Concept for a power system controller for large space electrical power systems

The development of technology for a fail-operatonal power system controller (PSC) utilizing microprocessor technology for managing the distribution and power processor subsystems of a large multi-kW space electrical power system is discussed. The specific functions which must be performed by the PSC, the best microprocessor available to do the job, and the feasibility, cost savings, and applications of a PSC were determined. A limited function breadboard version of a PSC was developed to demonstrate the concept and potential cost savings.

Lollar, L. F.↗

Fluidic power control systems

Pneumatic and hydraulic fluidic power control systems, discussing moving part position servos and cold gas reaction systems

Rose, R. K.↗

Improved control system power unit for large parachutes

Improved control system power unit drives the control surfaces of very large controllable parachutes. The design features subassemblies for determining control surface position and cable loading, and protection of the load sensor against the possibility of damage during manipulation.

Chandler, J. A.↗

Fiber-Optic Equipment for Power-System Control

Report surveys state of art in fiber optics and explores use of microprocessors communicating over optical fibers to control complicated power system with many producing and consuming units. Power system of study is of planetary spacecraft, and fiber-optic technology extension of that now under development or used in military aircraft and ships.

Bridgeforth, A. O.↗

Ground Simulator Studies of the Effects of Valve Friction, Stick Friction, Flexibility, and Backwash on Power Control System Quality

Report presents results of tests made on a power control system by means of a ground simulator to determine the effects of various combinations of valve friction and stick friction on the ability of the pilot to control the system. Various friction conditions were simulated with a rigid control system, a flexible system, and a rigid system having some backlash. For the tests, the period and damping of the simulated airplane were held constant.

Brown, B Porter↗

Ground Simulator Studies of a Nonlinear Linkage in a Power Control System

An investigation was made to determine the characteristics of a nonlinear linkage installed in a power control system incorporated in a ground simulator. The nonlinear linkage provided for increased control-stick motion for relatively small simulator response at control motions near neutral. The quality of the control system was rated on the ease and precision with which various tracking tasks were performed by the pilots who operated the simulator. The results obtained with the nonlinear linkage installed in the control system were compared with those obtained by using the normal linear control system. Several combinations of nonlinearity of the linkage were tested for various dynamic characteristics of the simulator. It was found that the pilots were able to track almost as well with the nonlinear linkage installed as with the normal system. All of the pilots were of the opinion, however, that the nonlinearity was an undesirable feature in the control system because of the apparent lack of simulator response through the neutral range of the linkage where relatively large stick deflections could be made with very little simulator motion. The results showed that increased lag between the target and chair position, higher stick-force levels, and uneven stick forces due to the dynamics of the linkage were general characteristics of all the nonlinear linkage conditions tested. It was also found that for cases of low simulator damping, rapid control motions caused considerably higher overshoots when the nonlinear linkage was installed than were obtained for the normal linear control system. These characteristics were considered to be sufficiently undesirable to out-weigh the advantages to be gained from the use of a nonlinear linkage in the control system of an airplane.

Assadourian, Arthur↗

Flight Evaluation of Several Spring Force Gradients and a Bobweight in the Cyclic-Power-Control System of a Light Helicopter

Several feel springs of different rates were evaluated in the power-control system of a light helicopter. In addition, a bobweight and viscous damper for providing maneuvering forces were evaluated. The evaluation was qualitative, based upon the combined opinions of eight research pilots and four non-pilot engineers from NASA. The evaluation revealed that desirable all-around forces for the helicopter were obtained with a 1/2-lb/in. feel spring for both longitudinal and lateral control combined with a 14-lb/g bobweight. Further investigation proved the necessity of the viscous damper in the bobweight system.

Mallick, Donald L.↗

Microprocessor control for standardized power control systems

The use of microcomputers in space-oriented power systems as a replacement for existing inflexible analog type controllers has been proposed. This study examines multiprocessor systems, various modularity concepts and presents a conceptualized power system incorporating a multiprocessor controller as well as preliminary results from a breadboard model of the proposed system.

Green, D. G.↗

Lagged low order control systems with powered controls

With powered controls, a high order control system can be changed to a lower order control system with a lag, which is better suited to our position control skills and strategies. Separate groups of untrained men were trained on an acceleration control system, or on a rate control system with an exponential lag of either .5, 2, or 4 sec. Acquisition time was reliably shorter with all the lagged rate control systems than with the unlagged acceleration control system.

Poulton, E. C.↗

A CLIPS prototype for autonomous power system control

The model of the system assumes a constant power source and loads (experiments) whose power demands exceed the supply. Experiments are described by their name, power consumption, time for a complete run, present status and the state of the load. The power consumption of each load is set at a constant level but can be dynamically modified by the operator. The status specifies if the experiment is running, paused, completed or failed. The state compensates for the lack of actual feedback sensor data, by signifying the stability of the load. Experiments are scheduled to keep as many running as possible with the current system limitations. A graphics oriented user interface is embedded into the rule-based system to enable an operator to easily experiment with the system.

Vezina, James M.↗

Description of the SSF PMAD DC testbed control system data acquisition function

The NASA LeRC in Cleveland, Ohio has completed the development and integration of a Power Management and Distribution (PMAD) DC Testbed. This testbed is a reduced scale representation of the end to end, sources to loads, Space Station Freedom Electrical Power System (SSF EPS). This unique facility is being used to demonstrate DC power generation and distribution, power management and control, and system operation techniques considered to be prime candidates for the Space Station Freedom. A key capability of the testbed is its ability to be configured to address system level issues in support of critical SSF program design milestones. Electrical power system control and operation issues like source control, source regulation, system fault protection, end-to-end system stability, health monitoring, resource allocation, and resource management are being evaluated in the testbed. The SSF EPS control functional allocation between on-board computers and ground based systems is evolving. Initially, ground based systems will perform the bulk of power system control and operation. The EPS control system is required to continuously monitor and determine the current state of the power system. The DC Testbed Control System consists of standard controllers arranged in a hierarchical and distributed architecture. These controllers provide all the monitoring and control functions for the DC Testbed Electrical Power System. Higher level controllers include the Power Management Controller, Load Management Controller, Operator Interface System, and a network of computer systems that perform some of the SSF Ground based Control Center Operation. The lower level controllers include Main Bus Switch Controllers and Photovoltaic Controllers. Power system status information is periodically provided to the higher level controllers to perform system control and operation. The data acquisition function of the control system is distributed among the various levels of the hierarchy. Data requirements are dictated by the control system algorithms being implemented at each level. A functional description of the various levels of the testbed control system architecture, the data acquisition function, and the status of its implementationis presented.

Baez, Anastacio N.↗

Steady-state and dynamic characteristics of a 20-kHz spacecraft power system - Control of harmonic resonance

A detailed computer simulation was used to illustrate the steady-state and dynamic operating characteristics of a 20-kHz resonant spacecraft power system. The simulated system consists of a parallel-connected set of DC-inductor resonant inverters (drivers), a 440-V cable, a node transformer, a 220-V cable, and a transformer-rectifier-filter (TRF) AC-to-DC receiver load. Also included in the system are a 1-kW 0.8-pf RL load and a double-LC filter connected at the receiving end of the 20-kHz AC system. The detailed computer simulation was used to illustrate the normal steady-state operating characteristics and the dynamic system performance following, for example, TRF startup. It is shown that without any filtering the given system exhibits harmonic resonances due to an interaction between the switching of the source and/or load converters and the AC system. However, the double-LC filter at the receiving-end of the AC system and harmonic traps connected in series with each of the drivers significantly reduce the harmonic distortion of the 20-kHz bus voltage. Significant additional improvement in the waveform quality can be achieved by including a double-LC filter with each driver.

Wasynczuk, O.↗

Flywheel Single-Axis Integrated Momentum and Power Control System Demonstrated

On July 10, 2003, the NASA Glenn Research Center flywheel team experimentally demonstrated a two-flywheel-module system that simultaneously provided attitude control in a single axis and regulated power. The test was conducted using the D1 flywheel module and the high-speed shaft (HSS) in the High Energy Flywheel Facility (HEFF). Both of these flywheel modules consist of a magnetically levitated rotor with an integral motor/generator, a vacuum housing, and mechanical touchdown bearings. Energy is stored kinetically in the rotor. The motor/generator allows energy to be added to or withdrawn from the rotor, and magnetic bearings and a vacuum enclosure are used to minimize losses.

Soeder, James F.↗