At least 19 records

Pressure Lag in Tubing Used in Flight Research

Tests described in this report were undertaken to obtain a quantitative measure of the pressure lag in typical pressure-tubing systems used by the Ames Aeronautical Laboratory in flight research investigations. Lag measurements were made with both single-direction and oscillating pressure changes. Single-direction pressure changes were investigated to determine if the lag in orifice-pressure lines and in the research airspeed and altitude measuring systems of pursuit-type airplane undergoing flight tests was sufficient to cause an appreciable error in the record of a sudden pressure change. Oscillating pressure changes were investigated with particular reference to the accuracy of pressure peaks in pressure-distribution measurements during the time of buffeting conditions as found in stalls. (author)

Turner, Howard L↗

High-Sensitivity, Broad-Range Vacuum Gauge Using Nanotubes for Micromachined Cavities

A broad-range vacuum gauge has been created by suspending a single-walled carbon nanotube (SWNT) (metallic or semiconducting) in a Schottky diode format or in a bridge conductor format, between two electrically charged mesas. SWNTs are highly sensitive to molecular collisions because of their extremely small diameters in the range of 1 to 3 nanometers. The measurement parameter will be the change in conductivity of SWNT due to decreasing rate of molecular collisions as the pressure inside a chamber decreases. The rate of heat removal approaches a saturation limit as the mean free path (m.f.p.) lengths of molecules increase due to decreasing pressure. Only those sensing elements that have a long relaxation time can produce a measureable response when m.f.p. of molecules increases (or time between two consecutive collisions increases). A suspended SWNT offers such a capability because of its one-dimensional nature and ultrasmall diameter. In the initial approach, similar architecture was used as that of a SWNT-Schottky diode that has been developed at JPL, and has its changing conductivity measured as the test chamber is pumped down from atmospheric pressure to high vacuum (10(exp -7) Torr). Continuous response of decreasing conductivity has been measured as a function of decreasing pressure (SWNT is a negative thermal coefficient material) from atmosphere to less than 10(exp -6) Torr. A measureable current change in the hundreds of nA range has been recorded in the 10(exp -6) Torr regime.

Manohara, Harish↗

Space Suit Survivability Enhancement NASA Research Announcement 96-OLMSA-01B: Advanced Life Support and Environmental Technologies for Human Exploration and Development of Space

Conducted two meetings to review the project scope and develop concepts for self-sealing material compositions, Focus has been on developing concepts that would seal a penetration enough to allow the astronauts to re-enter the spacecraft within the window provided by the emergency air supply. Concepts discussed include: quilted fabrics containing a viscous flow material in the quilted cells which would seal the bladder breach when forced to flow by the internal suit pressure; a sealant impregnated felt liner which acts similar to above; and a "blousy" fibrous layer which would mechanically plug a rupture under pressure. Illustrations of the above concepts are included in the attached viewgraphs, which were used in a presentation. The most promising of these concepts will be made into prototypes for testing. ILC has developed a test fixture to test the scaling characteristics of various material layups by measuring real-time changes in pressure and make-up flow in a pressurized cylinder. Candidate viscous sealing compounds such as silicones and urethanes have been identified. These compounds will be coated on existing bladder cloth for initial tests. The most promising compounds will be integrated into the above material structures for final testing. Design and analysis of fabric weaves to improve cut and puncture resistance of the suit TMG layers is underway. Philadelphia Textile is developing a mathematical model to correlate yarn type and weave structure to cut and tear resistance. The computer mathematical modeling of the fabric failure mechanisms by Cornell University, as originally proposed, will be replaced with the above model and empirical testing methods, due to the loss of key Cornell personnel.

Source record↗

Sympathetic responses to Valsalva's manoeuvre following bed rest

The purpose of this study was to examine whether 14 days of head-down tilt bed rest (HDBR) alters autonomic regulation during Valsalva's manoeuvre (VM) and if this would predict blood pressure control during a 60 degrees head-up tilt (HUT) test. To examine autonomic control of blood pressure, we measured the changes in systolic (delta SBP) and diastolic (delta DBP) blood pressure between baseline and the early straining (Phase IIE) period of VM (20 sec straining to 40 mmHg; N = 7) in conjunction with changes in muscle sympathetic nerve activity (MSNA; microneurography) burst frequency (B/min) and total activity (% delta) from baseline over the 20-sec straining period. MSNA data were successfully recorded from 6 of the 7 individuals. The averaged responses from three repeated VMs performed in the supine position were compared between the pre- and post-HDBR tests. Compared with the pre-HDBR test, a greater reduction in SBP, DBP, and MAP was observed during Phase IIE following HDBR, p < 0.05. The increase in MSNA burst frequency during straining was augmented in the post- compared with the pre-HDBR test, p < 0.0001, as was the Phase IV blood pressure overshoot, p < 0.05. Although all subjects completed the 20-min pre-HDBR tilt test without evidence of hypotension or orthostatic intolerance, the post-HDBR test was stopped early in 5 of the 7 subjects due to systolic hypotension. The responses during the VM suggest that acute autonomic adjustments to rapid blood pressure changes are preserved after bed rest. Furthermore, MSNA and blood pressure responses during VM did not predict blood pressure control during orthostasis following HDBR.

NASA Discipline Musculoskeletal↗

Rotating pressure measurement system using an on board calibration standard

A computer-controlled multichannel pressure measurement system was developed to acquire detailed flow field measurements on board the Large Low Speed Centrifugal Compressor Research Facility at the NASA Lewis Research Center. A pneumatic slip ring seal assembly is used to transfer calibration pressures to a reference standard transducer on board the compressor rotor in order to measure very low differential pressures with the high accuracy required. A unique data acquisition system was designed and built to convert the analog signal from the reference transducer to the variable frequency required by the multichannel pressure measurement system and also to provide an output for temperature control of the reference transducer. The system also monitors changes in test cell barometric pressure and rotating seal leakage and provides an on screen warning to the operator if limits are exceeded. The methods used for the selection and testing of the the reference transducer are discussed, and the data acquisition system hardware and software design are described. The calculated and experimental data for the system measurement accuracy are also presented.

Senyitko, Richard G.↗

Measured and predicted pressure distributions on the AFTI/F-111 mission adaptive wing

Flight tests have been conducted using an F-111 aircraft modified with a mission adaptive wing (MAW). The MAW has variable-camber leading and trailing edge surfaces that can change the wing camber in flight, while preserving smooth upper surface contours. This paper contains wing surface pressure measurements obtained during flight tests at Dryden Flight Research Facility of NASA Ames Research Center. Upper and lower surface steady pressure distributions were measured along four streamwise rows of static pressure orifices on the right wing for a leading-edge sweep angle of 26 deg. The airplane, wing, instrumentation, and test conditions are discussed. Steady pressure results are presented for selected wing camber deflections flown at subsonic Mach numbers up to 0.90 and an angle-of-attack range of 5 to 12 deg. The Reynolds number was 26 million, based on the mean aerodynamic chord. The MAW flight data are compared to MAW wind tunnel data, transonic aircraft technology (TACT) flight data, and predicted pressure distributions. The results provide a unique database for a smooth, variable-camber, advanced supercritical wing.

Webb, Lannie D.↗

Physisorption of Ar, Kr, CH4, and N2 on 304 stainless steel at very low pressures.

Determination of physisorption isotherms of these gases on stainless steel by pressure change measurements in very low pressure cryogenic baths where a steel nipple was brought in contact with the test gas at 77 to 90 K in a sealed constant-volume system. The position of the nipple in the gas was changed in such a manner that gas adsorption on a 47.5 sq cm area of the steel surface could be measured. The Dubinin-Radushkevich (DR) equation (1947) was used for an empirical description of isotherms at different temperatures. The mean adsorption energies calculated from the DR plots were 1290, 1545, 1490 and 1903 cal/mol for Ar, Kr, CH4 and N2, respectively, being about 10% higher than the corresponding values on Pyrex.

Troy, M.↗

Fabrication and Testing of a Thin-Film Heat Flux Sensor for a Stirling Convertor

The NASA Glenn Research Center (GRC) has been testing high efficiency free-piston Stirling convertors for potential use in radioisotope power systems since 1999. Stirling convertors are being operated for many years to demonstrate a radioisotope power system capable of providing reliable power for potential multi-year missions. Techniques used to monitor the convertors for change in performance include measurements of temperature, pressure, energy addition, and energy rejection. Micro-porous bulk insulation is used in the Stirling convertor test set up to minimize the loss of thermal energy from the electric heat source to the environment. The insulation is characterized before extended operation, enabling correlation of the net thermal energy addition to the convertor. Aging microporous bulk insulation changes insulation efficiency, introducing errors in the correlation for net thermal energy addition. A thin-mm heat flux sensor was designed and fabricated to directly measure the net thermal energy addition to the Stirling convertor. The fabrication techniques include slip casting and using Physical Vapor Deposition (PVD). One micron thick noble metal thermocouples measure temperature on the surface of an Alumina ceramic disc and heat flux is calculated. Fabrication, integration, and test results of a thin film heat flux sensor are presented.

Wilson, Scott D.↗

Fabrication and Testing of a Thin-Film Heat Flux Sensor for a Stirling Convertor

The NASA Glenn Research Center (GRC) has been testing high-efficiency free-piston Stirling convertors for potential use in radioisotope power systems since 1999. Stirling convertors are being operated for many years to demonstrate a radioisotope power system capable of providing reliable power for potential multiyear missions. Techniques used to monitor the convertors for change in performance include measurements of temperature, pressure, energy addition, and energy rejection. Micro-porous bulk insulation is used in the Stirling convertor test setup to minimize the loss of thermal energy from the electric heat source to the environment. The insulation is characterized before extended operation, enabling correlation of the net thermal energy addition to the convertor. Aging micro-porous bulk insulation changes insulation efficiency, introducing errors in the correlation for net thermal energy addition. A thin-film heat flux sensor was designed and fabricated to directly measure the net thermal energy addition to the Stirling convertor. The fabrication techniques include slipcasting and using Physical Vapor Deposition (PVD). One-micron-thick noble metal thermocouples measure temperature on the surface of an alumina ceramic disk and heat flux is calculated. Fabrication, integration, and test results of a thin-film heat flux sensor are presented.

Wilson, Scott D.↗

Long duration biaxial cylinder testing of balloon grade polyethylene films with emphasis on automated data acquisition and control

Characterization of a 2-dimensional material constitutive model in the practical biaxial state for engineering utility of balloon envelope structural analysis is achievable with laboratory cylinder tests. Hoop (circumferential, and longitudinal strains are time-wise measured on axially loaded pressurized cylinders. Pre-programmed ramped loading changes as well as precise long term pressure control are achieved through cascaded proportional, integral derivative (PID) flow control loops that are part of an integrated data acquisition and process control system. Real time data reduction and analysis allow monitoring of unattended tests that have durations of up to a month. Measured and controlled parameters and variables are discussed; date analysis techniques are reviewed.

Martone, Michael↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

Effect of simulated hyperemia on the flow field in a mildly atherosclerotic coronary artery casting of man

Changes in an arterial flow field due to mild atherosclerosis were determined using a main coronary artery casting with a maximum obstruction of about 50 percent by area. Local pressure changes were measured using six pressure tap holes along the wall of the casting. The test-fluid was a 33 percent sugar-water solution of approximately the same viscosity as human blood. Flow visualization results were obtained by injecting blue-dye through the pressure tap holes. Measurement of local pressure demonstrated a significant Reynolds number effect. At Reynolds numbers of 80-710, a local pressure rise was observed downstream of the mild atherosclerotic constriction due to momentum changes. The Reynolds number necessary for flow separation in the divergent region of the coronary casting was about 330. The experimental results can be used to obtain a quantitative relation between coronary morphology and the fluid dynamic consequences of mild diffuse disease under conditions of maximum cardiac demand i.e., higher coronary flow rates and Reynolds numbers associated with space and atmospheric flight.

Cho, Y. I.↗

Fluidic Control of Nozzle Flow: Some Performance Measurements

Results are presented of an experimental program that investigated the use of a secondary air stream to control the amount of flow through a convergent-divergent nozzle. These static tests utilized high pressure, ambient temperature air that was injected at the throat of the nozzle through an annular slot. Multiple injection slot sizes and injection angles were tested. The introduction of secondary flow was made in an opposing direction to the primary flow and the resulting flow field caused the primary stream to react as though the physical throat size had been reduced. The percentage reduction in primary flow rate was generally about twice the injected flow rate. The most effective throttling was achieved by injecting through the smallest slot in an orientation most nearly opposed to the approaching primary flow. Thrust edliciency, as measured by changes in nozzle thrust coefficient, was highest at high nozzle pressure ratios, NPR. The static test results agreed with predictions obtained prior from PABSD, a fully viscous computational fluid dynamics program. Since use of such an injection system on gas turbine engine exhaust nozzles would be primarily at high NPRs, it was concluded that fluidic control holds promise for reducing nozzle weight and complexity on future systems.

Federspiel, John↗

Wind Tunnel Test of an RPV with Shape-Change Control Effector and Sensor Arrays

A variety of novel control effector concepts have recently emerged that may enable new approaches to flight control. In particular, the potential exists to shift the composition of the typical aircraft control effector suite from a small number of high authority, specialized devices (rudder, aileron, elevator, flaps), toward larger numbers of smaller, less specialized, distributed device arrays. The concept envisions effector and sensor networks composed of relatively small high-bandwidth devices able to simultaneously perform a variety of control functions using feedback from disparate data sources. To investigate this concept, a remotely piloted flight vehicle has been equipped with an array of 24 trailing edge shape-change effectors and associated pressure measurements. The vehicle, called the Multifunctional Effector and Sensor Array (MESA) testbed, was recently tested in NASA Langley's 12-ft Low Speed wind tunnel to characterize its stability properties, control authorities, and distributed pressure sensitivities for use in a dynamic simulation prior to flight testing. Another objective was to implement and evaluate a scheme for actively controlling the spanwise pressure distribution using the shape-change array. This report describes the MESA testbed, design of the pressure distribution controller, and results of the wind tunnel test.

Raney, David L.↗

Fluid Shifts: Otoacoustical Emission Changes in Response to Posture and Lower Body Negative Pressure

INTRODUCTION: The purpose of the NASA Fluid Shifts Study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight and to correlate these findings with vision changes and other elements of the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. Due to the invasive nature of direct measures of ICP, a noninvasive technique of monitoring ICP is desired for use during spaceflight. The phase angle and amplitude of otoacoustic emissions (OAEs) have been shown to be sensitive to posture change and ICP (1, 2), therefore use of OAEs is an attractive option. OAEs are low-level sounds produced by the sensory cells of the cochlea in response to auditory stimulation. These sounds travel peripherally from the cochlea, through the oval window, to the ear canal where they can be recorded. OAE transmission is sensitive to changes in the stiffness of the oval window, occurring as a result of changes in cochlear pressure. Increased stiffness of the oval window largely affects the transmission of sound from the cochlea at frequencies between 800 Hz and 1600 Hz. OAEs can be self-recorded in the laboratory or on the ISS using a handheld device. Our primary objectives regarding OAE measures in this experiment were to 1) validate this method during preflight testing of each crewmember (while sitting, supine and in head-down tilt position), and 2) determine if OAE measures (and presumably ICP) are responsive to lower body negative pressure and to spaceflight. METHODS: Distortion-product otoacoustic emissions (DPOAEs) and transient evoked otoacoustic emissions (TEOAEs) were recorded preflight using the Otoport Advance OAE system (Otodynamics Ltd., Hatfield, UK). Data were collected in four conditions (seated, supine, 15 degrees head down tilt (HDT), and 15 degrees HDT with lower body negative pressure (LBNP)) to produce a range of ICP in each subject and test the susceptibility of OAEs to LBNP. LBNP was induced using the Russian Chibis suit to produce the same fit and pressures that would be experienced inflight during Chibis LBNP trials. Similar trials have occurred inflight on the ISS. A comparative analysis of preflight and inflight phase measurements and magnitudes was completed in both broad and narrow band frequency ranges. RESULTS: TEOAE data demonstrated notable phase shifts from 859-1640 Hz when the seated baseline condition is compared to supine, HDT, and HDT plus Chibis conditions. Changes were particularly pronounced at low frequencies and were consistent with the expected ICP changes. Preflight DPOAE magnitude data revealed changes consistent with increased ICP in two conditions at 1414 Hz, where a magnitude change (relative to the seated condition) was seen in the HDT position and in HDT plus Chibis. DISCUSSION: OAEs revealed systematic changes in phase and magnitude throughout all test conditions (including use of Chibis LBNP) that were consistent with ICP changes. Results indicate that OAEs may provide a rapid noninvasive means of monitoring ICP changes. The first two subjects are projected to complete inflight testing on the ISS in early 2016, with the full complement of 10 subjects scheduled to be complete in 2018.

Melgoza, R.↗

Two-stage gas measurement system

A quick-response, real-time gaseous measurement system allows for the continuous sampling of a low pressure gaseous environment. A sample of test gas from the low pressure gaseous environment is continuously extracted and pumped to a structural tee joint which is open to the atmosphere at one end to maintain the test gas at a constant pressure. The structural tee joint communicates at the other end with a heater for maintaining the test gas at a constant temperature. From the heater, the test gas is sent to a sensor which develops a voltage that is proportional to the partial pressure of the gaseous component to be measured in the test gas, a constant flow rate of test gas being provided through the heater and sensor. Since test gas pressure, temperature, and flow rate are being held constant, changes in sensor voltage are attributable only to changes in the concentration of the measured gas component.

Sprinkle, Danny R.↗

Effects of repeated Valsalva maneuver straining on cardiac and vasoconstrictive baroreflex responses

INTRODUCTION: We hypothesized that repeated respiratory straining maneuvers (repeated SM) designed to elevate arterial BPs (arterial baroreceptor loading) would acutely increase baroreflex responses. METHODS: We tested this hypothesis by measuring cardiac baroreflex responses to carotid baroreceptor stimulation (neck pressures), and changes in heart rate and diastolic BP after reductions in BP induced by a 15-s Valsalva maneuver in 10 female and 10 male subjects at 1, 3, 6, and 24 h after performing repeated SM. Baroreflex responses were also measured in each subject at 1, 3, 6, and 24 h at the same time on a separate day without repeated SM (control) in a randomized, counter-balanced cross-over experimental design. RESULTS: There was no statistical difference in carotid-cardiac and peripheral vascular baroreflex responses measured across time following repeated SM compared with the control condition. Integrated cardiac baroreflex response (deltaHR/ deltaSBP) measured during performance of a Valsalva maneuver was increased by approximately 50% to 1.1 +/- 0.2 bpm x mm Hg(-1) at 1 h and 1.0 +/- 0.1 bpm x mm Hg(-1) at 3 h following repeated SM compared with the control condition (0.7 +/- 0.1 bpm x mm Hg(-1) at both 1 and 3 h, respectively). However, integrated cardiac baroreflex response after repeated SM returned to control levels at 6 and 24 h after training. These responses did not differ between men and women. CONCLUSIONS: Our results are consistent with the notion that arterial baroreceptor loading induced by repeated SM increased aortic, but not carotid, cardiac baroreflex responses for as long as 3 h after repeated SM. We conclude that repeated SM increases cardiac baroreflex responsiveness which may provide patients, astronauts, and high-performance aircraft pilots with protection from development of orthostatic hypotension.

NASA Discipline Cardiopulmonary↗

Evaluation of the electromechanical properties of the cardiovascular system

Cardiovascular electromechanical measurements were collected on returning Skylab crewmembers at rest and during both lower body negative pressure and exercise stress testing. These data were compared with averaged responses from multiple preflight tests. Systolic time intervals and first heart sound amplitude changes were measured. Clinical cardiovascular examinations and clinical phonocardiograms were evaluated. All changes noted returned to normal within 30 days postflight so that the processes appear to be transient and self limited. The cardiovascular system seems to adapt quite readily to zero-g, and more importantly it is capable of readaptation to one-g after long duration space flight. Repeated exposures to zero-g also appear to have no detrimental effects on the cardiovascular system.

Bergman, S. A., Jr.↗