Development of real-time rotating waveplate Stokes polarimeter using multi-order retardation for ITER poloidal polarimeter

The rotating waveplate Stokes polarimeter was developed for ITER (International Thermonuclear Experimental Reactor) poloidal polarimeter. The generalized model of the rotating waveplate Stokes polarimeter and the algorithm suitable for real-time field-programmable gate array (FPGA) processing were proposed. Since the generalized model takes into account each component associated with the rotation of the waveplate, the Stokes parameters can be accurately measured even in unideal condition such as non-uniformity of the waveplate retardation. Experiments using a He-Ne laser showed that the maximum error and the precision of the Stokes parameter were 3.5% and 1.2%, respectively. The rotation speed of waveplate was 20 000 rpm and time resolution of measuring the Stokes parameter was 3.3 ms. Software emulation showed that the real-time measurement of the Stokes parameter with time resolution of less than 10 ms is possible by using several FPGA boards. Evaluation of measurement capability using a far-infrared laser which ITER poloidal polarimeter will use concluded that measurement error will be reduced by a factor of nine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The X-Ray Polarimeter Instrument on Board the Polarimeter for Relativistic Astrophysical X-Ray Sources (PRAXyS) Mission

The Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) is one of three Small Explorer (SMEX) missions selected by NASA for Phase A study. The PRAXyS observatory carries an X-ray Polarimeter Instrument (XPI) capable of measuring the linear polarization from a variety of high energy sources, including black holes, neutron stars, and supernova remnants. The XPI is comprised of two identical mirror-Time Projection Chamber (TPC) polarimeter telescopes with a system effective area of 124 sq cm at 3 keV, capable of photon limited observations for sources as faint as 1 mCrab. The XPI is built with well-established technologies. This paper will describe the performance of the XPI flight mirror with the engineering test unit polarimeter

polarization↗

SWIRP (Submm-Wave and Long Wave InfraRed Polarimeter); Development and Characterization of a Sub-Mm Polarimeter for Ice Cloud Investigations

A major source of uncertainty in climate models is the presence, shape and distribution of ice particles in the uppermost layers of the clouds. The effects of this component are poorly constrained, turning ice particles into an almost-free variable in many climate models.NASA-GSFC is developing a new instrument aimed at measuring the size and shape of ice particles. The instrument consists of two sub-mm polarimeters (at 220 and 670 GHz) coupled with a long-wave infrared polarimeter at 10 micron. Each polarimeter has identical V-pol and H-pol channels; the axes of polarization are defined geometrically by the orientation of the waveguide elements, and the purity has been measured in the lab. The instrument is configured as a conical scanner, suitable for deployment as a payload on a small satellite or on a high-altitude sub-orbital platform. From a 400 km orbit, the instrument has a 3dB spatial resolution of 20 (10) km at 220 (670) GHz and a swath of 600 km over 180 degrees of view.The BAPTA (Bearing And Power Transfer Assembly) carries heritage from the SSMIS design, now in its 22nd year of on-orbit operation, but with a much reduced SWaP (Size Weight and Power) footprint, suitable for a small satellite.The main components of the instrument have been fabricated and are undergoing final testing prior to their integration as a single unit. The sub-mm channels have dedicated secondary reflectors which illuminate a shared primary reflector. The receiving units are placed behind the focal point of the optical arrangement, so that all beams equally illuminate the primary reflector and are almost co-located on the ground (within a single 220 GHz footprint). Primary and secondary beam patterns have been measured and verified to match the as-designed expectations. A Zytex (TM) window is deployed to protect the secondary reflectors and the feed horns from debris and other contaminants, and to reduce the heat load from the active (hot) IR calibration unit. The insertion loss of Zytex has been measured and is accounted in the calibration equation of the sub-mm channels.The radiometric performance of the sub-mm receivers has been characterized in the lab and under operational conditions of temperature and pressure.This paper discusses the design constraints on the sub-mm components, details of the scientific goals and their flowdown, and describes the characterization of the polarimeters. Options to optimize the layout and distribution of the masses within the assembly, with the goal of making the instrument even more compact and fully-compatible with cubesat-class satellites will be presented.

De Amici, G.↗

Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary Report of PESP2008 - The Workshop on Polarized Electron Sources and Polarimeters

The Workshop on Polarized Electron Sources and Polarimeters (PESP2008) was hosted by Jefferson Lab October 1-3, 2008, in association with SPIN2008, continuing a tradition since 1983. The workshop was well attended with 84 registrants, 38 oral presentations and 17 posters. The usual topics were covered: DC and RF photoguns, high voltage issues, photocathodes, drive lasers, vacuum and polarimetry. Detailed accounts of each contribution (oral and poster) appear within these Proceedings. This submission summarizes some of the highlights of the workshop.

43 PARTICLE ACCELERATORS↗

Absolute polarimeter for the proton-beam energy of 200 MeV

A polarimeter is upgraded and tested in a 200-MeV polarized-proton beam at the accelerator-collider facility of the Brookhaven National Laboratory. The polarimeter is based on the elastic polarizedproton scattering on a carbon target at an angle of 16.2°, in which case the analyzing power is close to unity and was measured to a very high degree of precision. It is shown that, in the energy range of 190–205 MeV, the absolute polarization can be measured to a precision better than ±0.5%.

43 PARTICLE ACCELERATORS↗

Double Image Polarimeter—Ultra Fast: Simultaneous Three-color (BVR) Polarimeter with Electron-multiplying Charge-coupled Devices

We describe a new instrument capable of high-precision (10{sup −5}) polarimetric observations simultaneously in three passbands (BVR). The instrument utilizes electron-multiplying charge-coupled device (EM CCD) cameras for high efficiency and fast image readout. The key features of the Double Image Polarimeter—Ultra Fast (DIPol-UF) are: (i) the optical design with high throughput and inherent stability; (ii) great versatility, which makes the instrument optimally suitable for observations of bright and faint targets; and (iii) a control system, which allows the use of the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observations of bright nearby stars and of fainter sources such as X-ray binaries in their quiescent states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Spin-Light Polarimeter for Multi-GeV Longitudinally Polarized Electron Beams

The physics program at the upgraded Jefferson Lab (JLab) and the physics program envisioned for the proposed electron-ion collider (EIC) include large efforts to search for interactions beyond the Standard Model (SM) using parity violation in electroweak interactions. These experiments need precision electron polarimetry with an uncertainty of <; 0.5 %. The spin dependent Synchrotron radiation, called "spin-light," can be used to monitor the electron beam polarization. Here, we develop a conceptual design for a "spin-light" polarimeter that can be used at a high intensity, multi-GeV electron accelerator. We have also built a Geant4 based simulation for a prototype device and report some of the results from these simulations

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Stellar X-ray Polarimeter - A focal plane polarimeter for the Spectrum X-Gamma mission

This paper describes an X-ray polarimeter that will be flown on the Spectrum X-Gamma mission. The instrument exploits three distinct physical processes to measure polarization: Bragg reflection from a graphite crystal, Thomson scattering from a metallic lithium target, and photoemission from a cesium iodide photocathode. These three methods allow polarization measurements over an energy band from 0.3 to 12 keV. The polarimeter will make possible sensitive measurements of several hundred known X-ray sources. X-ray polarization measurements will make it possible to constrain the geometry of gas flow in X-ray binaries, identify nonthermal emission in supernova remnants, test current models for X-ray emission in radio pulsars, determine the radiation mechanisms in active galactic nuclei, and search for inertial frame dragging (Lense-Thirring effect) around the putative black hole in Cygnus X-1.

Kaaret, P.↗

A slow neutron polarimeter for the measurement of parity-odd neutron rotary power

We present the design, description, calibration procedure, and an analysis of systematic effects for an apparatus designed to measure the rotation of the plane of polarization of a transversely polarized slow neutron beam as it passes through unpolarized matter. This device is the neutron optical equivalent of a crossed polarizer/analyzer pair familiar from light optics. This apparatus has been used to search for parity violation in the interaction of polarized slow neutrons in matter. Given the brightness of existing slow neutron sources, this apparatus is capable of measuring a neutron rotary power of dϕ/dz = 1 × 10{sup −7} rad/m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact spherical neutron polarimeter using high-T{sub c} YBCO films

We describe a simple, compact device for spherical neutron polarimetry measurements at small neutron scattering angles. The device consists of a sample chamber with very low (<0.01 G) magnetic field flanked by regions within which the neutron polarization can be manipulated in a controlled manner. This allows any selected initial and final polarization direction of the neutrons to be obtained. We have constructed a prototype device using high-T{sub c} superconducting films and mu-metal to isolate regions with different magnetic fields and tested device performance in transmission geometry. Finite-element methods were used to simulate the device’s field profile and these have been verified by experiment using a small solenoid as a test sample. Measurements are reported using both monochromatic and polychromatic neutron sources. The results show that the device is capable of extracting sample information and distinguishing small angular variations of the sample magnetic field. As a more realistic test, we present results on the characterization of a 10 μm thick Permalloy film in zero magnetic field, as well as its response to an external magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

280 GHz Focal Plane Unit Design and Characterization for the Spider-2 Suborbital Polarimeter

We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne Spider instrument. These FPUs are vital to Spider’s primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a $16 \times 16$ grid of corrugated silicon feedhorns coupled to an array of aluminum–manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1530 polarization-sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper, we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be $\sim $ 3 pW at 300 mK with a less than 6% variation across each array at $1\sigma $ . These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the Spider-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Polarimeter + Lidar Derived Aerosol Particle Number Concentration

In this study, we propose a simple method to derive vertically resolved aerosol particle number concentration (Na) using combined polarimetric and lidar remote sensing observations. This method relies on accurate polarimeter retrievals of the fine-mode column-averaged aerosol particle extinction cross section and accurate lidar measurements of vertically resolved aerosol particle extinction coefficient such as those provided by multiwavelength high spectral resolution lidar. We compare the resulting lidar + polarimeter vertically resolved Na product to in situ Na data collected by airborne instruments during the NASA aerosol cloud meteorology interactions over the western Atlantic experiment (ACTIVATE). Based on all 35 joint ACTIVATE flights in 2020, we find a total of 32 collocated in situ and remote sensing profiles that occur on 11 separate days, which contain a total of 322 cloud-free vertically resolved altitude bins of 150 m resolution. We demonstrate that the lidar + polarimeter Na agrees to within 106% for 90% of the 322 vertically resolved points. We also demonstrate similar agreement to within 121% for the polarimeter-derived column-averaged Na. We find that the range-normalized mean absolute deviation (NMAD) for the polarimeter-derived column-averaged Na is 21%, and the NMAD for the lidar + polarimeter-derived vertically resolved Na is 16%. Taken together, these findings suggest that the error in the polarimeter-only column-averaged Na and the lidar + polarimeter vertically resolved Na are of similar magnitude and represent a significant improvement upon current remote sensing estimates of Na.

Aerosol number concentration↗