximize sorption capacity, it is important that pores are small and of approximately uniform size. In collaboration with Drexel University's Yury Gogotsi who supplied the samples, Melnichenko and his collaborators used the GP SANS instrument to study how the size and shape of pores in sub-nanometer porous carbons varies, depending on the manufacturing conditions. While small angle X-ray scattering (SAXS) can do the job too, Melnichenko says, the SANS method broke new ground in analyzing the shape and behavior of pores at subnanometer size, when subjected to varying synthesis temperature. 'We found that these very small pores are in fact spherical, and that when we change the synthesis conditions, they become elongated, even 'slit-like', and all of this on a subnanometer scale,' Melnichenko said.

08 HYDROGEN↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗