Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positron Emission Particle Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Tracking Synthetic Particle Paths Generated in GATE with Multi-Positron Emission Particle Tracking (MPEPT)

Multi-Positron Emission Particle Tracking (MPEPT) is able to reconstruct the position of point-sources in a PET scanner to a high degree of accuracy. Experimental and simulated trajectories of activated point-sources are compared herein to validate the GATE model of our PET scanner, and test MPEPT performance. The trajectory followed by one point-source of activity 370000 Bq is simulated in GATE, and experimentally measured for velocities 0.18, 0.22. and 0.45 cm/s moving along the major axis of the detector bore. The average difference between the prescribed and predicted point-source positions is found to be approximately 0.3 mm. However, the number of Lines of Response (LOR) reported by GATE for the 370000 Bq source is larger than the number of LOR measured in the experiments. Additional testing of the accuracy of MPEPT is provided by the simulation of 20 point-sources of 20 Bq each placed around the surface of a sphere of radius 40 mm and moving radially inward to a radius of 20 mm at a constant velocity of 1 E-6 m/s. Point-source trajectories for the GATE simulation are compared to trajectories reconstructed from the GATE generated LOR using MPEPT. The average difference between prescribed and predicted point-source position is found to be approximately 0.72 mm. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Noninvasive interrogation of local flow phenomena in twisted tape swirled flow via positron emission particle tracking ($\mathrm{PEPT}$)

Twisted tape inserts are often used to enhance the performance of heat exchangers. Previous simulations suggest the existence of secondary vortices and modified axial velocity profiles in these swirled flows, with only limited experimental evidence for these predictions. Here in this work, positron emission particle tracking (PEPT) is used to interrogate turbulent twisted tape swirl flow in a pipe. PEPT is a noninvasive, radiotracer based flow measurement technique that does not require optical access, making it suitable for measurements in a number of engineering flow systems. The existence of the modified velocity profile and secondary flows is confirmed using PEPT, and flow is seen to still be developing 20 diameters downstream of the twisted channel entrance. Secondary vortices are further confirmed by the presence of increased vorticity in these regions, and turbulent fluctuations are seen to increase in magnitude near these flow structures. These results are in line with predictions and point to possible regions of reduced heat transfer and hot spots in twisted tape based heat exchangers. Suggestions are made for future experiments to investigate heated flows, utilizing the ability of PEPT to image flows in opaque systems for validating simulation of flows in engineering equipment, such as nuclear heat transport equipment.

42 ENGINEERING↗

Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements

Increasingly, fully 3D experimental measurements of flow in complex engineering geometries are required to validate computational fluid dynamics models that support and inform reactor design and licensing. One barrier to such measurements is the complexity of typical reactor components and subsequent lack of optical access in these systems. To overcome this, the deployment of coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) is explored for flow measurement in reactor thermal hydraulic components and model (scaled) systems. Through this methodology, fully 3D flow information (via PEPT) and detailed internal geometry (via CT) are captured in opaque systems such as pipes, rod bundles, packed beds, etc. The reconstructed flow field and geometry can then be overlain to reveal detailed flow features around internal structures within a given test section. This is enabled through the use of a combined preclinical PET/CT scanner with overlapping PET and CT fields of view. Such measurements are useful for characterizing flow inside such intricate nuclear thermal hydraulic components as core geometries and heat exchangers, among others, and providing valuable 3D validation data for CFD models. In this work, basic tests of this 3D flow/geometry mapping are presented, and the implications of such measurements are discussed. Further, preliminary measurements are made with both point sources and flow in a simple pipe flow geometry to evaluate the capabilities of this technique. PEPT and CT features are coregistered with up to 0.1 mm precision, and pipe flow mean velocity and Reynolds stresses are reconstructed with similar accuracy to previous PEPT demonstrations. The utility of PEPT/CT is shown herein, and suggestions for future measurements are made.

3D flow measurement↗

Positron emission tracking of individual particles in particle-laden rimming flow

The motion of a single tracer particle in particle-laden rimming flows is investigated experimentally by means of Positron Emission Particle Tracking (PEPT). Semi-dilute suspensions, with a volume fraction of 8% of heavy particles are considered. The trajectory of the tracer particle is monitored for several thousand cylinder revolutions and related to the optically recorded drift of the large-scale granular segregation bands developing in the cylinder. Results of the data analysis provide first insights into the relation between behaviour of individual particles and the spatiotemporal dynamics displayed by the macroscopic particle-segregation patterns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Radiotracer Assessment of Pulsatile Flow

Positron Emission Particle Tracking (PEPT) is a Lagrangian measurement technique used to examine flow behavior. In PEPT, tracer particles are labeled with a positron-emitting radionuclide. The emitted positron annihilates with a nearby electron, producing two back-to-back gamma rays of 511 keV. These gamma rays are detected using a Positron Emission Tomography (PET) scanner. The PET scanner monitors the detection sites and corresponding time in time steps on the order of milliseconds. The detection sites of the two gamma rays are connected via lines of response (LORs), and with multiple LORs a particle location is determined. Many methods have been explored in the past to track tracer particles in the field of view (FOV) of the scanner. The initial method for single particle PEPT was established by Parker et al. This method was refined to track multiple particles by Yang et al. Another method was developed by Bickell, et al based on the 'line density' of LORs in the scanner's FOV. This method was modified by Wiggins, et al to locate and track multiple particles in the FOV without a priori information about the particles. Pulsatile flow is seen in human blood flow and hydraulic and mechanical systems. The pressure gradient of the flow has been studied in an elastic tube with varying viscosity and stiffness by Anssari-Benam et al. Velocity and Reynold stresses have been examined in a rigid tube by Adamec et al. In this research, a new pulsatile flow system is constructed to analyze 3D velocity fields in Lagrangian specifications with capability of conversion to Eulerian specification. The absolute pressure across the test section is also examined. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Numerical and experimental comparison of tracer particle and averaging techniques for particle velocities in a fluidized bed

Particle tracking methods using emitted radiation show potential for following motion in opaque systems such as granular materials. Leading examples are Positron Emission Particle Tracking (PEPT) and Radioactive Particle Tracking (RPT). The application of such techniques sometimes requires the use of tracer particles which differ in size, density and/or shape from the particles of interest. This study investigates the extent to which such differences affect the result of the study by using the open source MFIX-DEM software to model particle motion in the travelling fluidized bed experiments. The results are compared with previously reported experimental studies using both PEPT and RPT. Consistent numerical results were obtained for both PEPT and RPT tracer particles. In determining averaged velocities using such techniques, there is a choice to be made between averaging velocities of particles crossing a virtual plane over a period of time (the “face-average” approach) or those passing through a defined volume over time (the “volume-average” approach). The differences between results obtained with these two methods are shown to be significant in this case, for both computation and experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimum value of original events on the PEPT technique

Do Positron emission particle tracking (PEPT) has been used to track the motion of a single radioactively labeled tracer particle within a bed of similar particles. In this paper, the effect of the original event fraction on the results precise in two experiments has been reviewed. Results showed that the algorithm can no longer distinguish some corrupt trajectories, in addition to; further iteration reduces the statistical significance of the sample without improving its quality. Results show that the optimum value of trajectories depends on the type of experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Jitter Clock Receivers for Fast Timing Applications

Precision timing is a key requirement for emerging 4D particle tracking, Positron Emission Tomography (PET), beam and fusion plasma diagnostics, and other systems. Time-to-Digital Converters (TDCs) are commonly used to provide digital estimates of the relative timing between events, but the jitter performance of a TDC can be no better than the performance of the circuits that acquire the pulses and deliver them to the TDC. Several clock receiver and distribution circuits were evaluated, and a differential amplifier with resistive loads driving a pseudo-differential clock distribution network, developed using design guidelines for radiation tolerance and cryogenic compatibility, was fabricated as part of three prototypes: an analog front-end testbed chip for high-precision timing pixel readout, a dedicated TDC evaluation chip, and a Low-Gain Avalanche Detector (LGAD) readout circuit. Based on TDC measurements of the prototypes, we infer that the jitter added by the clock receiver and distribution circuits is less than 2.25 ps-rms. This performance meets the requirements of many future precision timing systems. The clock receiver and on-chip pseudo-differential driver were fabricated in commercial 28-nm CMOS technology and occupy 2288 µm 2 .

47 OTHER INSTRUMENTATION↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

MR-based motion correction for PET imaging using wired active MR microcoils in simultaneous PET-MR: Phantom study

Purpose: Artifacts caused by head motion present a major challenge in brain positron emission tomography (PET) imaging. The authors investigated the feasibility of using wired active MR microcoils to track head motion and incorporate the measured rigid motion fields into iterative PET reconstruction. Methods: Several wired active MR microcoils and a dedicated MR coil-tracking sequence were developed. The microcoils were attached to the outer surface of an anthropomorphic{sup 18}F-filled Hoffman phantom to mimic a brain PET scan. Complex rotation/translation motion of the phantom was induced by a balloon, which was connected to a ventilator. PET list-mode and MR tracking data were acquired simultaneously on a PET-MR scanner. The acquired dynamic PET data were reconstructed iteratively with and without motion correction. Additionally, static phantom data were acquired and used as the gold standard. Results: Motion artifacts in PET images were effectively removed by wired active MR microcoil based motion correction. Motion correction yielded an activity concentration bias ranging from −0.6% to 3.4% as compared to a bias ranging from −25.0% to 16.6% if no motion correction was applied. The contrast recovery values were improved by 37%–156% with motion correction as compared to no motion correction. The image correlation (mean ± standard deviation) between the motion corrected (uncorrected) images of 20 independent noise realizations and static reference was R{sup 2} = 0.978 ± 0.007 (0.588 ± 0.010, respectively). Conclusions: Wired active MR microcoil based motion correction significantly improves brain PET quantitative accuracy and image contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of the Mu2e sensitivity to the $\mu^-\rightarrow e^+$ conversion process

The Mu2e experiment at Fermilab (Batavia, IL) will search for the coherent neutrinoless conversion of a muon into an electron in the electric field of an aluminum atom. The conversion process results in a monochromatic electron with energy slightly below the muon rest mass ($E_e= 104.97$ MeV). The experiment goal is to improve the previous measurement by four orders of magnitude and reach a single event sensitivity of $3 \times 10^{-17} $ on the conversion rate with respect to the muon capture rate. \\ The experiment will deliver a very intense pulsed negative muon beam to an aluminum target to achieve a total number of $10^{18}$ stopped muons in three years of running. Production and transport of the muons are accomplished with a sophisticated magnetic system comprised of a Production, a Transport and a Detector solenoid, with the last one hosting a Straw-tube Tracker and a Crystal Calorimeter. The entire detector region is surrounded by a Cosmic Ray Veto system. Mu2e is und er construction at the Muon Campus of Fermilab. \\ The INFN italian group is responsible for the design and construction of the crystal calorimeter, which plays a crucial role in the Mu2e measurement, providing particle identification capabilities fundamental for the rejection of the different background sources that can mimic a conversion electron. The calorimeter information allows also to improve the tracking performances it provides a fast standalone trigger for the experiment.\\ After a long R\&D phase, the final drawings see a calorimeter comprised of 1348 pure CsI crystals arranged in two annular disks. Each crystal is readout by two custom UV-extended Silicon Photomultipliers (SiPMs). Performances of the selected components were verified with an electron beam test, carried out in 2017 at the Beam Test Facility (BTF) at the National Laboratories of Frascati, on a large size prototype of 51 crystals and 102 SiPMs, confirming excellent energy ($\sigma_{E}/E = \mathcal{O }(10\%)$) and timing ($\sigma_{T} <500$ ps) resolutions in a! greement with the Mu2e specifications.\\ In the first chapters of this thesis, I describe my involvement in the calorimeter activities, with particular emphasis on the data analysis of the prototype energy response and resolution, that I was personally leading. Moreover, a description of the tuning of the simulation and the careful data-MC comparison is also reported.\\ An auxiliary measurement that can be performed with Mu2e is the search for a Lepton Number Violation (LNV) process where the negatively charged muon converts, without neutrinos, into a positron, $\mu ^{-} +N(A,Z) \rightarrow $ e$^+ +N(A,Z-2)$. At the moment of writing, Neutrinoless Double Beta Decay (0$\nu \beta \beta$) has set the most stringent limit on the LNV processes (T$^{0\nu \beta \beta}_{1/2} > 1.1 \times 10^{26} $ yr at 90$\%$ CL) with the GERDA experiment. In 0$\nu \beta \beta$ a pair of free electrons is created in the transformation from a nucleus $(A, Z)$ into its daughter $(A, Z + 2)$, namely: $(A,Z)\rightarrow (A, Z+2) =2 e^-$. Similar transitions could proceed through the emission of a pair of positrons, double electron capture (EC), or EC and single emission of a positron, with the nucleus changing from $(A, Z)$ to $(A, Z - 2)$. All these variations are equally interesting when discussing of new Physics, since they all manifest a non-conservation of the number of leptons.\\ Moreover, recent studies show that, because of flavor effect, off-diagonal processes, such as the $\mu^- -e^+$ conversion, can have their rate enhanced with respect to processes occurring in the $e-e$ sector.\\ Mu2e will search for $\mu^- + Al(27,13) \rightarrow e^+ +Na(27,11)$, only considering ground state transition, producing a conversion positron with energy $E_{e^+}= 92.32 $ MeV.\\ This thesis is focused on this search. In particular, I developed an algorithm to account for the radiative corrections to be applied to the conversion positrons that resulted in a few percent reduction in s ignal acceptance.\\ One of the most prominent background to ! this sear! ch is the Radiative Muon Capture (RMC) $ \mu+ N(Z,A)\rightarrow \gamma + \nu_{\mu} + N(Z-1,A)$. The produced photon can convert, virtually or in the detector materials (in the following referred as internal or external conversion respectively) in an electron-positron pair, producing positrons with energies approaching the expected conversion energy. Experimental results from previous experiments indicate the RMC endpoint ($\kmax$) to be of $\sim$ 90 MeV. A precise modeling of this background is relevant due to the proximity of the photon spectrum endpoint to the positron conversion energy. The calorimeter group is obviously interested to reconstruct the RMC distribution having also the opportunity to improve the current knowledge of the process. \\ A toy MC has been developed to evaluate the number of $e^+$ from external RMC background in the signal window. Knowing this value and ev...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production of diverse PET probes with limited resources: 24 18 F-labeled compounds prepared with a single radiosynthesizer

Significance Molecular imaging with PET can provide a dynamic, whole-body picture of the rate of biological processes or distribution of biological targets by tracking the distribution of radiolabeled molecules or particles in the body over time. Continual efforts to develop new PET probes are expanding the variety of processes and targets that can be visualized, facilitating basic research, drug development, and patient care. However, access to these probes at all stages of their development is hindered by high costs arising, in large part, from the significant resources that are typically dedicated to production of a single probe. Emerging technologies with increased synthesis flexibility are allowing increased probe diversity with fewer resources and could significantly increase access to new molecular imaging agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗