Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Note: A large open ratio, time, and position sensitive detector for time of flight measurements in UHV

We report on the construction of an UHV compatible 40 mm active diameter detector based on micro channel plates and assembled directly on the feed-throughs of a DN63CF flange. It is based on the charge division technique and uses a standard 2 inch Si wafer as a collector. The front end electronic is placed directly on the air side of the flange allowing excellent immunity to noise and a very good timing signal with reduced ringing. The important aberrations are corrected empirically providing an absolute positioning accuracy of 500 μm while a 150 μm resolution is measured in the center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A zero dead-time multi-particle time and position sensitive detector based on correlation between brightness and amplitude

A new multi-particle time and position sensitive detector using only a set of microchannel plates, a waveform digitizer, a phosphor screen, and a CMOS camera is described. The assignment of the timing information, as taken from the microchannel plates by fast digitizing, to the positions, as recorded by the camera, is based on the COrrelation between the BRightness of the phosphor screen spots, defined as their integrated intensity and the Amplitude of the electrical signals (COBRA). Tests performed by observing the dissociation of HeH, the fragmentation of H{sub 3} into two or three fragments, and the photo-double-ionization of Xenon atoms are presented, which illustrate the performances of the COBRA detection scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Special Nuclear Material Characterization Using Digital 3-D Position Sensitive CdZnTe Detectors and High Purity Germanium Spectrometers

Special nuclear material (SNM) monitoring often requires high resolution gamma-ray spectroscopy for material characterization. Portable systems and rapid deployment are also highly valued for some applications. Deployable gamma-ray imaging spectrometers using pixelated CdZnTe semiconductor detectors have become commercially available within the past three years to meet these requirements. CdZnTe systems have demonstrated room-temperature energy resolutions below 0.5% FWHM at 662 keV using single pixel events and below 0.7% FWHM at 662 keV using all events. The systems are able to go from storage to measurement in less than two minutes. Special nuclear materials were measured at the Y-12 National Security Complex and at the Device Assembly Facility at the Nevada National Security Site. The use of a CdZnTe system to measure uranium enrichment was demonstrated and uranium spectral features were compared to a commercially available high purity germanium (HPGe) spectrometer. The use of passive gamma ray spectroscopy techniques to estimate plutonium grade using CdZnTe detectors was demonstrated for the first time.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

System and method for dose verification and gamma ray imaging in ion beam therapy

This disclosure provides systems, methods, and apparatus related to ion beam therapy. In one aspect, a system includes a position sensitive detector and a collimator. The position sensitive detector configured to detect gamma rays generated by an ion beam interacting with a target. The collimator is positioned between the target and the position sensitive detector. The collimator includes a plurality of knife-edge slits, with a first knife-edge slit intersecting with a second knife-edge slit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using 3D position sensitivity to reveal response non-uniformities in CdZnTe, TlBr, and CsPbBr 3 detectors

Position sensitivity enables the correction of response non-uniformities in room-temperature semiconductor detectors caused by crystal defects and other factors. It can also be used to pinpoint the exact location of crystal defects responsible for the response variations. This work describes a technique for revealing and visualizing the detector regions affecting the charge collection efficiency in CdZnTe (CZT), TlBr, and CsPbBr 3 detectors configured as position-sensitive virtual Frisch-grid (VFG) devices. The technique correlates the photopeak events in energy spectra with their spatial distributions inside the detectors using the position information. By selecting the events from narrow energy intervals within a photopeak, we can visualize the detector volumes with particular charge collection efficiencies, which, in turn, correlate with the locations of electrode and crystal defects. Here, we demonstrate this technique in several examples. Columnar structures in the volume plots (position distribution maps) are consistent with signal losses near or at the anode in selected samples of CZT and TlBr. Structures exhibiting a distinct depth dependence are consistent with grain boundaries or other crystal defects.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Position sensitive alpha detector for an associated particle imaging system

Associated Particle Imaging (API) is a nuclear technique that provides for the nondestructive determination of 3D isotopic distributions. The method is based on the detection of the alpha particles associated with the neutron emitted in the deuterium-tritium (DT) fusion reaction, which provides information regarding the direction and time of the emitted 14 MeV neutron. Inelastic neutron scattering leads to characteristic gamma-ray emission from certain isotopes, for example 12 C, that can be correlated with the neutron interaction location. An API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector is under development for the nondestructive quantification of carbon distribution in soils. This paper describes the design of the alpha detector, detector response simulations, and first experimental results. The alpha detector consists of a Yttrium Aluminum Perovskite (YAP) scintillator mounted on the inside of a neutron generator tube. The scintillation light propagates through a sapphire window to a position-sensitive photomultiplier tube mounted on the outside. The 16x16 output signals are connected through a resistive network for a 4-corner readout. The four readout channels are amplified, filtered, and then digitized for the calculation of the alpha position. First test findings demonstrate that an excellent alpha position resolution, better than the 1 mm FWHM required by the application, can be achieved with this detector design.

47 OTHER INSTRUMENTATION↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

: Small Animal SPECT/CT System Based on Position-Sensitive Semiconductor Detectors

We developed a SPECT/CT system for small-animal imaging utilizing a mechanically cooled, position-sensitive germanium detector for the SPECT camera. The detector offers better energy resolution than any other detector previously used for SPECT and demonstrates dual-isotope imaging capabilities superior to that of current commercial small-animal SPECT systems. We also explored a unique SPECT camera configuration consisting of a silicon detector and germanium detector stacked one behind the other and located behind a multi-pinhole collimator. This scheme is intended for imaging iodine-123 radiotracer distributions, with the ~30 keV x-ray emissions detected in the silicon detector and the 159 keV gamma-ray emissions passing through the silicon and detected in the germanium detector. Image reconstruction methods for combining this multi-energy, multi-magnification data were developed and it was shown that inclusion of the silicon data reduced artifacts in comparison to the germanium data alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Applications of principal component analysis for energy reconstruction in position-sensitive semiconductor detectors

We report semiconductor detectors with pixelated anodes offer a desirable combination of position sensitivity and energy resolution that are suitable for numerous applications in gamma-ray detection and imaging. Pixelization of electrodes also entails a non-uniform amplitude response as a function of gamma-ray interaction position. Energy calibrations as a function of interaction position improve energy resolution, but systematic errors in the energy reconstruction process persist and limit energy resolution at fixed electronic noise. Digitization of signals induced on collecting and adjacent electrodes offers rich information about gamma-ray interactions and their charge drift and collection as a function of time. Despite the abundance of signals for each interaction, human intuition and rule-based approaches fail to utilize the entire set of observed signals to mitigate the sources of systematic error. In order to maximize the utility of digitized signals and improve energy resolution, principal component analysis is applied towards digitized signals observed in semiconductor detectors with pixelated anodes. Principal components identified in the process form the basis for position-specific energy corrections. By leveraging this additional information encoded within digitized signals, energy resolution improves by factors between 10 and 15% with respect to full-width at half and tenth maximum values. The feature that accounts for the maximum amount of explained variance between interactions in any given pixel correlates strongly with the depth of interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent development of the Multi-Grid detector for large area neutron scattering instruments

Most of the Neutron Scattering facilities are committed in a continuous program of modernization of their instruments, requiring large area and high performance thermal neutron detectors. Beside scintillators detectors, {sup 3}He detectors, like linear PSDs (Position Sensitive Detectors) and MWPCs (Multi-Wires Proportional Chambers), are the most current techniques nowadays. Time Of Flight instruments are using {sup 3}He PSDs mounted side by side to cover tens of m{sup 2}. As a result of the so-called '{sup 3}He shortage crisis{sup ,} the volume of 3He which is needed to build one of these instruments is not accessible anymore. The development of alternative techniques requiring no 3He, has been given high priority to secure the future of neutron scattering instrumentation. This is particularly important in the context where the future ESS (European Spallation Source) will start its operation in 2019-2020. Improved scintillators represent one of the alternative techniques. Another one is the Multi-Grid introduced at the ILL in 2009. A Multi-Grid detector is composed of several independent modules of typically 0.8 m x 3 m sensitive area, mounted side by side in air or in a vacuum TOF chamber. One module is composed of segmented boron-lined proportional counters mounted in a gas vessel; the counters, of square section, are assembled with Aluminium grids electrically insulated and stacked together. This design provides two advantages: First, magnetron sputtering techniques can be used to coat B{sub 4}C films on planar substrates, and second, the neutron position along the anode wires can be measured by reading out individually the grid signals with fast shaping amplifiers followed by comparators. Unlike charge division localisation in linear PSDs, the individual readout of the grids allows operating the Multi-Grid at a low amplification gain, hence this detector is tolerant to mechanical defects and its production accessible to laboratories equipped with standard equipment. Prototypes of different configurations and sizes have been developed and tested. A demonstrator, with a sensitive area of 0.8 m x 3 m, has been studied during the CRISP European project; it contains 1024 grids, and a surface of isotopically enriched B{sub 4}C film close to 80 m{sup 2}. Its size represented a challenge in terms of fabrication and mounting of the detection elements. Another challenge was to make the gas chamber mechanically compatible with operation in a vacuum TOF chamber. Optimal working condition of this detector was achieved by flushing Ar-CO{sub 2} at a pressure of 50 mbar, and by applying 400 Volts on the anodes. This unusual gas pressure allows to greatly simplifying the mechanics of the gas vessel in vacuum. The detection efficiency has been measured with high precision for different film thicknesses. 52% has been measured at 2.5 Angstrom, in good agreement with the MC simulation. A high position resolution has been achieved by centre of gravity measurement of the TOT (Time-Over-Threshold) signals between neighbouring grids. These results, as well as other detection parameters, including gamma sensitivity and spatial uniformity, will be presented. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗