Use of impedance plethysmography in aerospace medicine
An impedance-plethysmographic technique is described which can be used to quantify temporal bone-marrow blood-flow changes. Results obtained with the impedance technique compare favorably with the data from simultaneously administered microspheres. Injection of sympathomimetic drugs produced measurable responses: isoproterenol caused a significant increase in bone-marrow blood flow within 1 min, and levarterenol decreased bone-marrow blood flow. Data obtained with impedance plethysmography suggest that the technique is feasible for multiple measurements on the same animal and that the technique can be used to study acute or chronic changes in bone-marrow blood flow following various experimental treatments.
Clinical and experimental use of thoracic impedance plethysmography in quantifying myocardial contractility
Calibration of electrical impedance plethysmograph for blood flow monitoring
EVALUATION OF SYSTOLIC THORACIC IMPEDANCE CHANGES and duration of ejection
A rigid band electrode system is described which facilitates location of the recording electrodes of a tetrapolar impedance plethysmograph used for measuring pulsations of blood in a finger segment. The electrodes can be relocated accurately, and the volume of the finger segment under study can be precisely defined. The new system ensures good electrical contact and minimizes movement artifacts in the plethysmograph trace by holding the finger segment in a firm position.
Definition of multi-segmental circulatory and volume changes in the human body provides an understanding of the physiologic responses to various aerospace conditions. We have developed instrumentation and testing procedures at NASA Ames Research Center that may be useful in biomedical research and clinical diagnosis. Specialized two, four, and six channel impedance systems will be described that have been used to measure calf, thigh, thoracic, arm, and cerebral hemodynamic and volume changes during various experimental investigations.
Changes in blood flow and blood redistribution were measured by impedance plethysmography in the pelvic and leg regions of six male and four female subjects during three 5-min exposures to -20, -40, and -60 mm Hg lower body negative pressure (LBNP). Female subjects demonstrated significantly higher mean heart rate and lower leg blood flow indices than the male subjects during the recumbent control periods. Men had slightly higher mean resting systolic and diastolic blood pressures and higher mean control pelvic blood indices. Women demonstrated significantly less blood pooling in the legs and slightly less in the pelvic region than the men. All of the 18 tests with male subjects at -60 mm Hg were completed without initial signs of syncope, while only two of the tests with women were completed successfully without the subject exhibiting presyncopal conditions. Results indicate that impedance plethysmography can be used to measure segmental cardiovascular responses during LBNP and that females may be less tolerant to -60 mm Hg LBNP than males.
The peripheral (tail) circulatory responses of six male albino rats were measured at ambient temperatures between 5 and 40 C, using impedance plethysmography. Each animal was anesthetized, instrumented, and placed in a thermal environmental chamber to reach equilibrium. Tail blood flow, respiration rate, heart rate, core temperature, and tail skin temperature were then monitored at each ambient temperature. The mean tail blood flow was significantly higher (p less than 0.05) at 5 C than at 10 C. The mean blood flow increased significantly (p less than 0.01) at each of the temperatures above 10 C. Tail skin temperature and internal body (core) temperature increased significantly with increasing ambient temperature.
BACKGROUND: We measured the three-dimensional ballistocardiogram (BCG) in a free-floating subject in sustained microgravity during spaceflight to test the usefulness of such measurements for future non-invasive monitoring of cardiac function, and to examine the effects of respiratory movement on the BCG in three axes. METHODS: Acceleration was measured using a three-axis accelerometer fastened to the lumbar region of the subject while simultaneous recordings of ECG, and respiratory motion via impedance plethysmography were also made. Data were recorded during a 146-s period of inactivity on the part of the subject during which time there was no contact with the spacecraft. RESULTS: Total body motion due to respiratory activity was consistent with that calculated from the known action of the diaphragm and conservation of momentum. The accelerations due to cardiac activity, ensemble averaged over the R-R interval, were greatest along the head-to-foot axis. Maximum amplitude of the HIJK complex of the BCG generated by ventricular ejection was greatest in the head to foot axis (approximately 70 x 10(-3) m x s(-2)), but there were also substantial accelerations along the dorsoventral axis of up to 43 10(-3) m x s(-2), that are not measured interrestrial two-dimensional studies. The amplitude of the BCG was strongly affected by lung volume, with accelerations being reduced 50 to 70% between end-inspiration and end-expiration. CONCLUSIONS: These data suggest a greatly reduced transmission of the cardiac motion to the body at end-expiration (FRC) than at higher lung volumes. The BCG might be further developed as a non-invasive means of monitoring parameters such as stroke volume in microgravity.
A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.
Eight subjects participated in one control and three rotation trials on a short-arm centrifuge such that the Gz levels at the feet were 0.5, 1.0, and 1.5 G. Trials consisted of 30 minutes of supine rest, 1 hour of rotation (or in the control, 30 additional minutes of rest and 30 minutes of standing), and a final 30-minute rest period. Measurements of heart rate, calf impedance, calf volume, and blood pressure support the findings that the highest G level is similar to standing and that the lower G levels fail to produce significant effects.
Forearm, hand, and finger blood flow (impedance) changes are measured by impedance rheography on seven healthy male subjects aged 20-35 yr during exposure to ambient temperatures ranging from 10 to 46 C. All observations are made in an environmental chamber at a dew point temperature of 13 + or - 0.25 C. It is shown that impedance rheography is suitable for quantifying peripheral circulatory responses to thermal stress. The measured blood flow indices are found to be consistent with previously reported values for the forearm, hand, and fingers obtained using air or water displacement plethysmography. In particular, the more distal body segments exhibit relatively larger vasomotor responses to changes in ambient temperature than do the more proximal body segments.
The design, construction, and performance characteristics of ultasonic transducers suitable for limb plethysmography are presented. Both 3-mm-diameter flat-plate and 12-mm-diameter hemispheric ceramic transducers operating at 2 MHz were fitted in 1-mm thick epoxy-resin lens/acoustic-coupling structures and mounted in exercie-EKG electrode housings for placement on the calf using adhesive collars. The effects of transducer directional characteristics on performance under off-axis rotation and the electrical impedances of the transducers were measured: The flat transducer was found to be sensitive to rotation and have an impedance of 800 ohms; the hemispheric transducer, to be unaffected by rotation and have an impedance of 80 ohms. The use of hemispheric transducers as both transmitter and receiver, or of a flat transducer as transmitter and a hemispheric transducer as receiver, was found to produce adequate dimensional measurements, with minimum care in transducer placement, in short-term physiological experiments and long-term (up to 7-day) attachment tests.