Search NASASearch

SEARCH · Search NASA

Results for “Photon pairs & parametric down-conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

A periodically poled MgO doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532 nm photons into time-energy entangled pairs of 800 and 1600 nm photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers also known as a Franson interferometer after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes due to interference between the photon probability amplitudes are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs.

time-energy entanglement

Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

A periodically poled MgO - doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532-nanometer photons into time-energy entangled pairs of 800- and 1600-nanometer photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers - also known as a Franson interferometer - after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes - due to interference between the photon probability amplitudes - are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs.

Time-Energy Entanglement

Analysis of Quantum Information Test-Bed by Parametric Down-Converted Photons Interference Measurement

Quantum optical experiments require all the components involved to be extremely stable relative to each other. The stability can be "measured" by using an interferometric experiment. A pair of coherent photons produced by parametric down-conversion could be chosen to be orthogonally polarized initially. By rotating the polarization of one of the wave packets, they can be recombined at a beam splitter such that interference will occur. Theoretically, the interference will create four terms in the wave function. Two terms with both photons going to the same detector, and two terms will have the photons each going to different detectors. However, the latter will cancel each other out, thus no photons will arrive at the two detectors simultaneously under ideal conditions. The stability Of the test-bed can then be inferred by the dependence of coincidence count on the rotation angle.

To, Wing H.

Using Correlated Photons to Suppress Background Noise

A proposed method of suppressing the effect of background noise in an optical communication system would exploit the transmission and reception of correlated photons at the receiver. The method would not afford any advantage in a system in which performance is limited by shot noise. However, if the performance of the system is limited by background noise (e.g., sunlight in the case of a free-space optical communication system or incoherently scattered in-band photons in the case of a fiber-optic communication system), then the proposed method could offer an advantage: the proposed method would make it possible to achieve a signal-to-noise ratio (S/N) significantly greater than that of an otherwise equivalent background- noise-limited optical communication system based on the classical transmission and reception of uncorrelated photons. The figure schematically depicts a classical optical-communication system and a system according to the proposed method. In the classical system, a modulated laser beam is transmitted along an optical path to a receiver, the optics of which include a narrow-band-pass filter that suppresses some of the background noise. A photodetector in the receiver detects the laser-beam and background photons, most or all of which are uncorrelated. In the proposed system, correlated photons would be generated at the transmitter by making a modulated laser beam pass through a nonlinear parametric down-conversion crystal. The sum of frequencies of the correlated photons in each pair would equal the frequency of the incident photon from which they were generated. As in the classical system, the correlated photons would travel along an optical path to a receiver, where they would be band-pass filtered and detected. Unlike in the classical system, the photodetector in the receiver in this system would be one that intrinsically favors the detection of pairs of correlated photons over the detection of uncorrelated photons. Even though there would be no way of knowing the precise location and time of creation of a given pair of correlated signal photons in the nonlinear down-conversion crystal, the fact that the photons are necessarily created at the same time and place makes it possible to utilize conventional geometrical imaging optics to reunite the photons in coincidence in the receiving photodetector. Because most or all of the signal photons would be correlated while most or all of the noise photons would be uncorrelated, the S/N would be correspondingly enhanced in the photodetector output. An additional advantage to be gained by use of a correlated-photon detector is that it could be capable of recovering the signal even in the presence of background light so bright that a classical uncorrelated-photon detector would be saturated. A blocked-impurity-band (BIB) photodetector that preferentially detects pairs of correlated photons over uncorrelated ones and that operates at a quantum efficiency of 88 percent is commercially available. This detector must be cooled to the temperature of liquid helium to obtain the desired low-noise performance. It is planned to use this detector in a proof-of-principle demonstration. In addition, it may be possible to develop GaN-based photodetectors that could offer the desired low-noise performance at room temperature.

Jackson, Deborah

The energy-time uncertainty principle and the EPR paradox: Experiments involving correlated two-photon emission in parametric down-conversion

The energy-time uncertainty principle is on a different footing than the momentum position uncertainty principle: in contrast to position, time is a c-number parameter, and not an operator. As Aharonov and Bohm have pointed out, this leads to different interpretations of the two uncertainty principles. In particular, one must distinguish between an inner and an outer time in the definition of the spread in time, delta t. It is the inner time which enters the energy-time uncertainty principle. We have checked this by means of a correlated two-photon light source in which the individual energies of the two photons are broad in spectra, but in which their sum is sharp. In other words, the pair of photons is in an entangled state of energy. By passing one member of the photon pair through a filter with width delta E, it is observed that the other member's wave packet collapses upon coincidence detection to a duration delta t, such that delta E(delta t) is approximately equal to planks constant/2 pi, where this duration delta t is an inner time, in the sense of Aharonov and Bohm. We have measured delta t by means of a Michelson interferometer by monitoring the visibility of the fringes seen in coincidence detection. This is a nonlocal effect, in the sense that the two photons are far away from each other when the collapse occurs. We have excluded classical-wave explanations of this effect by means of triple coincidence measurements in conjunction with a beam splitter which follows the Michelson interferometer. Since Bell's inequalities are known to be violated, we believe that it is also incorrect to interpret this experimental outcome as if energy were a local hidden variable, i.e., as if each photon, viewed as a particle, possessed some definite but unknown energy before its detection.

Chiao, Raymond Y.