Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photon correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Enhanced resolution particle size distributions by multiple angle photon correlation spectroscopy

Photon correlation spectroscopy (PCS) has become a method of choice for measuring submicrometer particles. It is capable of rapid, accurate measurements of mean particle size. Since the measurements are nonperturbing, it is ideal for monitoring systems undergoing dynamic changes. Despite its widespread acceptance, the information content of PCS measurements for particle size distributions is low and provides limited resolution. A method is presented whereby PCS measurements made at several scattering angles plus the angular distribution of light scattered from the particles are combined in a single simultaneous analysis to effect an enhanced resolution particle size distribution. The efficacy of the method is assessed by recovering size distributions from computer simulated data and by comparisons of conventional PCS measurements of polystyrene spheres with those made by the new method.

Bott, Steven E.↗

2004 Photon Correlation and Scattering Conference

The Photon Correlation and Scattering (PCS) meeting welcomes all who are interested in the art and science of photon correlation and its application to optical scattering. The meeting is intended to enhance interactions between theory, applications, instrument design, and participants.

Meyer, William↗

Using Correlated Photons to Suppress Background Noise

A proposed method of suppressing the effect of background noise in an optical communication system would exploit the transmission and reception of correlated photons at the receiver. The method would not afford any advantage in a system in which performance is limited by shot noise. However, if the performance of the system is limited by background noise (e.g., sunlight in the case of a free-space optical communication system or incoherently scattered in-band photons in the case of a fiber-optic communication system), then the proposed method could offer an advantage: the proposed method would make it possible to achieve a signal-to-noise ratio (S/N) significantly greater than that of an otherwise equivalent background- noise-limited optical communication system based on the classical transmission and reception of uncorrelated photons. The figure schematically depicts a classical optical-communication system and a system according to the proposed method. In the classical system, a modulated laser beam is transmitted along an optical path to a receiver, the optics of which include a narrow-band-pass filter that suppresses some of the background noise. A photodetector in the receiver detects the laser-beam and background photons, most or all of which are uncorrelated. In the proposed system, correlated photons would be generated at the transmitter by making a modulated laser beam pass through a nonlinear parametric down-conversion crystal. The sum of frequencies of the correlated photons in each pair would equal the frequency of the incident photon from which they were generated. As in the classical system, the correlated photons would travel along an optical path to a receiver, where they would be band-pass filtered and detected. Unlike in the classical system, the photodetector in the receiver in this system would be one that intrinsically favors the detection of pairs of correlated photons over the detection of uncorrelated photons. Even though there would be no way of knowing the precise location and time of creation of a given pair of correlated signal photons in the nonlinear down-conversion crystal, the fact that the photons are necessarily created at the same time and place makes it possible to utilize conventional geometrical imaging optics to reunite the photons in coincidence in the receiving photodetector. Because most or all of the signal photons would be correlated while most or all of the noise photons would be uncorrelated, the S/N would be correspondingly enhanced in the photodetector output. An additional advantage to be gained by use of a correlated-photon detector is that it could be capable of recovering the signal even in the presence of background light so bright that a classical uncorrelated-photon detector would be saturated. A blocked-impurity-band (BIB) photodetector that preferentially detects pairs of correlated photons over uncorrelated ones and that operates at a quantum efficiency of 88 percent is commercially available. This detector must be cooled to the temperature of liquid helium to obtain the desired low-noise performance. It is planned to use this detector in a proof-of-principle demonstration. In addition, it may be possible to develop GaN-based photodetectors that could offer the desired low-noise performance at room temperature.

Jackson, Deborah↗

Statistical fitting accuracy in photon correlation spectroscopy

Continuing our experimental investigation of the fitting accuracy associated with photon correlation spectroscopy, we collect 150 correlograms of light scattered at 90 deg from a thermostated sample of 91-nm-diameter, polystyrene latex spheres in water. The correlograms are taken with two correlators: one with linearly spaced channels and one with geometrically spaced channels. Decay rates are extracted from the single-exponential correlograms with both nonlinear least-squares fits and second-order cumulant fits. We make several statistical comparisons between the two fitting techniques and verify an earlier result that there is no sample-time dependence in the decay rate errors. We find, however, that the two fitting techniques give decay rates that differ by 1 percent.

Shaumeyer, J. N.↗

Study of photon correlation techniques for processing of laser velocimeter signals

The objective was to provide the theory and a system design for a new type of photon counting processor for low level dual scatter laser velocimeter (LV) signals which would be capable of both the first order measurements of mean flow and turbulence intensity and also the second order time statistics: cross correlation auto correlation, and related spectra. A general Poisson process model for low level LV signals and noise which is valid from the photon-resolved regime all the way to the limiting case of nonstationary Gaussian noise was used. Computer simulation algorithms and higher order statistical moment analysis of Poisson processes were derived and applied to the analysis of photon correlation techniques. A system design using a unique dual correlate and subtract frequency discriminator technique is postulated and analyzed. Expectation analysis indicates that the objective measurements are feasible.

Mayo, W. T., Jr.↗

Feasibility study of transit photon correlation anemometer for Ames Research Center unitary wind tunnel plan

A laser transit anemometer measured a two-dimensional vector velocity, using the transit time of scattering particles between two focused and parallel laser beams. The objectives were: (1) the determination of the concentration levels and light scattering efficiencies of naturally occurring, submicron particles in the NASA/Ames unitary wind tunnel and (2) the evaluation based on these measured data of a laser transit anemometer with digital correlation processing for nonintrusive velocity measurement in this facility. The evaluation criteria were the speeds at which point velocity measurements could be realized with this technique (as determined from computer simulations) for given accuracy requirements.

Mayo, W. T., Jr.↗

Limitation on two-photon temporal correlation

We show theoretically that two-photon correlation time for a biphoton, a pair of entangled photons generated in the process of parametric down conversion, is limited by the inverse frequency width of the single-photon spectrum, which is limited by the dispersion of the nonlinear material used for the pair generation. The dispersion is determined by the transparency window of the material, which provides the ultimate limitation for the twophoton correlation time. We discuss several experimental approaches enabling realization of such a limiting case.

Maleki, Lute↗

Miniature instrumentation for laser light scattering experiments

Traditional optical systems for photon correlation spectroscopy and laser anemometry have relied upon physically large and fairly expensive lasers, bulk-optics such as lenses of a few inches diameter, large mechanical mounts and carefully selected, fragile and bulky photon counting photomultiplier detectors. In some cases, experimental fluid dynamics at a desired position in a flow, perhaps deep inside complex machinery, is physically impossible or very difficult. Similar problems exist with photon correlation spectroscopy, e.g., remote and heterodyne experiments. Various optical and electro optical components were investigated and characterized with the aim of replacing existing photon correlation laser spectroscopy and anemometry techniques in miniaturized form, and with significant cost reduction. Very recently, a range of miniature, modular light scattering systems were constructed from little solid state optical and electro optical components, and experimentally verified measurement performance comparable to standard lab photon correlation spectroscopy and laser anemometry equipment.

Brown, Robert G. W.↗

Two-Photon Fluorescence Correlation Spectroscopy

We will describe a two-photon microscope currently under development at the NASA Glenn Research Center. It is composed of a Coherent Mira 900 tunable, pulsed Titanium:Sapphire laser system, an Olympus Fluoview 300 confocal scanning head, and a Leica DM IRE inverted microscope. It will be used in conjunction with a technique known as fluorescence correlation spectroscopy (FCS) to study intracellular protein dynamics. We will briefly explain the advantages of the two-photon system over a conventional confocal microscope, and provide some preliminary experimental results.

Zimmerli, Gregory A.↗

Study of Einstein-Podolsky-Rosen state for space-time variables in a two photon interference experiment

A pair of correlated photons generated from parametric down conversion was sent to two independent Michelson interferometers. Second order interference was studied by means of a coincidence measurement between the outputs of two interferometers. The reported experiment and analysis studied this second order interference phenomena from the point of view of Einstein-Podolsky-Rosen paradox. The experiment was done in two steps. The first step of the experiment used 50 psec and 3 nsec coincidence time windows simultaneously. The 50 psec window was able to distinguish a 1.5 cm optical path difference in the interferometers. The interference visibility was measured to be 38 percent and 21 percent for the 50 psec time window and 22 percent and 7 percent for the 3 nsec time window, when the optical path difference of the interferometers were 2 cm and 4 cm, respectively. By comparing the visibilities between these two windows, the experiment showed the non-classical effect which resulted from an E.P.R. state. The second step of the experiment used a 20 psec coincidence time window, which was able to distinguish a 6 mm optical path difference in the interferometers. The interference visibilities were measured to be 59 percent for an optical path difference of 7 mm. This is the first observation of visibility greater than 50 percent for a two interferometer E.P.R. experiment which demonstrates nonclassical correlation of space-time variables.

Shih, Y. H.↗

Photon counting processor for laser velocimetry

In some of the more difficult applications of laser Doppler velocimetry such as in combustion research, transonic flow, transverse wind, and others, the optical signals are too small for classical detection methods. This paper summarizes the theory, experimental prototype hardware, and test results for a new type of high-speed photon-correlation signal processor which is being developed for weak laser velocimeter signals and other photon-resolved signals. The new system may also be considered to be a statistical digital frequency discriminator. It uses full multiplication with 10-nsec delay time and has the potential for extension to the measurement of the velocity correlations and spectra.

Mayo, W. T., Jr.↗

Nonlocal effects on the polarization state of a photon, induced by distant absorbers

A variant of a Franson's two-photon correlation experiment is discussed, in which the linear polarization state of one of the photons depends on the path followed in the interferometer. It is shown that although the path difference is greater than the coherence length, the photon can be found in a polarization state represented by the superposition of the polarization states associated to the paths when there is coincident detection. Since the photons, produced via parametric down-conversion, are fairly well localized in space and time, the situation in which one of the photons is detected before the other can reach the interferometer raises an intriguing point: it seems that in some cases the second photon would have to be described by two wave packets simultaneously. Unlike previous experiments, in which nonlocal effects were induced by means of polarizers of phase shifters, in the proposed experiment nonlocal effects can be induced by means of variable absorbers.

Ryff, Luis Carlos B.↗

Light scattering and dynamics of interacting Brownian particles

The relative motions of interacting Brownian particles in liquids may be described as radial diffusion in an effective potential of the mean force. By using a harmonic approximation for the effective potential, the intermediate scattering function may also be evaluated. For polystyrene spheres of 250 A mean radius in aqueous environment at 0.00125 g/cu cm concentration, the results for the calculated mean square displacement are in qualitative agreement with experimental data from photon correlation spectroscopy. Because of the interactions, the functions deviate considerably from the exponential forms for the free particles.

Tsang, T.↗