Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power conversion system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparative Investigation of System-Level Optimized Power Conversion System Architectures to Reduce LCOE for Large-Scale PV-Plus-Storage Farms

PV-plus-storage (PVS) has become a prevalent configuration for newly commissioned large-scale solar projects. However, the optimal power conversion system (PCS) architecture has not been investigated yet. This paper first validates the limited impact of inverter cost on LCOE and then explores a system-level optimized PCS architecture with extended LCOE reduction to proliferate large-scale dispatchable solar energy. Two state-of-the-art architectures including central inverters (CI), traditional 480/600 V string inverters (SI) are compared with newly proposed medium voltage string inverters (MVSI) and multiport DC transformer (MDCT). With verified layouts and single line diagrams (SLDs) of 20 MW PVS plants, the losses and costs breakdown of different architectures are extracted and the PCS related LCOEs are derived. In this analysis, all electrical bill of materials (EBOS) elements, inverters, battery storage and its associated components, are included, whose losses and costs are obtained from markets, manufacturers, and literature. Besides, the sensitivities of PCS-related LCOEs to Inverter-Loading-Ratio (ILR) are also investigated. Here, the results show that compared with CI and SI with 1.5 kV PV, 4 kV MVSI and 34 kV MDCT present an extended LCOE reduction across all ILR from 1.0 to 3.0, making them economically favorable candidates for PVS farms.

14 SOLAR ENERGY↗

Modular power conversion system with galvanic insulation

A modular power conversion system is provided which includes a plurality of building blocks comprised of transformers and power conversion bridges, and a high frequency AC link that transfers power and provides galvanic isolation between the building blocks. The high frequency link includes an insulating tube separating an AC link conductor and the building blocks. The insulating tube is further provided with conductive or semiconductive layers on its inner and outer surfaces for referencing them to the electric potentials of the adjacent conductors and windings, thereby placing the high electric fields substantially directly across the tube and reducing electric fields and partial discharge or corona in the adjoining space or media. The building blocks may be arranged in multiple stacks for DC or AC interface, preferably with neutral or lower voltage connections at the outer edges of the stacks and higher voltage terminals at the centers of the stack.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Empirical Comparison of Machine Learning Approaches for Black-Box Modeling of Power Conversion System Dynamics

Inverter-based resources are key components in modern power systems, but accurately modeling their complex behavior can be challenging. Standard, generic converter models often oversimplify inverter dynamics, leading to significant errors in predicting performance. In this work, we compare several data-driven machine learning (ML) approaches for inverter modeling, performing experiments on power conversion systems, systematically varying input conditions, and recording the resulting voltages and currents. The ML models were then trained on this measured data to capture the inverter's dynamic response and to predict the inverter's output current. A performance comparison between the four ML models under study is conducted, laying the foundation for future work on hardware implementation for real-time inference.

30 DIRECT ENERGY CONVERSION↗

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design Considerations for Developing 1.2 kV 4H-SiC BiDFET-enabled Power Conversion Systems

Bidirectional switches are essential for cycloconverter and matrix converter applications to facilitate single-stage AC-AC conversion without intermediate energy storage elements. The 1.2 kV 4H-SiC BiDFET was developed as the first monolithic bidirectional SiC power transistor. This paper describes the design considerations taken into account while creating the BiDFET device and developing custom packages for housing the switch in discrete form for low power applications and in module form for high-power applications. The realized switches are characterized for their on-state and switching performance. The versatility of the BiDFET device is demonstrated by operating a single BiDFET H-bridge in voltage-source-inverter and current-source-inverter topologies only by varying the gate bias on the individual BiDFETs and reversing the input-output connections.

Bidirectional, Silicon Carbide, Half-Bridge Module↗

Power Conversion Systems Enabled by SiC BiDFET Device

The BiDirectional Field-Effect Transistor (BiDFET) can enable circuit topologies requiring four quadrant switches, that were earlier designed using discrete combinations of MOSFETs, IGBTs, GaN HEMTs and PiN diodes. The monolithic nature of the BiDFET allows lower device count, smaller switch volume, lower inductance, and simpler packaging, and hence more reliable and commercially viable implementation in power electronics converters. Furthermore, the matrix converter topologies, now feasible using BiDFETs, can eliminate the bulky and unreliable dc link capacitors or inductors required for conventional voltage-source or current-source converters in ac-ac and ac dc applications. The 1.2 kV BiDFET has the potential to disrupt all the applications utilizing 1.2 kV switches, including electric vehicle (EV) drivetrain, bidirectional EV chargers, industrial motor drives, solid-state transformers, datacenter power supplies, elevator drives, dc microgrids, energy storage grid integration, solid-state breakers, etc.

42 ENGINEERING↗

2019 Energy Storage Pricing Survey

Since grid energy storage is still evolving rapidly, it is often difficult to obtain project specific capital costs for various energy storage technologies. This information is necessary to evaluate the profitability of the facility, as well as comparing different energy storage technology options. The goal of this report is to summarize energy storage capital costs that were obtained from industry pricing surveys. The methodology breaks down the cost of an energy storage system into the following component categories: the storage module; the balance of system; the power conversion system; the energy management system; and the engineering, procurement, and construction costs. By evaluating each of the different component costs separately, a synthetic system cost can be developed that provides internal pricing consistency between different project sizes using the same technology, as well as between different technologies that utilize similar components.

25 ENERGY STORAGE↗

2020 Energy Storage Pricing Survey

The annual Energy Storage Pricing Survey (ESPS) series is designed to provide a standardized reference system price for various energy storage technologies across a range of different power and energy ratings. This is an essential first step in comparing systems of the different technologies’ usage costs and total cost of ownership. The final system prices are developed based on data from an extensive set of interviews with representatives across the manufacturing and project development value chain, plus available published data. This information is incorporated into a consistent methodology structure that will allow pricing information to be incorporated at whatever level it was obtained, ranging from component to fully installed system. The ESPS system pricing methodology breaks down the cost of an energy storage system into the following component categories: the storage module; the balance of system; the power conversion system; the energy management system; and the engineering, procurement, and construction costs. By evaluating each of the different component costs separately, a more accurate system cost can be developed that provides internal pricing consistency between different project sizes using the same technology, as well as between different technologies that utilize similar components.

25 ENERGY STORAGE↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MEITNER Resource Team Modeling and Simulation Support to Holos-Quad Reactor Development (Final CRADA Report)

The main objective of this CRADA is to provide Argonne National Laboratory (ANL)’s modeling and simulation capabilities via ARPA-E's MEITNER (Modeling-Enhanced Innovations Trailblazing Nuclear Energy Reinvigoration) Resource Team (RT) arrangement to support the demonstration of the viability of HolosGen’s Holos-Quad reactor design. The Holos-Quad reactor design is an advanced reactor concept that incorporates many new design features, such as the neutron-coupled Subcritical Power Modules (SPMs) in its core design, elimination of balance of plant (BOP) by direct integration of a helium Brayton cycle power conversion system with each SPM, among many other innovative features. The demonstration of the viability of such an innovative reactor design warrants iterations of modeling and simulation and testing. The purpose of this project is to utilize ANL’s modeling and simulation capabilities in nuclear reactor analysis and power conversion system analysis to inform HolosGen and the Design Team (DT) in the design and optimization of the Holos-Quad concept. The major work scopes of this project include: to investigate conceptual designs and materials for radiation shielding to protect personnel and internal components such as turbomachinery; Assess the the helium Brayton cycle power conversion system performance in both nominal and load following conditions; Investigate power conversion components and overall system performance; Identify control strategies to enable load following; Perform simulations of HolosGen’s subscale simulator and using available test data for code validation/benchmark purpose; Perform core thermal-hydraulics, safety analysis, and structural analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Results of the KRUSTY Nuclear System Test

The Kilowatt Reactor Using Stirling TechnologY (KRUSTY) was a prototypic nuclear-powered test of a 5-kW(thermal) Kilopower space reactor. This paper presents results from the KRUSTY nuclear system test, which operated the power system at various temperatures and power levels for 28 consecutive hours. The testing showed that the system operated as expected and that the reactor is highly tolerant of possible failure conditions and transients. The key feature demonstrated was the ability of the reactor to load-follow the demand of the power conversion system. The thermal power of the test ranged from 1.5 to 5.0 kW(thermal), with a fuel temperature up to 880°C. Each 80-W(electric)–rated Stirling converter produced ~90 W(electric) at a component efficiency of ~35% and an overall system efficiency of ~25%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ANL Design Team Analysis: Transportable Modular Reactor by Balance of Plant Elimination

HolosGen LLC is developing “Holos-Quad” a transportable gas-cooled reactor, with integral load following power conversion systems equipping subcritical power modules (SPMs), fully comprised within standard transport containers. The design eliminates the Balance of Plant (BoP) and greatly simplifies the design layout. A closed-loop full Brayton gas thermodynamic cycle converts the fuel cartridges thermal energy into electricity. This ARPA-E project utilizes advanced reactor modeling tools and manufacturing-testing of a scaled SPM equipped with a surrogate fuel cartridge to eliminate the most significant technology gaps to accelerate commercialization. The Argonne Design Team contributes to the research by demonstrating feasibility of various aspects of the Holos-Quad design by performing high-fidelity neutronic modeling, and investigating various reactivity control systems. This work consists of two main tasks: evaluation of HolosGen’s design features and alternative options study for reactivity control.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of Heat Pipe Failures in Microreactors

Microreactors provide new opportunities for nuclear reactor applications given their long-lived fuel source, compact size, portability, reliability as it relates to safety and their self-regulating nature. To take advantage of these opportunities there are technological challenges that need to be overcome. One advancing technology often used in conjunction with microreactor designs are heat pipes, which are used for heat removal from the reactor core to the power conversion system. Heat pipes are a substitute for the traditional system in which the same fluid used as coolant in the reactor is then used as the working fluid in the power conversion system. This document describes how heat pipes operate, what happens when a heat pipe fails, and what codes can be used to simulate the results. Our analyses show that a single/double heat pipe failure results in a temperature increase of 15-50°C respectively in surrounding heat pipes. Heat pipe microreactors could be easily designed such that this increase is within the maximum parameters allowable for safety and does not result in cascading heat pipe failure. Thus, such failures do not lead to severe degradation of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗