Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pixel Array Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Charge Sharing and Charge Loss in a Cadmium-Zinc-Telluride Fine-Pixel Detector Array

Because of its high atomic number, room temperature operation, low noise, and high spatial resolution a Cadmium-Zinc-Telluride (CZT) multi-pixel detector is ideal for hard x-ray astrophysical observation. As part of on-going research at MSFC (Marshall Space Flight Center) to develop multi-pixel CdZnTe detectors for this purpose, we have measured charge sharing and charge loss for a 4x4 (750micron pitch), lmm thick pixel array and modeled these results using a Monte-Carlo simulation. This model was then used to predict the amount of charge sharing for a much finer pixel array (with a 300micron pitch). Future work will enable us to compare the simulated results for the finer array to measured values.

Gaskin, J. A.↗

Characterization of a 2-mm thick, 16x16 Cadmium-Zinc-Telluride Pixel Array

The detector under study is a 2-mm-thick, 16x16 Cadmium-Zinc-Telluride pixel array with a pixel pitch of 300 microns and inter-pixel gap of 50 microns. This detector is a precursor to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation. In addition, we discuss electric field modeling for this specific detector geometry and the role this mapping will play in terms of charge sharing and charge loss in the detector.

Gaskin, Jessica↗

Method for producing a hybridization of detector array and integrated circuit for readout

A process is explained for fabricating a detector array in a layer of semiconductor material on one substrate and an integrated readout circuit in a layer of semiconductor material on a separate substrate in order to select semiconductor material for optimum performance of each structure, such as GaAs for the detector array and Si for the integrated readout circuit. The detector array layer is lifted off its substrate, laminated on the metallized surface on the integrated surface, etched with reticulating channels to the surface of the integrated circuit, and provided with interconnections between the detector array pixels and the integrated readout circuit through the channels. The adhesive material for the lamination is selected to be chemically stable to provide electrical and thermal insulation and to provide stress release between the two structures fabricated in semiconductor materials that may have different coefficients of thermal expansion.

Fossum, Eric R.↗

Design of a 3-Stage ADR for the Soft X-Ray Spectrometer Instrument on the Astro-H Mission

The Japanese Astro-H mission will include the Soft X-ray Spectrometer (SXS) instrument, whose 36-pixel detector array of ultra-sensitive x-ray microcalorimeters requires cooling to 50 mK. This will be accomplished using a 3-stage adiabatic demagnetization refrigerator (ADR). The design is dictated by the need to operate with full redundancy with both a superfluid helium dewar at 1.3 K or below, and with a 4.5 K Joule-Thomson (JT) cooler. The ADR is configured as a 2-stage unit that is located in a well in the helium tank, and a third stage that is mounted to the top of the helium tank. The third stage is directly connected through two heat switches to the JT cooler and the helium tank, and manages heat flow between the two. When liquid helium is present, the 2-stage ADR operates in a single-shot manner using the superfluid helium as a heat sink. The third stage may be used independently to reduce the time-average heat load on the liquid to extend its lifetime. When the liquid is depleted, the 2nd and 3rd stages operate as a continuous ADR to maintain the helium tank at as low a temperature as possible - expected to be 1.2 K - and the 1st stage cools from that temperature as a single-stage, single-shot ADR. The ADR s design and operating modes are discussed, along with test results of the prototype 3-stage ADR.

Shirron, Peter J.↗

Adaptive Wavelength Scanning Lidar (AWSL) for 3D Mapping from Space

We present the design and performance of an adaptive wavelength scanning lidar (AWSL) for highly efficient mapping from low Earth orbit (LEO). Mapping is accomplished by steering a laser beam across 1,200 resolvable spots using wavelength tuning and grating dispersion. Any subset of these 1,200 spots can be selected by wavelength switching. The design is validated with an 1550-nm prototype using a fast wavelength-tuned (500-kHz) pulsed (2-ns) fiber laser with the beam dispersed by gratings for beam steering. Reflected pulses are detected with an eight-pixel detector array with single-photon sensitivity. Eight lidar returns are time-multiplexed to one output that is digitized with a single 1-GSPS-digitizer, to save power. A grating spectrometer rejects solar background noise spatially and spectrally, and images laser footprints on to the detector array. The gratings retain the fiber laser beam quality. We are developing a 1030-nm AWSL intended for a LEO SmallSat platform.

Guangning Yang↗

Development of Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System (CASALS) for Swath Mapping From Space

We present the design and performance of a Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS) for 3D imaging from Space. With a single fast wavelength tuning laser, CASALS accomplishes a 1,200 resolvable spots swath mapping by grating dispersion wavelength steering. Any subset of these 1,200 spots can be selected by wavelength switching. The validation operating principle was accomplished and reported in IGASS-2022. With configurable base design, we report the designs and progress of the CASALS airplane campaign with 256 contiguous ground spots. It is accomplished with a single fast tuning lase at 1040-nm, 1.152MHz tuning rate, and pulse modulated 2-ns on each wavelength. Return pulses are mapped to an eight-pixel detector array with single-photon sensitivity. The lidar returns are time-multiplexed to two outputs that are digitized with two 1-GSPS-digitizer. A grating spectrometer rejects solar background noise spatially and spectrally. We are developing a 1040-nm CASALS intended for multiple LEO orbit missions: Earth Venture Mission on ESPA Grande, STV Mission on ESPA Grande SmallSat, STV Mission on spacecraft equivalent to ICESat power (SWaP,) and splitting the laser beam requires higher laser pulse energy.

ranging lidar↗

Fabrication of Pop-up Detector Arrays on Si Wafers

High sensitivity is a basic requirement for a new generation of thermal detectors. To meet the requirement, close-packed, two-dimensional silicon detector arrays have been developed in NASA Goddard Space Flight Center. The goal of the task is to fabricate detector arrays configured with thermal detectors such as infrared bolometers and x-ray calorimeters to use in space fliGht missions. This paper focuses on the fabrication and the mechanical testing of detector arrays in a 0.2 mm pixel size, the smallest pop-up detectors being developed so far. These array structures, nicknamed "PUDS" for "Pop-Up Detectors", are fabricated on I pm thick, single-crystal, silicon membranes. Their designs have been refined so we can utilize the flexibility of thin silicon films by actually folding the silicon membranes to 90 degrees in order to obtain close-packed two-dimensional arrays. The PUD elements consist of a detector platform and two legs for mechanical support while also serving as electrical and thermal paths. Torsion bars and cantilevers connecting the detector platform to the legs provide additional flexures for strain relief. Using micro-electromechanical structure (MEMS) fabrication techniques, including photolithography, anisotropic chemical etching, reactive-ion etching, and laser dicing, we have fabricated PLTD detector arrays of fourteen designs with a variation of four parameters including cantilever length, torsion bar length and width, and leg length. Folding tests were conducted to test mechanical stress distribution for the array structures. We obtained folding yields and selected optimum design parameters to reach minimal stress levels. Computer simulation was also employed to verify mechanical behaviors of PUDs in the folding process. In addition, scanning electron microscopy was utilized to examine the flatness of detectors and the alignment of detector pixels in arrays. The fabrication of thermistors and heaters on the pop-up detectors is under way, preparing us for the next step of the experiment, the thermal test.

Li, Mary J.↗

Order-sorting filter transmittance measured with an array detector

The simultaneous measurement of the spectrally and spatially variant transmittance of a linear variable order-sorting filter in a manner that closely resembles its conditions of actual use is described. The transmittance of a prototype order-sorting filter was measured in the 400- to 880-nm wavelength region by illuminating it with the output beam of a spectrophotometer while the filter was attached to the front of a 30 x 32 pixel silicon array detector. The filter was designed to be used in the output beam of a grating spectrometer to prevent the dispersal of higher diffracted orders onto an array detector. Areas of the filter that were spatially matched to the corresponding detector pixel column had measured peak transmittances of about 90 percent that were uniform to within +/- 1.5 percent along a given column. Transmittances for incident wavelengths shorter than the desired bandpass, corresponding to the order overlap region, were measured in the 0.003 range. Line spread function measurements made with the array detector indicated no significant beam spreading caused by inserting the filter into the beam.

Heaney, James B.↗

Mid-infrared detector development for the Origins Space Telescope

Mid-infrared detector arrays operating from 2.8 to 20 μm are baselined in the design of the Origins Space Telescope Mid-Infrared Spectrometer Instrument. This instrument is designed to detect and measure the spectral signatures of gases of biogenic origin in the atmospheres of exoplanets as they transit their host stars. In order to make these detections, the detector array’s pixels need to have high-signal stability when exposed to a constant flux in multiple time-series integration over a typical transit time of a few hours. With the use of a densified pupil spectrometer design, pointing effects can be mitigated because pointing variations do not displace spectra on the detector and each wavelength of light is averaged over a large number of pixels, giving good spectrophotometric stabilities. The current state-of-the-art detector arrays do not achieve these stabilities, although with a feasible development program this level of performance should be achievable. Three detector technologies are under consideration for this development, HgCdTe arrays, Si:As impurity band conduction arrays, and transition edge super-conductor bolometer arrays. We primarily treat the HgCdTe technology development, but also introduce the paths forward for the other two technologies. After a few years-long investigative programs, a down-select will be undertaken to select the flight technology.

Astronomy↗

Downsampling Photodetector Array with Windowing

In a photon counting detector array, each pixel in the array produces an electrical pulse when an incident photon on that pixel is detected. Detection and demodulation of an optical communication signal that modulated the intensity of the optical signal requires counting the number of photon arrivals over a given interval. As the size of photon counting photodetector arrays increases, parallel processing of all the pixels exceeds the resources available in current application-specific integrated circuit (ASIC) and gate array (GA) technology; the desire for a high fill factor in avalanche photodiode (APD) detector arrays also precludes this. Through the use of downsampling and windowing portions of the detector array, the processing is distributed between the ASIC and GA. This allows demodulation of the optical communication signal incident on a large photon counting detector array, as well as providing architecture amenable to algorithmic changes. The detector array readout ASIC functions as a parallel-to-serial converter, serializing the photodetector array output for subsequent processing. Additional downsampling functionality for each pixel is added to this ASIC. Due to the large number of pixels in the array, the readout time of the entire photodetector is greater than the time between photon arrivals; therefore, a downsampling pre-processing step is done in order to increase the time allowed for the readout to occur. Each pixel drives a small counter that is incremented at every detected photon arrival or, equivalently, the charge in a storage capacitor is incremented. At the end of a user-configurable counting period (calculated independently from the ASIC), the counters are sampled and cleared. This downsampled photon count information is then sent one counter word at a time to the GA. For a large array, processing even the downsampled pixel counts exceeds the capabilities of the GA. Windowing of the array, whereby several subsets of pixels are designated for processing, is used to further reduce the computational requirements. The grouping of the designated pixel frame as the photon count information is sent one word at a time to the GA, the aggregation of the pixels in a window can be achieved by selecting only the designated pixel counts from the serial stream of photon counts, thereby obviating the need to store the entire frame of pixel count in the gate array. The pixel count se quence from each window can then be processed, forming lower-rate pixel statistics for each window. By having this processing occur in the GA rather than in the ASIC, future changes to the processing algorithm can be readily implemented. The high-bandwidth requirements of a photon counting array combined with the properties of the optical modulation being detected by the array present a unique problem that has not been addressed by current CCD or CMOS sensor array solutions.

Patawaran, Ferze D.↗

Design, Fabrication, and Testing of a TiN Ti TiN Trilayer KID Array for 3mm CMB Observations

Kinetic inductance detectors (KIDs) are a promising technology for astronomical observations over a wide range of wavelengths in the mm and sub-mm regime. Simple fabrication, in as little as one lithographic layer, and passive frequency-domain multiplexing, with readout of up to 1000 pixels on a single line with a single cold amplifier, make KIDs an attractive solution for high-pixel-count detector arrays. We are developing an array that optimizes KIDs for optical frequencies near 100GHz to expand their usefulness in mm-wave applications, with a particular focus on CMBB-mode measurement efforts in association with the QUBIC telescope. We have designed, fabricated, and tested a 20-pixel prototype array using a simple quasi lumped microstrip design and pulsed DC reactive magnetron-sputtered TiNTiTiN trilayer resonators, optimized for detecting 100GHz (3mm) signals. Here we present a discussion of design considerations for the array, as well as preliminary detector characterization measurements and results from a study of TiN trilayer properties.

passive frequency-domain multiplexing↗

Method for the Absolute Calibration of the Location and Orientation of Large-Format Detectors Using Laser Radar

A method of mapping pixel locations of a detector array includes measuring a location on the detector array, initiating a frame readout of the detector array, measuring a location of one or more metrology targets on the detector array, analyzing the frame readout to identify a pixel at the location on the detector array, and defining a location of the identified pixel with respect to the location of the one or more metrology targets. Subsequent measurement of the metrology targets alone by another metrology system allows one to infer the six degree of freedom alignment of the detector array in space.

Coulter, Phillip↗

The AstroBiology Explorer (ABE) MIDEX Mission Concept: Identifying Organic Molecules in Space

The Astrobiology Explorer (ABE) is a MIDEX mission concept, currently under Concept Phase A study at NASA's Ames Research Center in collaboration with Ball Aerospace & Technologies, Corp., and managed by NASA's Jet Propulsion Laboratory. ABE will conduct infrared spectroscopic observations to address important problems in astrobiology, astrochemistry, and astrophysics. The core observational program would make fundamental scientific progress in understanding the distribution, identity, and evolution of ices and organic matter in dense molecular clouds, young forming stellar systems, stellar outflows, the general diffuse ISM, HII regions, Solar System bodies, and external galaxies. The ABE instrument concept includes a 0.6 m aperture Ritchey-Chretien telescope and three moderate resolution (R = 2000-3000) spectrometers together covering the 2.5-20 micron spectral region. Large format (1024 x 1024 pixel) IR detector arrays will allow each spectrometer to cover an entire octave of spectral range per exposure without any moving parts. The telescope will be cooled below 50 K by a cryogenic dewar shielded by a sunshade. The detectors will be cooled to approx. 7.5 K by a solid hydrogen cryostat. The optimum orbital configuration for achieving the scientific objectives of the ABE mission is a low background, 1 AU Earth driftaway orbit requiring a Delta II launch vehicle. This configuration provides a low thermal background and allows adequate communications bandwidth and good access to the entire sky over the approx. 1.5 year mission lifetime.

Ennico, Kimberly↗

Kepler Instrument Performance: An In-Flight Update

The Kepler Mission is designed to detect the 80 parts per million (ppm) signal from an Earth-Sun equivalent transit. Such precision requires superb instrument stability on time scales up to 2 days and systematic error removal to better than 20 ppm. The sole scientic instrument is the Photometer, a 0.95 m aperture Schmidt telescope that feeds the 94.6 million pixel CCD detector array, which contains both Science and Fine Guidance Sensor (FGS) CCDs. Since Kepler's launch in March 2009, we have been using the commissioning and science operations data to characterize the instrument and monitor its performance. We find that the in-flight detector properties of the focal plane, including bias levels, read noise, gain, linearity, saturation, FGS to Science crosstalk,and video crosstalk between Science CCDs, are essentially unchanged from their pre-launch values. Kepler'sunprecedented sensitivity and stability in space have allowed us to measure both short- and long- term effects from cosmic rays, see interactions of previously known image artifacts with starlight, and uncover several unexpected systematics that affect photometric precision. Based on these results, we expect to attain Kepler's planned photometric precision over 90% of the field of view.

CCD↗

An Array of Frequency Selective Bolometers (FSB) for the Spectral Energy Distribution (SPEED) Camera

The SPEED camera is being developed to study the spectral energy distributions of high redshift galaxies using the Heinrich Hertz Telescope (HHT) in Arizona. SPEED requires a small cryogenic detector array of 2x2 pixels with each pixel having four frequency bands in the 150-350 GHz range. Here we describe the development of the detector array of these high efficiency FSBs. The FSB design provides the multi-pixel multi-spectral band capability required for SPEED in a compact stackable array. The SPEED bolometers will use proximity effect superconducting transition edge sensors as their temperature-sensing element allowing for higher levels of multiplexing in future applications.

Silverberg, R. F.↗

MTRAP: The Magnetic Transition Region Probe

The Magnetic Transition Region Probe is a space telescope designed to measure the magnetic field at several heights and temperatures in the solar atmosphere, providing observations spanning the chromospheric region where the field is expected to become force free. The primary goal is to provide an early warning system (hours to days) for solar energetic particle events that pose a serious hazard to astronauts in deep space and to understand the source regions of these particles. The required magnetic field data consist of simultaneous circular and linear polarization measurements in several spectral lines over the wavelength range from 150 to 855 nm. Because the observations are photon limited an optical telescope with a large (>18sq m) collecting area is required. To keep the heat dissipation problem manageable we have chosen to implement MTRAP with six separate Gregorian telescopes, each with approx. 3 sq m collecting area, that are brought to a common focus. The large field of view (5 x 5 arcmin(sup 2)) and angular resolution (0.025 arcsec pixels) require large detector arrays and, because of the requirements on signal to noise (10(exp 3)), pixels with large full well depths to reduce the readout time and improve the temporal resolution. The optical and engineering considerations that have gone into the development of a concept that meets MTRAP's requirements are described.

Davis, J. M.↗

Status of the Micro-X Sounding Rocket X-Ray Spectrometer

Micro-X is a sounding rocket borne X-ray telescope that utilizes transition edge sensors to perform imaging spectroscopy with a high level of energy resolution. Its 2.1m focal length X-ray optic has an effective area of 300 sq cm, a field of view of 11.8 arcmin, and a bandpass of 0.12.5 keV. The detector array has 128 pixels and an intrinsic energy resolution of 4.5 eV FWHM. The integration of the system has progressed with functional tests of the detectors and electronics complete, and performance characterization of the detectors is underway. We present an update of ongoing progress in preparation for the upcoming launch of the instrument.

X-ray astronomy↗