Search NASA⌕ Search

SEARCH · Search NASA

Results for “Post Combustion Capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Integrated Capture and Conversion of CO 2 to Methanol in a Post‐Combustion Capture Solvent: Heterogeneous Catalysts for Selective CN Bond Cleavage

Abstract An efficient and selective heterogeneous catalyst is identified for the condensed‐phase hydrogenation of captured CO 2 in the presence of an advanced water‐lean post‐combustion capture solvent, ( N ‐(2‐EthoxyEthyl)‐3‐MorpholinoPropan‐1‐Amine), 2‐EEMPA. The catalysts commonly used for gas‐phase CO 2 hydrogenation (e.g., Cu/Zn/Al 2 O 3 ) cause deactivation of amine promoters via N ‐methylation by CO cleavage of formamide intermediates. A heterogeneous catalyst system that suppresses N ‐methylation of amine solvents is identified, demonstrating how Pt, supported by reducible metal oxides CeO 2 or TiO 2 , can be selective for CN cleavage to produce methanol. This is the first known demonstration of integrated low‐temperature thermocatalytic capture and conversion of CO 2 to methanol in an economically viable CO 2 capture solvent. Technoeconomic analyses performed on the state‐of‐technology suggest that methanol can be produced with a minimum selling price of $4.4/gallon ($1,460/metric ton) when using CO 2 captured from a 650 MW natural gas combined cycle plant. Ultimately, a road map of how realistic and achievable improvements to space velocity and methanol selectivity of this integrated process can enable near cost parity to fossil‐derived methanol, with a selling price of ≈$1.4/gal ($470/metric ton), is presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of energy requirements for CO 2 post-combustion capture process through advanced thermal integration

The energy optimization modeling work described here was performed to determine efficiency improvements that could be achieved for existing coal-fired power plants to retrofit a partial CO 2 capture from the post-combustion flue gas for carbon sequestration through thermal integration. The work presented includes optimization of the mono-ethanol amine (MEA)-based post-combustion CO 2 capture to reduce energy requirements that could be achieved at existing power plants by thermal integration of the steam turbine cycle, boiler, CO 2 compression train and post-combustion CO 2 capture process to offset efficiency and capacity losses that would be incurred by retrofit or implementation of post-combustion CO 2 capture. Furthermore, partial CO 2 capture, involving treatment of less than 100% of the flue gas leaving the plant and modular design of the CO 2 scrubbing system, was also investigated. Thermal integration of the steam turbine cycle with boiler and CO 2 compression train improved cycle and plant performance and offset, in part, the negative effects of post-combustion CO 2 capture. The best-analyzed integration options improved gross power output by 5% and net unit efficiency by 1.57%, relative to the conventional MEA process. Operating with 40% CO 2 capture increased gross power output by 11.6–14% (depending on the MEA thermal integration option), relative to the conventional MEA integration and 90% CO 2 capture. The improvement in net unit performance is larger compared to the improvement in turbine cycle performance because of the CO 2 compression work, which is also reduced by partial CO 2 capture.

42 ENGINEERING↗

Engineering-Scale Test of a Water-Lean Solvent for Post-Combustion Capture

EPRI, Pacific Northwest National Laboratory, RTI International, and their project collaborators developed an engineering-scale test of a new water-lean solvent, N-(2-ethoxyethyl)-3-morpholinopropan-1-amine (EEMPA or 2-EEMPA) as a post-combustion CO 2 capture solvent for power plant applications. This test was conducted using the Pilot Solvent Test Unit at the National Carbon Capture Center. The primary objective of this test was to collect long-term data operating EEMPA with both coal- and natural gas-representative flue gases at the approximately 0.5 MW e -equivalent scale (5–10 metric tons CO 2 /day captured). This report details the activities preparing for that test, data collected during the test campaign, and analyses and interpretations of that data.

20 FOSSIL-FUELED POWER PLANTS↗

Modeling and Uncertainty Quantification of CESAR1 Solvent System for Post-Combustion Capture

This presentation is focused on the development of the CESAR1 solvent system model by the CCSI2 team and validation with pilot plant data from Technology Centre Mongstad. It also serves as an update of previous work by incorporating a new thermodynamic model of the system developed by collaborators from Heriot-Watt University through the SCOPE program. Finally, it includes some discussions on future directions of the project including collaboration with SCOPE to add the capability of amine emissions prediction along with some parametric uncertainty quantification work on the submodels.

Morgan, Joshua↗

Computational Analysis of the Effect of Structured Packing Design on Absorption Column Hydrodynamics for Post-Combustion Carbon Capture Applications

Solvent based post-combustion carbon capture technologies have a potential for reducing carbon emissions from fossil-fuel-fired power plants and industrial sources where CO2 emissions are inherently harder to mitigate, such as steel or cement industries. A prominent technology to achieve this is by retrofitting absorption columns to the existing infrastructure. While these systems have been among the less costly alternatives for carbon capture, they still impose a considerable energy penalty to the operation of power plants or industrial facilities. The optimization of CO2 capture rate in solvent-based absorption process is complex as it depends on several factors including CO2 solubility, solvent reaction kinetics and temperature effects on the solubility, reaction rates, surface tension, and thermophysical properties of the solvent and the flue gas. The overall heat and mass transfer also depends on the hydrodynamics, which in turn, is affected by the packing geometry. In the current work, we systematically quantify the effects the design of the structured packing has on the column hydrodynamics, by performing detailed CFD simulations for different geometrical configurations and operating conditions. We then obtain relationships between the key hydrodynamic metrics, such as liquid holdup, interfacial area, wetted area, and pressure drop to the parameters defining the packing geometries and identify new more effective packing designs for the given operating conditions.

Shah, Yash Girish↗

Demo-scale testing of a hybrid membrane-sorbent system for post-combustion CO2 capture

TDA Research is developing a novel hybrid membrane-sorbent system for the post-combustion capture of carbon dioxide (CO 2 ) from supercritical pulverized coal (PC) power generation facilities or large point industrial emitters. Here, the novel design incorporates a 1st-stage continuous membrane separator developed by Membrane Technology and Research, Inc. (MTR) with a dual-bed radial-flow sorbent contactor (designed and developed at TDA). Testing of a pilot unit at 1 MWe scale has been conducted at the site for emerging technologies at the Technology Centre Mongstad (TCM) in Mongstad, Norway using residue fluid catalytic cracker (RFCC) flue gas from Equinor’s Mongstad refinery.

20 FOSSIL-FUELED POWER PLANTS↗

Transformational Sorbent System for Post-Combustion Carbon Capture (Final Report)

As part of this DOE Contract (Transformational Sorbent System for Post-Combustion Carbon Capture, DE-FE0031734),TDA Research Inc. developed a transformational sorbent system for post combustion CO 2 capture process that captures more than 95% of CO 2 emissions from a coal fired power plant, recovering CO 2 at 95% purity with a cost of CO 2 capture significantly lower than with amine-based system (~$30 per tonne (MT) of CO 2 captured). TDA’s transformational sorbent system uses a novel, highly stable, high-capacity metal organic framework (MOF) based CO 2 sorbent in a new vacuum/concentration swing adsorption (VCSA) process that allows us to use high efficiency vacuum pumps with a low auxiliary load. A pulverized coal fired power plant equipped with TDA’s transformational sorbent system for post combustion CO 2 capture is expected to efficiently produce electricity with a low Cost of Electricity (COE) and capture greater than 95% of the CO 2 from the power plant exhaust.

01 COAL, LIGNITE, AND PEAT↗

Molecular-Level Overhaul of y-Aminopropyl Aminosilicone/Triethylene Glycol Post-Combustion CO2-Capture Solvents

Capturing carbon dioxide (CO2) from post-combustion gas streams is an energy-intensive process that is required prior to either converting or sequestering CO2. There are a few commercial offerings of 1st and 2nd generation aqueous amine technologies, however the cost of capturing CO2 with these technologies remains high. To decrease costs of capture, researchers are designing efficient solvent systems with the goal of being drop-in replacements for 1st and 2nd generation infrastructure. One approach has seen the development of water-lean solvents that aim to increase efficiency by reducing the water content in solution. Water-lean solvents such as GE’s GAP/TEG are promising technologies, with potential to halve the parasitic load to a coal-fired power plant, only if the intrinsically high solution viscosities and hydrolysis of the siloxane moieties could be mitigated. We present here, an integrated multidisciplinary approach to overhaul the GAP/TEG solvent system at the molecular level to mitigate hydrolysis while also reducing viscosity. We present molecular-level insights into chemical speciation of CO2-containing ions, showing that co-solvents and diluents have a negligible effect on reducing viscosity and are not needed. This finding allowed for the design of singlecomponent siloxane-free diamine derivatives with site-specific incorporation of selective chemical moieties for direct placement and orientation of hydrogen bonding to reduce viscosity. Ultimately, we present new single-component diamine formulations less susceptible to hydrolysis that exhibit up to a 98% reduction in viscosity compared to the initial GAP/TEG formulation.

Cantu Cantu, David↗

Accelerating computational fluid dynamics simulation of post-combustion carbon capture modeling with MeshGraphNets

Packed columns are commonly used in post-combustion processes to capture CO 2 emissions by providing enhanced contact area between a CO 2 -laden gas and CO 2 -absorbing solvent. To study and optimize solvent-based post-combustion carbon capture systems (CCSs), computational fluid dynamics (CFD) can be used to model the liquid–gas countercurrent flow hydrodynamics in these columns and derive key determinants of CO 2 -capture efficiency. However, the large design space of these systems hinders the application of CFD for design optimization due to its high computational cost. In contrast, data-driven modeling approaches can produce fast surrogates to study large-scale physics problems. We build our surrogates using MeshGraphNets (MGN), a graph neural network framework that efficiently learns and produces mesh-based simulations. We apply MGN to a random packed column modeled with over 160K graph nodes and a design space consisting of three key input parameters: solvent surface tension, inlet velocity, and contact angle. Our models can adapt to a wide range of these parameters and accurately predict the complex interactions within the system at rates over 1700 times faster than CFD, affirming its practicality in downstream design optimization tasks. This underscores the robustness and versatility of MGN in modeling complex fluid dynamics for large-scale CCS analyses.

97 MATHEMATICS AND COMPUTING↗

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

Incorporation of market signals for the optimal design of post combustion carbon capture systems

Recent studies have shown that fossil generators equipped with post-combustion carbon capture (PCC) systems are needed to reduce the cost of deep decarbonization. Such generators need to be flexible and responsive to grid conditions, particularly in a high variable renewable energy (VRE) environment. In this work, we evaluate the net present value (NPV) of retrofitting an existing natural gas combined cycle (NGCC) unit with a flexible PCC system while incorporating market signals from a high VRE grid. We use our industrial partner’s NGCC configuration as representative of existing NGCC units and Svante’s rapid-temperature swing adsorption (TSA) for PCC. Because of its ability to rapidly startup/shutdown and ramp-up/ramp-down, the chosen capture technology is very attractive for load-following operations. For a given set of market signals, we formulate a two-stage stochastic multi-period optimization problem, under the price-taker assumption, to simultaneously optimize the design of the capture system and operation of the entire plant. Rigorous models for the NGCC unit, PCC system, and compression system are developed using commercial process simulators and validated with either plant or vendor data. For computational tractability, we develop surrogate/reduced-order models for use in the optimization problem. The surrogate model for the NGCC plant is constructed by linearizing the rigorous dynamic model at 75% load, while data-driven nonlinear surrogate models for the capture and compression systems are constructed using simulation data from the rigorous models. The optimization problem, formulated as a mixed integer bilinear program, is implemented in the IDAES® integrated platform and solved to global optimality using Gurobi 9.5. Using this formulation, we determine the profitability of retrofitting an existing NGCC unit with the chosen capture system for multiple regions in the U.S. under two scenarios with different carbon prices. Importantly, the results show that the optimal decision strongly depends on the region and on the carbon price, thereby demonstrating the importance of the inclusion of market signals in the design process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Sensors for In-Situ Amine Degradation Monitoring in Post-Combustion Carbon Capture

In order to improve the long-term performance of post-combustion carbon capture technologies, improvements to the detection of solvent degradation or reduction in CO2 capture efficiency are necessary. A pair of sensors were deployed to the National Carbon Capture Center’s (NCCC) to monitor CO2 capture and solvent degradation. The CO2 sensors were located to measure before capture and after capture concentrations of CO2 to measure the capture efficiency of the solvent system. Amine degradation sensors were located at four locations along the main solvent lines corresponding to CO2 loading and temperature: hot rich, cold rich, hot lean, and cold lean. Experimental results from laboratory tests using the sensors are shown, along with prototype designs that were deployed to the field site.

Brister, Matthew↗

Techno-economic assessment of emissions mitigation technologies for post-combustion CO2 capture using AMP/PZ

Minimizing the environmental impacts of amine-based post-combustion carbon capture technologies is essential for meeting environmental permitting regulations and ensuring public acceptance. Experimental test campaigns at the CO₂ capture pilot plant in Niederaussem using CESAR1 demonstrated that integrating available emission abatement technologies can significantly reduce the concentration of amines and degradation products in CO₂-depleted flue gas to below the detection limit of an infrared spectrometer. The study confirmed that proprietary dry bed technology (OEASE Aerozone™) or a second water wash can lower AMP and PZ emissions to below 1 mg/Nm³. However, to achieve very low NH₃ emissions below 2 mg/Nm³, an acid or other chemically active wash downstream of the water wash is required. A configuration with a dry bed or a double water wash results in a carbon capture cost (CCC) of 44 €/tCO₂, and a CO₂ avoided cost (CAC) of 86 €/tCO₂. A configuration with an acid wash increases the CCC to 47 €/tCO₂ and the CAC to 90 €/tCO₂ due to the amine losses in the acid waste and its treatment.

CO2 capture↗

Mitigation Methods for Piperazine Oxidation in Post-Combustion Carbon Capture

Piperazine is a promising second-generation solvent for amine scrubbing in post-combustion CO2 capture. However, the oxidative degradation of PZ can cause environmental problems and economic loss. This work presents the effects of two mitigation methods: carbon treating and N2 sparging, on the PZ oxidation in long-term operations. The species and their respective quantities adsorbed by the activated carbon were tested in a bench-scale device. The carbon was then tested in the High Temperature Oxidation Reactor (HTOR), where the solvent oxidizes at a reasonably fast rate. Pilot plant campaigns were also performed at the UT Austin SRP and the National Carbon Capture Center (NCCC) and the effects were verified. When dissolved Fe is removed by carbon treating or other methods, available soluble Fe in the system dissolves and replaces the dissolved Fe. Therefore, all available Fe and ligands need to be removed for the mitigation to be effective. The sources of soluble Fe include fly ash and the corrosion of stainless steel, and the ligands are degradation products. 8 All PZ degraded solvents have two absorbance peaks at 320 nm and 538 nm. The 320 nm peak is caused by dissolved metals, especially Fe, complexed by degradation products. The 320 nm peak is related to the amine degradation level and can be used as a simple and efficient method to estimate the amine degradation rate. The pilot plant data suggest that NO2 can oxidize PZ significantly, possibly through radical reactions. 0.01 mmol/kg-hr absorption of NO2 increased the PZ oxidation rate from 1.2 mmol/kg-hr to 2.5 mmol/kg-hr.

Yuying, Wu↗

Modeling, Design, and Testing of a Novel Biphasic Solvent-Enabled Absorption System for Post-Combustion Carbon Capture

A novel absorption process enabled by a new class of biphasic solvents for post-combustion carbon capture (BiCAP) is presently being developed at the University of Illinois at Urbana-Champaign. The new biphasic solvents are water-lean solvent blends that develop dual liquid phases with the absorbed CO2 highly enriched in one of the phases. These solvents are superior in CO2 capacity and have high thermal and oxidative stability compared to MEA. The BiCAP technology features a unique process configuration of multi-stage CO2 absorption and liquid–liquid phase separation during CO2 absorption, allowing continual separation and removal of the CO2-enriched liquid phase for maintaining low solvent viscosity and a fast absorption rate. A 40 kWe-scale skid has recently been constructed at the Abbott Power Plant in Champaign, IL, to test the BiCAP solvent in continuous operation with a slipstream of real post-combustion flue gas. Along with improvements in the stripping configuration including cold feed bypass, the process is expected to achieve a minimum reboiler duty of 2,210 kJ/kg CO2 captured at a stripper operating pressure of 6 bar.

20 FOSSIL-FUELED POWER PLANTS↗