Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photoneutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Measurement of Photoneutrons from Depleted Uranium and Comparison Study Using MCNPX-PoliMi

High-energy photon interrogation is a nondestructive technique that is used to detect special nuclear materials and characterize nuclear waste. The development of such systems is complex and requires Monte Carlo simulations to optimize system performance. Monte Carlo simulations rely on various scattering, absorption, and photonuclear cross-section data. While the scattering and absorption cross-section data have been extensively studied and validated with experiments, the results obtained from photonuclear simulations are often found to underpredict measured results, indicating uncertainties in the photonuclear cross sections themselves. Thus, there is a need for new measured results that can be used to quantify underpredictions in simulations using photonuclear cross-section data. In the present work, we interrogated depleted uranium with a 9-MV electron linac and detected photoneutrons with trans-stilbene organic scintillators. The measurement of photoneutrons with organic scintillators is challenging due to the presence of the intense photon flux, which causes issues such as pulse pile-up, detector saturation, and poor signal-to-background ratio. To mitigate these challenges, we used iron and polyethylene shielding of varying thicknesses around the depleted uranium target and a neural network–based digital pulse processing algorithm to recover neutron and photon information from piled-up events. Our goal was to compare the measured photoneutron count rate with the simulated rate obtained using the MCNPX-PoliMi transport code. For a light output window of 0.28 to 2.67 MeVee (1.66- to 6.85-MeV proton recoil energy), we found that the simulated count rate obtained using the ENDF/B-VII photonuclear cross-section library underpredicts the measured rate by 32.8% 3.2%. Additionally, we compared the simulated and measured photoneutron light output distributions. For the least thicknesses of shielding, the simulation was found to underpredict measurements in the 0.70- to 2.67-MeVee light output window. For the greatest thicknesses of shielding, the simulation was found to underpredict the measurement across the entire light output window of 0.28 to 2.67 MeVee.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Photoneutron reaction cross section measurements on Mo 94 and Zr 90 relevant to the p -process nucleosynthesis

The photodisintegration cross sections for the 94 Mo(γ,n) and 90 Zr(γ,n) reactions have been experimentally investigated with quasi-monochromatic photon beams at the High Intensity γ-ray Source (HIγS) facility of the Triangle Universities Nuclear Laboratory (TUNL). The energy dependence of the photoneutron reaction cross sections was measured with high precision from the respective neutron emission thresholds up to 13.5 MeV. Here, these measurements contribute to a broader investigation of nuclear reactions relevant to the understanding of the p-process nucleosynthesis. The results are compared with the predictions of Hauser-Feshbach statistical model calculations using two different models for the dipole γ-ray strength function. Lastly, the resulting 94 Mo(γ,n) and 90 Zr(γ,n) photoneutron stellar reaction rates as a function of temperature in the typical range of interest for the p-process nucleosynthesis show how sensitive the photoneutron stellar reaction rate can be to the experimental data in the vicinity of the neutron threshold.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of the Thermal Neutron Spectrum of the W-Be Photoneutron Source of the INR RAS

The possibility of reconstructing the neutron flux density of a W-Be photoneutron source using neutron activation analysis of Ag, Mn, Fe, Mn, and Ti samples is considered. The use of simple functions as AE{sup –B}, describing particular regions of the spectrum, as a reconstruction option is discussed. The dependence of the deviation of the measured reaction rates on those calculated in this study on the parameters of approximating functions is investigated. The convergence of the reconstruction results is obtained by increasing the amount of experimental data. This reconstruction method can be used for the operational measurement of the thermal neutron flux density of the photoneutron source and for the optimization of the source parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computational study of tungsten and depleted uranium photoneutron targets for a 20 MeV electron linear accelerator

Neutron production can be realized with a high energy electron linear accelerator by using Bremsstrahlung and photoneutron converters. In this study, Monte Carlo N-Particle Code (MCNP) was used to evaluate potential photonuclear target designs for a high energy electron linear accelerator for applications such as neutron radiography and neutron resonance spectroscopy. A computational model was developed to inform a target design that would yield a high number of neutrons. It consists of a 20 MeV electron beam incident on a Bremsstrahlung target and a photonuclear target to generate neutrons. This computational model showed that a thickness of 0.75 inches for both tungsten and depleted uranium yields the most neutrons from photoneutron reactions. Saturation in the total number of generated neutrons was observed at over 0.75-inch thickness for both evaluated materials. Depleted uranium yielded approximately twice the number of neutrons overall compared to tungsten. The highest neutron surface flux for Depleted Uranium was 1.06 × 10-4 neutrons/cm2/source electron, and for Tungsten it was 5.12 × 10-5 neutrons/cm2/source electron. The optimal target design for this study’s application would consist of a 0.75 inch-thick block of depleted uranium with the length, width, and/or diameter varying dependent on application.

43 PARTICLE ACCELERATORS↗

Photoneutron Production Using an Electron Linear Accelerator for Applications in Neutron Imaging

Photoneutron production is possible using an electron linear accelerator and a target capable of generating photonuclear reactions. A short pulse neutron source can be useful for neutron imaging dynamic experiments. This study is aimed at the feasibility of photoneutron production using a 20 MeV electron linear accelerator and tungsten and depleted uranium targets of various thicknesses. MCNP6 (Monte Carlo N-Particle) code will be used to develop a computational model to estimate total neutron yield, and this will be verified at the Idaho State University’s Accelerator Center. After verification of the neutron yield and energy spectra, an additional MCNP6 model will be developed to analyze the neutron imaging processes. This study will potentially prove it is possible to conduct multi-mode imaging experiments on the anticipated Scorpius electron linear accelerator at the Nevada National Security Sites.

43 PARTICLE ACCELERATORS↗

Direct + Semidirect E1 Photoneutron Reactions: Semimicroscopic Description

The particle-hole dispersive optical model is implemented to describe together E1 photo-absorption and direct + semidirect photoneutron reactions accompanied by excitation of the giant dipole resonance. Being based on this description, a quantitative estimation of the partial and total branching ratios for direct one-neutron decay of the mentioned giant resonance in a few medium-heavy neutron-closed-shell nuclei is obtained. Calculation results are compared with corresponding experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of Extracted Beam Characteristics of the Photoneutron Source at the Institute for Nuclear Research of the Russian Academy of Sciences

The characteristics of the extracted beam of thermal neutrons at the IN-LUE photoneutron source are investigated. A collimator with a cross-section diameter of 30 mm, located at an angle of 67° relative to the electron beam direction, was used to extract neutrons from the source. The neutron flux density as a function of the distance from the source center and the distribution of flux density over the distance from the collimator axis (beam profile) are obtained.

43 PARTICLE ACCELERATORS↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of excitation functions and photoneutron cross sections of 96,98,99,104 Ru and 100 Mo

Photoneutron cross sections were extracted for isotopes of ruthenium and molybdenum on natural abundance targets via a reduced chi-squared analysis on excitation functions, or activation yields, as function of electron beam energy. Bremsstrahlung photons were produced via an electron linear accelerator and a tungsten radiator at the Idaho Accelerator Center. A total of 16 irradiations were performed with electron beam energies ranging from approximately 8 MeV to 23 MeV. Induced radioactivity was measured using a high purity germanium detector. The cross sections were extracted assuming a three parameter Lorentzian fit with a smooth truncated rise at reaction threshold.

07 - ISOTOPES AND RADIATION SOURCES↗

Low-energy nuclear recoil calibration of the LUX-ZEPLIN experiment with a photoneutron source

The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises quasi-exponentially with decreasing energy transfer to a target atom. LZ expects to detect coherent neutrino-nucleus scattering of $^{8}$B solar neutrinos, the signal from which is very similar to a dark matter particle with mass of about 5.5 GeV/$c^{2}$, which result in typical nuclear recoil energies of $<$5 keV$_{\text{nr}}$. Therefore, it is of crucial importance to calibrate the response of recoiling xenon nuclei to keV-energy recoils. This analysis details the first in situ photoneutron calibration of the LZ detector and probes its response in this energy regime.

Aalbers, J. [SLAC; Stanford U., Phys. Dept.; KIPAC↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗