A position-sensitive X-ray detector for the HEAO-A satellite.

A position-sensitive, low-energy proportional counter system is described which will be used on the High-Energy Astronomical Observatory, Mission A, spacecraft. The associated system incorporates the capability to employ pulse-shape discrimination for background rejection and interpolation circuitry to locate the centroid of an X-ray event with an accuracy of approximately one eighth the cathode-wire spacing.

Held, D.↗

Low-distortion resistive anodes for two-dimensional position-sensitive MCP systems

Microchannel plates (MCPs) are frequently used with resistive anodes to detect charged particles or photons and yield analog signals from which event positions can be decoded. The paper discusses a four-corner concave circular arc terminated resistive anode that permits theoretically distortionless encoding of Cartesian event positions into pulse charge ratios. The theory of the circular arc terminated anode is discussed along with anode design and performance. Electron beam images obtained by using such an anode are presented to confirm the usefulness of the approach.

Lampton, M.↗

New position-sensitive hard X-ray spectrometer

The design and features of a new prototype Lixiscope (Low intensity X-ray imaging scope) is described. It is shown that in addition to good spatial and temporal resolution in the 20 keV to 200 keV region, it is capable of single-photon counting, imaging as well as good energy resolution. It is concluded that the device is well suited for future low-flux applications in astronomy, medicine, and industry.

Yin, L. I.↗

A focussing iron line crystal spectrometer for Spacelab

A crystal spectrometer system is described which employs conical focusing of 12 curved LiF crystal panels to minimize the detector size and reduce the background counting rate. The wavelength range from 1.70 to 1.98 A is covered, including the resonance lines of Fe XXV and Fe XXVI as well as the Fe I K-alpha line and absorption edge. Operation of the spectrometer is discussed, noting that diffracted X-rays are registered in one-dimensional position-sensitive detectors and that the arrival position of a photon in a detector is related to its wavelength due to the fixed curvature of the crystal panels in the dispersion plane. Some characteristics of the multianode position-sensitive detectors are reviewed along with the crystal arrangement and mounting. The instrument sensitivity is evaluated in relation to the strengths of 6.7-keV emission features detected by the Ariel 5 and OSO 8 proportional-counter spectrometers.

Catura, R. C.↗

Solar X-ray spectroscopy with a Bent Crystal Spectrometer /BCS/

A high-resolution Bent Crystal Spectrometer (BCS) which provides simultaneous and continuous time coverage of a range of wavelengths is described; its application to spectral studies of solar X-ray emission is discussed. Design of the BCS and its accompanying position-sensitive detector is considered. Calibrations of the crystal curvature, the angle between a crystal reference plane and the collimator axis, and the position response of the position-sensitive proportional counter in determining absolute wavelengths are also mentioned. An active solar region spectrum obtained during an airborne BCS test is compared to wavelength data derived from theory or previous experiments, and excellent agreement is found. Specifications for a BCS system to be used in the Solar Maximum Mission satellite of 1979 are given.

Rapley, C. G.↗

Solar aspect determination system

Sensor containing commercially available solid-state position-sensitive light detector provides complete space-vehicle sun or moon vector information.

Farthing, W. H.↗

Two high resolution velocity vector analyzers for cosmic dust particles

Methods are described to measure velocities and angles of incidence of charged cosmic dust particles with precisions of about 1 percent and 1 degree, respectively. Both methods employ four one-dimensional position-sensitive detectors in series. The first method utilizes a charge-dividing technique while the second utilizes a time-of-flight technique for determining the position of a particle inside the instrument. The velocity vectors are measured although mechanical interaction between the particle and the instrument is completely avoided. Applications to cosmic dust composition and collection experiments are discussed. The range of radii of measurable particles is from about 0.01 to 100 microns at velocities from 1 to 80 km/s.

Aver, S.↗

Separation of surface and bulk minority-carrier lifetimes in silicon

A photoexcitation technique is suggested which is direct and convenient, requiring little special equipment. No change in the dimensions of the crystal sample is necessary. Although related to the technique of interposing a filter between the light source and the sample, it differs in that the filter is part of the crystal itself. Basically, one of the electrodes is split into two electrodes, one collecting charge from carriers excited in the bulk. This phenomenon in which the carriers follow very closely the electric field lines has been used in position-sensitive semiconductor radiation detectors (Norbeck and Carlson, 1963) but has not been applied to lifetime measurements. In a sense, the split electrode creates a sample without a surface.

Carroll, K. A.↗

Two high resolution velocity vector analyzers for cosmic dust particles

Two new methods are described to measure velocities and angles of incidence of charged cosmic dust particles with precisions of about 1% and 1 deg, respectively. Both methods employ four one-dimensional position-sensitive detectors in series. The first method utilizes a charge-dividing technique while the second utilizes a time-of-flight technique for determining the position of a particle inside the instrument. The velocity vectors are measured although mechanical interaction between the particle and the instrument is completely avoided. Applications to cosmic dust composition and collection experiments are discussed. The range of radii of measurable particles is from about 0.01 to 100 microns at velocities from 1 to 80 km/sec.

Auer, S.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

Evaluation of clad scintillating light pipes

Arrays of fibers made of scintillating material were used as position-sensitive detectors or hodoscopes for beam-finding at ion accelerators. Experiments were made with alpha's from an Am241 source incident upon one end of the fiber, the other end being viewed with a photomultiplier tube. The scintillation light was not detected in any of the fibers tested beyond about 5 cm. The effective useful lengths for detection of relativistic heavy ions were given.

Source record↗

Quadrant anode image sensor

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.

Lampton, M.↗

The Photicon

The Photicon is a novel imaging optical detector utilizing a conventional semitransparent photocathode, imaging electrostatic optics, microchannel plates, and a crossed-wire-grid position-sensitive charge detector. Its sensitivity to single optical photons over a two-dimensional area, high-resolution imaging, and timing capability render it useful for recording scintillations from X-ray image converters in X-ray astronomy. A digital word indicating the position of a single photon event is produced; the image can be stored in an array or serially. Spatial resolution to 20 microns in a 25 mm diam active area detector is reported, and modifications to achieve a spectral range of 120-730 nm are mentioned.

Kellogg, E.↗

The curved crystal X-ray spectrometer for the HEAO-B satellite

The Focal Plane Crystal Spectrometer on HEAO-B is a moderate to high resolution, curved-crystal, Bragg spectrometer which operates behind a grazing incidence X-ray telescope. It is designed to allow detailed spectral studies of both point and extended celestial X-ray sources in the energy range 0.2-3.3 keV, with resolutions of 50 to 1000. The analyzing elements are six torroidal diffractors, and the detectors are position-sensitive, flow, proportional counters. HEAO-B is scheduled for launch in June, 1978.

Canizares, C. R.↗

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.↗

The nuclear and ionic charge distribution particle experiments on the ISEE-1 and ISEE-C spacecraft

The ISEE-1 and ISEE-C instruments are designed to measure the elemental abundances, charge state composition, energy spectra, and angular distributions of energetic ions in the energy range 2 keV/charge to 80 MeV/nucleon and electrons between 75 and 1300 keV. The instrument consists of three sensor systems: (1) ULECA which is an electrostatic deflection system with rectangular solid-state detectors for the 3-560 keV/charge range; (2) ULEWATT which is a double dE/dX vs E thin-window flowthrough proportional counter/solid-state detector telescope for the 0.2-80 MeV/nucleon (Fe) range; and (3) ULEZEQ which is a combination of an electrostatic deflection analyzer and a thin-window dE/dX vs E system with thin-window proportional counter and position-sensitive solid-state detector. The applications of the instruments to solar and interplanetary phenomena and to magnetospheric acceleration and trapped particles are discussed.

Hovestadt, D.↗

Imaging proportional counter for X-ray astronomy

A position-sensitive proportional counter capable of imaging X-rays (0.1-3 keV) over a 10 cm x 10 cm aperture has been constructed. Positioning is obtained by sensing the signals induced by an X-ray event on the two orthogonal sets of cathode wires. Each cathode is divided into a series of cathode strips, each 0.5 cm wide. An X-ray event induces signals on several adjacent strips. Signals from each cathode strip are amplified separately and then added in an equally weighted and an unequally weighted summing amplifier. The position in each direction is obtained by dividing the output of the unequally weighted summer by that of the equally weighted summer. At 0.94 keV, the accuracy of the position sensing is 190 microns. At the same energy, the energy resolution is approximately 65% (FWHM). The proportional counter system is currently being incorporated into a sounding rocket payload having metal mirror optics, which is being constructed by the X-ray astronomy group at the California Institute of Technology.

Long, K. S.↗

Direct detection of XUV radiation with a CCD

A thinned CCD illuminated from the back has been used for direct imaging in the 584 and 304 A resonance lines of helium and in the 736 A line of neon. During operation, the CCD was cooled to minus 10 C and output was displayed on a CRT screen or in numerical printout. The results demonstrate that the back-illuminated CCD can be used as a position-sensitive flux detector with good imaging properties over a wide range of photon energies, including the extreme ultraviolet.

Burstein, P.↗