Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

MAMBA: A Prototype Modern Modular Bubble Chamber for Precision Measurement of Neutrino Nucleus Cross Sections

High precision measurements of neutrino interactions are essential for the success of future neutrino oscillation experiments. Understanding the interaction rate and precise energy spectrum requires understanding of neutrino interactions and nuclear effects. Measuring interactions in a light nuclear target , such as Hydrogen or deuterium, would provide highly valuable input to reduce reduce the uncertainties associated with neutrino-nucleus cross sections, relevant for upcoming experiments like the Deep Underground Neutrino Experiment (DUNE) and Hyper-Kamiokande (Hyper-K). A bubble chamber presents an opportunity to study a light nuclear target using hydrogen in the liquid phase as a working fluid. However historical hydrogen bubble chamber designs if placed in modern neutrino beams would miss a significant fraction of the total number of available interactions. We present a bubble chamber prototype, MAMBA, which will be used to investigate strategies for inexpensively enabling continuous cycling through improved cooling at scale and expanding the active time of historic bubble chambers. MAMBA aims to demonstrate the feasibility of precision neutrino–nucleon measurements at conditions comparable to modern beams.

Martínez Casales, María [Fermilab] (ORCID:00000003↗

Metering gun for dispensing precisely measured charges of fluid

A cyclically operable fluid dispenser for use in dispensing precisely measured charges of potable water aboard spacecraft is described. The dispenser is characterized by (1) a sealed housing adapted to be held within a crewman's palm and coupled with a pressurized source of potable water; (2) a dispensing jet projected from the housing and configured to be received within a crewman's lips; (3) an expansible measuring chamber for measuring charges of drinking water received from the source; (4) and a dispenser actuator including a lever extended from the housing to be digitated for initiating operational cycles, whereby precisely measured charges of potable water selectively are delivered for drinking purposes in a weightless environment.

Cook, T. A.↗

Precision Measurement of Net-Proton-Number Fluctuations in Au + Au Collisions at RHIC

We report precision measurements on cumulants (𝐶 𝑛 ) and factorial cumulants (𝜅 𝑛 ) of (net) proton number distributions up to fourth order in Au + Au collisions over center-of-mass energies $\sqrt{s_{NN}}$ = 7.7–27 GeV from phase II of the Beam Energy Scan program at RHIC. (Anti)protons are selected at midrapidity (|𝑦| < 0.5) within a transverse momentum range of 0.4 < 𝑝 𝑇 < 2.0 GeV/𝑐. Relative to various noncritical-point model calculations and peripheral collision 70%–80% data, the net proton 𝐶 4 /𝐶 2 measurement in 0%–5% collisions shows a minimum around 19.6 GeV for significance of deviation at ∼2–5⁢𝜎. A minimum in 𝐶 4 /𝐶 2 with respect to a noncritical baseline is expected to be a characteristic feature of the signature associated with a critical point in the QCD phase diagram. In addition, deviations from noncritical baselines around the same collision energy region are also seen in proton factorial cumulant ratios, especially in 𝜅 2 /𝜅 1 and 𝜅 3 /𝜅 1 . As a result, dynamical model calculations including a critical point are called for in order to understand these precision measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of Planar-Waveguide External Cavity Laser for Precision Measurements

A 1542-nm planar-waveguide external cavity laser (PW-ECL) is shown to have a sufficiently low level of frequency and intensity noise to be suitable for precision measurement applications. The frequency noise and intensity noise of the PW-ECL was comparable or better than the nonplanar ring oscillator (NPRO) and fiber laser between 0.1 mHz to 100 kHz. Controllability of the PW-ECL was demonstrated by stabilizing its frequency to acetylene (13C2H2) at 10(exp -13) level of Allan deviation. The PW-ECL also has the advantage of the compactness of a standard butterfly package, low cost, and a simple design consisting of a semiconductor gain media coupled to a planar-waveguide Bragg reflector. These features would make the PW-ECL suitable for precision measurements, including compact optical frequency standards, space lidar, and space interferometry

Numata, Kenji↗

High precision measurement of stellar radial velocity variations

New techniques for the high precision measurement of variations in stellar radial velocities now allow a precision of better than 5 m/s to be obtained in routine telescopic observations. Some of the factors limiting velocity precision and how they can be overcome are discussed. Also presented are applications of these new techniques to the problems of detection of planetary systems around other stars and the use of stellar oscillations to determine interior properties of the stars.

Cochran, William D.↗

R ( 3780 ) Resonance Interpreted as the 1 D 1 3 -Wave Dominant State of Charmonium from Precise Measurements of the Cross Section of e + e − → Hadrons

We report the precise measurements of the cross section of e + e − → hadrons at center-of-mass energies from 3.645 to 3.871 GeV. We thereby perform the most precise study of the cross sections and find a complex system composed of three resonances of R ( 3760 ) , R ( 3780 ) , and R ( 3810 ) . For the first time, we measure the R ( 3810 ) electronic width to be ( 19.4 ± 7.4 ± 12.1 ) eV . For the R ( 3760 ) resonance, we measure the mass to be ( 3751.9 ± 3.8 ± 2.8 ) MeV / c 2 , the total width to be ( 32.8 ± 5.8 ± 8.7 ) MeV , and the electronic width to be ( 184 ± 75 ± 86 ) eV . For the R ( 3780 ) resonance, we measure its mass to be ( 3778.7 ± 0.5 ± 0.3 ) MeV / c 2 , total width to be ( 20.3 ± 0.8 ± 1.7 ) MeV , and electronic width to be ( 265 ± 67 ± 83 ) eV . Forty-seven years ago, the ψ ( 3770 ) resonance was discovered, and was subsequently interpreted as the 1 D 1 3 -wave dominant state of charmonium. However, our analysis of the total-hadron cross sections indicates that the ψ ( 3770 ) is not a single state, but a complex system composed of the R ( 3760 ) , R ( 3780 ) , and R ( 3810 ) resonances. Among these, we interpret the R ( 3780 ) is a resonance dominated by the 1 D 1 3 charmonium state. Published by the American Physical Society 2024

Ablikim, M.↗

Precision measurements of photoabsorption cross sections of Ar, Kr, Xe, and selected molecules at 58.4, 73.6, and 74.4 nm

Absolute absorption cross sections have been measured for the rare gases at 58.43, 73.59, and 74.37 nm with an accuracy of + or - 0.8 percent. For the molecules H2, N2, O2, CO, N2O, CO2, and CH4, precision measurements were made at 58.43 nm with an accuracy of + or - 0.8 percent. Molecular absorption cross sections are also reported at 73.59 and 74.37 nm. However, in the vicinity of these wavelengths most molecules exhibit considerable structure, and cross sections measured at these wavelengths may depend on the widths and the amounts of self-reversal of these resonance lines. A detailed discussion is given of the systematic errors encountered with the double-ion chamber used in the cross-sectional measurements. Details are also given of precision pressure measurements.

Samson, James A. R.↗

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand's Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the funda- mental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scatter- ing provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon’s internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (Gn M ) to unprecedented Q2 using Durand’s method, also known as the “ratio” method. Systematic errors are greatly reduced by extracting Gn M from the ratio of neutron-coincident (D(e, e'n)) to proton-coincident (D(e, e'p)) quasi-elastic electron scattering from deuteron. The scattered electrons were detected in the BigBite spectrometer, which features multiple Gas Elec- tron Multiplier (GEM) layers with large active area for high-precision tracking at very high rates. Simultaneous nucleon detection was performed by the Super BigBite spectrometer, which utilizes a dipole magnet with large solid angle acceptance at forward angles and a novel hadron calorimeter with very high and comparable detection efficiencies for both protons and neutrons. This setup could handle very high luminosity, making high-Q2 measurements feasible. Data were collected at five Q2 points: 3, 4.5, 7.4, 9.9, and 13.6 (GeV/c)2. Preliminary results are reported for all, with the lowest two Q2 points in good agreement with existing world data, while the higher points significantly extend the Q2 range in which Gn M is known accurately. The precision of the highest Q2 point is expected to remain unmatched for years to come.

Datta, Provakar↗

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand’s Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the fundamental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scattering provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon's internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (GMn) to unprecedented Q2 using Durand's method, also known as the "ratio" method. Systematic errors are greatly reduced by ext

Datta, Provakar↗

Precision measurements of EFT parameters and BAO peak shifts for the Lyman- α forest

We present precision measurements of the bias parameters of the one-loop power spectrum model of the Lyman- α (Ly- α ) forest, derived within the effective field theory (EFT) of large-scale structure. We fit our model to the three-dimensional flux power spectrum measured from the ACCEL 2 hydrodynamic simulations. The EFT model fits the data with an accuracy of below 2% up to k = 2 h Mpc − 1 . Further, we analytically derive how nonlinearities in the three-dimensional clustering of the Ly- α forest introduce biases in measurements of the baryon acoustic oscillations (BAOs) scaling parameters in radial and transverse directions. From our EFT parameter measurements, we obtain a theoretical error budget of Δ α ∥ = − 0.2 % ( Δ α ⊥ = − 0.3 % ) for the radial (transverse) parameters at redshift z = 2.0 . This corresponds to a shift of − 0.3 % (0.1%) for the isotropic (anisotropic) distance measurements. We provide an estimate for the shift of the BAO peak for Ly- α -quasar cross-correlation measurements assuming analytical and simulation-based scaling relations for the nonlinear quasar bias parameters resulting in a shift of − 0.2 % ( − 0.1 % ) for the radial (transverse) dilation parameters, respectively. This analysis emphasizes the robustness of Ly- α forest BAO measurements to the theory modeling. We provide informative priors and an error budget for measuring the BAO feature—a key science driver of the currently observing Dark Energy Spectroscopic Instrument (DESI). Our work paves the way for full-shape cosmological analyses of Ly- α forest data from DESI and upcoming surveys such as the Prime Focus Spectrograph, WEAVE-QSO, and 4MOST. Published by the American Physical Society 2025

de Belsunce, Roger (ORCID:0000000336604028)↗

Precision measurement of the longitudinal double-spin asymmetry for dijet production at intermediate pseudorapidity in polarized 𝑝⁢𝑝 collisions at $\sqrt{s}$ = 200 GeV

The STAR Collaboration reports precise measurements of the longitudinal double-spin asymmetry, 𝐴 𝐿⁢𝐿 , for dijet production with at least one jet at intermediate pseudorapidity 0.8 < 𝜂 jet < 1.8 in polarized proton-proton collisions at a center-of-mass energy of 200 GeV. This study explores partons scattered with a longitudinal momentum fraction (𝑥) from 0.01 to 0.5, which are predominantly characterized by interactions between high-𝑥 valence quarks and low-𝑥 gluons. The results are in good agreement with previous measurements at 200 GeV with improved precision and are found to be consistent with the predictions of global analyses that find the gluon polarization to be positive. In contrast, the negative gluon polarization solution from the JAM Collaboration is found to be strongly disfavored.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

U-238-U-234-Th-230-Th-232 systematics and the precise measurement of time over the past 500,000 years

A method is presented for the high-precision measurement of the Th-230 abundance in corals by isotope-dilution mass spectrometry using techniques developed by Chen and Wasserburg (1980, 1981) and Chen et al. (1986). It is shown that 6 x 10 to the 8th atoms of Th-230 can be measured to + or - 30 percent (2 sigma) and 2 x 10 to the 10th atoms of Th-230 to + or - 2 percent. The time over which useful age data on corals can be obtained ranges from a few years to about 500 ky, with the uncertainty in age ranging from 5 y for a 180-y-old coral, to 44 y for a 8294-y-old coral, to 1.1 ky for a 123.1-ky-old coral. Ages were determined with high analytical precision for several corals that grew during high sea-level stands about 120 ky ago, supporting the view that the dominant cause of Pleistocene climate change was Milankovitch forcing.

Edwards, R. Lawrence↗

Precise Measurements of the Density and Critical Phenomena Near Phase Transitions in Liquid Helium

The first-year progress for the project of precise measurements of the density and critical phenomena of helium near phase transitions is summarized below: (1) completion of a cryogenic sample probe for the proposed measurements, and the rehabilitation of a designated laboratory at Caltech for this project; (2) construction and testing of a superconducting niobium cavity; (3) acquisition of one phase-locked-loop system for high-resolution frequency control and read- out; (4) setting up high-resolution thermometry (HRT) for temperature readout and control; (5) developing new approaches for calibrating the coefficient between the resonant frequency shift (delta f) and the helium density (rho), as well as for measuring the effect of gravity on T(sub lambda) to a much better precision; (6) programming of the interface control of all instruments for automatic data acquisition; and (7) improving data analyses and fitting procedures.

Yeh, Nai-Chang↗

Precision measurement of the Ξ b − baryon lifetime

A sample of p p collision data, corresponding to an integrated luminosity of 5.5 fb − 1 and collected by the LHCb experiment during LHC Run 2, is used to measure the ratio of the lifetime of the Ξ b − baryon to that of the Λ b 0 baryon, r τ ≡ τ Ξ b − / τ Λ b 0 . The value r τ = 1.076 ± 0.013 ± 0.006 is obtained, where the first uncertainty is statistical and the second systematic. This value is averaged with the corresponding value from Run 1 to obtain r τ Run 1 , 2 = 1.078 ± 0.012 ± 0.007 . Multiplying by the world-average value of the Λ b 0 lifetime yields τ Ξ b − Run 1 , 2 = 1.578 ± 0.018 ± 0.010 ± 0.011 ps , where the uncertainties are statistical, systematic, and due to the limited knowledge of the Λ b 0 lifetime. This measurement improves the precision of the current world average of the Ξ b − lifetime by about a factor of 2, and is in good agreement with the most recent theoretical predictions. © 2024 CERN, for the LHCb Collaboration 2024 CERN

Aaij, R. (ORCID:0000000305331952)↗