Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polarimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Double Image Polarimeter—Ultra Fast: Simultaneous Three-color (BVR) Polarimeter with Electron-multiplying Charge-coupled Devices

We describe a new instrument capable of high-precision (10{sup −5}) polarimetric observations simultaneously in three passbands (BVR). The instrument utilizes electron-multiplying charge-coupled device (EM CCD) cameras for high efficiency and fast image readout. The key features of the Double Image Polarimeter—Ultra Fast (DIPol-UF) are: (i) the optical design with high throughput and inherent stability; (ii) great versatility, which makes the instrument optimally suitable for observations of bright and faint targets; and (iii) a control system, which allows the use of the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observations of bright nearby stars and of fainter sources such as X-ray binaries in their quiescent states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

280 GHz Focal Plane Unit Design and Characterization for the Spider-2 Suborbital Polarimeter

We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne Spider instrument. These FPUs are vital to Spider’s primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a $16 \times 16$ grid of corrugated silicon feedhorns coupled to an array of aluminum–manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1530 polarization-sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper, we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be $\sim $ 3 pW at 300 mK with a less than 6% variation across each array at $1\sigma $ . These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the Spider-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

An absolute recoil-carbon polarimeter for polarized light-ions at the BNL Booster

We describe a recoil-carbon polarimeter for the BNL Booster synchrotron capable of measuring the transverse polarization of both the polarized proton beam and the polarized 3 He ion beam throughout the acceleration cycle. The instrument addresses a critical gap in the BNL polarized beam program: no independent polarization measurement currently exists in the injector chain between the 200 MeV Linac polarimeter and the AGS. The proposed new polarimeter will provide continuous, absolute polarization measurements at the Booster stage, supplying additional anchor points for the polarization transmission through the accelerator chain. The polarimeter 9 is based on elastic pC and 3 He C scattering from a thin internal carbon target, with detection of the recoil 12 C nucleus in a fixed six-station silicon detector ring. A single detector geometry provides continuous kinematic coverage from injection to extraction for both beam species without mechanical adjustment. For pC scattering, the available data and the Bonin parametrization provide a well-established basis for estimating the analyzing power and figure of merit over the Booster energy range; for 3 He C the sole experimental anchor is a measurement at 443 MeV, and the Booster polarimeter itself is identified as the instrument to map the analyzing power across the remainder of the acceleration ramp by a ramp-and-return calibration that anchors the absolute 3 He polarization scale to a few percent. Provision for future deuteron polarimetry is incorporated in the chamber design without modification to the existing geometry. With appropriate detector upgrades, the same recoil-carbon technique can be extended to deuteron beams, for which analyzing power data are already available, and, with future analyzing-power measurements, also to 6 Li and 7 Li beams, making the polarimeter a versatile instrument for the full range of light polarized ion species anticipated at BNL.

43 PARTICLE ACCELERATORS↗

Tests of a full-scale ITER toroidal interferometer and polarimeter (TIP) prototype on the DIII-D tokamak (invited)

A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 μm and 5.22 μm using a CO 2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 μm. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05° (100 Hz bandwidth) and 1.9° (1 kHz bandwidth), respectively. Here, the corresponding line-integrated density resolution for the vibration-compensated interferometer is δnL = 1.5 × 10 18 m -2 , and the magnetic field-weighted line-integrated density from the polarimeter is δnBL = 1.5 × 10 19 Tm -2 . Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfvén eigenmodes and tearing modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlation polarimeter-interferometer in the DIII-D tokamak

A correlation polarimeter-interferometer system has been developed for the DIII-D tokamak to detect small amplitude magnetic and density fluctuations. Two collinear, frequency-offset (5–15 MHz), orthogonally polarized (right- and left-handed, circularly polarized) electromagnetic waves at 650 GHz probing the plasma are used to detect the Faraday effect. A third, linearly polarized, electromagnetic wave serves as the local-oscillator to provide a measure of the line-averaged density. Correlation polarimetric measurement is accomplished by correlating the Faraday effect measured along the same line of sight using two independent detectors, whereas simultaneous correlation interferometric measurement is realized by correlating the line-averaged density measured at two different intermediate frequencies. The noise floor of the correlation polarimeter-interferometer has been demonstrated to be more than one order of magnitude lower than that of a standard polarimeter-interferometer measurement. Line-averaged correlation polarimetric-interferometric measurements in DIII-D H-mode plasmas show broadband (up to 750 kHz) magnetic and density fluctuations with amplitudes as low as 0.03 $Gauss$/$\sqrt{kHz}$ and 4 × 10 13 m –3 /$\sqrt{kHz}$, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Complete Stokes vector analysis with a compact, portable rotating waveplate polarimeter

Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.

47 OTHER INSTRUMENTATION↗

Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC

The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 (E beam = 100 GeV) and 17 (255 GeV). For a typical 8 hour RHIC store, the measured proton beam average polarization was about P beam ~ 55 ± 2.0 stat ± 0.3 syst %. The elastic pp analyzing power, AN(t)~0.04, was determined with a precision of about |δA N (t)|~0.0002 in the momentum transfer squared range 0.001<-t<0.020 GeV 2 . In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.

43 PARTICLE ACCELERATORS↗

Estimating Residual Gas Beam Loss in the BNL AGS Booster:Model, Numerical Tools, and Implications for a Polarimeter Chamber

Beamloss from residual gas scattering is calculated for a storage ring of circumference C = 200m, covering a linear magnetic rigidity ramp from B ρ inj = 1.25Tm to B ρ ext = 9.50Tm over tramp = 1.00s. Three loss mechanisms are considered: nuclear inelastic reactions, single Coulomb scattering beyond the acceptance angle of the machine, and charge-state exchange for heavy ions. Calculations are performed for protons and Au 32+ ions, the latter being the charge state delivered by the EBIS pre-injector into the BNL AGS Booster. At a baseline vacuum of P 0 = 5 × 10 −11 mbar the integrated fractional beam loss over the full ramp is negligible for protons (< 0.001%) and 33.1% for Au 32+ . The impact of a 1m polarimeter section at elevated pressure P s = 5 × 10 −9 mbar is evaluated: the proton loss remains negligible, while the Au 32+ loss rises to 45.1%, establishing the vacuum requirement for the polarimeter chamber. In the present compact approximate model, Au 32+ losses are dominated by charge exchange at injection, while proton losses are dominated by single Coulomb scattering. The design, outgassing budget, pumping strategy, and commissioning sequence for a UHV polarimeter chamber housing silicon detectors and ASICs are described in detail.

43 PARTICLE ACCELERATORS↗

Spin Diagnostics Using Mott Polarimeter for the EIC Pre-Injector

Polarization measurement and front-end commissioning are critical steps in the EIC preinjector program. We designed a spin-diagnostics beamline at around 4 MeV for front-end commissioning. This paper describes a high-energy Mott polarimeter, including Mott scattering, the Sherman function, and extrapolation toward single elastic scattering in finite-thickness foils. We summarize the key equations used to calculate essential design parameters, including detection time, effective Sherman function, differential cross section, and Mott polarimeter figure of merit. We also present the diagnostics beamline lattice design and kicker design for continuous spin-polarization monitoring. These notes provide concepts, formulas, and methods for diagnostic-beamline design and commissioning measurements.

43 PARTICLE ACCELERATORS↗

A Faraday-effect polarimeter for fast magnetic dynamics measurement on DIII-D

A Faraday-effect-based radial-interferometer-polarimeter diagnostic has been developed to explore fast magnetic dynamics in high-performance DIII-D plasmas. The instrument measures radial magnetic field perturbations using three chords positioned near the magnetic axis. Newly developed solid-state sources operating at 650 GHz provide phase noise down to 0.01°/$\sqrt{kHz}$ and tunable bandwidth up to 10 MHz. Various systematic errors which can contaminate the polarimetric measurement have been investigated in detail. Distortion of circular polarization due to non-ideal optical components is calibrated using a rotating quarter wave plate technique. The impact of perpendicular magnetic field, i.e., the Cotton-Mouton effect, is evaluated. The error due to non-collinearity of probe beams is minimized to less than 0.5° for electron density up to 7 × 10 19 m -3 by alignment optimization. Optical feedback, due to multiple reflections induced by the double-pass configuration, is identified and reduced. Lastly, coherent and broadband high-frequency magnetic fluctuations for DIII-D H-mode plasmas are observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design study of a combined interferometer and polarimeter for a high-field, compact tokamak

This article is the first design study of a combined interferometer and polarimeter on a compact, high-field, high-density, net-energy tokamak. Recent advances in superconducting technology have made possible designs for compact, high magnetic field fusion power plants, such as ARC [Sorbom et al., Fusion Eng. Des. 100, 378 (2015)], and experiments, such as SPARC [Greenwald et al., PSFC Report No. RR-18-2 (2018)]. These new designs create both challenges and opportunities for plasma diagnostics. The diagnostic proposed in this work, called InterPol, takes advantage of unique opportunities provided by high magnetic field and density to measure both line-averaged density and poloidal magnetic field with a single set of CO 2 and quantum cascade lasers. These measurements will be used for fast density feedback control, constraint of density and safety factor profiles, and density fluctuation measurements. Synthetic diagnostic testing using a model machine geometry, called MQ1 (Mission Q ≥ 1), and profiles simulated with Tokamak Simulation Code indicate that InterPol will be able to measure steady state density and poloidal magnetic field, as well as fluctuations caused by toroidal Alfven eigenmodes and other phenomena on a high-field compact tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrade of DIII-D radial interferometer–polarimeter for large bandwidth, low noise, and toroidal mode number measurements

Near ion-cyclotron frequency (f ci ) fluctuations, such as those originating from Global and Compressional Alfvén Eigenmodes (GAEs/CAEs), are expected to be present in future fusion reactors but are not well understood due to the limited availability of core measurements in present-day tokamaks. The measurement bandwidth of the Radial Interferometer–Polarimeter (RIP) diagnostic has been upgraded from 1 to 5 MHz to detect these fluctuations in DIII-D. RIP adopts the three-wave technique for simultaneous polarimetric and interferometric measurements. Solid-state microwave sources operating at 650 GHz are used as probe beams and provide 5 MHz bandwidth for both polarimetric and interferometric measurements. Bandwidths of related hardware, including mixer amplifier, signal cable, and digital phase demodulator, are increased correspondingly. Measurement noise is minimized by reducing the time delay between reference and probe signals to nanosecond level and employing correlation-based techniques. Using the upgraded diagnostic, CAE/GAE-like bursting fluctuations are observed in neutral-beam heated plasmas with toroidal magnetic field B φ ≈ 1 T. Current upgrades being undertaken would enable the evaluation of toroidal mode number for these modes. Furthermore, this work opens the possibility of better understanding near ion-cyclotron frequency fluctuations in fusion relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of radial interferometer–polarimeter for internal magnetic and density fluctuation measurements at multiple space–time scales in the National Spherical Torus Experiment-Upgrade (NSTX-U)

A Faraday-effect radial interferometer–polarimeter is designed for the National Spherical Torus Experiment-Upgrade (NSTX-U) to measure multiscale magnetic and density fluctuations critical to understanding fusion plasma confinement and stability, including those originating from magnetohydrodynamic instabilities, energetic particle-driven modes, and turbulence. The diagnostic will utilize the three-wave technique with 5 MHz bandwidth to simultaneously measure line-integrated magnetic and density fluctuations up to the ion-cyclotron frequency. Probe beams will be launched radially from the low-field side at the NSTX-U midplane, where the measured Faraday fluctuations mainly correspond to radial magnetic fluctuations that directly link to magnetic transport. A correlation technique will be employed to reduce the measurement noise to below 0.01° enabling detection of small amplitude fluctuations. Two toroidally displaced chords with 7° separation will be installed to measure toroidal mode numbers up to n = 25 for mode identification. Finally, solid-state microwave sources operating at 321 μm (935 GHz) will be used to minimize the impact of the Cotton–Mouton effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic simulations compared with magnetic fluctuations diagnosed with a Faraday-effect radial interferometer-polarimeter in the DIII-D pedestal

Abstract Experimental data on electromagnetic fluctuations in DIII-D, made available by the Faraday-effect radial interferometer-polarimeter (RIP) diagnostic Chen (2016 Rev. Sci. Instrum. 87 11E108), is examined in comparison with detailed gyrokinetic simulations using gyrokinetic electromagnetic numerical experiment (GENE). The diagnostic has the unique capability of making internal measurements of fluctuating magnetic fields ∫ n e δ B r d R ∫ n e d R . Local linear simulations identify microtearing modes (MTMs) over a substantial range of toroidal mode numbers (peaking at n = 15) with frequencies in good agreement with the experimental data. Local nonlinear simulations reinforce this result by producing a magnetic frequency spectrum in good agreement with that diagnosed by RIP. Simulated heat fluxes are in the range of experimental expectations. However, magnetic fluctuation amplitudes are substantially lower than the experimental expectations. Possible sources of this discrepancy are discussed, notably the fact that the diagnostics are localized at the mid-plane—the poloidal location where the simulations predict the fluctuation amplitudes to be smallest. Despite some discrepancies, several connections between simulations and experiments, combined with general criteria discriminating between potential pedestal instabilities, strongly point to MTMs as the source of the observed magnetic fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Algorithm to Calibrate and Correct the Response to Unpolarized Radiation of the X-Ray Polarimeter Onboard IXPE

The Gas Pixel Detector (GPD) is an X-ray polarimeter to fly onboard IXPE and other missions. To correctly measure the source polarization, the response of IXPE’s GPDs to unpolarized radiation has to be calibrated and corrected. In this paper, we describe the way such response is measured with laboratory sources and the algorithm to apply such correction to the observations of celestial sources. The latter allows to correct the response to polarization of single photons, therefore allowing great flexibility in all the subsequent analysis. Our correction approach is tested against both monochromatic and nonmonochromatic laboratory sources and with simulations, finding that it correctly retrieves the polarization up to the statistical limits of the planned IXPE observations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗